首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The simultaneous determination of amphetamine and methadone was carried out by magnetic graphene oxide nanoparticles, a magnetic solid‐phase extraction adsorbent, as a new sample treatment technique. The main factors (the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, the ionic strength of extraction medium, and agitation rate) influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, good linearity was observed in the range of 100–1500 ng/mL for amphetamine and 100–1000 ng/mL for methadone. The method was evaluated for determination of AM and methadone in positive urine samples, satisfactory results were obtained, therefore magnetic solid‐phase extraction can be applied as a novel method for the determination of drugs of abuse in forensic laboratories.  相似文献   

2.
A new robust method of electromembrane‐surrounded solid‐phase microextraction coupled to ion mobility mass spectrometry was applied for nonsteroidal anti‐inflammatory drugs determination in complex matrices. This is the first time that a graphene/polyaniline composite coating is applied in electromembrane‐surrounded solid‐phase microextraction method. The homemade graphene/polyaniline composite is characterized by a high electrical conductivity and thermal stability. The variables affecting electromembrane‐surrounded solid‐phase microextraction, including extraction time; applied voltage and pH were optimized through chemometric methods, central composite design, and response surface methodology. Under the optimized conditions, limits of detection of 0.04 and 0.05 ng/mL were obtained for mefenamic acid and ibuprofen, respectively. The feasibility of electromembrane‐surrounded solid‐phase microextraction followed by ion mobility mass spectrometry was successfully confirmed by the extraction and determination of low levels of ibuprofen and mefenamic acid in human urine and plasma samples and satisfactory results were obtained.  相似文献   

3.
In order to improve the permeation and adsorption properties of graphene oxide, heteroatoms and deep eutectic solvent were introduced in this study. After being modified, the structural properties of graphene oxide were improved and the materials were applied to the determination of myricetin and rutin in tea sample by pipette‐tip solid‐phase extraction method. The materials were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, X‐Ray diffractomer, energy dispersive spectroscopy, atomic force microscope, and specific surface area by Brunauer–Emmett–Teller N2 adsorption desorption analysis. Meanwhile, they were tested by static and dynamic adsorption. The result showed that the materials after modifying had better adsorption amount for myricetin and rutin than graphene oxide. The calibration graphs of myricetin and rutin in MeOH were linear over 0.10–500.00 µg/mL, and the limits of detection and quantification were in the range of 0.00546–0.0182 µg/mL and 0.00741–0.0247 µg/mL, respectively. A reliable analytical method was developed for recognition targets in tea sample by DES modified nitrogen‐doped graphene oxide with satisfactory extraction recoveries (myricetin 99.77%, rutin 98.14%). It was potential for the rapid purification of myricetin and rutin in tea sample combined with the pipette‐tip solid‐phase extraction.  相似文献   

4.
A three‐dimensional graphene was synthesized through a hydrothermal reaction of graphene oxide with phytic acid. The microstructure and morphology of the phytic acid induced three‐dimensional graphene were investigated by nitrogen adsorption–desorption isotherms, scanning electron microscopy, and transmission electron microscopy. With a large surface area and three‐dimensional structure, the graphene was used as the solid‐phase extraction adsorbent for the extraction of phthalate esters from bottled water and sports beverage samples before high‐performance liquid chromatographic analysis. The results indicated that the graphene was efficient for the solid‐phase extraction of phthalate esters. The limits of detection (S/N = 3) of the method for the analytes were 0.02–0.03 ng/mL for the water samples and 0.03–0.15 ng/mL for the sports beverage sample. The limits of quantitation (S/N = 9) for the analytes were 0.06–0.09 ng/mL for water samples and 0.09–0.45 ng/mL for sports beverage sample. The calibration curves for the phthalate esters by the method had a good linearity from 0.1 to 80.0 ng/mL with correlation coefficients larger than 0.9997. The recoveries of the analytes for the method fell in the range of 86.7–116.2% with the relative standard deviations between 1.5 and 6.8%.  相似文献   

5.
Diallyldimethylammonium chloride modified magnetic nanoparticles were synthesized by the “thiol‐ene” click chemistry reaction. Diallyldimethylammonium chloride rendered the material plenty of quaternary ammonium groups, and thus the excellent aqueous dispersibility and anion‐exchange capability. The novel material was then used as the magnetic solid‐phase extraction sorbent to extract eight non‐steroidal anti‐inflammatory drugs from water samples. Combined with high‐performance liquid chromatography and ultraviolet detection, under the optimal conditions, the developed method exhibited wide linearity ranges (1–1000, 2–1000, and 5–1000 ng/mL) with recoveries of 88.0–108.6% and low limits of detection (0.3–1.5 ng/mL). Acceptable precision was obtained with satisfactory intra‐ and inter‐day relative standard deviations of 0.4–4.4% (= 3) and 1.1–5.5% (= 3), respectively. Batch‐to‐batch reproducibility was acceptable with relative standard deviations <9.7%. The hydrophilic magnetic nanoparticle featured with quaternary ammonium groups showed high analytical potential for acidic analytes in environmental water samples.  相似文献   

6.
Determination of methamphetamine is of great importance in clinical and forensic laboratories because there are low dosages of drugs in the biological media and social problems created due to the methamphetamine consumption. Polymeric carbon based‐nano composites are reasonable candidates for dispersive solid phase extraction method due to facial and affordable synthesis process and high selectivity and sensitivity. Nano graphene oxide polypyrolle composite was synthesized and employed as dispersive solid‐phase extraction adsorbent for methamphetamine extraction from complex urine matrix. Full characterization of the prepared nano graphene oxide polypyrolle composite was completed and the influential extraction parameters were investigated through one‐parameter‐at‐a‐time method. High‐performance liquid chromatography detectors were applied as detection and quantification instrument. The optimized extraction parameters included 300 µL of methanol, 10 min of extraction and desorption time, 6000 stirring rate, urine pH value of 10, 60 mg of adsorbent, and 6 mL of urine volume. After outlining the calibration curve, the linear range of the method was considered as 30–800 ng/mL. The detection limit for the suggested method was 9 ng/mL. The analysis of addicted subjects with the proposed method confirmed the utility of the method in different analytical and clinical laboratories.  相似文献   

7.
A dispersive micro‐solid‐phase extraction procedure coupled with capillary electrophoresis ultraviolet detection was developed for determination of verapamil in plasma samples. Graphene oxide/polydopamin was synthesized by a one‐step polymerization method, and graphene oxide/Fe3O4 (magnetic graphene oxide) nanocomposite was prepared by coprecipitation method. Moreover, they were fully characterized. The use of hazardous and water‐immiscible solvents was scaled down, and only 500 μL of acetone was required as the desorption solvent. The detector response concentration plots were linear in the range of 5–500 ng/mL, and the proposed method was validated according to guidelines. The precision and accuracy were less than 15%. Dispersive micro‐solid‐phase extraction method provides a rapid, environmentally friendly, and sensitive analysis for the verapamil in patient plasma samples, which is adequate for therapeutic drug monitoring and pharmacokinetic studies.  相似文献   

8.
Metal–organic frameworks‐5 (MOF‐5) was explored as a template to prepare porous carbon due to its high surface area, large pore volume, and permanent nanoscale porosity. Magnetic porous carbon, Co@MOF‐5‐C, was fabricated by the one‐step direct carbonization of Co‐doped MOF‐5. After carbonization, the magnetic cobalt nanoparticles are well dispersed in the porous carbon matrix, and Co@MOF‐5‐C displays strong magnetism (with the saturation magnetization intensity of 70.17emu/g), high‐specific surface area, and large pore volume. To evaluate its extraction performance, the Co@MOF‐5‐C was applied as an adsorbent for the magnetic solid‐phase extraction of endocrine disrupting chemicals, followed by their analysis with high‐performance liquid chromatography. The developed method exhibits a good linear response in the range of 0.5–100 ng/mL for pond water and 1.0–100 ng/mL for juice samples. The limits of detection (S/N  = 3) for the analytes were in the range of 0.1–0.2 ng/mL.  相似文献   

9.
A new kind of magnetic N‐doped mesoporous carbon was prepared by the one‐step carbonization of a hybrid precursor (glucose, melamine, and iron chloride) in a N2 atmosphere with a eutectic salt (KCl/ZnCl2) as the porogen. The obtained magnetic N‐doped mesoporous carbon showed excellent characteristics, such as strong magnetic response, high surface area, large pore volume, and abundant π‐electron system, which endow it with a great potential as a magnetic solid‐phase extraction adsorbent. To evaluate its adsorption performance, the magnetic N‐doped mesoporous carbon was used for the extraction of three phthalate esters from soft drink samples followed by high‐performance liquid chromatographic analysis. Under the optimum conditions, the developed method showed a good linearity (1.0–120.0 ng/mL), low limit of detection (0.1–0.3 ng/mL, S/N = 3), and good recoveries (83.2–119.0%) in soft drink samples. The results indicated that the magnetic N‐doped mesoporous carbon has an excellent adsorption capacity for phthalate esters and the present method is simple, accurate, and highly efficient for the extraction and determination of phthalate esters in complex matrix samples.  相似文献   

10.
The presence of pharmaceuticals in the environment due to growing worldwide consumption has become an important problem that requires analytical solutions. This paper describes a CE determination for several nonsteroidal anti‐inflammatory drugs (ibuprofen, naproxen, ketoprofen, diclofenac, ketorolac, aceclofenac and salicylic acid) in environmental waters using hollow fiber membrane liquid‐phase microextraction. The extraction was carried out using a polypropylene membrane supporting dihexyl ether and the electrophoretic separation was performed in acetate buffer (30 mM, pH 4) using ACN as the organic modifier. Detection limits between 0.25 and 0.86 ng/mL were obtained, respectively. The method could be applied to the direct determination of the seven anti‐inflammatories in wastewaters, and five of them have been determined or detected in different urban wastewaters.  相似文献   

11.
A simple pH‐responsive magnetic solid‐phase extraction method was developed using graphene oxide–coated nanoscale zerovalent iron nanoparticles as an efficient adsorbent prior to high‐performance liquid chromatography‐tandem mass spectrometry for determination of ultra‐trace quinolones in milk samples. Various parameters affecting maghemite synthesis and separation such as pH of sample solution, amount of magnetic adsorbent, eluent type, and volume were optimized. The limits of detection are from 3.1 to 13.3 ng/L. The intra‐ and interprecision values are in the range of 2.9–6.9% and 7.6–15.1%, respectively. Recoveries are from 82.4 to 103.9%. Therefore, this simple and sensitive method is suitable for detecting ultra‐trace quinolone residues in milk.  相似文献   

12.
Here in, magnetic nanoparticles combined with graphene oxide adsorbent were fabricated via a microwave‐assisted synthesis method, and used in the solid‐phase extraction of three phenolic compounds (phenol, 4‐nitrophenol, and m‐methylphenol) in environmental water samples. Various instrumental methods were employed to characterize the magnetic nanoparticles modified with graphene oxide. The influence of experimental parameters, such as desorption conditions, amount of adsorbent, extraction time, and pH, on the extraction efficiency was investigated. Owing to the high surface area and excellent adsorption capacity of the prepared material, satisfactory extraction was achieved. Under optimum conditions, a linear response was observed in the concentration range of 1.000–100.0 μg/L for phenol, 0.996–99.6 μg/L for 4‐nitrophenol, and 0.975–97.5 μg/L for m‐methylphenol, with correlation coefficients in the range of 0.9995–0.9997. The limit of detection (signal‐to‐noise ratio of 3) of the method varied between 0.5 and 0.8 μg/L. The relative standard deviations were <5.2%. The recovery percentages of the method were in the range of 89.1–104.3%. The results indicate that the graphene oxide‐modified magnetic nanoparticles possess high adsorptive abilities toward phenolic compounds in environmental water samples.  相似文献   

13.
A simple hydrophilic polyamide organic membrane protected micro‐solid‐phase extraction method with graphene oxide as the sorbent was developed for the enrichment of some parabens from water and vinegar samples prior to gas chromatography with mass spectrometry detection. The main experimental parameters affecting the extraction efficiencies, such as the type and amount of the sorbent, extraction time, stirring rate, salt addition, sample solution pH and desorption conditions, were investigated. Under the optimized experimental conditions, the method showed a good linearity in the range of 0.1–100.0 ng/mL for water samples and 0.5–100.0 ng/mL for vinegar samples, with the correlation coefficients varying from 0.9978 to 0.9997. The limits of detection (S/N = 3) of the method were in the range of 0.005–0.010 ng/mL for water samples and 0.01–0.05 ng/mL for vinegar samples, respectively. The recoveries of the method for the analytes at spiking levels of 5.0 and 70.0 ng/mL were between 84.6 and 106.4% with the relative standard deviations varying from 4.2 to 9.5%. The results indicated that the developed method could be a practical approach for the determination of paraben residues in water and vinegar samples.  相似文献   

14.
A simple, rapid, and highly sensitive method for simultaneous analysis of anti‐inflammatory drugs (naproxen, ibuprofen, and mefenamic acid) in diluted human serum was developed using the electrochemically controlled solid‐phase microextraction coupled to ion mobility spectrometry. A conducting molecularly imprinted polymer film based on polypyrrole was synthesized for the selective uptake and release of drugs. The film was prepared by incorporation of a template molecule (naproxen) during the electropolymerization of pyrrole onto a platinum electrode using cyclic voltammetry method. The measured ion mobility spectrometry intensity was related to the concentration of analytes taken up into the films. The calibration graphs (naproxen, ibuprofen, and mefenamic acid) were linear in the range of 0.1–30 ng/mL and detection limits were 0.07–0.37 ng/mL and relative standard deviation was lower than 6%. On the basis of the results obtained in this work, the conducting molecularly imprinted polymer films as absorbent have been applied in the electrochemically controlled solid‐phase microextraction and ion mobility spectrometry system for the selective clean‐up and quantification of trace amounts of anti‐inflammatory drugs in human serum samples. Scanning electron microscopy has confirmed the nano‐structure morphology of the polypyrrole film.  相似文献   

15.
Magnetic zeolitic imidazolate framework 67/graphene oxide composites were synthesized by one‐pot method at room temperature for the first time. Electrostatic interactions between positively charged metal ions and both negatively charged graphene oxide and Fe3O4 nanoparticles were expected to chemically stabilize magnetic composites to generate homogeneous magnetic products. The additional amount of graphene oxide and stirring time of graphene oxide, Co2+, and Fe3O4 solution were investigated. The zeolitic imidazolate framework 67 and Fe3O4 nanoparticles were uniformly attached on the surface of graphene oxide. The composites were applied to magnetic solid‐phase extraction of five neonicotinoid insecticides in environmental water samples. The main experimental parameters such as amount of added magnetic composites, extraction pH, ionic strength, and desorption solvent were optimized to increase the capacity of adsorbing neonicotinoid insecticides. The results show limits of detection at signal‐to‐noise ratio of 3 were 0.06–1.0 ng/mL under optimal conditions. All analytes exhibited good linearity with correlation coefficients of higher than 0.9915. The relative standard deviations for five neonicotinoid insecticides in environmental samples ranged from 1.8 to 16.5%, and good recoveries from 83.5 to 117.0% were obtained, indicating that magnetic zeolitic imidazolate framework 67/graphene oxide composites were feasible for analysis of trace analytes in environmental water samples.  相似文献   

16.
A dispersive liquid–liquid extraction based on Pickering emulsion stabilized with ferroferric oxide grafted nitrogen‐doped graphitized carbon black has been developed to simultaneously determine seven aldehydes in environmental water samples, in combination with pentafluorobenzyl hydroxylamine precolumn derivatization gas chromatography–tandem mass spectrometry. The nitrogen‐doped graphitized carbon was prepared from dicyandiamide waste residue with a simple acid wash process. The effects of magnetic emulsifier amount, extraction time, solution pH, and oil/water volume ratio on the formation of magnetically responsive Pickering emulsion and the extraction efficiency of the proposed dispersive liquid–liquid extraction were also investigated. Under the optimized conditions, satisfactory linearities were obtained for all aldehydes with correlation coefficients larger than 0.9984. The limits of detection and quantitation of seven aldehydes were in the range of 17.3–30.1 ng/L and 54.3–103.4 ng/L, respectively, with intra‐ and interday relative standard deviations less than 8.6%. The mean recoveries at three spiked levels ranged from 70.0 to 101.4%. With the Pickering emulsion as a “minimized extractor”, the extraction was accomplished within 5 min. After extraction, the magnetic disperser could be recovered for reuse at least five times by an external magnetic field. The proposed method was demonstrated to be feasible, simple, and economic for the trace analysis of the aldehydes in environmental water samples.  相似文献   

17.
A novel magnetic adsorbent Fe3O4/reduced graphene oxide‐carbon nanotubes, was prepared by one‐pot solvothermal synthesis method. It was characterized by scanning electron microscopy, X‐ray powder diffraction and vibrating sample magnetometry. The diameter of Fe3O4 microparticles was about 350 nm, which were covered by carbon nanotubes and reduced graphene oxide sheets, while carbon nanotubes inserted between the reduced graphene oxide sheets effectively prevented their aggregation. The composite had large surface area and good magnetic property, suiting for magnetic solid‐phase extraction and the determination of sulfonamides, by coupling with high‐performance liquid chromatography. Under the optimized conditions (including extraction time, amount of adsorbent, solution pH, ionic strength and desorption conditions), a good linear was achieved in the concentration range of 5–500 μg/L and the low limits of detection and low limits of quantification were 0.35–1.32 and 1.16–4.40 μg/L, respectively. The enrichment factors were estimated to be 24.72 to 30.15 fold. The proposed method was applied for the detection of sulfonamides in milk sample and the recoveries were 88.4–105.9%, with relative standard deviations of 0.74–5.38%.  相似文献   

18.
We describe the preparation, characterization, and application of a composite film adsorbent based on blended agarose‐chitosan‐multiwalled carbon nanotubes for the preconcentration of selected nonsteroidal anti‐inflammatory drugs in aqueous samples before determination by high performance liquid chromatography with ultraviolet detection. The composite film showed a high surface area (4.0258 m2/g) and strong hydrogen bonding between the multiwalled carbon nanotubes and agarose/chitosan matrix, which prevent adsorbent deactivation and ensure long‐term stability. Several parameters, such as sample pH, addition of salt, extraction time, desorption solvent, and concentration of multiwalled carbon nanotubes in the composite film were optimized using a one‐factor‐at‐time approach. The optimum extraction conditions obtained were as follows: isopropanol as conditioning solvent, 10 mL of sample solution at pH 2, extraction time of 30 min, stirring speed of 600 rpm, 100 μL of isopropanol as desorption solvent, desorption time of 5 min under ultrasonication, and 0.4% w/v of composite film. Under the optimized conditions, the calibration curve showed good linearity in the range of 1–500 ng/mL (r2 = 0.997–0.999), and good limits of detection (0.89–8.05 ng/mL) were obtained with good relative standard deviations of < 4.59% (n = 3) for the determination of naproxen, diclofenac sodium salt, and mefenamic acid drugs.  相似文献   

19.
A novel 3D‐graphene (3D‐G) magnetic nanomaterial was prepared and used as an adsorbent for the extraction of four neonicotinoid insecticides (acetamiprid, imidacloprid, thiacloprid, and thiamethoxam) from lemon juice sample. Then, HPLC with UV detection was applied for the determination of the neonicotinoid insecticides desorbed from the 3D‐G magnetic nanomaterial. The main experimental parameters that affect the extraction efficiencies such as the amount of 3D‐G magnetic nanomaterial, sample solution pH, extraction time, salting‐out effect, and desorption conditions were studied and optimized. As a result, the linear concentration range of the method was from 0.3 to 100.0 ng/mL for thiacloprid, from 0.5 to 100.0 ng/mL for imidacloprid and acetamiprid, and from 1.0 to 100.0 ng/mL for thiamethoxam, with correlation coefficients of 0.9965–0.9985, respectively. The LODs of the method based on an S/N of 3 were between 0.08 and 0.2 ng/mL. The enrichment factors obtained were between 67 and 427, and the RSDs (n = 6) were in the range from 4.6 to 7.1%, and the recoveries of the method fell in the range of 88.75 to 111.60%.  相似文献   

20.
An iron‐embedded porous carbon material (MIL‐53‐C) was fabricated by the direct carbonization of MIL‐53. The MIL‐53‐C possesses a high surface area and good magnetic behavior. The structure, morphology, magnetic property, and porosity of the MIL‐53‐C were studied by scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and N2 adsorption. With the use of MIL‐53‐C as the magnetic solid‐phase extraction adsorbent, a simple and efficient method was developed for the magnetic solid‐phase extraction of three hormones from water and human urine samples before high‐performance liquid chromatography with UV detection. The developed method exhibits a good linear response in the range of 0.02–100 ng/mL for water and 0.5–100 ng/mL for human urine samples , respectively. The limit of detection (S/N = 3) for the analytes was 0.005–0.01 ng/mL for water sample and 0.1–0.3 ng/mL for human urine sample. The limit of quantification (S/N = 10) of the analytes were in the range of 0.015–0.030 and 0.3–0.9 ng/mL, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号