首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
    
A robust and sensitive method was developed for the enantiomeric analysis of six chiral pesticides (including metalaxyl, epoxiconazole, myclobutanil, hexaconazole, napropamide, and isocarbophos) in aquatic environmental samples. The optimized chromatographic conditions for the quantification of all the 12 enantiomers were performed with Chiralcel OD‐RH column using mobile phase consisting of 0.1% aqueous formic acid and acetonitrile operated under reversed‐phase conditions and then analyzed using liquid chromatography with tandem mass spectrometry. Twelve enantiomers were detected in multiple reaction monitoring mode. Solid‐phase extraction and dispersive liquid–liquid microextraction were employed in this study. Response surface methodology was applied to assist in the dispersive liquid–liquid microextraction optimization. Under the optimum conditions, recoveries of pesticides enantiomers varied from 83.0 to 103.2% at two spiked levels with relative standard deviation less than 11.5%. The concentration factors were up to 1000 times. Method detection and quantification limits varied from 0.11 to 0.48 ng/L and from 0.46 to 1.49 ng/L, respectively. Finally, this method was used to determination of the enantiomers composition of the six pesticides in environmental aqueous matrices, which will help better understand the behavior of individual enantiomer and make accurate risk assessment to ecosystems.  相似文献   

2.
建立正相液相色谱-串联质谱(LC-MS/MS)分离普萘洛尔对映体的方法,并用于盐酸普萘洛尔片对映体含量测定.样品使用甲醇进行简单提取,采用Chiralcel OD-H手性柱,以正己烷-乙醇-氨水(70∶30∶0.4, v/v/v)为流动相,流速为0.4 mL/min.在正离子模式下,通过电喷雾离子化(ESI+),采用多...  相似文献   

3.
    
A comparative study of chiral separation of pantoprazole and rabeprazole is carried out using supercritical fluid chromatography and high-performance liquid chromatography. The columns used were Chiralpak IA and Chiralpak IE. The best mobile phase in supercritical fluid chromatography was carbon dioxide-0.2% triethylamine in methanol (60:40) and 0.1% triethylamine in n-hexane-ethanol (50:50) in high-performance liquid chromatography. For supercritical fluid chromatography, values of the retention factor of pantoprazole enantiomers were 3.97 and 4.88. These values for rabeprazole enantiomers were 6.10 and 7.52. The values of separation and resolution factor for pantoprazole and rabeprazole were 1.23 and 1.23 and 2.20 and 3.36, respectively. Similarly, for high-performance liquid chromatography, the values of retention factor for enantiomers of pantoprazole were 4.02 and 7.32. These values for rabeprazole enantiomers were 5.32 and 7.88, respectively. The values of separation and resolution factor for pantoprazole and rabeprazole were 1.82 and 1.48 and 9.22 and 6.58, respectively. A comparison was carried out, which confirmed supercritical fluid chromatography as the best method due to its fastness, eco-friendly, and inexpensiveness. The reported methods are effective, efficient, and reproducible and may be used to separate and identify pantoprazole and rabeprazole in any unknown samples.  相似文献   

4.
HIV protease inhibitors are important antiretroviral drugs which have substantially reduced the morbidity and mortality associated with HIV-1 infection. Recent data have shown relationships between plasma concentrations of the protease inhibitors and clinical response, which makes therapeutic drug monitoring valuable. We have developed and validated an assay, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS), for the routine quantification of the six licensed protease inhibitors (amprenavir, indinavir, lopinavir, nelfinavir, ritonavir and saquinavir) and the pharmacologically active nelfinavir metabolite M8 in plasma. The sample pretreatment consisted of protein precipitation with a mixture of methanol and acetronitrile using only 100 microl of plasma. Chromatographic separation was performed on an Inertsil ODS3 column (50 x 2.0 mm i.d., particle size 5 microm), with a quick stepwise gradient using an acetate buffer (pH 5) and methanol, at a flow rate of 0.5 ml min(-1). The analytical run time was 5.5 min. The use of a 96-well plate autosampler allowed batch sizes up to 150 patient samples. The triple-quadrupole mass spectrometer was operated in the positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges 0.01-10 microg ml(-1) for indinavir and saquinavir, 0.1-10 microg ml(-1) for amprenavir, 0.05-10 microg ml(-1) for nelfinavir and ritonavir, 0.1-20 microg ml(-1) for lopinavir and 0.01-5 microg ml(-1) for M8. Saquinavir-d(5) and indinavir-d(6) were used as internal standards. The coefficients of variation were always <10% for both intra-day and inter-day precisions for each compound. Mean accuracies were also between the designated limits (+/-15%). The validated concentration ranges proved to be adequate in daily practice. This robust and fast LC/MS/MS assay is now successfully applied for routine therapeutic drug monitoring and pharmacokinetic studies in our hospital.  相似文献   

5.
A sensitive, accurate and reliable bioanalytical method for the enantioselective determination of metoprolol in plasma and saliva samples utilizing liquid chromatography–electrospray ionization tandem mass spectrometry was developed and validated. Human plasma and saliva samples were pretreated by microextraction by packed sorbent (MEPS) prior to analysis. A new MEPS syringe form with two inputs was used. Metoprolol enantiomers and internal standard pentycaine (IS) were eluted from MEPS sorbent using isopropanol after removal of matrix interferences using aliquots of 5% methanol in water. Complete separation of metoprolol enantiomers was achieved on a Cellulose‐SB column (150 × 4.6 mm, 5 μm) using isocratic elution with mobile phase 0.1% ammonium hydroxide in hexane–isopropanol (80:20, v/v) with a flow rate of 0.8 mL/min. A post‐column solvent‐assisted ionization was applied to enhance metoprolol ionization signal in positive mode monitoring (+ES) using 0.5% formic acid in isopropanol at a flow rate of 0.2 mL/min. The total chromatographic run time was 10 min for each injection. The detection of metoprolol in plasma and saliva samples was performed using triple quadrupole tandem mass spectrometer in +ES under the following mass transitions: m/z 268.08 → 72.09 for metoprolol and m/z 303.3 → 154.3 for IS. The linearity range was 2.5–500 ng/mL for both R‐ and S‐metoprolol in plasma and saliva. The limits of detection and quantitation for both enantiomers were 0.5 and 2.5 ng/mL respectively, in both matrices (plasma and saliva). The intra‐ and inter‐day precisions were presented in terms of RSD values for replicate analysis of quality control samples and were <5%; the accuracy of determinations varied from 96 to 99%. The method was able to determine the therapeutic levels of metoprolol enantiomers in both human plasma and saliva samples successfully, which can aid in therapeutic drug monitoring in clinical laboratories. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
A rapid and sensitive method for the simultaneous confirmatory analysis of three forensic most relevant cannabinoids, Delta(9)-tetrahydrocannabinol (THC), 11-hydroxy-Delta(9)-tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH), by means of high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in human plasma was developed and fully validated. Sample clean-up was performed by automated silica-based solid-phase extraction and the separation was carried out using a PhenylHexyl column (50 x 2 mm i.d., 3 micro m) and acetonitrile-5 mM ammonium acetate gradient elution. Data were acquired with an API 3000 LC/MS/MS system equipped with a turboionspray interface and triple quadrupole mass analyzer using positive electrospray ionization and multiple reaction monitoring. Two MS/MS transitions for each substance were monitored and deuterated analogues of analytes were used as internal standards for quantitation. The limit of quantitation was 0.8 ng ml(-1) for THC, 0.8 ng ml(-1) for 11-OH-THC and 4.3 ng ml(-1) for THC-COOH and linearity with a correlation coefficient r(2) = 0.999 was achieved up to 100 ng ml(-1) for THC and 11-OH-THC and 500 ng ml(-1) for THC-COOH. The limits of detection were 0.2 ng ml(-1) for THC, 0.2 ng ml(-1) for 11-OH-THC and 1.6 ng ml(-1) for THC-COOH. The developed LC/MS/MS method was also successfully used for the determination of THC-COOH-glucuronide, the phase II metabolite of THC-COOH.  相似文献   

7.
The alkylating agents cyclophosphamide (CP) and N, N', N"-triethylenethiophosphoramide (thiotepa) are often co-administered in high-dose chemotherapy regimens. Since these regimens can be complicated by the occurrence of severe and sometimes life-threatening toxicities, pharmacokinetically guided administration of these compounds, to reduce variability in exposure, may lead to improved tolerability. For rapid dose adaptations during a chemotherapy course, we have developed and validated an assay, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS), for the routine quantification of CP, thiotepa and their respective active metabolites 4-hydroxycyclophosphamide (4OHCP) and N, N', N"-triethylenephosphoramide (tepa) in plasma. Because of the instability of 4OHCP in plasma, the compound is derivatized with semicarbazide (SCZ) immediately after sample collection and quantified as 4OHCP-SCZ. Sample pretreatment consisted of protein precipitation with a mixture of methanol and acetronitrile using 100 microl of plasma. Chromatographic separation was performed on an Zorbax Extend C18 column (150 x 2.1 mm i.d., particle size 5 microm), with a quick gradient using 1 mM ammonia solution and acetonitrile, at a flow-rate of 0.4 ml min(-1). The analytical run time was 10 min. The triple quadrupole mass spectrometer was operating in the positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges 200-40,000 ng ml(-1) for CP, 50-5000 ng ml(-1) for 4OHCP-SCZ and 5-2500 ng ml(-1) for thiotepa and tepa, using 100 microl of human plasma. These dynamic concentration ranges proved to be relevant in daily practice. Hexamethylphosphoramide was used as an internal standard. The coefficients of variation were <12% for both intra-day and inter-day precisions for each compound. Mean accuracies were also between the designated limits (+/- 15%). This robust and rapid LC/MS/MS assay is now successfully applied for routine therapeutic drug monitoring of CP, thiotepa and their metabolites in our hospital.  相似文献   

8.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory.  相似文献   

9.
A rapid, sensitive and specific method to quantify nevirapine in human plasma using dibenzepine as the internal standard (IS) was developed and validated. The method employed a liquid-liquid extraction. The analyte and the IS were chromatographed on a C(18) analytical column, (150 x 4.6 mm i.d. 4 microm) and analyzed by tandem mass spectrometry in the multiple reaction monitoring mode. The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 10-5000 ng ml(-1) (r(2) > 0.9970). The between-run precision, based on the relative standard deviation for replicate quality controls was 1.3% (30 ng ml(-1)), 2.8% (300 ng ml(-1)) and 3.6% (3000 ng ml(-1)). The between-run accuracy was 4.0, 7.0 and 6.2% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two nevirapine tablet formulations (Nevirapina from Far-Manguinhos, Brazil, as a test formulation, and Viramune from Boehringer Ingelheim do Brasil Química e Farmacêutica, as a reference formulation) in 25 healthy volunteers of both sexes who received a single 200 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Nevirapina/Viramune was 96.4-104.5% for AUC((0-last)), 91.4-105.1% for AUC((0-infinity)) and 95.3-111.6% for C(max) (AUC = area under the curve; C(max) = peak plasma concentration). Since both 90% CI for AUC((0-last)) and AUC((0-infinity)) and C(max) were included in the 80-125% interval proposed by the US Food and Drug Administration, Nevirapina was considered bioequivalent to Viramune according to both the rate and extent of absorption.  相似文献   

10.
Aspartame is a widely used sweetener,the long-term safety of which has been controversial ever since it was accepted for human consumption.It is unstable and can produce some harmful degradation products under certain storage conditions.A high-performance liquid chromatography/tandem mass spectrometry method was developed for the simultaneous analysis of aspartame and its four degradation products,including aspartic acid,phenylalanine,aspartyl-phenylalanine and 5-benzyl-3,6-dioxo-2-piperazieacetic acid in water and in diet soft drinks.Aspartame and its four degradation products were quantified by a matrix matched external standard calibration curve with excellent correlation coefficients.The limits of detection were 0.16–5.8 mg/L,which exhibited higher sensitivity than common methods.This method was rapid,sensitive,specific and capable of eliminating matrix interferences.It was also applied to the study of the degradation of aspartame at various pH and temperatures.The results indicated that aspartame was partly degraded under strong acidic or basic conditions and the extent of degradation increased with increasing temperature.  相似文献   

11.
A liquid chromatographic/tandem mass spectrometric method is described for the determination of phencyclidine (PCP) in small volumes of rat serum (e.g. 50 microl). Samples were extracted using a mixed-mode strong cation-exchange column and then separated isocratically using a narrow-bore (2.1 mm i.d.) 3 microm Hypersil phenyl column and a mobile phase consisting of an ammonium formate buffer (pH 2.7) with 60% (v/v) methanol. Detection was accomplished using positive ion electrospray ionization in the multiple reaction monitoring mode. Mass spectra were obtained and peaks were observed at an m/z (% abundance) of 244 (100), 159 (25), and 86 (89). Tandem mass spectra were also obtained from the m/z 244 precursor ion with peaks observed at m/z 159 (100), 86 (96), and 91 (11). Optimum serum PCP sensitivity and precision were obtained at a transition of m/z 244 --> 159. Matrix-associated ion suppression did not significantly affect the accuracy (100-112%) or precision (CV < or =8%) of the assay. The lower limit of quantitation was 1 ng ml(-1) in 50 microl of serum. The method was used to study the serum pharmacokinetics of PCP in rats after an intravenous bolus dose of PCP.  相似文献   

12.
Houttuynin (decanoyl acetaldehyde), a beta-dicarbonyl compound, is the major antibacterial constituent in the volatile oil of Houttuynina cordata Thunb. In the present work, detection of houttuynin in human plasma based on the chemical derivatization with 2,4-dinitrophenylhydrazine (DNPH) coupled with liquid chromatography/tandem mass spectrometry was described. The primary reaction products between the beta-dicarbonyl compound and DNPH in aqueous phase were identified as heterocyclic structures, of which the mass spectrometric ionization and fragmentation behavior were characterized with the aid of high-resolution multistage mass spectral analysis. For quantification, houttuynin and internal standard (IS, benzophenone) in plasma were firstly converted to their DNPH derivatives without sample purification, then extracted from human plasma with n-hexane and detected by liquid chromatography tandem mass spectrometry performed in selected reaction monitoring (SRM) mode. This method allowed for a lower limit of quantification (LLOQ) of 1.0 ng/ml using 100-microl plasma. The validation results showed high accuracy (%bias < 2.1) and precision (%CV < 7.2) at broad linear dynamic range (1.0-5000 ng/ml). The simple and quantitative derivatization coupled with tandem mass spectrometric analysis facilitates a sensitive and robust method for the determination of plasma houttuynin in pharmacokinetic studies.  相似文献   

13.
甘草化学成分的高效液相色谱-串联质谱分析   总被引:21,自引:0,他引:21  
采用高效液相色谱-质谱联用方法分析了甘草(Glycyrrhiza uralensis)中的化学成分。通过高效液相色谱可将三萜、黄酮及香豆素等50余种化学成分较好的分离。根据紫外光谱可大致判断其化合物类型,由电喷雾质谱得到各成分的分子量,再由串联质谱获得进一步的结构信息,进而推测出其中22个主要成分的可能结构。它们分别是:葡糖基甘草甙、异光果甘草甙、夏拂托甙、甘草素-4′-芹糖甙,甘草甙,6′-乙酰甘草甙,异佛来心甙,异甘草素葡萄糖芹菜甙,甘草糖甙A,甘草糖甙B,甘草素,3.0-[β-D-葡萄糖醛酸甲酯-(1→2)-β-D-葡萄糖醛酸]-24-羟基-甘草内酯,甘草皂甙E2,异甘草素,甘草醇,甘草酸,甘草香豆素,甘草双氢异黄酮,甘草异黄酮甲,乌拉尔甘草皂甙乙,新甘草酚和甘草皂甙B2。  相似文献   

14.
The development and validation of an assay for the determination of paclitaxel in human plasma, human brain tumor tissue, mouse plasma and mouse brain tumor tissue is described. Paclitaxel was extracted from the matrices using liquid-liquid extraction with tert-butyl methyl ether, followed by chromatographic analysis using an alkaline eluent. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicate that calibration standards in human plasma can be used to quantify paclitaxel in all tested matrices. In human samples, the validated range for paclitaxel was from 0.25-1000 ng ml(-1) using 200 microl plasma aliquots and from 5 to 5000 ng g(-1) using 50 microl tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma). In mice, the ranges were 1-1000 ng ml(-1) and 5-5000 ng g(-1) using 50 microl of mouse plasma and 50 microl of tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma), respectively. The method can be applied to studies generating only small sample volumes (e.g. mouse plasma and tumor tissue), but also to studies in human plasma requiring a lower limit of quantitation. The assay was applied successfully to several studies with both human and mouse samples.  相似文献   

15.
The utility of liquid chromatography combined with time-of-flight mass spectrometry (LC/TOFMS) was demonstrated for studies on chiral unsaturated epoxy compounds, sex pheromones produced mainly by female moths in the family Geometridae. By electrospray ionization (ESI), each synthetic epoxyalkadiene derived from (Z,Z,Z)-3,6,9-triene with a C(18)-C(23) straight chain showed three ion series, [M + NH(4)](+), [M + H](+) and [M - OH](+), with high resolution and good sensitivity, indicating its molecular formula. In addition to these, characteristic fragment ions at m/z M - 57 and M - 71 for the 3,4-epoxides and at m/z M - 123 and 123 for the 9,10-epoxides were detected, whereas the 6,7-epoxides did not produce fragment ions that reflected their structures. Monitoring these diagnostic ions during the LC/MS analysis of a gland extract, the natural sex pheromone of the mulberry looper was confirmed to be (Z,Z)-cis-9,10-epoxy-3,6-octadecadiene, which was separable from the other positional isomers on an ODS column. Furthermore, (Z,Z)-cis-3,4-epoxy-6,9-nonadecadiene secreted by the Japanese giant looper was analyzed with a chiral column, and the stereochemistry was determined directly.  相似文献   

16.
Oligo(3‐OH butyrate)‐β‐cyclodextrin esters (PHB‐CD) were obtained through ring opening of β‐butyrolactone (β‐BL) in the presence of β‐cyclodextrin (CD) and (‐)‐sparteine (SP) as nucleophilic activator. The resulted reaction mixture was first separated in two fractions and then investigated through a deep mass spectrometry (MS) study performed on a liquid chromatography‐electrospray ionization‐quadrupole time of flight (LC‐ESI‐QTOF) instrument. LC MS and tandem MS structural assignment of the reaction products was completed by NMR. The performed analysis revealed that poly(3‐OH butyrate) homopolymers (PHB) are formed together with the PHB‐CD products. Secondary reactions resulting in the formation of crotonates were also proved to occur. A comparison between MS and NMR results demonstrated that more than one PHB oligomer is attached to the CD in the PHB‐CD product. The tandem MS fragmentation studies validated the proposed structure of CD derivatives. © 2010 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem, 2010  相似文献   

17.
Liquid chromatography coupled with ionspray mass spectrometry in the tandem mode (LC/MS/MS) with negative ion detection was used for the identification of a variety of phenolic compounds in a cocoa sample. Gradient elution with water and acetonitrile, both containing 0.1% HCOOH, was used. Standard solutions of 31 phenolic compounds, including benzoic and cinnamic acids and flavonoid compounds, were studied in the negative ion mode using MS/MS product ion scans. At low collisional activation, the deprotonated molecule [M - H](-) was observed for all the compounds studied. For cinnamic and benzoic acids, losses of CO(2) or formation of [M - CH(3)](-*) in the case of methoxylated compounds were observed. However, for flavonol and flavone glycosides, the spectra present both the deprotonated molecule [M - H](-) of the glycoside and the ion corresponding to the deprotonated aglycone [A - H](-). The latter ion is formed by loss of the rhamnose, glucose, galactose or arabinose residue from the glycosides. Different fragmentation patterns were observed in MS/MS experiments for flavone-C-glycosides which showed fragmentation in the sugar part. Fragmentation of aglycones provided characteristic ions for each family of flavonoids. The optimum LC/MS/MS conditions were applied to the characterization of a cocoa sample that had been subjected to an extraction/clean-up procedure which involved chromatography on Sephadex LH20 and thin-layer chromatographic monitoring. In addition to compounds described in the literature, such as epicatechin and catechin, quercetin, isoquercitrin (quercetin-3-O-glucoside) and quercetin-3-O-arabinose, other compounds were identified for the first time in cocoa samples, such as hyperoside (quercetin-3-O-galactoside), naringenin, luteolin, apigenin and some O-glucosides and C-glucosides of these compounds.  相似文献   

18.
基于手性固定相/超高效液相色谱-串联质谱技术建立了同时拆分2种叶菜类蔬菜(菜心、油麦菜)中5种典型手性农药(多效唑、腈菌唑、甲霜灵、三唑酮和唑菌酮)对映体的分析方法。样品用乙腈提取,N-丙基乙二胺(PSA)粉和石墨化碳黑(GCB)粉净化,经手性色谱柱CHIRALCELOD-RH拆分后,超高效液相色谱-串联质谱(UPLC-MS/MS)检测。结果表明,5种手性农药在0.005~1.0mg·L-1范围内均呈良好线性关系;在0.01、0.1、0.5mg·kg-1加标水平下的平均回收率为68.8%~104%,相对标准偏差(n=6)为1.0%~13.7%。该方法准确、简单、可靠,可以满足叶菜类蔬菜中多种手性农药残留的检测要求,并为这5种手性农药对映体在蔬菜中的残留及消解规律研究提供技术支持。  相似文献   

19.
A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 μm, 50 mm × 2.1 mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0–103.4%, with the RSD < 15%. The calibration curves for alkylphenols were linear within the range of 0.01–0.4 μg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 μg/kg.  相似文献   

20.
Qualitative and quantitative analyses of phenolic compounds are of interest for both medicinal and food plants. In the present work, the phenolic fraction from Yucca schidigera, a plant bearing the GRAS (Generally Recognized as Safe) label approved by the US Food and Drug Administration, was studied. Crude extracts of Y. schidigera bark were investigated by liquid chromatography/UV spectrophotometry with diode-array detection, liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS), in order to develop and optimize simple and rapid techniques to determine both stilbenes and yuccaols for the purposes of quality control of collected material. With optimal LC and MS conditions, stilbenes and yuccaols were quantified with all the proposed methods and the results were compared. Sensitivity was evaluated and the results indicated that MS/MS detection in the multiple reaction monitoring mode is easily applicable to this plant and allows the rapid and direct identification and quantification of these peculiar compounds in crude plant extracts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号