首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
There has been no assessment of the greenness of the described analytical techniques for the simultaneous determination (SMD) of caffeine and paracetamol. As a result, in comparison to the greener normal-phase high-performance thin-layer chromatography (HPTLC) technique, this research was conducted to develop a rapid, sensitive, and greener reversed-phase HPTLC approach for the SMD of caffeine and paracetamol in commercial formulations. The greenness of both techniques was calculated using the AGREE method. For the SMD of caffeine and paracetamol, the greener normal-phase and reversed-phase HPTLC methods were linear in the 50–500 ng/band and 25–800 ng/band ranges, respectively. For the SMD of caffeine and paracetamol, the greener reversed-phase HPTLC approach was more sensitive, accurate, precise, and robust than the greener normal-phase HPTLC technique. For the SMD of caffeine paracetamol in commercial PANEXT and SAFEXT tablets, the greener reversed-phase HPTLC technique was superior to the greener normal-phase HPTLC approach. The AGREE scores for the greener normal-phase and reversed-phase HPTLC approaches were estimated as 0.81 and 0.83, respectively, indicated excellent greenness profiles for both analytical approaches. The greener reversed-phase HPTLC approach is judged superior to the greener normal-phase HPTLC approach based on numerous validation parameters and pharmaceutical assays.  相似文献   

2.
A simple, rapid, and efficient method using TLC with a fluorescence plate reader has been described for simultaneous determination of caffeine and paracetamol. Determination was carried out using the fluorescence-quenching action of caffeine and paracetamol on a TLC plate with a fluorescent indicator at lambda ex = 254 nm in the linear ranges of 0.2-1.9 and 0.03-1.5 microg/L, respectively. Separation of caffeine and paracetamol were performed on the TLC plate, and the best results were obtained using the optimized mobile phase n-hexane-ethyl acetate-ethanol (2.5 + 1.5 + 0.4, v/v). Some important parameters, such as solvent type and ratio of the mobile phase, the presence of other components, and instrumental parameters, were studied. Caffeine and paracetamol detection limits were 0.025 and 0.032 microg/L, and RSD values for 0.6 microg/L caffeine and 0.06 microg/L paracetamol (n = 5) were 1.93 and 2.06%, respectively. Using this technique, some pharmaceuticals containing caffeine and paracetamol were analyzed with satisfactory results.  相似文献   

3.
Citicoline and piracetam were subjected separately to different stress conditions as recommended by the international conference on harmonization. In addition, new stability indicating thin layer chromatographic and ultra high performance liquid chromatographic methods have been developed and validated for simultaneous determination of citicoline and piracetam in presence of their degradation products. Separation on the proposed thin layer chromatographic method was carried out using a developing system containing methanol:chloroform:ammonium chloride buffer (9:1:2, v/v/v) on silica gel plates at 230 nm. On the other hand, the mobile phase in the ultra high performance liquid chromatographic method was composed of water (containing 0.1% triethylamine):ethanol (92:8, v/v). The flow rate was 1 mL/min and ultraviolet detection was at 230 nm. Moreover, results of the developed methods were statistically compared to those obtained by the reported high‐performance liquid chromatography method and no significant difference between them was found. The greenness profile of ultra high performance liquid chromatographic method was assessed and compared with those of the previously published high‐performance liquid chromatography methods, it was noticed that the proposed ultra high performance liquid chromatographic method more environmentally friendly and greener than other methods.  相似文献   

4.
A new high-throughput method is developed to quantify caffeine, ergotamine, and metamizol in a solid pharmaceutical formulation. After dissolution, the compounds are separated on silica gel 60 F(254) high-performance thin-layer chromatography (HPTLC) plates with ethyl acetate-methanol-ammonia 90:15:1 (v/v/v) as the mobile phase. Detection is performed by UV absorption at 274 nm for caffeine and metamizol, and by fluorescence at 313 /> 340 nm for ergotamine. Calibrations are linear or polynomial with determination coefficients (R(2)) >or= 0.9986. Recoveries of the three compounds are between 95% and 102% at three different concentration levels. Repeatability [relative standard deviation (RSD)] of all substances in the matrix is between +/- 0.9% and +/- 1.7%. Intermediate precision (RSD) of the three compounds range from +/- 2.0% to +/- 3.1%. Mass confirmation is performed by a single quadrupole mass spectrometry in positive electrospray ionization full scan mode for caffeine and ergotamine and in negative mode for metamizol. The results proved that this method is a simple and reliable alternative for routine analysis.  相似文献   

5.
A simple and reliable precolumn derivatization liquid chromatography method with ultraviolet detection has been developed and validated for the analysis of glucosamine (GS) in various dietary supplement formulations and raw materials. Additionally, the proposed method was used for analysis of carisoprodol (CR) found in ternary mixture with paracetamol (PR) and caffeine (CF). The linearity ranges were 1-100 μg/mL for GS, 1-150 μg/mL for CR, PR and CF. Derivatization was used with 1,2-naphthoquinone-4-sulphonic acid sodium salt in the presence of borate buffer. Chromatographic separation of GS-naphthoquinone derivative was achieved by using a mixture of acetonitrile and water (pH 7.3 adjusted with 0.1 M NaOH) in the ratio 10:90, v/v and flow-rate of 1.0 mL/min. UV detection was carried out at 280 nm. For PR, CF, and CR-naphthoquinone derivative, the chromatographic separation was achieved by using mixture of acetonitrile and 20 mM KH(2)PO(4) (pH 3.0 adjusted with phosphoric acid) in the ratio 20:80, v/v and flow-rate of 1.0 mL/min. UV detection was carried out at 275 nm. The limits of detection were 37.2, 35.9, 30.4 and 40.0 ng/mL for GS, CR, PR and CF, respectively.  相似文献   

6.
Green chemistry and sustainability is now entirely encompassed across the majority of pharmaceutical companies and research labs. Researchers’ attention is careworn toward implementing the green analytical chemistry principles for more eco‐friendly analytical methodologies. Solvents play a dominant role in determining the greenness of the analytical procedure. Using safer solvents, the greenness profile of the methodology could be increased remarkably. In this context, a green chromatographic method has been developed and validated for the simultaneous determination of phenylephrine, paracetamol, and guaifenesin in their ternary pharmaceutical mixture. The chromatographic separation was carried out using monolithic column and green solvents as mobile phase. The use of monolithic column allows efficient separation protocols at higher flow rates, which results in short time of analysis. Two‐factor three‐level experimental design was used to optimize the chromatographic conditions. The greenness profile of the proposed methodology was assessed using eco‐scale as a green metrics and was found to be an excellent green method with regard to the usage and production of hazardous chemicals and solvents, energy consumption, and amount of produced waste. The proposed method improved the environmental impact without compromising the analytical performance criteria and could be used as a safer alternate for the routine analysis of the studied drugs.  相似文献   

7.
This paper describes a rapid reversed-phase liquid chromatographic method, with UV detection, for the simultaneous determination of acetylsalicylic acid, caffeine, codeine, paracetamol, pyridoxine, and thiamine in pharmaceutical preparations. A reversed-phase C18 Nucleosil column is used. The mobile phase consists of 2 successive eluants: water (5 min) and acetonitrile-water (75 + 25, v/v; 9 min), both adjusted to pH 2.1 with phosphoric acid. Before determination acetylsalicylic acid is completely converted to salicylic acid by alkaline hydrolysis. Salicylic acid, caffeine, paracetamol, pyridoxine, and thiamine are all detected at 285 nm, whereas codeine is detected at 240 nm. Calibration curves were linear for salicylic acid, caffeine, paracetamol, and pyridoxine in the range of 50-500 mg/L, and for codeine and thiamine in the range of 50-1000 mg/L. The method was applied to the analysis of 13 fortified commercial pharmaceutical preparations. Recoveries ranged from 92.6 to 105.5%, with relative standard deviations of 1.1-5.8%.  相似文献   

8.
The separation and simultaneous determination of caffeine, paracetamol, and acetylsalicylic acid in two analgesic tablet formulations was investigated by capillary electrochromatography (CEC). The effect of mobile phase composition on the separation and peak efficiency of the three analytes was studied and evaluated; in particular, the influence of buffer type, buffer pH, and acetonitrile content of the mobile phase was investigated. The analyses were carried out under optimized separation conditions, using a full-packed silica capillary (75 microm ID; 30.0 cm and 21.5 cm total and effective lengths, respectively) with a 5 microm C8 stationary phase. A mixture of 25 mM ammonium formate at pH 3.0 and acetonitrile (30:70 v/v) was used as the mobile phase. UV detection was at 210 nm. Good linearity was found in the range of 50-200, 20-160, and 4-20 microg/mL for acetylsalicylic acid (r2=0.9988), paracetamol (r2=0.9990) and caffeine (r2=0.9990), respectively. Intermediate precision (RSD interday) as low as 0.1-0.8% was found for retention times, while the RSD values for the peak area ratios (Aanalyte/AIS) were in the range of 1.9-2.9%. The optimized CEC method was applied to the analysis of the studied compounds present in commercial tablets.  相似文献   

9.
Paracetamol, caffeine and ibuprofen are found in over‐the‐counter pharmaceutical formulations. In this work, we propose two new methods for simultaneous determination of paracetamol, caffeine and ibuprofen in pharmaceutical formulations. One method is based on high‐performance liquid chromatography with diode‐array detection and the other on capillary electrophoresis with capacitively coupled contactless conductivity detection. The separation by high‐performance liquid chromatography with diode‐array detection was achieved on a C18 column (250×4.6 mm2, 5 μm) with a gradient mobile phase comprising 20–100% acetonitrile in 40 mmol L?1 phosphate buffer pH 7.0. The separation by capillary electrophoresis with capacitively coupled contactless conductivity detection was achieved on a fused‐silica capillary (40 cm length, 50 μm i.d.) using 10 mmol L?1 3,4‐dimethoxycinnamate and 10 mmol L?1 β‐alanine with pH adjustment to 10.4 with lithium hydroxide as background electrolyte. The determination of all three pharmaceuticals was carried out in 9.6 min by liquid chromatography and in 2.2 min by capillary electrophoresis. Detection limits for caffeine, paracetamol and ibuprofen were 4.4, 0.7, and 3.4 μmol L?1 by liquid chromatography and 39, 32, and 49 μmol L?1 by capillary electrophoresis, respectively. Recovery values for spiked samples were between 92–107% for both proposed methods.  相似文献   

10.
A new humic acid based stationary phase has been used, for the first time, to achieve the separation and quantification of paracetamol and caffeine in pharmaceutical preparations under reversed‐phase high‐performance liquid chromatography conditions. Central composite design was applied as a powerful tool to optimize the most dominant parameters that influence the resolution of reversed‐phase high‐performance liquid chromatography, that is, mobile phase composition (acetonitrile percentage in water), flow rate, and column temperature. The optimum conditions were obtained as 21.69%, 1.5 mL/min, and 15°C, respectively, with the aid of a second‐order quadratic model and desirability function. Under the optimum conditions, the peaks could be baseline separated within 10 min. For the developed reversed‐phase high‐performance liquid chromatography method, the linearity was investigated in the concentration ranges of 2–160 mg/mL (R2 = 0.999) for paracetamol and 2–9.9 mg/mL (R2 = 0.991) for caffeine. Mean recoveries for paracetamol and caffeine were 95.90 and 95.68%, respectively. The limits of detection and quantification were 4.1 × 10‐4 and 1.3 × 10‐3 mg/mL for paracetamol and 1.6 × 10‐4 and 5.0 × 10‐4 mg/mL for caffeine. The results showed that the new humic acid based stationary phase is very suitable for the separation of paracetamol and caffeine in pharmaceutical preparations and, thus it can be used effectively in the pharmaceutical industry.  相似文献   

11.
《Electroanalysis》2017,29(3):907-916
A porous electrode material combining the features of vertically aligned multi‐walled carbon nanotubes (VAMWCNT) and diamond‐like carbon films (DLC) have been developed for a highly sensitive electrochemical sensor. For working electrode preparation, DLC has been grown onto VAMWCNT, forming a porous, conductive and stable composite. The electrochemical performance of this DLC:VAMWCNT electrode has been investigated toward detection and analysis of three well‐known molecules, namely paracetamol, codeine and caffeine. A ternary mixture of these analytes was simultaneously determined under optimum experimental conditions using square‐wave voltammetry. Wide linear concentration ranges and the limits of detection of 3.34×10−7 mol L−1, 1.57×10−7 mol L−1 and 3.67×10−7 mol L−1 were obtained for paracetamol, codeine and caffeine, respectively. We conclude that the proposed voltammetric method and the DLC:VAMWCNT electrode comprise a reliable methodology for simultaneous determination of paracetamol, codeine and caffeine in biological matrix samples.  相似文献   

12.
A simple, specific and accurate isocratic RP-HPLC-DAD method was developed for the simultaneous determination of phenylephrine, paracetamol, caffeine and chlorpheniramine in bulk and tablet dosage form. The four contents are present in variable concentrations and have variable chromatographic behavior making the process of analysis very difficult. For present studies a reversed-phase C-18 column (150 mm × 4.5 mm i.d., particle size 5 μm) with mobile phase consisting of acetonitrile, methanol and 10 Mm phosphate buffer 16:22:62 (v/v) (pH of buffer 2.5 ± 0.02, adjusted with ortho phosphoric acid) was used. The flow rate was 1.0 ml/min and eluents were monitored at 280 nm. The mean retention times of phenylephrine, paracetamol, caffeine and chlorpheniramine were found to be 1.8, 3.1, 5.2 and 10.9 min, respectively. The method was validated in terms of linearity, range, specificity, accuracy, precision and robustness. The proposed method was successfully applied to the estimation of phenylephrine, paracetamol, caffeine and chlorpheniramine in combined tablet dosage form.  相似文献   

13.
A method is described for the simultaneous determination of paracetamol, tizanidine, and diclofenac in mixtures. The method was based on HPLC separation of the three drugs followed by UV detection at 254 nm. The separation was carried out on a Hypersil ODS, C18 (250 x 4.6 mm id, 10 microm particle size) column using the mobile phase aqueous 0.2% ammonium carbonate-methanol (60 + 40, v/v) at a flow rate of 1 mL/min. The linear regression analysis data were used for the regression curve in the range of 170-10 000 ng/mL for paracetamol, 120-10 000 ng/mL for tizanidine, and 20-10 000 ng/mL for diclofenac. No chromatographic interference from tablet excipients was found. In order to check the selectivity of the proposed method, degradation studies were carried out using hydrolysis (acid, basic, and neutral), thermolysis, and oxidation. The developed method, after being validated in terms of precision, robustness, recovery, LOD, and LOQ, was successively applied to the analysis of pharmaceutical formulations and human serum.  相似文献   

14.
A method is described for quantitating caffeine, theobromine, theophylline, paracetamol, propyphenazone, acetylsalicylic acid, salicylic acid, and codeine phosphate in corresponding real samples of food, beverages, natural products, pharmaceuticals, and cosmetic preparations by micellar electrokinetic capillary chromatography. The separation is carried out at 25 degrees C and 25 kV, using a 20mM phosphate buffer (pH 9.0), 80mM sodium dodecyl sulfate, and 7.5% (v/v) acetonitrile. UV detection is at 210 nm. The method is shown to be specific, accurate (recoveries over the range 98.9-101.2%), linear over the tested range (correlation coefficients >/= 0.9993), and precise (relative standard deviation below 2.1%). The method is applied for the quantitative analysis of these compounds in different foods, beverages, natural products, pharmaceuticals, and cosmetic products.  相似文献   

15.
A micellar liquid chromatographic technique allowing the separation and simultaneous determination of the active ingredients paracetamol, caffeine, and guaifenesin, and preservatives benzoic acid, methyl and propyl paraben is described. The separation was effective by using the Kromasil C18 column (150 mm × 4.6 mm, 5 μm) and a mobile phase of 1-butanol:water (1:99, v/v), containing 0.04 M sodium dodecyl sulfate and 0.1% (v/v) trichloroacetic acid, for eluting all compounds. The detection wavelength was set as 260 nm. The column heater was also used, set at 40 °C for these determinations. Under these conditions, separation of the six components was achieved in less than 30 min. The specificity of the method was demonstrated. Analytical characteristics such as limit of detection, limit of quantification, linear range, accuracy, precision (repeatability) and the influence of the various method parameters (robustness study) were evaluated. The developed method was applied to the determination of paracetamol, caffeine, guaifenesin, benzoic acid (sodium benzoate), methyl and propyl paraben in cough-drop syrups. Presented at the International Conference “Modern physical chemistry for advanced materials (devoted to the 100th birthday of Professor Nikolai Izmailov)”, Kharkov, Ukraine, June 2007.  相似文献   

16.
Simple, sensitive and accurate thin layer procedure was described for a quantitative determination of paracetamol in its bulk powder and in its pharmaceutical dosage forms in the presence of its degradation product. The method consists of dissolving the drug in methanol and then spotting the solution on a thin layer of silica gel G254. Paracetamol was separated on silica gel using the mixture of the mobile phase, ethyl acetate: benzene: acetic acid in a ratio (1:1:0.05 v/v/v).Absorbance measurements (detection of reflectance) of the separated drug were carried out at 250 nm. Calibration curves were established in the concentration range of 5–20 mcg/spot for paracetamol. Quantitation is achieved by comparing the area under the peaks obtained from scanning the thin layer chromatographic plates in a spectrodensitometer. The method has been successfully applied to pharmaceutical preparations (capsules) and the results obtained were statistically compared with those obtained by applying the reference method.  相似文献   

17.
Interest in implementing green chemistry principles in analytical chemistry has grown dramatically in the past few years. The solvents used have the major influence on the greenness of the method. Most conventional high‐performance liquid chromatography methods employed utilize solvents that are “hazardous for the environment”. In the present study, two‐factor three‐level response surface design was exploited to develop eco‐friendly chromatographic methods for two different mixtures. The first one was atorvastatin and amlodipine and the second one was amlodipine, perindopril, and indapamide. As it is nontoxic to the environment, ethanol was used as the organic modifier in the mobile phase. The separation of the first mixture was attained using phosphate buffer (pH 7)/ethanol (42:58 v/v), and the second mixture was fully resolved using phosphate buffer (pH 5)/ethanol (40:60 v/v). The use of high‐performance liquid chromatography allows excellent resolution in a short run time, hence, less waste was produced. The greenness of the developed methods was assessed by two evaluation tools, namely, National Environmental Methods Index and analytical eco‐scale, and found to be excellent green analytical methods. Moreover, the developed methods were compared with other reported methods regarding accuracy and greenness and were found to be perfect alternatives to reported methods for separation and quantification of the mixtures.  相似文献   

18.
In this contribution, a new separation method for simultaneous determination of paracetamol, caffeine, acetylsalicylic acid, and internal standard benzoic acid was developed based on a novel reversed-phase sequential injection chromatography (SIC) technique with UV detection. A Chromolith Flash RP-18e, 25-4.6mm column (Merck, Germany) and a FIAlab 3000 system (USA) with an 8-port selection valve and a 5 mL syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-(0.01 M) phosphate buffer (10:90, v/v) pH 4.05, flow rate 0.6 mL min(-1). UV detection was at 210 and 230 nm. The validation parameters showed good results: linearity (r >0.999) for all compounds, detection limits in the range 0.3-0.8 microg mL(-1), repeatability (RSD) of peak heights between runs in the range 1.10-4.30% at three concentration levels and intra-day repeatability of the retention times in the range 0.28-0.43%. The analysis time was <6 min. The method was found to be applicable for the routine analysis of the active compounds paracetamol, caffeine, and acetylsalicylic acid in pharmaceutical tablets.  相似文献   

19.
Caffeine (1,3,7-trimethylxanthine), theobromine (3,7-dimethylxanthine) and theophylline (1,3-dimethylxanthine) are the most important naturally occurring methylxanthines. Caffeine is a constituent of coffee and other beverage and included in many medicines. Theobromine and theophylline are formed as metabolites of caffeine in humans, and are also present in tea, cocoa and chocolate products.

In order to improve the chromatographic resolution (Rs) with a good analysis time, experimental designs were applied for multivariate optimisation of the experimental conditions of an isocratic reversed-phase high-performance liquid chromatographic (RP-HPLC) method used for the simultaneous determination of caffeine, theobromine and theophylline. The optimisation process was carried out in two steps using full three-level factorial designs. The factors optimised were: flow rate and mobile phase composition. Optimal conditions for the separation of the three methylxanthines were obtained using a mixture of water/ethanol/acetic acid (75:24:1%, v/v/v) as mobile phase and a flow rate of 1.0 mL min−1. The RP-HPLC/UV method was validated in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, recovery and the precision, calculated as relative standard deviation (R.S.D.). In these conditions, the LOD was 0.10 μg L−1 for caffeine, 0.07 μg L−1 for theobromine and 0.06 μg L−1 for theophylline. The proposed method is fast, requires no extraction step or derivatization and was suitable for quantification of these methylxanthines in coffee, tea and human urine samples.  相似文献   


20.
A simple, sensitive and rapid method has been developed and validated for determination of the metoclopramide (MCP) in 100 μL human plasma. The analytical procedure involves a liquid–liquid extraction method using tramadol as an internal standard (IS). Chromatographic separation was carried out on a HyPURITY ADVANCE column using a mobile phase consisting of acetonitrile and 10 mm ammonium acetate buffer in the ratio of 80:20 (v/v) at a flow rate of 0.3 mL/min. The total run time of analysis was 2.5 min and elution of MCP and IS occurred at 0.9 and 1.3 min, respectively. A linear response function was established for the range of concentrations 0.53–42.07 ng/mL (r > 0.99). The intra‐ and inter‐day precision values for MCP met the acceptance as per FDA guidelines. MCP was stable in a battery of stability studies viz., bench‐top, auto‐sampler and freeze–thaw cycles. The developed assay method was successfully applied to an oral bioequivalence study in humans. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏