首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A robust and sensitive method was developed for the enantiomeric analysis of six chiral pesticides (including metalaxyl, epoxiconazole, myclobutanil, hexaconazole, napropamide, and isocarbophos) in aquatic environmental samples. The optimized chromatographic conditions for the quantification of all the 12 enantiomers were performed with Chiralcel OD‐RH column using mobile phase consisting of 0.1% aqueous formic acid and acetonitrile operated under reversed‐phase conditions and then analyzed using liquid chromatography with tandem mass spectrometry. Twelve enantiomers were detected in multiple reaction monitoring mode. Solid‐phase extraction and dispersive liquid–liquid microextraction were employed in this study. Response surface methodology was applied to assist in the dispersive liquid–liquid microextraction optimization. Under the optimum conditions, recoveries of pesticides enantiomers varied from 83.0 to 103.2% at two spiked levels with relative standard deviation less than 11.5%. The concentration factors were up to 1000 times. Method detection and quantification limits varied from 0.11 to 0.48 ng/L and from 0.46 to 1.49 ng/L, respectively. Finally, this method was used to determination of the enantiomers composition of the six pesticides in environmental aqueous matrices, which will help better understand the behavior of individual enantiomer and make accurate risk assessment to ecosystems.  相似文献   

2.
A sensitive, accurate and reliable bioanalytical method for the enantioselective determination of metoprolol in plasma and saliva samples utilizing liquid chromatography–electrospray ionization tandem mass spectrometry was developed and validated. Human plasma and saliva samples were pretreated by microextraction by packed sorbent (MEPS) prior to analysis. A new MEPS syringe form with two inputs was used. Metoprolol enantiomers and internal standard pentycaine (IS) were eluted from MEPS sorbent using isopropanol after removal of matrix interferences using aliquots of 5% methanol in water. Complete separation of metoprolol enantiomers was achieved on a Cellulose‐SB column (150 × 4.6 mm, 5 μm) using isocratic elution with mobile phase 0.1% ammonium hydroxide in hexane–isopropanol (80:20, v/v) with a flow rate of 0.8 mL/min. A post‐column solvent‐assisted ionization was applied to enhance metoprolol ionization signal in positive mode monitoring (+ES) using 0.5% formic acid in isopropanol at a flow rate of 0.2 mL/min. The total chromatographic run time was 10 min for each injection. The detection of metoprolol in plasma and saliva samples was performed using triple quadrupole tandem mass spectrometer in +ES under the following mass transitions: m/z 268.08 → 72.09 for metoprolol and m/z 303.3 → 154.3 for IS. The linearity range was 2.5–500 ng/mL for both R‐ and S‐metoprolol in plasma and saliva. The limits of detection and quantitation for both enantiomers were 0.5 and 2.5 ng/mL respectively, in both matrices (plasma and saliva). The intra‐ and inter‐day precisions were presented in terms of RSD values for replicate analysis of quality control samples and were <5%; the accuracy of determinations varied from 96 to 99%. The method was able to determine the therapeutic levels of metoprolol enantiomers in both human plasma and saliva samples successfully, which can aid in therapeutic drug monitoring in clinical laboratories. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
A rapid and sensitive analytical method based on liquid chromatography coupled to tandem mass spectrometry detection with positive ion electrospray ionization was developed for the determination of febuxostat in human plasma using d7‐febuxostat as the internal standard (IS). A simple protein precipitation was performed using acetonitrile. The analyte and IS were subjected to chromatographic analysis on a Capcell PAK C18 column (4.6 × 100 mm, 5 µm) using acetonitrile–5 mm ammonium acetate–formic acid (85:15:0.015, v/v/v) as the mobile phase at a flow rate of 0.6 mL/min. An Agilent 6460 electrospray tandem mass spectrometer was operated in the multiple reaction monitoring mode. The precursor‐to‐product ion transitions m/z 317 → m/z 261 (febuxsotat) and m/z 324 → m/z (261 + 262) (d7‐febuxostat, IS) were used for quantitation. The results were linear over the studied range (10.0–5000 ng/mL), and the total analysis time for each chromatograph was 3 min. The intra‐ and inter‐day precisions were less than 7.9 and 7.2%, respectively, and the accuracy was within ±4.2%. No evidence of analyte instability in human plasma was observed storage at ?20°C for 31 days. This method was successfully applied in the determination of febuxostat concentrations in plasma samples from healthy Chinese volunteers. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
A rapid and sensitive liquid chromatography–isotope dilution tandem mass spectrometry method was developed and validated for quantification of itraconazole (ITZ) and its active metabolite hydroxyitraconazole (OH‐ITZ ) in human plasma. The plasma samples were extracted with tert‐butyl methyl ether and two isotope‐labeled internal standards (D5‐itraconazole and D5‐hydroxyitraconazole) were used. The chromatographic separation was performed on a Capcell Pak C18 MG III (100 × 2 mm, 5 µm, Shiseido). The protonated ions of analytes were detected in positive ionization in multiple reaction monitoring mode. The plasma method has a lower limit of quantification of 1 ng/mL with a linearity range of 1–500 ng/mL for ITZ and OH‐ITZ using 100 µL of plasma. The recoveries of the method were found to be 69.47–71.98% for ITZ and 75.68–82.52% for OH‐ITZ. The intra‐ and inter‐batch precision was less than 11% for all quality control samples at concentrations of 2.5, 200 and 400 ng/mL. These results indicate that the method was efficient with a short run time (4.5 min) and acceptable accuracy, precision and sensitivity.The validated method was successfully applied to analysis of human plasma samples in pharmacokinetics study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
A simple, sensitive and reproducible ultra‐performance liquid chromatography–tandem mass spectrometry method has been developed for the simultaneous determination of atenolol, a β‐adrenergic receptor‐blocker and chlorthalidone, a monosulfonamyl diuretic in human plasma, using atenolol‐d7 and chlorthalidone‐d4 as the internal standards (ISs). Following solid‐phase extraction on Phenomenex Strata‐X cartridges using 100 μL human plasma sample, the analytes and ISs were separated on an Acquity UPLC BEH C18 (50 mm × 2.1 mm, 1.7 µm) column using a mobile phase consisting of 0.1% formic acid–acetonitrile (25:75, v/v). A tandem mass spectrometer equipped with electrospray ionization was used as a detector in the positive ionization mode for both analytes. The linear concentration range was established as 0.50–500 ng/mL for atenolol and 0.25–150 ng/mL for chlorthalidone. Extraction recoveries were within 95–103% and ion suppression/enhancement, expressed as IS‐normalized matrix factors, ranged from 0.95 to 1.06 for both the analytes. Intra‐batch and inter‐batch precision (CV) and accuracy values were 2.37–5.91 and 96.1–103.2%, respectively. Stability of analytes in plasma was evaluated under different conditions, such as bench‐top, freeze–thaw, dry and wet extract and long‐term. The developed method was superior to the existing methods for the simultaneous determination of atenolol and chlorthalidone in human plasma with respect to the sensitivity, chromatographic analysis time and plasma volume for processing. Further, it was successfully applied to support a bioequivalence study of 50 mg atenolol + 12.5 mg chlorthalidone in 28 healthy Indian subjects. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
建立正相液相色谱-串联质谱(LC-MS/MS)分离普萘洛尔对映体的方法,并用于盐酸普萘洛尔片对映体含量测定.样品使用甲醇进行简单提取,采用Chiralcel OD-H手性柱,以正己烷-乙醇-氨水(70∶30∶0.4, v/v/v)为流动相,流速为0.4 mL/min.在正离子模式下,通过电喷雾离子化(ESI+),采用多...  相似文献   

7.
Homoegonol is a biologically active neolignan isolated from Styrax species with cytotoxic, antimicrobial, anti‐inflammatory and anti‐asthma activities. For the quantification of homoegonol in rat plasma, a selective and sensitive liquid chromatography–tandem mass spectrometric method was developed and validated for the first time using protein precipitation with methanol as a sample clean‐up procedure. The analytes were separated in an Atlantis dC18 column using a gradient elution of methanol and 0.1% formic acid, and mass‐to‐charge ratios were determined in selective reaction monitoring mode using tandem mass spectrometry with m/z 343.12 > 296.97 for homoegonol and m/z 517.30 > 282.90 for udenafil (internal standard). The standard curve was linear over the concentration ranges of 1 ? 500 ng/mL using a 30 μL rat plasma sample. The coefficient of variation and relative error for intra‐ and inter‐assay at four quality control levels were 3.9–10.0 and ‐3.3–2.7%, respectively. The overall recovery of homoegonol from rat plasma using protein precipitation was 99.7 ± 7.7%. The pharmacokinetics parameters of homoegonol were dose‐independent after both intravenous (1, 2.5 and 5 mg/kg doses) and oral (5, 10 and 20 mg/kg doses) administration in male Sprague–Dawley rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
A rapid and sensitive method for the simultaneous confirmatory analysis of three forensic most relevant cannabinoids, Delta(9)-tetrahydrocannabinol (THC), 11-hydroxy-Delta(9)-tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH), by means of high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in human plasma was developed and fully validated. Sample clean-up was performed by automated silica-based solid-phase extraction and the separation was carried out using a PhenylHexyl column (50 x 2 mm i.d., 3 micro m) and acetonitrile-5 mM ammonium acetate gradient elution. Data were acquired with an API 3000 LC/MS/MS system equipped with a turboionspray interface and triple quadrupole mass analyzer using positive electrospray ionization and multiple reaction monitoring. Two MS/MS transitions for each substance were monitored and deuterated analogues of analytes were used as internal standards for quantitation. The limit of quantitation was 0.8 ng ml(-1) for THC, 0.8 ng ml(-1) for 11-OH-THC and 4.3 ng ml(-1) for THC-COOH and linearity with a correlation coefficient r(2) = 0.999 was achieved up to 100 ng ml(-1) for THC and 11-OH-THC and 500 ng ml(-1) for THC-COOH. The limits of detection were 0.2 ng ml(-1) for THC, 0.2 ng ml(-1) for 11-OH-THC and 1.6 ng ml(-1) for THC-COOH. The developed LC/MS/MS method was also successfully used for the determination of THC-COOH-glucuronide, the phase II metabolite of THC-COOH.  相似文献   

9.
Cyadox is a novel antimicrobial growth‐promoter of the quinoxalines. For food safety and pharmacokinetic studies, a convenient, sensitive and reproducible LC‐ESI‐MS/MS method was developed for the simultaneous determination of cyadox and its major metabolites, quinoxaline‐2‐carboxylic acid, 1,4‐bisdesoxycyadox, cyadox‐1‐monoxide and cyadox‐4‐monoxide in chicken plasma. Plasma sample was subjected to a simple deproteinisation with acetonitrile. Analysis was performed on a C18 column by detection with mass spectrometry in multiple reaction monitoring mode. A gradient elution program with 0.2% formic acid, methanol and acetonitrile was performed at a flow rate of 0.2 mL/min. The decision limits (CCαs) of five analytes in plasma ranged from 1.0 to 4.0 μg/L, and the detection capabilities (CCβs) were <10 μg/L. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The extraction recoveries of five analytes were between 87.4 and 93.9% in plasma at the spiked levels of 5 (10)–200 μg/L with the relative standard deviations <10% for each analyte. The developed method demonstrated a satisfactory applicability in real plasma samples.  相似文献   

10.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

11.
Ketamine is an N‐methyl‐d ‐aspartate receptor antagonist that is usually used clinically as a racemic mixture. Its two enantiomers exhibit different pharmacological activities. To determine whether the enantiomers have different pharmacokinetic profiles, a chiral liquid chromatography–tandem mass spectrometry method was developed and validated for the determination of ketamine enantiomers in dog plasma. The enantiomers of ketamine were extracted from 50 μL of plasma by methyl tert‐butyl ether. Adequate chromatographic retention and baseline resolution of the enantiomers were achieved within a runtime of 5 min on a chiral column coated with polysaccharide derivatives, using a gradient mobile phase of acetonitrile and 10 mm ammonium bicarbonate aqueous solution. Ketamine enantiomers were detected by mass spectrometry with multiple reaction monitoring mode using the transitions of m/z 238.3 → 125.9 for the analytes and m/z 237.1 → 194.1 for carbamazepine (internal standard). The method was linear over the concentration range from 0.5 to 500 ng/mL for each enantiomer. The lower limit of quantification (LLOQ) for each enantiomer was 0.5 ng/mL. The intra‐ and inter‐day precision was <7.3% and 8.5% for R‐ and S‐ketamine, respectively. The accuracy was 92.9–110.4% for R‐ketamine and 99.8–102.4% for S‐ketamine. The method was successfully applied to characterize the stereoselective pharmacokinetic profiles of ketamine in beagle dogs.  相似文献   

12.
Sildenafil is used to treat pulmonary hypertension in neonatal and pediatric patients. Pharmacokinetic studies in these patients are complicated by the limited sample volume. We present the validation results of an assay method to quantitate sildenafil and desmethylsildenafil simultaneously in 50 µL of plasma. Deuterated sildenafil was used as an internal standard. After liquid–liquid extraction, analytes were separated on an ultra‐performance liquid chromatography (UPLC)‐column and quantified via tandem mass spectrometry. The calibration range was linear, with acceptable accuracy and a precision of <15% for both compounds. The lower limits of quantification were 1 ng/mL. Matrix effects were present, but inter‐plasma batch variability was under 12%. The method was successfully applied to samples from a pharmacokinetic study into sildenafil pharmacokinetics in neonates, making maximum use of the limited number and amount of plasma samples available. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
HIV protease inhibitors are important antiretroviral drugs which have substantially reduced the morbidity and mortality associated with HIV-1 infection. Recent data have shown relationships between plasma concentrations of the protease inhibitors and clinical response, which makes therapeutic drug monitoring valuable. We have developed and validated an assay, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS), for the routine quantification of the six licensed protease inhibitors (amprenavir, indinavir, lopinavir, nelfinavir, ritonavir and saquinavir) and the pharmacologically active nelfinavir metabolite M8 in plasma. The sample pretreatment consisted of protein precipitation with a mixture of methanol and acetronitrile using only 100 microl of plasma. Chromatographic separation was performed on an Inertsil ODS3 column (50 x 2.0 mm i.d., particle size 5 microm), with a quick stepwise gradient using an acetate buffer (pH 5) and methanol, at a flow rate of 0.5 ml min(-1). The analytical run time was 5.5 min. The use of a 96-well plate autosampler allowed batch sizes up to 150 patient samples. The triple-quadrupole mass spectrometer was operated in the positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges 0.01-10 microg ml(-1) for indinavir and saquinavir, 0.1-10 microg ml(-1) for amprenavir, 0.05-10 microg ml(-1) for nelfinavir and ritonavir, 0.1-20 microg ml(-1) for lopinavir and 0.01-5 microg ml(-1) for M8. Saquinavir-d(5) and indinavir-d(6) were used as internal standards. The coefficients of variation were always <10% for both intra-day and inter-day precisions for each compound. Mean accuracies were also between the designated limits (+/-15%). The validated concentration ranges proved to be adequate in daily practice. This robust and fast LC/MS/MS assay is now successfully applied for routine therapeutic drug monitoring and pharmacokinetic studies in our hospital.  相似文献   

14.
An LC‐MS/MS method for determination of the anti‐epileptic drug topiramate (TPM) in dried blood spot (DBS) samples was developed and validated. DBS samples were prepared by spotting 30 μL of spiked whole blood onto FTATM DMPK‐C cards and drying for at least 3 h. Six‐millimetre punched spots were then extracted by using a mixture of methanol and water (90:10, v/v) with deuterated internal standard (topiramate‐d12). The extracted samples were injected into a liquid chromatograph equipped with a tandem mass spectrometric detector. Negative ions were monitored in the selected reaction monitoring mode and transitions m/z 338.2 → 78.1 and m/z 350.3 → 78.1 were used for the quantitative evaluation of TPM and internal standard, respectively. The results obtained from validation were statistically evaluated according to the requirements of the European Medicines Agency and US Food and Drug Administration regulatory guidelines. The linearity of the method was checked within a concentration range from 10 to 2000 ng/mL. The validation results indicate that the method is accurate, precise, sensitive, selective and reproducible. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
We describe a novel method for the determination of three kinds of dimethylbenzylmercapturic acids (DMM) and six kinds of dimethylhippuric acids (DMH), found in urine as metabolites of trimethylbenzenes, based on liquid chromatography/electrospray ionization tandem mass spectrometry. A solid-phase extraction procedure was used for the extractions of DMM and DMH from a urine sample, and the separation was performed on a reversed-phase C(30) column. The analytes were ionized by electrospray in the positive-ion mode. Operating in the multiple reaction monitoring mode, the linearity of the relative mass spectrometric responses to the internal standard versus analyte concentrations were established in the range 0.1-100 ng ml(-1). The extraction procedure was rapid and the relative standard deviations were below 5%. The detection limits of DMM and DMH in the urine by the proposed method were in the ranges 0.26-0.41 and 0.42-2.0 ng l(-1), respectively. Furthermore, DMM and DMH were detected in a urine sample from an individual who did not suffer from occupational exposure to trimethylbenzenes, by using this method.  相似文献   

16.
The relationships between the ionization profile, sensitivity, and structures of 64 exogenous anabolic steroids (groups I–IV) was investigated under electrospray ionization (ESI) conditions. The target analytes were ionized as [M + H]+ or [M + H–nH2O]+ in the positive mode, and these ions were used as precursor ions for selected reaction monitoring analysis. The collision energy and Q3 ions were optimized based on the sensitivity and selectivity. The limits of detection (LODs) were 0.05–20 ng/mL for the 64 steroids. The LODs for 38 compounds, 14 compounds and 12 compounds were in the range of 0.05–1, 2–5 and 10–20 ng/mL, respectively. Steroids including the conjugated keto‐functional group at C3 showed good proton affinity and stability, and generated the [M + H]+ ion as the most abundant precursor ion. In addition, the LODs of steroids using the [M + H]+ ion as the precursor ion were mostly distributed at low concentrations. In contrast, steroids containing conjugated/unconjugated hydroxyl functional groups at C3 generated [M + H ? H2O]+ or [M + H ? 2H2O]+ ions, and these steroids showed relatively high LODs owing to poor stability and multiple ion formation. An LC‐MS/MS method based on the present ionization profile was developed and validated for the determination of 78 steroids (groups I–V) in human urine. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
An efficient enantioselective method for the simultaneous determination of isocarbophos and its main metabolite isocarbophos oxon in rice, soil, and water was developed using liquid chromatography with tandem mass spectrometry. The enantioseparation was performed on a Chiralpak AD‐3R column at 30°C using gradient elution. Target compounds were extracted from soil and rice using acetonitrile with omission of a clean‐up procedure, while a C18 solid‐phase extraction column was used for water samples. Quantification was achieved using matrix‐matched calibration. The overall mean recoveries for isocarbophos and isocarbophos oxon enantiomers from the five matrices were 89.7–103 and 90.1–98.7%, with relative standard deviations of 2.1–5.4 and 2.5–4.7%, respectively. Moreover, the absolute configurations of isocarbophos oxon enantiomers were determined by liquid chromatography with tandem mass spectrometry through incubation of each isocarbophos enantiomer in soil, the first eluting enantiomer being confirmed as (R)‐(?)‐isocarbophos oxon. The proposed method was applied to real soil samples and satisfactory results were obtained.  相似文献   

18.
Oleuropein (OE) is the cardinal bioactive compound derived from Olea europaea and possesses numerous beneficial properties for human health. However, despite the plethora of analytical methods that have studied the biological fate of olive oil‐derived bioactive compounds, no validated methodology has been published to date for the simultaneous determination of OE, along with all its major metabolites. In this study, a liquid chromatography‐electrospray ionization‐tandem mass spectrometry (LC‐ESI MS/MS) method has been developed and validated for the quantification of OE, simultaneously with its main metabolites hydroxytyrosol, 2‐(3,4‐dihydroxyphenyl)acetic acid, 4‐(2‐hydroxyethyl)‐2‐methoxy‐phenol or homovanillyl alcohol, 2‐(4‐hydroxy‐3‐methoxyphenyl)acetic acid or homovanillic acid, and elenolic acid in rat plasma matrix. Samples were analyzed by LC‐ESI MS/MS prior to and after enzymatic treatment. A solid‐phase extraction step with high mean recovery for all compounds was performed as sample pretreatment. Calibration curves were linear for all bioactive compounds over the range studied, while the method exhibited good accuracy, intra‐ and inter‐day precision. The limit of detection was in the picogram range (per milliliterof plasma) for HT and OE and in the nanogram range (per milliliter of plasma) for the other analytes, and the method was simple and rapid. The developed methodology was successfully applied for the simultaneous quantification of OE and its aforementioned metabolites in rat plasma samples, thus demonstrating its suitability for pharmacokinetics, as well as bioavailability and metabolism studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
A rapid, sensitive and specific method to quantify nevirapine in human plasma using dibenzepine as the internal standard (IS) was developed and validated. The method employed a liquid-liquid extraction. The analyte and the IS were chromatographed on a C(18) analytical column, (150 x 4.6 mm i.d. 4 microm) and analyzed by tandem mass spectrometry in the multiple reaction monitoring mode. The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 10-5000 ng ml(-1) (r(2) > 0.9970). The between-run precision, based on the relative standard deviation for replicate quality controls was 1.3% (30 ng ml(-1)), 2.8% (300 ng ml(-1)) and 3.6% (3000 ng ml(-1)). The between-run accuracy was 4.0, 7.0 and 6.2% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two nevirapine tablet formulations (Nevirapina from Far-Manguinhos, Brazil, as a test formulation, and Viramune from Boehringer Ingelheim do Brasil Química e Farmacêutica, as a reference formulation) in 25 healthy volunteers of both sexes who received a single 200 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Nevirapina/Viramune was 96.4-104.5% for AUC((0-last)), 91.4-105.1% for AUC((0-infinity)) and 95.3-111.6% for C(max) (AUC = area under the curve; C(max) = peak plasma concentration). Since both 90% CI for AUC((0-last)) and AUC((0-infinity)) and C(max) were included in the 80-125% interval proposed by the US Food and Drug Administration, Nevirapina was considered bioequivalent to Viramune according to both the rate and extent of absorption.  相似文献   

20.
In this study, a reliable ultra‐performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method coupled with an easy, fast and effective sample pretreatment procedure was developed for simultaneous determination of amitraz, chlordimeform, formetanate and their metabolites in human blood. With the procedures of protein precipitation and a phospholipid‐removal step, the endogenous compound interference was significantly reduced, and matrix effects were significantly reduced. The linear ranges of matrix‐matched standard curves were from 0.5 to 1000 ng/mL with coefficients of determination >0.996. Very low limits of detection (0.05–0.12 ng/mL) and limits of quantitation (0.15–0.4 ng/mL) were achieved. Reasonable recoveries ranging from 88.1 to 103.5% were obtained. The intra‐day RSDs ranging from 3.2 to 8.6% and inter‐day RSDs ranging from 4.8 to 9.2% indicated good precision. With the introduction of a phospholipid‐removal step, the ME ranged from 90.1 to 98.5%. The established method was successfully applied to the analysis of a blood sample from a formetanate poisoning case. This method possesses the advantages of high sensitivity, reduced matrix effects and rapidity.  相似文献   