首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An ultrasound-assisted solvent extraction procedure has been optimised to speed up total polycyclic aromatic hydrocarbons (T-PAHs) extraction from mussel soft tissue. The T-PAHs releases have been evaluated by spectrofluorimetry (excitation and fluorescence emission wavelengths of 300 and 382 nm, respectively, and using chrysene as calibrant). Variables such as sonication time, ultrasound frequency, n-hexane volume, dichloromethane volume, number of repeated extractions with n-hexane and number of repeated extraction with dichloromethane were simultaneously studied by applying a Plackett-Burman design (PBD) approach. Results showed that ultrasound frequency and n-hexane and dichloromethane volumes were statistically significant variables (confidence interval of 95%). These last two variables were finally optimised by using central composite designs (CCD), yielding optimum n-hexane and dichloromethane volumes of 2.5 and 6.5 ml, respectively. The lowest T-PAHs releasing at high ultrasound frequency (35 kHz) led to choice the lowest ultrasound frequency (17 kHz) to perform the extraction. Variables such as sonication time and number of repeated extraction with n-hexane or dichloromethane were statistically non-significant and they were fixed at 10 min and the extraction with n-hexane and dichloromethane were performed once. The limit of detection was 0.021 μg g−1 (referred to dried mass), the repeatability of the overall method was 4.7% (n = 9) and the analytical recoveries were between 98 and 105%. The proposed method was finally applied to 16 mussel samples (Mytilus galloprovincialis) from Ría de Arousa estuary (Galicia, northwest Spain).  相似文献   

2.
谈义萌  唐涛  杨三东  夏明珠  王风云  李彤 《色谱》2017,35(9):1003-1007
超分子溶剂是两亲化合物通过分子间有序的自组装过程形成的具有纳米结构的胶束聚集体,是一种高效提取溶剂。该文以高效液相色谱-荧光检测法为测试手段,系统地对超分子溶剂组成及用量进行了优化,发展了一种直接提取、快速测定水中多环芳烃的方法,并进行了方法学验证及实际样品检测。结果表明,采用四氢呋喃和1-辛醇制备的超分子溶剂对4种多环芳烃的回收率为89.08%~102.47%,相对标准偏差(RSD,n=5)为1.38%~3.92%。4种多环芳烃在一定范围内线性关系良好(相关系数R~20.999),检出限为1.26~9.23 ng/L。该方法前处理过程简单,有利于实现快速分析;溶剂使用量少,符合绿色化学的发展趋势,具有一定的推广价值。  相似文献   

3.
王美飞  杨丽莉  胡恩宇 《色谱》2017,35(6):669-673
建立了一种微波提取-高效液相色谱法测定大气颗粒物中多环芳烃的方法。吸附有颗粒物的超细玻璃纤维/石英纤维滤膜用正己烷/丙酮(1∶1,v/v)混合溶剂经微波提取,提取液用弗罗里硅土柱净化,经浓缩定容后,采用液相色谱法-二极管阵列(PDA)-荧光双检测器测定。目标化合物在20.0~500μg/L范围内线性良好,相关系数不小于0.996 0。空白膜加标结果显示,目标化合物的回收率在56.3%~101%之间。该法已运用于南京市大气颗粒物中多环芳烃分布的调查研究。  相似文献   

4.
In the present study, a simple and rapid method for the extraction and preconcentration of some polycyclic aromatic hydrocarbons in water samples has been developed. In this method, two sample preparation methods were combined to obtain high extraction recoveries and enrichment factors for sensitive analysis of the selected analytes. In the first stage of the method, a homogeneous solution containing an aqueous solution and cyclohexyl amine is broken by the addition of a salt. After centrifugation, the upper collected phase containing the extracted analytes is subjected to the following dispersive liquid–liquid microextraction method. Rapid injection of the mixture of cyclohexyl amine resulted from the first stage and 1,1,2‐trichloroethane (as an extraction solvent) into an acetic acid solution is led to form a cloudy solution. After centrifuging, the fine droplets of the extraction solvent are settled down in the bottom of the test tube, and an aliquot of it is analyzed by gas chromatography. Under the optimum extraction conditions, enrichment factors and limits of detection for the studied analytes were obtained in the ranges of 616–752 and 0.08–0.20 μg/L, respectively. The simplicity, high extraction efficiency, short sample preparation time, low cost, and safety demonstrated the efficiency of this method relative to other approaches.  相似文献   

5.
超高效液相色谱法检测土壤中的多环芳烃   总被引:6,自引:1,他引:6  
陈皓  刘颖  刘海玲  袁园  肖乾芬 《色谱》2008,26(6):769-711
采用二极管阵列(PDA)检测器,建立了超高效液相色谱(UPLC)定性定量分析土壤中16种多环芳烃(PAHs)的方法。并将该方法与传统高效液相色谱(HPLC)的分析性能进行了详细的比较。研究结果表明,采用UPLC法分析16种PAHs具有分析速度快(13.5 min)、检出限低(2~20 pg)、灵敏度高等优点。  相似文献   

6.
7.
Headspace solvent microextraction (HSME) was shown to be an efficient preconcentration method for extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample solutions. A microdrop of 1-butanol (as extracting solvent) containing biphenyl (as internal standard) was used in this investigation. Extraction occurred by suspending a 3 μl drop of 1-butanol from the tip of a microsyringe fixed above the surface of solution in a sealed vial. After extraction for a preset time, the microdrop was retracted back into the syringe and injected directly into a GC injection port. The effects of nature of extracting solvent, microdrop and sample temperatures, stirring rate, microdrop and sample volumes, ionic strength and extraction time on HSME efficiency were investigated and optimized. Finally, the enrichment factor, dynamic linear range (DLR), limit of detection (LOD) and precision of the method were evaluated by water samples spiked with PAHs. The optimized procedure was successfully applied to the extraction and determination of PAHs in different water samples.  相似文献   

8.
Lubov Oliferova  Yury Zolotov 《Talanta》2007,72(4):1386-1391
Naphthalene, biphenyl, acenaphtene, anthracene and pyrene were extracted from water samples using inner walls of polytetrafluoroethylene capillary. Optimum conditions for sorption, desorption and heart-cutting of the analyte zone were found. Combined on-line solid-phase extraction and HPLC method for determination of these compounds was proposed. Limits of detection were: (μg L−1): 0.4 (naphthalene), 0.3 (biphenyl), 0.6 (acenaphtene), 0.2 (anthracene) and 0.1 (pyrene).  相似文献   

9.
A mesoporous silica was functionalized by carbon nanotubes to enhance the extraction performance. The mesoporous material was coated on stainless steel wires, and three wires were inserted inside of a polyetheretherketone tube for in‐tube solid‐phase microextraction. The tube was coupled to high‐performance liquid chromatography with diode array detection to obtain online analytical system, then its extraction performance was evaluated using eight polycyclic aromatic hydrocarbons as the targets. In order to good sensitivity and accuracy, four conditions were optimized such as sampling volume, sampling rate, methanol content in the sample, and desorption time. Under the optimum conditions, an online analytical method was established and exhibited low limits of detection from 0.005 to 0.050 µg/L, wide linear range of 0.016‐20.00 µg/L with acceptable correlation coefficients in 0.9921‐0.9999, as well as large enrichment factors in the range of 311‐2412. The method was successfully applied to determine trace polycyclic aromatic hydrocarbons in some real water samples including, two kinds of bottled water, tap water, and river water, a few polycyclic aromatic hydrocarbons were detected but none quantified in these samples.  相似文献   

10.
An efficient clean-up procedure coupled with a high performance liquid chromatography (HPLC) with on-line electrochemical (EC) reduction and fluorescence detection (FLD) was developed to quantify nitrated polycyclic aromatic hydrocarbons (NPAHs) in the airborne particulate. In this process, NPAHs were extracted ultrasonically followed by analysis by using a reversed phase column with an aqueous eluent containing 70% aqueous acetonitrile and sodium monocholoroacetate as a buffer solution. The extraction efficiencies were above 83% for 1-nitropyrene and 1,3-dinitropyrene (1,3-DNP) 1,6-DNP, and 1,8-DNP, and calibration graphs were linear with very good correlation coefficients (r>0.999) and the detection limits were in the range of 1.0-2.2 pg for dinitropyrenes and nitropyrene. The proposed method provides a relatively simple and convenient procedure for determining the NPAHs samples in airborne particulate.  相似文献   

11.
In this work, iron (III) oxinate magnetic nanocomposite was synthesized and employed as an efficient sorbent for the magnetic dispersive solid-phase extraction of some polycyclic aromatic hydrocarbons from honey samples. In the following, dispersive liquid–liquid microextraction procedure was used for further preconcentration of the analytes. The prepared sorbent was characterized using Fourier transform infrared spectrophotometry, X-ray diffractometry, vibrating sample magnetometry, energy dispersive X-ray spectroscopy, and scanning electron microscopy. The results verified the successful formation of the magnetic sorbent. In the extraction process, the sorbent was added into an aqueous solution and the mixture was vortexed. After completing the adsorption process, the supernatant phase was separated in the presence of a magnet and the analytes adsorbed onto sorbent were eluted by acetonitrile. Then, microliter-level 1,1,1–trichloroethane was mixed with the obtained acetonitrile and injected into NaCl solution. Finally, one microliter of the sedimented phase was injected into gas chromatography-flame ionization detector after centrifugation. Under the optimum conditions, a great repeatability (relative standard deviation equal or less than 5 and 6% for intra– and interday precisions, respectively), acceptable extraction recoveries (59–84%), high enrichment factors (118–168), and low limits of detection and quantification (0.16–0.36 and 0.56–1.22 ng/g, respectively) were acquired.  相似文献   

12.
A bonding method was developed for coating molybdenum oxides onto a steel wire substrate, which was used as a solid‐phase microextraction fiber, was coupled with gas chromatography. Based on the characterization, it is found that the as‐prepared molybdenum oxides material contained a nanobelt structure with a uniform size and good dispersibility. In addition, there were a large number of small protrusions on the surface of the nanobelts. These characteristics provided a large specific surface area for extraction. Molybdenum oxides exhibited a high extraction selectivity for polycyclic aromatic hydrocarbons owing to its moderate coordination. After the optimization of the factors, method detection limits of < 1.25 μg/L were achieved, and the calibration curves were linear within the range of 2–600 μg/L. In addition, repeatability was demonstrated, and the relative standard deviation < 6.4%. The molybdenum oxides coating had a high scratch resistance, which could effectively prevent coating wear and failure. Combined with the high thermal and chemical stability, the service life of the coating was improved and could be used 150 times without a significant reduction in the extraction performance. Finally, the as‐prepared fiber had a comparable extraction capacity and higher partition coefficients that those of commercial polyacrylate fibers.  相似文献   

13.
A solid‐phase microextraction with carbon nanospheres coated fiber coupled with gas chromatographic detection was established for the determination of eight polycyclic aromatic hydrocarbons (naphthalene, biphenyl, acenaphthene, fluorine, phenanthrene, anthracene, fluoranthene, and pyrene) in water and soil samples. The experimental parameters (extraction temperature, extraction time, stirring rate, headspace volume, salt content, and desorption temperature) which affect the extraction efficiency were studied. Under the optimized conditions, good linearity between the peak areas and the concentrations of the analytes was achieved in the concentration range of 0.5‐300 ng/mL for water samples, and in the concentration range of 6.0‐2700 ng/g for soil samples. The detection limits for the analytes were in the range of 0.12‐0.45 ng/mL for water samples, and in the range of 1.53‐2.70 ng/g for soil samples. The method recoveries of the polycyclic aromatic hydrocarbons for spiked water samples were 80.10‐120.1% with relative standard deviations less than 13.9%. The method recoveries of the analytes for spiked soil samples were 80.40‐119.6% with relative standard deviations less than 14.4%. The fiber was reused over 100 times without a significant loss of extraction efficiency.  相似文献   

14.
A method has been developed for the trace analysis of polycyclic aromatic hydrocarbons, which are known as persistent organic pollutants and ubiquitous constituents of fine particulate matter that causes growing airborne pollution. The method, which was especially for samples of airborne particulate matter less than 2.5 μm in diameter, utilized accelerated solvent extraction and ultra high performance liquid chromatography with fluorescence detector. Four principal parameters of accelerated solvent extraction were optimized to obtain maximum extraction efficiency. Using the established synergetic programs of gradient elution and fluorescence wavelength switching, a rapid separation was achieved in 6.56 min with good linearity for 15 polycyclic aromatic hydrocarbons (coefficient of determination above 0.999). The limits of detection ranged from 0.833 to 10.0 pg/m3. The precision of the method expressed as inter‐day relative standard deviation ranged from 0.2 to 1%, which was calculated from nine repetitive measurements of 8.00 μg/L analytes. Average spiked recoveries ranged from 71.6 to 97.7%, with the exception of naphthalene. The rapid, sensitive, and accurate method can meet the pressing needs of health risk assessment and increasingly heavy daily tasks of air quality monitoring.  相似文献   

15.
刘志超  胡霞林  刘景富 《色谱》2010,28(5):513-516
以涂有聚二甲基硅氧烷(PDMS)的石英光导纤维作为固相微萃取纤维,建立了一次性固相微萃取与高效液相色谱联用测定环境水样中的菲、荧蒽和屈3种多环芳烃(PAHs)的方法。实验考察了解吸时间、萃取时间、搅拌速度、盐效应以及样品溶液pH值对萃取效率的影响,优化得到的萃取和解吸条件为: 于60 mL样品溶液中放入两段萃取纤维(1.5 cm)和1.2 g氯化钠,在1200 r/min搅拌速度下萃取60 min,取出萃取纤维并转入120 μL甲醇中密封静置解吸24 h后,取20 μL解吸液进行液相色谱测定。该方法对于菲、荧蒽和屈的检出限分别为0.17、0.17和0.08 μg/L;精密度(以测定0.5 μg/L PAHs标准溶液6次的相对标准偏差计)小于8%;实际样品中3种PAHs的加标回收率为80.0%~107%。该方法快速简便,纤维一次性使用,克服了污染物在纤维上残留的问题。  相似文献   

16.
Silk fibers were carbonized to develop a biomass carbon material as an adsorbent for solid‐phase microextraction. The surface structure of the carbonized silk fibers was characterized by scanning electron microscopy, and the graphitization degree was determined by Raman spectrometry. After carbonization under high temperature, the orderliness and structural regularity of carbon atoms on silk fibers were promoted. Extraction tube packed with carbonized silk fibers was prepared for in‐tube solid‐phase microextraction. Coupled with high performance liquid chromatography, it exhibited good extraction performance for hydrophobic polycyclic aromatic hydrocarbons. Main parameters including sampling volume, sampling rate, methanol content in sample, and desorption time were systematically investigated. Under the optimum conditions, the analysis method was established and it exhibited wide linear range (0.016–20 μg/L) with good linearity (correlation coefficient ≥ 0.9947), low limits of detection (0.005–0.050 μg/L), and high enrichment factors (1189–2775). Relative standard deviations (n = 3) for intraday (≤3.3%) and interday (≤9.6%) tests indicated that the extraction material had satisfactory repeatability. Finally, the analytical method was successfully applied to detect trace polycyclic aromatic hydrocarbons in real water samples, demonstrating its satisfactory practicability.  相似文献   

17.
Supercritical fluid extraction (SFE) was performed to extract complex mixtures of polycyclic aromatic hydrocarbons (PAHs), nitrated derivatives (nitroPAHs) and heavy n-alkanes from spiked soot particulates that resulted from the incomplete combustion of diesel oils. This polluted material, resulting from combustion in a light diesel engine and collected at high temperature inside the particulate filter placed just after the engine, was particularly resistant to conventional extraction techniques, such as soxhlet extraction, and had an extraction behaviour that differed markedly from certified reference materials (SRM 1650). A factorial experimental design was performed, simultaneously modelling the influence of four SFE experimental factors on the recovery yields, i.e.: the temperature and the pressure of the supercritical fluid, the nature and the percentage of the organic modifier added to CO2 (chloroform, tetrahydrofuran, methylene chloride), as a means to reach the optimal extraction yields for all the studied target pollutants. The results of modelling showed that the supercritical fluid pressure had to be kept at its maximum level (30 MPa) and the temperature had to be kept relatively low (75 °C). Under these operating conditions, adding 15% of methylene chloride to the CO2 permitted quantitative extraction of not only light PAHs and their nitrated derivatives, but also heavy n-alkanes from the spiked soots. However, heavy polyaromatics were not quantitatively extracted from the refractory carbonaceous solid surface. As such, original organic modifiers were tested, including pyridine, which, as a strong electron donor cosolvent (15% into CO2), was the most successful. The addition of diethylamine to pyridine, which enhanced the electron donor character of the cosolvent, even increased the extraction yields of the heaviest PAHs, leading to a quantitative extraction of all PAHs (more than 79%) from the diesel particulate matter, with detection limits ranging from 0.5 to 7.8 ng for 100 mg of spiked material. Concerning the nitrated PAHs, a small addition of acetic acid into pyridine, as cosolvents, gave the best results, leading to fair extraction yields (approximately 60%), with detection limits ranging from 18 to 420 ng.  相似文献   

18.
陈娜  张毅军  赵万里  陈军  张裕平 《色谱》2018,36(1):5-11
采用氯化胆碱-乙二醇低共熔溶剂(DES)作致孔剂,制备了聚(甲基丙烯酸丁酯-乙二醇二甲基丙烯酸酯)[poly(BMA-EDMA)]固相微萃取头,并与超高效液相色谱法(UPLC)结合测定了湖水中的3种多环芳烃(PAHs)。实验与不使用DES致孔剂的固相微萃取头和商品化聚二甲硅氧烷(PDMS)萃取头进行比较,含DES的poly(BMA-EDMA)固相微萃取头的富集效果最好。系统考察了萃取条件(萃取时间、萃取溶剂、解吸时间、解吸溶剂及离子强度)对水样中多环芳烃萃取效率的影响。在最优的实验条件下,3种多环芳烃类化合物(萘、联苯、菲)的线性范围为0.1~6.0 mg/L(r≥0.990 3),检出限为2.1~4.9μg/L,回收率为86.4%~111.3%,相对标准偏差(RSD,n=6)为11.2%~15.1%。该法操作简便,稳定性好,成本低,适用于实际环境水样中多环芳烃类化合物的测定。  相似文献   

19.
建立了基于聚合物整体柱的固相萃取-高效液相色谱测定尿液中4种羟基多环芳烃(OH-PAHs)的分析方法。在注射器管中合成聚(甲基丙烯酸丁酯-乙二醇二甲基丙烯酸酯)整体柱(poly (BMA-co-EDMA)),并将其用于尿液中4种羟基多环芳烃的前处理,同时考察了上样浓度、淋洗液、洗脱液和洗脱体积对萃取效率的影响。结合高效液相色谱-荧光分析,4种羟基多环芳烃在各自的范围内线性关系良好(r≥0.9991);方法的检出限和定量限分别为0.06~0.09 ng/mL和0.20~0.30 ng/mL;日内(n=5)和日间(n=3)精密度分别为1.4%~5.3%和2.6%~7.3%。对焦炉工人尿液样品进行加标(3 ng/mL)回收试验,回收率为78.2%~117.0%。该固相萃取柱能够有效萃取和净化尿液中4种羟基多环芳烃,并且可以重复使用。该法简单、准确,可应用于尿液中羟基多环芳烃的分析。  相似文献   

20.
In this article, homogeneous liquid–liquid extraction (HOLLE), combined with HPLC-fluorescence detector (HPLC-FLD), has been developed for the extraction and determination of polycyclic aromatic hydrocarbons (PAHs) in vegetables. ACN was used as extraction solvent for the extraction of target analytes from vegetables. When the previous extraction process was over, the ACN extract was transferred to the water-immiscible organic phase, tetrachloroethane, used as extraction solvent in HOLLE procedures. Under the optimum conditions, repeatability was carried out by spiking PAHs at concentration level of 12.5 μg/kg, the RSDs varied between 1.1 and 8.5% (n = 3). The LODs, based on S/N of 3, ranged from 0.025 to 0.25 μg/kg. Relative recoveries of PAHs from cucumber and long crooked squash samples were in the range of 72.4–104.9% and 65.5–119.3%, respectively. Compared with the conventional extraction method, the proposed method has the advantage of being quick, easy to operate, and having low consumption of organic solvent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号