首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 886 毫秒
1.
A regenerable, labelless electrochemical immunosensor is investigated. In this work, pyrrole (Py) and pyrrole propylic acid (Pa) were co‐electropolymerized in the presence of gold nanoparticles to form a porous, conductive, stable and hydrophilic nanocomposite, followed by the covalent attachment of protein G to capture an antibody as the probe for the immunoassay. The regeneration of the sensor was achieved by rinsing the electrodes with 0.1 M glycine buffer (pH 2.7). The binding and dissociation of the antibody with protein G and optimization of the efficient immobilization were studied by impedance and optical measurements, respectively. The charge transfer resistance obtained from the impedance measurements is used to study the interaction between antibody‐protein G and antibody‐antigen. The immunosensor performance and its regenerability were evaluated by using anti‐leptin IgG as the probe protein to detect leptin in 0.01 M PBS, and its specificity was tested in 1% human serum. The leptin impedimetric immunosensor exhibits a detection dynamic range of 10–100 000 ng/mL with 10 ng/mL detection limit in 0.01 M PBS+1% serum solutions. This work proves the feasibility to make a sensitive, regenerative electrochemical immunosensor, which could be very useful for environmental control and food analysis.  相似文献   

2.
A new electrochemical immunosensor for the detection of α‐1‐fetoprotien (AFP) was developed based on AFP antibody (anti‐AFP)‐functionalized organic/inorganic hybrid nanocomposite membrane. To fabricate such a hybrid composite membrane, 3,4,9,10‐perylenetetracarboxylic acid‐bound thionine molecules (PTCTH) were initially doped into titania colloids (TiO2), and then gold nanoparticles and anti‐AFP were immobilized onto the composite film in turn. Comparison with the electrode fabricated only with thionine not 3,4,9,10‐perylenetetracarboxylic acid, the immunosensor with PTCTH exhibited high sensitivity and fast electron transfer. The presence of gold nanoparticles provided a good microenvironment for the immobilization of biomolecules, enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The modified process was characterized by scanning electron microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The surface topography of the membrane was investigated by scanning electron microscopy (SEM). Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 2.5 to 200.0 ng/mL towards AFP with a detection limit of 0.5 ng/mL (S/N=3). The stability, reproducibility and precision of the immunosensor were acceptable. Comparison with the conventional enzyme‐linked immunosorbent assay (ELISA), the present method did not require more labeled procedures and washing steps. Significantly, the detection methodology provides a promising approach for other proteins or biosecurities.  相似文献   

3.
A molecularly imprinted electrochemical sensor is successfully developed to detect bovine serum albumin (BSA) based on the dynamic electrochemical impedance spectroscopy (DEIS) instead of the traditional impedance spectroscopy. The sensor is prepared using chitosan and pyrrole as modified material and functional monomers, respectively, and the fast and real‐time characterization of molecular imprinting process can be obtained by DEIS. It is indicated that the removal and rebinding processes of BSA are closely related with the DEIS impedance under dynamic conditions, and the direct correlation between the resulting kinetic information and BSA concentrations can be established. As a result, the impedance changing rates in the initial 5 min of BSA adsorption are linear to the BSA concentrations ranging from 0.0001 to 0.01 ng mL?1 and 0.01 to 1 ng mL?1 with a detection limit of 5×10?5 ng mL?1 (S/N=3). In addition, the detection of BSA by DEIS does not require the system to be in equilibrium. The sensor also shows simplicity, high sensitivity, good stability and acceptable recovery in real samples, indicating its promising prospects in the fast and real‐time detection of proteins.  相似文献   

4.
Various sensor‐based immunoassay methods have been extensively developed for the detection of cancer antigen 15‐3 (CA 15‐3), but most often exhibit low detection signals and low detection sensitivity, and are unsuitable for routine use. The aim of this work is to develop a simple and sensitive electrochemical immunoassay for CA 15‐3 in human serum by using nanogold and DNA‐modified immunosensors. Prussian blue (PB), as a good mediator, was initially electrodeposited on a gold electrode surface, then double‐layer nanogold particles and double‐strand DNA (dsDNA) with the sandwich‐type architecture were constructed on the PB‐modified surface in turn, and then anti‐CA 15‐3 antibodies were adsorbed onto the surface of nanogold particles. The double‐layer nanogold particles provided a good microenvironment for the immobilization of biomolecules. The presence of dsDNA enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The performance and factors influencing the performance of the immunosensor were evaluated. Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 1.0 to 240 ng/mL with a relatively low detection limit of 0.6 ng/mL (S/N=3) towards CA 15‐3. The stability, reproducibility and precision of the as‐prepared immunosensor were acceptable. 57 serum specimens were assayed by the developed immunosensor and standard enzyme‐linked immunosorbent assay (ELISA), respectively, and the results obtained were almost consistent. More importantly, the proposed methodology could be further developed for the immobilization of other proteins and biocompounds.  相似文献   

5.
In this study, a molecularly imprinted sensor technology is engineered to detect glucose in real blood samples by chronoimpedimetrically. The imprinting process of glucose (Glc) was carried out by electrochemical polymerization of aminophenylboronic acid (APBA) and pyrrole (Py) by performing cyclic voltammetry (CV). Afterwards, glucose molecule was removed from imprinted surface by 5 % acetic acid to reveal glucose imprinted cavities. Electrochemical Impedance Spectroscopy (EIS) was used to characterize sensor modification steps and glucose removal. Glucose monitoring process was carried out chronoimpedimetrically(CI) for the first time in real blood samples. Calibration curve was prepared between 20–800 mg/dL. The standard deviations of the 18 calibration curves R2 were calculated as 0.9866±0.0066 to assess reproducibility. Recovery was calculated by using 105 mg/dL Glc Serum Sample, which was monitored by auto analyzer and into this sample 50 mg/dL Glc added and our sensor response was 147.92±2.43 mg/dL, 98.6±1.62 % (n=5). Non‐imprinted (NIP) sensor gave no signal for the glucose concentration.  相似文献   

6.
《Electroanalysis》2006,18(22):2194-2201
A new amperometric immunobiosensor for carcinoembryonic antigen (CEA) determination in human serum was developed via encapsulation of horseradish peroxidase‐labeled carcinoembryonic antibody (HRP‐anti‐CEA) in a gold nanoparticles/DNA composite architecture. The presences of gold nanoparticles provided a congenial microenvironment for the immobilized biomolecules and decreased the electron transfer impedance, leading to a direct electrochemical behavior of the immobilized HRP. The formation of the antibody–antigen complex by a simple one‐step immunoreaction between the immobilized HRP‐anti‐CEA and CEA in sample solution introduced a barrier of direct electrical communication between the immobilized HRP and the gold electrode surface. Under optimal conditions, the current change obtained from the labeled HRP relative to H2O2 system was proportional to the CEA concentration in two linear ranges from 0.5 to 15 ng/mL and 15 to 300 ng/mL with a detection limit of 0.1 ng/mL (at 3δ). The precision and reproducibility are acceptable with the intraassay CV of 6.3% and 4.7% at 8 and 60 ng/mL CEA, respectively. The storage stability of the proposed immunosensor is acceptable in a pH 7.0 PBS at 4 °C for 9 days. Moreover, the proposed immunosensors were used to analyze CEA in human serum specimens. Analytical results of clinical samples show the developed immunoassay has a promising alternative approach for detecting CEA in the clinical diagnosis.  相似文献   

7.
In the present study, we developed a novel label‐free capacitance impedimetric immunosensor based on the immobilization of the human monoclonal antibody anti‐interleukin‐10 (anti‐IL‐10 mAb) onto polypyrrole (PPy)‐modified silicon nitride (Si3N4) substrates. The immunosensor was used for the detection of the recombinant interleukin‐10 antigen (rh IL‐10) that may be secreted in patients at the early stage of inflammation. The immunosensor was created by chemical deposition of PPy conducting layer on pyrrole?silane (SPy)‐treated Si/SiO2/Si3N4 substrates (Si/SiO2/Si3N4?SPy), followed by anti‐IL‐10 mAb immobilization through carboxyl‐functionalized diazonium (CMA) protocol and carbodiimide chemistry. The surface characterization and the biofunctionalization steps were characterized by SEM, FTIR and cyclic voltammetry (CV) while the detection process was carried out by using electrochemical impedance spectroscopy (EIS) analyses. The created immunosensor showed two linear fittings (R2=0.999) for the detection of rh IL‐10 within the concentration range from 1–50 pg/mL. It exhibited high sensitivity (0.1128 (pg/mL)?1) with a very low limit of detection (LOD)=0.347 pg/mL, more particularly, at the low concentration range (1–10 pg/mL). Thus, this developed polypyrrole‐based immunosensor represents a promising strategy for creation of miniaturized label‐free, fast and highly sensitive biosensors for diagnosis of inflammation biomarkers at very low concentrations with reduced cost.  相似文献   

8.
Screening and early diagnosis are crucial to increase the success of cancer patients’ treatments and improve the survival rate. To contribute to this success, distinct electrochemical immunosensing platforms were developed for the analysis of the ExtraCellular Domain of the Human Epidermal growth factor Receptor 2 (HER2‐ECD) through sandwich assays on nanomaterial‐modified screen‐printed carbon electrodes (SPCEs). The most promising platforms showed to be SPCEs modified with (i) gold nanoparticles (AuNPs) and (ii) multiwalled carbon nanotubes combined with AuNPs. The antibody‐antigen interaction was detected using a secondary antibody labelled with alkaline phosphatase and 3‐indoxyl phosphate and silver ions as the enzymatic substrate. The electrochemical signal of the enzymatically generated metallic silver was recorded by linear sweep voltammetry. Under the optimized conditions, linear calibration plots were obtained between 7.5 and 50 ng/mL and the total assay time was 2 h 20 min, achieving LODs of 0.16 ng/mL (SPCE‐MWCNT/AuNP) and 8.5 ng/mL (SPCE‐AuNP), which are well below the established cut‐off value of 15 ng/mL for this cancer biomarker.  相似文献   

9.
The first examples of pyrrole‐ and thiophene‐bridged 5,15‐diazaporphyrin (DAP) dimers are prepared through Stille coupling reactions of nickel(II) and copper(II) complexes of 3‐bromo‐10,20‐dimesityl‐5,15‐diazaporphyrin (mesityl=2,4,6‐trimethylphenyl) with the respective 2,5‐bis(tributylstannyl)heteroles. The effects of the heterole spacers and meso nitrogen atoms on the optical, electrochemical, and magnetic properties of the DAP dimers are investigated by UV/Vis absorption spectroscopy, density functional theory calculations, magnetic circular dichroism spectroscopy, cyclic voltammetry, and EPR spectroscopy. The heterole spacers are found to have a significant impact on the electronic transitions over the entire π‐system. In particular, the pyrrole‐bridged DAP dimers exhibit high light‐harvesting potential in the low‐energy visible/near‐infrared region owing to the intrinsic charge‐transfer character of the lowest excitation.  相似文献   

10.
In the present work, a newly functional nanoparticle has been prepared to immobilize the protein for the detection of α‐1‐fetoprotein (AFP). Prussian blue (PB) nanoparticle was initially synthesized under ultrasonic condition, then bovine serum albumin (BSA) was used to coat the PB nanoparticle to improve the stability of the PB nanoparticle as well as functionalize the surface of PB nanoparticle, and then gold colloids were loaded on the BSA‐coated PB nanoparticle to construct a core‐shell‐shell nanostructure via the conjunction of thiolate linkages or alkylamines of the BSA. Finally, a convenient, effective and sensitivity amperometric immunosensor for the detection of α‐1‐fetoprotein (AFP) was constructed by the employment of these functional core‐shell‐shell microspheres. The preparation of the nanoparticle (Au‐BSA‐PB NPs) was characterized by transmission electron microscopy (TEM), and the assembly of the biosensor was characterized with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The dynamic range of the resulted immunosensor for the detection of AFP is from 0.02 ng/mL to 200.0 ng/mL with a detection limit of 0.006 ng/mL (S/N=3). Moreover, this biosensor displays good selectivity, stability and reproducibility.  相似文献   

11.
Presently, bisphenol A (BPA) has been added to the list of substances of very high concern as endocrine disruptors. According to the literature, exposure to bisphenol A even at low doses may result in adverse health effects. In this study, electrochemical sensor of Bisphenol A based on thioether DDT‐Poly(N‐vinylpyrrolidone) oligomer has been developed. The thioether oligomer, which is capable of recognizing BPA, was prepared and used for gold electrode modification. The characterization of the modified gold electrode and the synthesized thioether oligomer were carried out by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), atomic force microscopy (AFM), Fourier‐transform infrared spectroscopy (FTIR), proton nuclear magnetic resonance spectroscopy (1H NMR) and Size exclusion chromatography (SEC). Obtained results indicate that the modified electrode shows good electrochemical activity, good sensitivity and reproducibility for BPA detection. It exhibited a good linear relationship ranging from 1 to 20 pg/mL, and the detection limit was found to be 1.9 pg/mL at S/N=3. Several interfering species such as hydroquinone, phenol and resorcinol were used and their behaviors on the modified gold electrode were investigated.  相似文献   

12.
《Electroanalysis》2017,29(12):2832-2838
In this study, a bimetallic nanomaterial‐based electrochemical immunosensor was developed for the detection of carcinoembryonic antigen (CEA) and vascular endothelial growth factor (VEGF) cancer biomarkers at the same time. CEA and VEGF biomarkers are indicators for colon and breast cancers and stomach cancers, respectively. During the study, gold nanoparticle (AuNp), lead nanoparticle (PbNp), copper nanoparticle (CuNp) and magnetic gamma iron(III)oxide (γFe2O3 Np) were synthesized, characterized and used together for the first time in the structure of an electrochemical biosensor based on anti‐CEA and anti‐VEGF. For this purpose, Au SPE based sandwich immunosensor was fabricated by using labeled anti‐CEA (labeled with Pb+2) and labeled anti‐VEGF (labeled with Cu+2). As a result, CEA and VEGF biomarkers were detected following the oxidation peaks of label metals (Pb+2 and Cu+2) by using differential pulse voltammetry. After the experimental parameters were optimized, the linear range was found in the concentration range between 25 ng/mL and 600 ng/mL with the relative standard deviation (RSD) value of (n=3 for 600 ng/mL) 3.33 % and limit of detection (LOD) value of 4.31 ng/mL for CEA biomarker. On the other hand, the linear range was found in the concentration range between 0.2 ng/mL and 12.5 ng/mL with the RSD value of (n=3 for 12.5 ng/mL) 5.31 % and LOD value of 0.014 ng/mL for VEGF biomarker. Lastly, sample application studies for synthetic plasma sample and interference studies with dopamine, ascorbic acid, BSA, cysteine and IgG were carried out.  相似文献   

13.
In this work an electrochemical immunoassay, based on a direct competitive assay, was developed using magnetic beads as solid phase and carbon screen‐printed arrays as transducers for the detection of sulfonamides in food matrices such as honey. Magnetic beads coated with protein A were modified by immobilisation of specific antibodies and then the competition between the target analyte and the corresponding analyte‐labelled with an enzyme was carried out; after the immunosensing step, beads were captured by a magnet onto the working surfaces of a screen‐printed eight‐electrodes array for a multiple electrochemical detection. Screen‐printed eight‐electrodes arrays were chosen as transducers due to the possibility to repeat multiple analysis and to test different samples simultaneously. Alkaline Phosphatase (AP) was used as enzyme label and Differential Pulse Voltammetry (DPV) as fast electrochemical technique. Calibration curves demonstrate that the developed electrochemical immunoassay was able to detect this class of drugs in standard solutions at low concentrations (ng/mL levels). The short incubation times (25 min) and the fast electrochemical measurement (10 sec) make of these systems a possible alternative to classic ELISA tests.  相似文献   

14.
A potentiometric immunosensor for the label‐free detection of bisphenol A (BPA) was developed by covalently immobilizing a polyclonal antibody (PAb) onto the surface of a carboxylated poly(vinyl chloride) (PVC‐COOH) membrane. The immunosensor was characterized using scanning electron microscopy (SEM), X‐ray photoelectron spectroscopy (XPS), and electrochemical impedance spectroscopy. The immobilization of PAb and its interaction with antigen (Ag) and BPA were also confirmed by quartz crystal microbalance (QCM) studies. Experimental parameters affecting the immuno‐interaction between PAb and its Ag or BPA were examined in terms of pH, antibody concentration, and temperature. The immunosensor showed a specific recognition of BPA with less interference than 4.8% from other common phenolic compounds. A calibration plot was obtained between 1.0 and 30.0 ng/mL and the detection limit was determined to be 0.6 ng/mL. The proposed immunosensor was applied for a real water sample spiked with BPA and the recoveries were in the range between 102.5 and 105.7%.  相似文献   

15.
The highly sensitive determination of ofloxacin (OFL) in human serum and urine was achieved on a novel tryptophan‐graphene oxide‐carbon nanotube (Trp‐GO‐CNT) composite modified glassy carbon electrode (Trp‐GO‐CNT/GCE). The Trp‐GO‐CNT composite was fabricated, and its morphologies and surface functional groups were characterized by field emission scanning electron microscopy (FE‐SEM) and Fourier transform infrared (FT‐IR) spectroscopy. The electrochemical properties of Trp‐GO‐CNT/GCE were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The superior electrochemical behaviors of Trp‐GO‐CNT/GCE toward OFL can be mainly assigned to the excellent electrocatalytic activity of Trp, the great conductivity and high surface area of GO and CNT, and the synergistic effect between Trp, GO and CNT. Under optimum conditions, a wide and valuable linear range (0.01–100 μM), a low detection limit (0.001 μM, S/N=3), a good linear relationship (R2>0.999), good stability and repeatability were obtained for the quantitative determination of OFL. Furthermore, the Trp‐GO‐CNT electrochemical sensor was successfully applied to the determination of OFL in human serum and urine samples, and satisfactory accuracy and recovery could be obtained.  相似文献   

16.
A simple and portable electrochemical immunosensor for the detection of total prostate specific antigen (t‐PSA) in human serum was developed using a double‐layer nanogold particles and dendrimer‐functionalized polyvinyl chloride (PVC) membrane as immunosensing interface. To fabricate such a multifunctional PVC electrode, an o‐phenylenediaminedoped PVC membrane was initially constructed, then nanogold particles and poly(amidoamine) G4‐dendrimer with a sandwich‐type format were assembled onto the PVC membrane surface, and then t‐PSA antibodies (anti‐PSA) were adsorbed on the nanogold surface. The detection principle of the immunosensor is based on the change in the electric potential before and after the antigen‐antibody interaction. The experimental conditions and the factors influencing the performance of the immunosensor were investigated. Under optimal conditions, the proposed immunosensor exhibits good electrochemical behavior in the dynamic range of 0.5–18 ng/mL relative to t‐PSA concentration with a relative low detection limit of 0.1 ng/mL (S/N=3). The precision, reproducibility, and stability of the immunosensor are acceptable. In addition, 43 serum specimens were assayed by the as‐prepared immunosensor, and consistent results were obtained in comparison with those obtained by the standard enzyme‐linked immunosorbent assay (ELISA). Compared with the conventional ELISAs, the developed immunoassay system was simple and rapid without labeling and separation steps. Importantly, the immobilization and detection methodologies could be extended for the immobilization and detection of other biomarkers.  相似文献   

17.
《中国化学会会志》2018,65(6):743-749
A glassy carbon electrode (GCE) modified with a copper‐based metal‐organic framework (MOF) [HKUST‐1, HKUST‐1 = Cu3(BTC)2 (BTC = 1,3,5‐benzenetricarboxylicacid)] was developed as a highly sensitive and simple electrochemical sensor for the determination of dopamine (DA). The MOF was prepared by a hydrothermal process, and the morphology and crystal phase of the MOF were characterized by scanning electron microscopy (SEM) and X‐ray diffraction (XRD), respectively. Meanwhile, the electrochemical performance was investigated using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). Under optimized conditions, the modified electrode showed excellent electrocatalytic activity and high selectivity toward DA. The linear response range was from 5.0 × 10−7 to 1.0 × 10−4 M and the detection limit was as low as 1.5 × 10−7 M. Moreover, the electrochemical sensor was used to detect DA in real samples with excellent results. MOF‐based sensors hold great promise for routine sensing applications in the field of electrochemical sensing.  相似文献   

18.
Enantioselective synthesis of pyrrole‐annulated medium‐sized‐ring compounds by an iridium‐catalyzed allylic dearomatization/retro‐Mannich/hydrolysis sequence is presented. Various substituted pyrrole‐annulated seven‐ and eight‐membered‐ring products were obtained under mild reaction conditions with moderate to good yields and excellent enantioselectivity. Additionally, these products contain a scaffold widely distributed in natural products and biologically active compounds. The current method provides a convenient way for accessing such pyrrole‐anuulated medium‐sized‐ring compounds.  相似文献   

19.
A new electrochemical immunosensing protocol for sensitive detection of alpha‐fetoprotein (AFP, as a model) in human serum was developed by means of immobilization of horseradish peroxidase‐anti‐AFP conjugates (HRP‐anti‐AFP) onto graphene and nanogold‐functionalized biomimetic interfaces. The low‐toxic and high‐conductive graphene complex provided a large capacity for nanoparticulate immobilization and a facile pathway for electron transfer. With a one‐step immunoassay format, the antigen‐antibody complex was formed between the immobilized HRP‐anti‐AFP on the electrode and AFP in the sample. The formed immunocomplex was coated on the electrode surface, inhibited partly the active center of HRP, and decreased the catalytic reduction of HRP toward the enzyme substrate of H2O2. Under optimal conditions, the decrease of reduction currents was proportional to AFP concentration, and the dynamic range was 1.0–10 ng/mL with a relative‐low detection limit (LOD) of 0.7 ng/mL AFP. Intra‐ and inter‐assay coefficients of variation (CVs) were less than 10 %. The assay was evaluated for clinical human serum samples, including 8 (possible) patients with hepatocarcinoma and 3 normal human sera. Correct identification of negative/positive samples and perfect accordance with results from Elecsys 2010 Electrochemiluminescent Automatic Analyzer as a reference was obtained. Importantly, the graphene and nanogold‐based sensor provided a promising platform for the detection of other biocompounds, and could be further applied for development of other potential electrochemical bio/chemosensors.  相似文献   

20.
A headspace solid‐phase microextraction method was developed for the preconcentration and extraction of methyl tert‐butyl ether. An ionic‐liquid‐mediated multiwalled carbon nanotube–poly(dimethylsiloxane) hybrid coating, which was prepared by covalent functionalization of multiwalled carbon nanotubes with hydroxyl‐terminated poly(dimethylsiloxane) using the sol–gel technique, was used as solid‐phase microextraction adsorbent. This innovative fiber exhibited a highly porous surface structure, high thermal stability (at least 320°C) and long lifespan (over 210 uses). Potential factors affecting the extraction efficiency were optimized. Under the optimum conditions, the method LOD (S/N = 3) was 0.007 ng/mL and the LOQ (S/N = 10) was 0.03 ng/mL. The calibration curve was linear in the range of 0.03–200 ng/mL. The RSDs for one fiber (repeatability, n = 5) at three different concentrations (0.05, 1, and 150 ng/mL) were 5.1, 4.2, and 4.6% and for the fibers obtained from different batches (reproducibility, n = 3) were 6.5, 5.9, and 6.3%, respectively. The developed method was successfully applied to the determination of methyl tert‐butyl ether in different real water samples on three consecutive days. The relative recoveries for the spiked samples with 0.05, 1, and 150 ng/mL were between 94–104%.  相似文献   