首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, a simple and accurate sample preparation method based on dispersive solid‐phase extraction and dispersive liquid‐liquid microextraction has been developed for the determination of seven novel succinate dehydrogenase inhibitor fungicides (isopyrazam, fluopyram, pydiflumetofen, boscalid, penthiopyrad, fluxapyroxad, and thifluzamide) in watermelon. The watermelon samples were extracted with acetonitrile, cleaned up by dispersive solid‐phase extraction procedure using primary secondary amine, extracted and concentrated by the dispersive liquid‐liquid microextraction procedure with 1,1,2,2‐tetrachloroethane, and then analyzed by ultra high performance liquid chromatography with tandem mass spectrometry. The main experimental factors affecting the performance of dispersive solid‐phase extraction and dispersive liquid‐liquid microextraction procedure on extraction efficiency were investigated. The proposed method had a good linearity in the range of 0.1–100 µg/kg with correlation coefficients (r) of 0.9979–0.9999. The limit of quantification of seven fungicides was 0.1 µg/kg in the method. The fortified recoveries of seven succinate dehydrogenase inhibitor fungicides at three levels ranged from 72.0 to 111.6% with relative standard deviations of 3.4–14.1% (n = 5). The proposed method was successfully used for the rapid determination of seven succinate dehydrogenase inhibitor fungicides in watermelon.  相似文献   

2.
A high‐throughput method based on ultrasonic‐assisted extraction, 96‐well plate thin‐film microextraction was established to determinate 18 antibiotics in animal feed. In this method, the extraction was implemented by ultrasonic‐assisted extraction for 30 min with disodium ethylenediaminetetraacetic acid‐McIlvaine buffer (pH 5) containing 6% sodium chloride w/v, purified by thin‐film microextraction and combined with 96‐well plate system to improve the efficiency. Optimization of thin‐film microextraction conditions was performed by methods of single factor and response surface, and finalized as: condition time: 20 min; adsorption time: 55 min; washing time: 5 s with water; desorption time: 30 min with acetonitrile/water (8:2, v/v) containing 0.1% formic acid v/v. Evaluation of different extractive phases showed that polystyrene‐divinylbenzene‐polyacrylonitrile was the optimum coating. The analysis was performed by ultra‐high performance liquid chromatography with tandem mass spectrometry. Recovery, inter‐ and intraday precision, linearity, limit of detection, and quantitation were evaluated. The average recoveries of 18 antibiotics were 66.6–93.5% at three spiked levels, intraday precision was 1–8.4%, and interday precision was 3.0–16.4%. The linearity was good for r> 0.99. Limits of detection and quantification were found in the range of 1–14 and 4–48 µg/kg, respectively.  相似文献   

3.
A novel effervescence‐assisted dispersive liquid–liquid microextraction method has been developed for the determination of four fungicides in apple juice samples. In this method, a solid effervescent agent is added into samples to assist the dispersion of extraction solvent. The effervescent agent is environmentally friendly and only produces an increase in the ionic strength and a negligible variation in the pH value of the aqueous sample, which does not interfere with the extraction of the analytes. The parameters affecting the extraction efficiency were investigated including the composition of effervescent agent, effervescent agent amount, formulation of effervescent agent, adding mode of effervescent agent, type and volume of extraction solvent, and pH. Under optimized conditions, the method showed a good linearity within the range of 0.05–2 mg/L for pyrimethanil, fludioxonil, and cyprodinil, and 0.1–4 mg/L for kresoxim‐methyl, with the correlation coefficients >0.998. The limits of detection for the method ranged between 0.005 and 0.01 mg/L. The recoveries of the target fungicides in apple juice samples were in the range of 72.4–110.8% with the relative standard deviations ranging from 1.2 to 6.8%.  相似文献   

4.
A zirconium terephthalate metal‐organic framework‐incorporated poly(N‐vinylcarbazole‐co‐divinylbenzene) monolith was fabricated in a capillary by a thermal polymerization method. The optimized monolith had a homogeneous structure, good permeability, and stability. The monolith could be used for the effective enrichment of fungicides through π‐π interactions, electrostatic forces, and hydrogen bonds. The potential factors that affect the extraction efficiency, including ionic strength, solution pH, sample volume, and eluent volume, were investigated in detail. The monolith‐based in‐tube solid‐phase microextraction coupled with ultra‐high‐performance liquid chromatography and high‐resolution Orbitrap mass spectrometry was performed for the analysis of five fungicides (pyrimethanil, tebuconazole, hexaconazole, diniconazole, and flutriafol) in environmental samples. Under the optimized conditions, the linear ranges were 0.005–5 ng/mL for pyrimethanil, 0.01–5 ng/mL for flutriafol, and 0.05–5 ng/mL for other fungicides, respectively, with coefficients of determination ≥0.9911. The limits of detection were 1.34–14.8 ng/L. The columns showed good repeatability (relative standard deviations ≤9.3%, n = 5) and desirable column‐to‐column reproducibility (relative standard deviations 5.3–9.4%, n = 5). The proposed method was successfully applied for the simultaneous detection of five fungicides in water and soil samples, with recoveries of 90.4–97.5 and 84.0–95.3%, respectively.  相似文献   

5.
A novel design of hollow‐fiber liquid‐phase microextraction containing multiwalled carbon nanotubes as a solid sorbent, which is immobilized in the pore and lumen of hollow fiber by the sol–gel technique, was developed for the pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples. The proposed method utilized both solid‐ and liquid‐phase microextraction media. Parameters that affect the extraction of polycyclic aromatic hydrocarbons were optimized in two successive steps as follows. Firstly, a methodology based on a quarter factorial design was used to choose the significant variables. Then, these significant factors were optimized utilizing central composite design. Under the optimized condition (extraction time = 25 min, amount of multiwalled carbon nanotubes = 78 mg, sample volume = 8 mL, and desorption time = 5 min), the calibration curves showed high linearity (R 2 = 0.99) in the range of 0.01–500 ng/mL and the limits of detection were in the range of 0.007–1.47 ng/mL. The obtained extraction recoveries for 10 ng/mL of polycyclic aromatic hydrocarbons standard solution were in the range of 85–92%. Replicating the experiment under these conditions five times gave relative standard deviations lower than 6%. Finally, the method was successfully applied for pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples.  相似文献   

6.
A new, simple, and rapid syringe‐to‐syringe dispersive liquid‐phase microextraction with solidified floating organic drop was used for the separation and preconcentration of ochratoxin A from grain and juice samples before its quantification using high‐performance liquid chromatography and fluorescence detection. Factors influencing the microextraction efficiency of ochratoxin A, such as sample solution pH, type and volume of organic extractant, salt concentration, number of injections, and volume of the sample, were studied and optimized. Under the optimum properties, the calibration graph showed linearity in the range of 65.0–700.0 ng/L (coefficient of determination = 0.9991). The limit of detection was 20.0 ng/L. The inter‐day and intra‐day relative standard deviations were in the range of 5.0–8.5%. This method was successfully applied for the quantification of ochratoxin A in grain and juice samples.  相似文献   

7.
A novel manual‐shaking‐ and ultrasound‐assisted surfactant‐enhanced emulsification microextraction method was developed for the determination of three fungicides in juice samples. In this method, the ionic liquid, 1‐ethyl‐3‐methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, instead of a volatile organic solvent was used as the extraction solvent. The surfactant, NP‐10, was used as an emulsifier to enhance the dispersion of the water‐immiscible ionic liquid into an aqueous phase, which accelerated the mass transfer of the analytes. Organic dispersive solvent typically required in common dispersive liquid–liquid microextraction methods was not necessary. In addition, manual shaking for 15 s before ultrasound to preliminarily mix the extraction solvent and the aqueous sample could greatly shorten the time for dispersing the ionic liquid into aqueous solution by ultrasound irradiation. Several experimental parameters affecting the extraction efficiency, including type and volume of extraction solvent, type and concentration of surfactant, extraction time, and pH, were optimized. Under the optimized conditions, good linearity with the correlation coefficients (γ) higher than 0.9986 and high sensitivity with the limit of detection ranging from 0.4 to 1.6 μg/L were obtained. The average recoveries ranged from 61.4 to 86.0% for spiked juice, with relative standard deviations from 1.8 to 9.7%. The proposed method was demonstrated to be a simple, fast, and efficient method for the analysis of the target fungicides in juice samples.  相似文献   

8.
A simple, rapid, sensitive, and environmentally friendly method, based on modified dispersive liquid–liquid microextraction coupled with high‐performance liquid chromatography was developed for the simultaneous determination of five biogenic amines in fermented food samples. Biogenic amines were derivatized with 9‐fluorenylmethyl chloroformate, extracted by vortex‐assisted surfactant‐enhanced emulsification liquid–liquid microextraction, and then analyzed by high‐performance liquid chromatography. Five biogenic amine compounds were separated within 30 min using a C18 column and gradient elution with acetonitrile and 1% acetic acid. Factors influencing the derivatization and extraction efficiency such as type and volume of extraction solvent, type, and concentration of surfactant, pH, salt addition, and vortex time were optimized. Under the optimum conditions, the method provided the enrichment factors in the range of 161–553. Good linearity was obtained from 0.002–0.5 mg/L for cadaverine and tyramine, 0.003–1 mg/L for tryptamine and histamine, and 0.005–1 mg/L for spermidine with coefficient of determination (R2) > 0.992. The limits of detection ranged from 0.0010 to 0.0026 mg/L. The proposed method was successfully applied to analysis of biogenic amines in fermented foods such as fermented fish (plaa‐som), wine and beer where good recoveries were obtained in the range of 83.2–112.5%  相似文献   

9.
A vortex‐assisted liquid–liquid microextraction method was developed for the chromatographic determination of strontium in aqueous samples. In the method, strontium was complexed with 4′,4″(5″)‐di‐(tert‐butylcyclohexano)‐18‐crown‐6 in the presence of tetraphenylborate as the counter anion, which increased the hydrophobicity of the ion‐association complex, resulting in its improved extraction into 1‐octanol. Strontium from the organic phase was stripped with nitric acid back to aqueous solution and determined by ion chromatography. The optimum microextraction conditions were as follows: 2.0 mL aqueous samples with 3 mM tetraphenylborate; 150 μL of 1‐octanol as the extractant phase with 10 mM DtBuCH18C6; vortex extraction time for 10 s; centrifugation at 6000 rpm for 4 min; stripping by 0.1 M nitric acid. Under the optimum conditions, the detection limit for strontium was 0.005 mg/L. The calibration curves showed good linearity over the range between 0.01 and 2.5 mg/L. Intra‐ and interday precisions of the present method were satisfactory with relative standard deviations of 1.7 and 2.1%, respectively.  相似文献   

10.
To enrich carbamate pesticides from complex matrices, an adsorbent based on poly (vinylboronic anhydride pyridine complex‐co‐ethylenedimethacrylate) monolith was fabricated and utilized as the extraction phase of multiple monolithic fiber solid‐phase microextraction. Due to the abundant boron atoms in the monolith, the B–N coordination interaction between adsorbent and analytes play a key role in the efficient extraction of analytes. Under the optimized conditions, the monolithic fibers were combined with high‐performance liquid chromatography for the quantify trace levels of carbamate pesticides in environmental water and orange juice samples. For water sample, the limit of detection and limit of quantification were in the range of 0.017–0.29 and 0.057–0.96 μg/L, respectively. The related values in orange juice samples were 0.038–0.39 and 0.12–1.36 μg/kg, respectively. Besides, the proposed method also exhibits wide linearity, satisfactory coefficients of determination, and good precision. The introduced approach was successfully applied to determine trace target analytes in real‐life samples. The spiked recoveries with different fortified concentrations were in the range of 80.4–117% for water samples and 83.7–119% for fruit juice samples. The relative standard deviations were below 10%. The results evidence that the suggested method was convenient, reliable, and eco‐friendly for the monitoring of trace levels of carbamate pesticides in complex samples such as waters and juices.  相似文献   

11.
We report the electrochemical fabrication of a poly(2,2‐bithiophene‐co‐3‐methylthiophene)‐graphene composite coating and its application in the headspace solid‐phase microextraction and gas chromatography determination of benzenes (i.e., bromobenzene, 4‐bromotoluene, 2‐nitrotoluene, 3‐nitrotoluene and 1,2,4‐trichlorobenzene). The coating was uniform and showed cauliflower‐like microstructure. It had high thermal stability (up to 375°C) and could be used for at least 180 times of solid‐phase microextraction without a decrease in extraction performance. Furthermore, it presented high extraction capacity for the benzenes due to the hydrophobic effect and π–π interaction between the analytes and the coating. Under optimized extraction conditions, good linearity (correlation coefficients higher than 0.9946), wide linear range (0.01–50 μg/L), and low limits of detection (5.25–12.5 ng/L) were achieved for these analytes. The relative standard deviation was lower than 5.7% for five successive measurements with one fiber, and the relative standard deviation for fiber‐to‐fiber was 4.9–6.8% (n = 5). The solid‐phase microextraction and gas chromatography method was successfully applied for the determination of three real samples, and the recoveries for standards added were 89.6–106% for nail polish, 85.8–110% for hair dye, and 90–106.2% for correction fluid, respectively.  相似文献   

12.
In this study, ionic liquid (IL) supported magnetic dispersive solid‐phase microextraction was developed and a systematic investigation was conducted on imidazolium ILs for their extraction performance. This nano‐based pretreatment procedure was then applied for the determination of acaricides in fruit juice samples for the first time. A feature of this technique is that the commonly laborious chemical modification of magnetic nanoparticles (MNPs) was skillfully circumvented. Because of the combination of ILs, dispersive liquid–liquid microextraction, and dispersive MNP solid‐phase microextraction, the extraction efficiency can be significantly improved using commercial MNPs. Parameters of the extraction method were investigated by one‐factor‐at‐a‐time approach. The optimal experimental conditions were as follows: emulsification for 2 min by sonication with the addition of 50 μL [C6MIM][NTf2] in the dispersive liquid–liquid microextraction step and vortexing for 90 s after adding 40 mg spherical barium ferrite nanoparticles (20 nm). The desorption time was 2 min. Good linearity (0.5–500 ng/mL) and detection limits within the range of 0.05–0.53 ng/mL were achieved. The application of the proposed method was demonstrated by the analysis of real fruit juice samples, in which recoveries between 85.1 and 99.6% were obtained.  相似文献   

13.
Vortex‐assisted dispersive liquid–liquid microextraction using methyl benzoate as an alternative extraction solvent for extracting and preconcentrating three benzimidazole fungicides (i.e., carbendazim, thiabendazole, and fluberidazole) in environmental water samples before high‐performance liquid chromatographic analysis has been developed. The selected microextraction conditions were 250 μL of methyl benzoate containing 300 μL of ethanol, 1.0% w/v sodium acetate, and vortex agitation speed of 2100 rpm for 30 s. Under optimum conditions, preconcentration factors were 14.5–39.0 for the target fungicides. Limits of detection were obtained in the range of 0.01–0.05 μg/L. The proposed method was then applied to surface water samples and the recovery evaluations at three spiked concentration levels of 5, 30, and 50 μg/L were obtained in the range of 77.4–110.9% with the relative standard deviation <7.4%. The present method was simple, rapid, low cost, sensitive, environmentally friendly, and suitable for the trace analysis of the studied fungicides in environmental water samples.  相似文献   

14.
Switchable‐hydrophilicity solvent liquid‐liquid microextraction and dispersive liquid‐liquid microextraction were compared for the extraction of piperine from Piper nigrum L. prior to its analysis by using high‐performance liquid chromatography with UV detection. Under optimum conditions, limits of detection and quantitation were found as 0.2–0.6 and 0.7–2.0 μg/mg with the two methods, respectively. Calibration graphs showed good linearity with coefficients of determination (R2) higher than 0.9962 and percentage relative standard deviations lower than 6.8%. Both methods were efficiently used for the extraction of piperine from black and white pepper samples from different origins and percentage relative recoveries ranged between 90.0 and 106.0%. The results showed that switchable‐hydrophilicity solvent liquid‐liquid microextraction is a better alternative to dispersive liquid‐liquid microextraction for the routine analysis of piperine in food samples. A novel scaled‐up dispersive liquid‐liquid microextraction method was also proposed for the isolation of piperine providing a yield of 102.9 ± 4.9% and purity higher than 98.0% as revealed by NMR spectroscopy.  相似文献   

15.
A novel microextraction method, termed microwave‐assisted ionic liquid/ionic liquid dispersive liquid–liquid microextraction, has been developed for the rapid enrichment and analysis of triazine herbicides in fruit juice samples by high‐performance liquid chromatography. Instead of using hazardous organic solvents, two kinds of ionic liquids, a hydrophobic ionic liquid (1‐hexyl‐3‐methylimidazolium hexafluorophosphate) and a hydrophilic ionic liquid (1‐butyl‐3‐methylimidazolium tetrafluoroborate), were used as the extraction solvent and dispersion agent, respectively, in this method. The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of 1‐hexyl‐3‐methylimidazolium hexafluorophosphate dispersed entirely into sample solution with the help of 1‐butyl‐3‐methylimidazolium tetrafluoroborate. In addition, an ion‐pairing agent (NH4PF6) was introduced to improve recoveries of the ionic liquid phase. Several experimental parameters that might affect the extraction efficiency were investigated. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 5.00–250.00 μg/L, with the correlation coefficients of 0.9982–0.9997. The practical application of this effective and green method is demonstrated by the successful analysis of triazine herbicides in four juice samples, with satisfactory recoveries (76.7–105.7%) and relative standard deviations (lower than 6.6%). In general, this method is fast, effective, and robust to determine triazine herbicides in juice samples.  相似文献   

16.
《Electrophoresis》2017,38(3-4):494-500
An easy‐to‐do paper‐based solid‐phase microextraction (p‐SPME) was developed for determination of 8‐hydroxy‐2’‐deoxyguanosine (8‐OHdG) in urine sample by CE‐LIF. Small piece of filter paper was used as a solid phase to extract 8‐OHdG from urine sample. Its primary mechanism is based on the hydrogen‐bonding interaction between 8‐OHdG and cellulose molecules. The effects of the pH of the sample solution, extraction time, and temperature on the peak area of the analyte were investigated in order to obtain the optimal p‐SPME conditions. Comparing with the untreated sample, the p‐SPME can significantly reduce the interference to the separation of 8‐OHdG by CE‐LIF. Meanwhile, the p‐SPEM can provide more than three times concentrated effect. The developed method was evaluated according to an FDA guideline for biological analysis. The precisions (RSD%, n = 5) of the peak area and migration time of the analyte at three different concentrations were within 3.02–5.82% and 0.92–1.58%, respectively. The limit of identification of the method is about 5 nM according to the significant difference between two sets of the samples with and without spiking the standard (Student's t ‐test, p < 0.05). Good linearity was obtained in the range of 10–1000 nM (R 2>0.99) based on the standard addition. The recoveries at three different concentrations were within 99.8–103.5%. The results of the real sample analysis are consistent with those reported in our previous paper (Electrophoresis 2014, 35, 1873–1879).  相似文献   

17.
In this study, a microextraction method termed as ultrasound‐assisted emulsification–microextraction (USAEME) has been developed for the extraction of organophosphorus pesticides (OPPs) in water and orange juice samples. In the USAEME method, aliquots of 50 μL chlorobenzene used as extraction solvent was added to 10 mL water sample in a conical glass centrifugal tube. Factors influencing the USAEME extraction efficiency such as sonication time, extraction solvent, extraction volume and salt addition were evaluated. Under the optimum conditions, enrichment factors ranged from 241 to 311, LOD varied from 5.3 to 10.0 ng/L and linearity with a coefficient of estimation (r2) varied from 0.9991 to 0.9998 in the concentration level range of 0.05–2.5 μg/L for the extraction of OPPs in water samples. Finally, the proposed USAEME method was used for the extraction of OPPs from water and orange juice. The recoveries were in the range of 80.0–110.0%, and the repeatability of the method expressed as RSD (n=3) varied between 1.6 and 13%. The USAEME method has the advantage of being easy to operate, low consumption of organic solvent and high extraction efficiency.  相似文献   

18.
Stainless‐steel wires coated with mesoporous titanium oxide were placed into a polyether ether ketone tube for in‐tube solid‐phase microextraction, and the coating sorbent was characterized by X‐ray diffraction and scanning electron microscopy. It was combined with high‐performance liquid chromatography to build an online system. Using eight polycyclic aromatic hydrocarbons as the analytes, some conditions including sample flow rate, sample volume, organic solvent content, and desorption time were investigated. Under optimum conditions, an online analysis method was established and provided good linearity (0.03–30 μg/L), low detection limits (0.01–0.10 μg/L), and high enrichment factors (77.6–678). The method was applied to determine target analytes in river water and water sample of coal ash, and the recoveries are in the range of 80.6–106.6 and 80.9–103.5%, respectively. Compared with estrogens and plasticizers, extraction coating shows better extraction efficiency for polycyclic aromatic hydrocarbons.  相似文献   

19.
A new analytical method for the simultaneous determination of trace levels of seven prohibited N‐nitrosamines (N‐nitrosodimethylamine, N‐nitrosoethylmethylamine, N‐nitrosopyrrolidine, N‐nitrosodiethylamine, N‐nitrosopiperidine, N‐nitrosomorpholine, and N‐nitrosodiethanolamine) in cosmetic products has been developed. The method is based on vortex‐assisted reversed‐phase dispersive liquid–liquid microextraction, which allows the extraction of highly polar compounds, followed by liquid chromatography with mass spectrometry. The variables involved in the extraction process were studied to obtain the highest enrichment factor. Under the selected conditions, 75 μL of water as extraction solvent was added to 5 mL of n‐hexane sample solution and assisted by vortex mixing during 30 s to form the cloudy solution. The method was successfully validated showing good linearity (0.5–50 ng/mL), enrichment factors up to 65 depending on the target compound, limits of detection values of 1.8–50 ng/g, and good repeatability (RSD < 9.8%). Finally, the proposed method was applied to different cosmetic samples. Quantitative relative recovery values (80–113%) were obtained, thus showing that matrix effects were negligible. The achieved analytical features of the proposed method, besides of its simplicity and affordability, make it useful to perform the quality control of cosmetic products to ensure the safety of consumers.  相似文献   

20.
Offline dispersive liquid‐liquid microextraction combined with online pressure‐assisted electrokinetic injection was developed to simultaneously enrich seven phenolic compounds in water samples, followed by determination using capillary electrophoresis, namely phenol, 4‐chlorophenol, pentachlorophenol, 2,4,6‐trichlorophenol, 2,4‐dichlorophenol, 2‐chlorophenol, and 2,6‐dichlorophenol. Several parameters affecting separation performance of capillary electrophoresis and the enrichment efficiency of pressure‐assisted electrokinetic injection and dispersive liquid‐liquid microextraction were systematically investigated. Under the optimal conditions, seven phenolic compounds were completely separated within 14 min and good enrichment factors were obtained of 61, 236, 3705, 3288, 920, 86, and 1807 for phenol, 4‐chlorophenol, pentachlorophenol, 2,4,6‐trichlorophenol, 2,4‐dichlorophenol, 2‐chlorophenol, and 2,6‐dichlorophenol, respectively. Good linearity was attained in the range of 0.1–200 μg/L for 2,4‐dichlorophenol, 0.5–200 μg/L for 4‐chlorophenol, pentachlorophenol, 2,4,6‐trichlorophenol, 2‐chlorophenol, and 2,6‐dichlorophenol, as well as 1–200 μg/L for phenol, with correlation coefficients (r) over 0.9905. The limits of detection and quantification ranging from 0.03–0.28 and 0.07–0.94 μg/L were attained. This two step enrichment method was potentially applicable for the rapid and simultaneous determination of phenolic compounds in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号