首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Three barbiturate drugs, barbital, phenobarbital, and secobarbital were separated and analyzed by electrokinetic supercharging. The influence of different parameters on electrokinetic supercharging performance was evaluated using both univariated and multivariated optimization processes. The parameters studied were sample pH, concentration, and length of the leading and terminating electrolytes, electrokinetic injection of the sample and composition and hydrodynamic injection of the solvent plug. The leading electrolyte (50 mM NaCl) was hydrodynamically injected (50 mbar × 120 s) prior to the sample that was adjusted to pH 9.6 and electrokinetically injected at ?8.5 kV for 300 s. The terminating electrolyte (100 mM of 2‐(cyclohexylamino) ethanesulphonic acid) was then hydrodynamically injected (50 mbar × 140 s). The results showed that this strategy enhanced detection sensitivity around 1050‐fold compared with normal hydrodynamic injection, providing detection limits ranging between 1.5 and 2.1 ng/mL for standard samples with good repeatability in terms of peak area (values of relative standard deviation, %RSD < 3). The applicability of the optimized method was demonstrated by the analysis of human urine samples spiked with the studied compounds at different concentration levels and further liquid–liquid extraction step. The estimated detection limits obtained in the urine samples extract ranged between 8 and 15 ng/mL.  相似文献   

2.
This work presents a strategy based on the in‐line coupling of SPE and CE for the chiral determination of cathinones (R,S‐mephedrone, R,S‐4‐methylephedrine, and R,S‐ methylenedioxypyrovalerone) in urine samples, using a sample pretreatment based on liquid‐liquid extraction. The chiral separation of the compounds is achieved by adding a mixture of 8 mM 2‐hydroxypropil β‐CD and 5 mM β‐CD to the BGE, which consists of 70 mM of monosodium phosphate aqueous solution at pH 2.5. Oasis HLB was the selected sorbent for the in‐line SPE device, and to reduce analysis time and LODs, several parameters affecting the in‐line SPE system were evaluated, such as pressure and time of sample injection and dimensions of the SPE device. The highest preconcentration factors were achieved by using 3 bar of injection pressure for 20 min with an in‐line SPE device of 2 mm length and 150 µm of i.d. The developed method was applied to determine the presence of the compounds in spiked urine samples. The LODs obtained were between 3 and 8 ng/mL, and these levels were below the usual concentrations at which these drugs are present in urine from cathinone abusers. Thus, the optimized method has the potential to be applied for toxicological and forensic purposes.  相似文献   

3.
《Electrophoresis》2018,39(16):2099-2106
A method consisting of cation‐selective exhaustive injection and sweeping (CSEI‐sweeping) as online preconcentration followed by a cyclodextrin modified electrokinetic chromatography (CDEKC) enantioseparation has been developed for the simultaneous determination of two brompheniramine enantiomers in rat plasma. In this method, analytes were electrokinetically injected at a voltage of 8 kV for 80 s in a fused‐silica capillary. Prior to the injection, the capillary was rinsed with 50 mM phosphate buffer of pH 3.5, followed by a plug of a higher conductivity buffer (150 mM phosphate pH 3.5, 20 psi, 6 min) and a plug of water (0.5 psi, 5 s). Separation was carried out applying –20 kV in 50 mM phosphate buffer, pH 3.5, containing 10% v/v ACN and 30 mg/mL sulfated‐β‐cyclodextrin (S‐β‐CD). Analytical signals were monitored at 210 nm. The detection sensitivity of brompheniramine enantiomers was enhanced by about 2400‐fold compared to the normal injection mode (hydrodynamic injection for 3 s at 0.5 psi, with a BGE of 50 mM phosphate buffer containing 20 mg/mL S‐β‐CD at pH 3.5), and LLOQ of two enantiomers were both 0.0100 μg/mL. In addition, this method had fairly good repeatability and showed promising capabilities in the application of stereoselective pharmacokinetic investigations for brompheniramine enantiomers in rat.  相似文献   

4.
A simple method that consumes low organic solvent is proposed for the analysis of phthalic acid esters in Chinese white spirit using dispersive liquid–liquid microextraction coupled with sweeping‐micellar electrokinetic chromatography. Tetrachloromethane and white‐spirit‐containing ethanol were used as the extraction and dispersing solvents, respectively. The electrophoresis separation buffer was composed of 5 mM β‐cyclodextrin, 50 mM sodium dodecyl sulfate and 25 mM borate buffer (pH 9.2) with 9% acetonitrile, enabling the baseline resolution of the analytes within 13 min. Under the optimum conditions, satisfactory linearities (5–1000 ng/mL, r ≥ 0.9909), good reproducibility (RSD ≤ 6.7% for peak area, and RSD ≤ 2.8% for migration time), low detection limits (0.4–0.8 ng/mL) and acceptable recovery rates (89.6–105.7%) were obtained. The proposed method was successfully applied to 22 Chinese white spirits, and the content of dibutyl phthalate in 55% of the samples exceeded the Specific Migration Limit of 0.3 mg/kg established by the domestic and international regulations.  相似文献   

5.
Enantiomers of clenbuterol, salbutamol and tulobuterol were directly separated and quantitated from a spiked sample by capillary electrophoresis (CE) using sulfaited beta-cyclodextrin (SCD) as chiral selector and phosphate as running buffer. The SCD and buffer concentration, pH and field strength were the parameters studied to optimize the separation. Optimal separation was obtained using 50 mM of phosphate monobasic at pH = 2.24, 0.25% (w/w) of sulfated cyclodextrin and a field strength of 10 kV, with 20 min total time analysis. Comparison between two different injection modes (hydrodynamic and electrokinetic) was made. In the hydrodynamic mode, repeatability (expressed as relative standard deviation, RSD) was less than 1.2% for migration times for all the analyte peaks and less than 2% for peak area percentages. With respect to reproducibility, RSD was less than 3.8% for migration time and less than 3% for peak area percentages. Calibration curves were set up for two different sample concentration ranges (1 to 10 microg mL(-1) and 160-800 ng mL(-1), of each of the racemates studied). Although the electrokinetic injection mode for an aqueous sample appeared to suffer from some enantiodiscrimination, calibration curves were linear in the range between 1 and 10 ng mL(-1) with regression coefficients ranging from 0.9996 to 0.9952. As in the case of hydrodynamic injection, the method was tested with a spiked sample.  相似文献   

6.
An enantioselective assay for the determination of methadone and its main metabolite 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine in equine plasma based on capillary electrophoresis with highly sulfated γ‐cyclodextrin as chiral selector and electrokinetic analyte injection is described. The assay is based on liquid/liquid extraction of the analytes at alkaline pH from 0.1 mL plasma followed by electrokinetic sample injection of the analytes from the extract across a buffer plug without chiral selector. Separation occurs cationically at normal polarity in a pH 3 phosphate buffer containing 0.16% (w/v) of highly sulfated γ‐cyclodextrin. The developed assay is precise (intra‐ and interday RSD < 4% and < 7%, respectively), is capable to determine enantiomer levels of methadone and 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine in plasma down to 2.5 ng/mL, and was successfully applied to monitor enantiomer drug and metabolite levels in plasma of a pony that was anesthetized with racemic ketamine and isoflurane and received a bolus of racemic methadone and a bolus followed by constant rate infusion of racemic methadone. The data suggest that the assay is well suited for pharmacokinetic purposes.  相似文献   

7.
A capillary zone electrophoresis (CZE) method with ultraviolet-visible detection has been established and validated for the determination of five phenothiazines: thiazinamium methylsulfate, promazine hydrochloride, chlorpromazine hydrochloride, thioridazine hydrochloride, and promethazine hydrochloride in human urine. Optimum separation was obtained on a 64.5 cm x 75 microm bubble cell capillary using a buffer containing 150 mM tris(hydroxymethyl)aminomethane and 25% acetonitrile at pH 8.2, with temperature and voltage of 25 degrees C and 20 kV, respectively. Naphazoline hydrochloride was used as an internal standard. Field-amplified sample injection (FASI) has been applied to improve the sensitivity of the detection. Considering the influence of parameters affecting the on-line preconcentration (nature of preinjection plug, sample solvent composition, injection times, and injection voltage) and due to the significant interactions among them, in this paper we propose for the first time the application of a multivariate approach to carry out the study. The optimized conditions were as follows: preinjection plug of water for 7 s at 50 mbar, electrokinetic injection for 40 s at 6.2 kV, and 32 microm of H3PO4 in the sample solvent. Also, a solid-phase extraction (SPE) procedure is developed to obtain low detection limits and an adequate selectivity for urine samples. The combination of SPE and FASI-CZE-UV allows adequate linearities and recoveries, low detection limits (from 2 to 5 ng/mL), and satisfactory precisions (3.0-7.2% for an intermediate RSD %).  相似文献   

8.
A new version of dispersive liquid–liquid microextraction, namely, cyclodextrin‐assisted dispersive liquid–liquid microextraction, with subsequent sweeping micellar electrokinetic chromatography has been developed for the preconcentration and sensitive detection of carbamazepine and clobazam. α‐Cyclodextrin and chloroform were used as the dispersive agent and extraction solvent, respectively. After the extraction, carbamazepine and clobazam were analyzed using micellar electrokinetic chromatography with ultraviolet detection. The detection sensitivity was further enhanced using the sweeping technique. Under optimal extraction and stacking conditions, the calibration curves of carbamazepine and clobazam were linear over a concentration range of 2.0–200.0 ng/mL. The method detection limits at a signal‐to‐noise ratio of 3 were 0.6 and 0.5 ng/mL with sensitivity enhancement factors of 3575 and 4675 for carbamazepine and clobazam, respectively. This developed method demonstrated high sensitivity enhancement factors and was successfully applied to the determination of carbamazepine and clobazam in human urine samples. The precision and accuracy for urine samples were less than 4.2 and 6.9%, respectively.  相似文献   

9.
Five non‐steroidal anti‐inflammatory drugs, naproxen, fenoprofen, ketoprofen, diclofenac and piroxicam, were separated and analyzed by electrokinetic supercharging in CZE. Three different setups of the ITP technique were assayed for the separation and preconcentration of these five non‐steroidal anti‐inflammatory drugs. For the setup that gave the best results, we evaluated the influence of different parameters on separation and preconcentration efficiency such as sample pH, concentration of the leading stacker, BGE composition, electrokinetic injection time, composition and hydrodynamic injection of the solvent plug and of the terminating stacker. In the selected setup, the BGE (10 mM Na2B4O7 + 50 mM NaCl in 10% of MeOH aqueous solution) contained the leading electrolyte while the terminating electrolyte, hydrodynamically injected after the sample (50 mbar×12 s), was 50 mM of CHES. Prior to sample injection at (700 s at −2 kV) a short plug of MeOH (50 mbar ×3 s) was hydrodynamically injected. The results show that this strategy enhanced detection sensitivity 2000‐fold compared with normal hydrodynamic injection, providing detection limits of 0.08 μg/L for standard samples with good repeatability (values of relative standard deviation, %RSD < 1.03%). Method validation with river water samples and human plasma demonstrated good linearity, with detection limits of 0.9 and 2 μg/L for river water samples and human plasma samples, respectively (as well as satisfactory precision in terms of repeatability and reproducibility).  相似文献   

10.
A sensitive approach of capillary electrophoresis coupled with field‐amplified sample injection and transient isotachophoresis was developed for the simultaneous determination of two β‐blockers: sotalol and metoprolol. In this dual focusing technique, the samples were prepared via only dissolution in ultrapure water and then injected electrokinetically. Phosphate acted as both the background electrolyte and the leading electrolyte. Its optimized concentration was 80 mM. A total of 25 mM of glycine was used as the terminating electrolyte. Under optimum conditions, good separation of sotalol and metoprolol was achieved within 10 min. In comparison with the conventional method, the sensitivity enhancement factors were up to 1031 and 919 for sotalol and metoprolol, respectively. The proposed method was employed in the determination of sotalol and metoprolol in spiked human urine samples. The limits of detection and limits of quantitation obtained via ultraviolet detection were 5 and 12 ng/mL, respectively, for sotalol, and 10 and 25 ng/mL, respectively, for metoprolol. The intraday repeatability values were lower than 2.7 and 1.7% for peak area and migration time, respectively. The assay is a simple and efficient strategy with potential for application in clinical and biochemical laboratories for monitoring sotalol and metoprolol.  相似文献   

11.
Enantiomers of clenbuterol, salbutamol and tulobuterol were directly separated and quantitated from a spiked sample by capillary electrophoresis (CE) using sulfated β-cyclodextrin (SCD) as chiral selector and phosphate as running buffer. The SCD and buffer concentration, pH and field strength were the parameters studied to optimize the separation. Optimal separation was obtained using 50 mM of phosphate monobasic at pH = 2.24, 0.25% (w/w) of sulfated cyclodextrin and a field strength of 10 kV, with 20 min total time analysis. Comparison between two different injection modes (hydrodynamic and electrokinetic) was made. In the hydrodynamic mode, repeatability (expressed as relative standard deviation, RSD) was less than 1.2% for migration times for all the analyte peaks and less than 2% for peak area percentages. With respect to reproducibility, RSD was less than 3.8% for migration time and less than 3% for peak area percentages. Calibration curves were set up for two different sample concentration ranges (1 to 10 μg mL–1 and 160– 800 ng mL–1, of each of the racemates studied). Although the electrokinetic injection mode for an aqueous sample appeared to suffer from some enantiodiscrimination, calibration curves were linear in the range between 1 and 10 ng mL–1 with regression coefficients ranging from 0.9996 to 0.9952. As in the case of hydrodynamic injection, the method was tested with a spiked sample.  相似文献   

12.
In the past decade, more than 100 different cathinone derivatives slopped over entire Europe due to their enormous popularity. Generally, these novel psychoactive substances are easily available via the internet. This fact leads to various social problems, since cathinones are substances with consciousness‐changing effects and are mainly misused for recreational matters by their consumers. Cathinones possess a chiral center including two enantiomeric forms with potentially different pharmacological behavior. This fact makes analytical method development regarding their chiral separation indispensable. In this study, a chiral capillary zone electrophoresis method for the enantioseparation of 61 cathinone and pyrovalerone derivatives was developed by means of four different β‐cyclodextrin derivatives. As chiral selectors, native β‐cyclodextrin as well as three of its derivatives namely acetyl‐β‐cyclodextrin, 2‐hydroxypropyl‐β‐cyclodextrin, and carboxymethyl‐β‐cyclodextrin were used. The cathinone and pyrovalerone derivatives were either purchased in internet stores or seized by police. As a result, overall 58 of 61 studied substances were partially or baseline separated by at least one of the four chiral selectors using 10 mM of β‐cyclodextrin derivative in a 10 mM sodium phosphate buffer (pH 2.5). Furthermore, the method was found to be suitable for simultaneous enantioseparations, for enantiomeric purity checks and to differentiate between positional isomers. Moreover, an intra‐ and an interday validation was performed successfully for each chiral selector to prove the robustness of the method.  相似文献   

13.
A simple and sensitive analytical method for four isomers of glycopyrrolate in rat plasma was developed using cation‐selective exhaustive injection‐sweeping cyclodextrin‐modified electrokinetic chromatography (CSEI‐Sweeping‐CDEKC) for online enrichment combined with dispersive micro‐solid‐phase extraction pretreatment. The CSEI‐Sweeping‐CDEKC was conducted on an uncoated fused silica capillary (40.2 cm × 75 μm) with an applied voltage of –20 kV. The electrophoretic analysis was carried out in 30 mM phosphate solution at pH 2.0 containing 20 mg/mL sulfated‐β‐cyclodextrin and 5% acetonitrile. Under these optimized conditions, the detection limit for racemic glycopyrrolate was found to be 2.0 ng/mL and this method could increase 495‐fold detection sensitivity compared with the traditional injection method. Additionally, the parameters that affected the extraction efficiency of dispersive micro‐solid‐phase extraction were also examined systematically. The glycopyrrolate isomers in rat plasma samples as low as 0.0625 μg/mL were able to be separated and detected by capillary electrophoresis with the aid of CSEI‐sweeping. The findings of this study show that the dispersive micro‐solid‐phase extraction pretreatment coupled with CSEI‐Sweeping‐CDEKC is a rapid and convenient method for analyzing glycopyrrolate isomers in rat plasma.  相似文献   

14.
A capillary electrophoresis method is proposed to analyze the four most well-known growth hormone–releasing hormone (GHRH) analogs that are misused by athletes. Dimethyl-β-cyclodextrin used as a chiral selector allowed, for the first time, the separation of those basic peptide analogs, including enantiopeptides (sermorelin and CJC-1293) that differ by the chirality of only one amino acid. To increase the method sensitivity, electrokinetic preconcentration methods have been investigated. The large volume sample stacking with polarity switching (PS-LVSS) method with an injected sample volume corresponding to 80% of the capillary one was found superior to the sweeping in terms of signal enhancement factor (SEF). Acid and organic solvent addition to the sample (0.1 mM phosphoric acid with 30% methanol) led to a twofold signal improvement, when compared to water as a matrix. We increased capillary dimensions to provide a signal enhancement through the injection of a larger sample volume. Finally, using a combination of the optimized PS-LVSS preconcentration with the chiral capillary zone electrophoresis (CZE), the GHRH analogs were separated and limits of detection between 75 and 200 ng/mL were reached. This method was successfully applied to urine after a desalting step. An optimized C18 SPE was used for that purpose in order to provide low sample conductivity (<130 µS/cm) and preserve the efficiency of LVSS preconcentration. SEF of 640 was obtained with desalted urine spiked with sermorelin by comparison to the CZE (without preconcentration) method.  相似文献   

15.
This paper shows the potentiality of capillary electrophoresis (CE) coupled to mass spectrometry (MS) for the analysis of heterocyclic aromatic amines obtaining good results in terms of sensitivity and precision. These compounds have a special interest since they can be carcinogenic for humans. The optimization of a CE-MS method was performed and the best conditions were obtained using a 16 mM formic acid/ammonium formate solution at pH 4.5 with 60% methanol as running electrolyte. For CE-MS coupling, a sheath liquid methanol/20 mM formic acid (75/25) solution at a flow rate of 3 microL/min and hydrodynamic injection of methanol mixtures for 10 s were used. Detection limits ranging from 18 ng/g to 360 ng/g and precisions up to 1.4% and 12% for migration time and concentration, respectively, were obtained. In order to improve sensitivity, field-amplified sample injection was applied as an in-line preconcentration method. Methanol/5 mM formic acid (50/50) as a sample solvent, 3 s hydrodynamic injection (0.5 psi) of a methanol plug, and 25 s of electrokinetic injection (10 kV) of the sample were found to be the optimum conditions. Detection limits up to 25 times lower and similar precisions than those reported for hydrodynamic injection were obtained.  相似文献   

16.
A sweeping technique, in conjunction with micellar electrokinetic chromatography, for the simultaneous determination of flunitrazepam and its major metabolites, 7-aminoflunitrazepam and N-desmethylflunitrazepam, is described. The optimized conditions for the sweeping and separation were a pH 9.5 buffer, 25mM borate, 50mM cetyltrimethylammonium bromide, 30% MeOH (v/v), and a 151-mm injection length. The calibration functions were all linear with the coefficient of determination (r(2)) exceeding 0.996 for the three target compounds. Using the sweeping procedure, the limits of detection were determined to be 13.4, 5.6, and 12.0ng/mL for flunitrazepam, 7-aminoflunitrazepam, and N-desmethylflunitrazepam, respectively, and the sensitivity enhancement for each compound was within the range of 110-200 fold. The RSDs for the retention time and the peak area were less than 4.10%. The optimized sweeping method was also used to examine a spiked urine sample. We conclude that sweeping with micellar electrokinetic chromatography has considerable potential use in clinical and forensic analyses of flunitrazepam and its metabolites.  相似文献   

17.
Dextromethorphan is a centrally acting antitussive drug, while its enantiomer levomethorphan is an illicit drug with opioid analgesic effects. As capillary electrophoresis has been proven as an ideal technique for enantiomer analysis, the present study was conducted in order to develop a capillary electrophoresis‐based limit test for levomethorphan. The analytical target profile was defined as a method that should be able to determine levomethorphan with acceptable precision and accuracy at the 0.1 % level. From initial scouting experiments, a dual selector system consisting of sulfated β‐cyclodextrin and methyl‐α‐cyclodextrin was identified. The critical process parameters were evaluated in a fractional factorial resolution IV design followed by a central composite face‐centered design and Monte Carlo simulations for defining the design space of the method. The selected working conditions consisted of a 30/40.2 cm, 50 μm id fused‐silica capillary, 30 mM sodium phosphate buffer, pH 6.5, 16 mg/mL sulfated β‐cyclodextrin, and 14 mg/mL methyl‐α‐cyclodextrin at 20°C and 20 kV. The method was validated according to ICH guideline Q2(R1) and applied to the analysis of a capsule formulation. Furthermore, the apparent binding constants between the enantiomers and the cyclodextrins as well as complex mobilities were determined to understand the migration behavior of the analytes.  相似文献   

18.
Lin YH  Chiang JF  Lee MR  Lee RJ  Ko WK  Wu SM 《Electrophoresis》2008,29(11):2340-2347
A cation-selective exhaustive injection and sweeping micellar EKC (CSEI-Sweep-MEKC) was established to analyze morphine and its four metabolites, including codeine, normorphine (NM), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G). After SPE, the urine samples were analyzed by this CE method. The phosphate buffer (75 mM, pH 2.5) containing 30% methanol was first filled into an uncoated fused-silica capillary (40 cm, 50 microm id), then a high-conductivity buffer (120 mM phosphate, 10.3 kPa for 99.9 s) followed. The pretreated urine sample was loaded by electrokinetic injection (10 kV, 600 s). The stacking and separation were performed by using phosphate buffer (25 mM, pH 2.5) containing 22% methanol and 100 mM SDS at -20 kV, and detected at 200 nm. During method validation, calibration plots were linear (r > or = 0.998) over a range of 30-3000 ng/mL for morphine, NM, and codeine, 100-2000 ng/mL for M6G, and 80-3200 ng/mL for M3G. The LODs (S/N = 5, sampling 600 s at 10 kV) were 10 ng/mL for morphine, NM, and codeine, 35 ng/mL for M6G, and 25 ng/mL for M3G. This stacking CE method could increase 2500-fold sensitivity of codeine, when comparing with CZE. Five addicts' urine specimens were analyzed. Their results were compared with those of LC-MS-MS, and showed good coincidence. This method could be feasible for monitoring morphine and its metabolites in forensic interest and pharmacokinetic investigations.  相似文献   

19.
《Electrophoresis》2018,39(17):2195-2201
A sensitive, fast, and effective method, field‐amplified sample stacking (FASS) in capillary electrophoresis, has been established for the separation and determination of corynoxine and corynoxine B. Hydroxypropyl‐β‐CD (HP‐β‐CD) and tetrabutylammonium‐L‐glutamic acid (TBA‐L‐Glu) were used as additives in the separation system. Electrokinetic injection was chosen to introduce sample from inlet at 10 kV for 50 s after a water plug (0.5 psi, 4 s) was injected to permit FASS. The running buffer (pH 6.1) was composed of 40 mM sodium dihydrogen phosphate solution, 130 mM HP‐β‐CD, and 10 mM TBA‐L‐Glu and the separation voltage was 20 kV. Under the optimum conditions, corynoxine and corynoxine B were successfully enriched and separated within 12 min and the sensitivity was improved approximately by 700–900 folds. Calibration curves were in a good linear relationship within the range of 62.5–5.00 × 103 ng/mL for both corynoxine and corynoxine B. The limits of detection (S/N = 3) and quantitation (S/N = 10) were 14.9, 45.2 ng/mL for corynoxine and 11.2, 34.5 ng/mL for corynoxine B, respectively. Finally, this method was successfully applied for the determination of corynoxine and corynoxine B in the stems with hooks of Uncaria rhynchophylla and its formulations.  相似文献   

20.
Cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-Sweep-MEKC) was directly used to test some abuse drugs in human urine, including morphine (M), codeine (C), ketamine (K) and methamphetamine (MA). First, phosphate buffer (50 mM, pH 2.5) containing 30% methanol was filled into uncoated fused silica capillary (40 cm, 50 microm I.D.), then high conductivity buffer (100 mM phosphate, 6.9 kPa for 99.9 s) was followed. Electrokinetic injection (10 kV, 500 s) was used to load samples and to enhance sensitivity. The stacking step and separation were performed at -20 kV and 200 nm using phosphate buffer (25 mM, pH 2.5) containing 20% methanol and 100 mM sodium dodecyl sulfate. Using CSEI-Sweep-MEKC, the analytes could be simultaneously analyzed and have a detection limit down to ppb level. It was unnecessary to have sample pretreatments. During method validation, calibration plots were linear (r>or=0.9982) over a range of 150-3,000 ng/mL for M and C, 250-5,000 n g/mL for MA, and 50-1,000 ng/mL for K. The limits of detection were 15 ng/mL for M and C, and 5 ng/mL for MA and K (S/N=3, sampling 500 s at 10 kV). Comparing with capillary zone electrophoresis, the results indicated that this stacking method could increase 6,000-fold sensitivity for analysis of MA. Our method was applied for analysis of 28 real urine samples. The results showed good coincidence with immunoassay and GC-MS. This method was feasible for application to detect trace levels of abused drugs in forensic analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号