首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
Simultaneous electropolymerization of 3‐methylthiophene and incorporation of Laccase (LAC) was carried out in the presence of propylene carbonate as a medium by amperometric method. This enzyme modified electrode was used for the sensing of polyphenol. Catechol is taken as a model compound for the study. UV‐Vis spectral studies suggest no denaturation of LAC in presence of propylene carbonate. The SEM studies reveal the surface morphology and incorporation of LAC in P3MT with agglomerated flaky masses are observed in with and without enzyme micrographs. The cyclic voltammograms were recorded for 0.01 mM catechol on plain glassy carbon, polymer and enzyme incorporated electrodes at pH 6.0 and scan rate 50 mV s?1. The fabricated electrochemical biosensor was used for the determination of catechol in aqueous solution by Differential Pulse Voltammetry (DPV) technique. The concentration linear range of 8×10?8 to 1.4×10?5 M a value of Michealis? Menten constant Km=7.67 µmol dm?3 and activation energy is 32.75 kJ mol?1. It retains 83 % of the original activity after 60 days which is much higher than that of other biosensors. The developed biosensor was used to quantify catechol in the determination in real samples.  相似文献   

2.
A new photoelectrochemical (PEC) biosensor was developed by using carboxyl‐functionalized graphene and CdSe nanoparticles. This sensitive interface was then successfully applied to detection of thrombin based on the dual‐quenched effect of PEC nanoparticle, which relied on the electron transfer of a bipyridinium relay and energy transfer of AuNPs. After recognition with an aptamer, the PEC nanoparticle was removed and a signal‐on PEC biosensor was obtained. Moreover, the bio‐barcode technique used in the preparation of PEC nanoparticle could avoid cross‐reaction and enhances the sensitivity. Taking advantages of the various methods mentioned above, the sensitivity could be easily enhanced. In addition, in this work we also investigated graphene that was modified with different functional groups and AuNPs of different particle sizes. Under optimal conditions, a detection limit of 5.9×10?15 M was achieved. With its simplicity, selectivity, and sensitivity, this strategy shows great promise for the fabrication of highly efficient PEC biosensors.  相似文献   

3.
The highly efficient H2O2 biosensor was fabricated on the basis of the complex films of hemoglobin (Hb), nano ZnO, chitosan (CHIT) dispersed solution and nano Au immobilized on glassy carbon electrode (GCE). Biocompatible ZnO‐CHIT composition provided a suitable microenvironment to keep Hb bioactivity (Michaelis‐Menten constant of 0.075 mmol L?1). The presence of nano Au in matrix could effectively enhance electron transfer between Hb and electrode. The electrochemical behaviors and effects of solution pH values were carefully examined in this paper. The (ZnO‐CHIT)‐Au‐Hb/GCE demonstrated excellently electrocatalytical ability for H2O2. This biosensor had a fast response to H2O2 less than 4 s and excellent linear relationships were obtained in the concentration range from1.94×10?7 to 1.73×10?3 mol L?1 with the detection limit of 9.7×10?8 mol L?1 (S/N=3) under the optimum conditions. Moreover, the stability and reproducibility of this biosensor were evaluated with satisfactory results.  相似文献   

4.
《Electroanalysis》2017,29(4):1031-1037
This paper describes the synthesis and characterization of gold nanoparticles stabilized in β‐cyclodextrin (AuNP‐CD), which were applied as a platform in the immobilization of laccase (LAC). The AuNP‐CD‐LAC were used in the construction of a new biosensor for rutin determination by square‐wave voltammetry (SWV). Under optimized conditions, the calibration curve showed a linear range for rutin of 0.30 to 2.97 μmol L−1, with a limit of detection of 0.17 μmol L−1. The biosensor demonstrated satisfactory repeatability and electrode‐to‐electrode repeatability (with relative standard deviations of 5.6 and 6.0 %, respectively) and good stability. The biosensor was successfully applied in the determination of rutin in different pharmaceutical samples.  相似文献   

5.
A hydrogen peroxide (H2O2) biosensor based on the combination of Au@Ag core‐shell nanoparticles with a hemoglobin‐chitosan‐1‐butyl‐3‐methyl‐imidazolium tetrafluoroborate (Hb‐CHIT‐BMIM×BF4) composite film was prepared. UV‐vis spectroscopy and transmission electron microscopy confirmed a core‐shell nanostructure of Au@Ag nanoparticle was successfully obtained. Cyclic voltammetric results showed a pair of well‐defined redox peaks appeared with the formal potential (EO′) of ‐0.301 V (versus Ag/AgCl reference electrode) and the peak‐to‐peak separation (ΔEp) was 84 mV in 0.1 M phosphate buffer solutions. Due to the synergetic effect of Au@Ag core‐shell nanoparticles and Hb‐CHIT‐BMIM×BF4, the biosensor exhibited good electrocatalytic activity to the reduction of H2O2 in a linear range from 1.0 × 10?6 to 1.0 × 10?3 M with a detection limit of 4 × 10?7 M (S/N = 3). The apparent Michaelis‐Menten constant (KM) was estimated to be 4.4 × 10?4 M, showing its high affinity. Thus, the study proved that the combination of Au@Ag core‐shell nanoparticles and Hb‐CHIT‐BMIM×BF4 is able to open up new opportunities for the design of enzymatic biosensors.  相似文献   

6.
《Electroanalysis》2005,17(23):2147-2155
A laccase biosensor, in which the enzyme was immobilized on N‐succinimidyl‐3‐thiopropionate (NSTP)‐modified gold electrodes, is reported. Two different approaches for the preparation of N‐succinimidyl‐terminated monolayers were evaluated: a) activation of a preformed 3‐mercaptopropionic acid (MPA) SAM by reaction with 1‐(3‐dimethylaminopropyl)‐ 3‐ethylcarbodiimide (EDC) and N‐hydroxysulfosuccinimide (NHS); b) assembling of dithiobisuccinimidyl propionate (DTSP). NSTP‐modified electrodes were characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Biosensors prepared by covalent binding of the enzyme and by cross‐linking with glutaraldehyde atop NSTP‐modified electrodes were compared in terms of sensitivity and operational range for caffeic acid. A much better analytical performance was found using the latter approach. Variables affecting the amperometric detection (enzyme loading, pH and applied potential) were optimized. The operational stability and characteristics of functioning of the laccase biosensor in terms of repeatability of the amperometric measurements, reproducibility with different biosensors and useful lifetime, were evaluated. The kinetic parameters of the enzyme reactions and the analytical characteristics of the corresponding calibration plots were calculated for eight phenolic compounds. Limits of detection of 0.07 μM, 0.05 μM and 0.09 μM were obtained for caffeic acid, catechol and 3,4‐dihydroxyphenylacetic acid (DOPAC), respectively. The practical usefulness of the developed biosensor was evaluated by estimating the “pool” of phenolic compounds in olive oil mill wastewaters (OMW).  相似文献   

7.
《Analytical letters》2012,45(12):1842-1853
A biosensor was fabricated by incorporating laccase in a ZnO sol-gel with chitosan as a matrix for the determination of catechol. The ZnO nanoparticles were characterized by X-ray diffraction and atomic force microscopy. The conductivity of the chitosan/ZnO/glassy carbon electrode film was investigated by alternating current impedance. The biosensor was employed to monitor the reduction of catechol, and the peak current increased linearly with concentration between 1.0 × 10?6 and 1.0 × 10?4 mole per liter with a limit of detection of 2.9 × 10?7 mole per liter. The laccase biosensor exhibited good stability, reproducibility, and some selectivity.  相似文献   

8.
A matrix comprising iridium nanoparticles and 1‐butyl‐3‐methylimidazolium tetrafluoroborate ionic liquid (Ir‐BMI.BF4) supported in montmorillonite (MMT) was obtained through an efficient incorporation process. This modified clay matrix (Ir‐BMI.BF4‐MMT) was used for the immobilization of the enzymes laccase (LAC) and polyphenol oxidase (PPO) and employed in the construction of a bi‐enzymatic biosensor for determination of rutin by square‐wave voltammetry. Under optimized conditions, the analytical curve showed a linear range for rutin concentrations from 9.17×10?8 to 3.10×10?6 mol L?1 with a detection limit of 3.09×10?8 mol L?1. The method was successfully applied to the determination of rutin content in pharmaceutical samples.  相似文献   

9.
《Analytical letters》2012,45(15):2537-2547
A promising nanotechnological material, zirconia nanoparticles modified with SiO2, was used as a medium for the immobilization of laccase to construct a novel biosensor that exhibits sensitive amperometric response to catechol in 0.1 mol · L?1 phosphate buffer (pH 6.0) using cyclic voltammetry. The linear response to catechol was from 1.0 × 10?6 to 1.0 × 10?4 mol · L?1 and the detection limit was 3.5 × 10?7 mol · L?1 at a signal-to-noise ratio of 3. The biosensor exhibited good stability, precision, and few interferences.  相似文献   

10.
Here we report the first mediated pain free microneedle‐based biosensor array for the continuous and simultaneous monitoring of lactate and glucose in artificial interstitial fluid (ISF). The gold surface of the microneedles has been modified by electrodeposition of Au‐multiwalled carbon nanotubes (MWCNTs) and successively by electropolymerization of the redox mediator, methylene blue (MB). Functionalization of the Au‐MWCNTs/polyMB platform with the lactate oxidase (LOX) enzyme (working electrode 1) and with the FAD‐Glucose dehydrogenase (FADGDH) enzyme (working electrode 2) enabled the continuous monitoring of lactate and glucose in the artificial ISF. The lactate biosensor exhibited a high sensitivity (797.4±38.1 μA cm?2 mM?1), a good linear range (10–100 μM) with a detection limit of 3 μM. The performance of the glucose biosensor were also good with a sensitivity of 405.2±24.1 μA cm?2 mM?1, a linear range between 0.05 and 5 mM and a detection limit of 7 μM. The biosensor array was tested to detect the amount of lactate generated after 100 minutes of cycling exercise (12 mM) and of glucose after a normal meal for a healthy patient (10 mM). The results reveal that the new microneedles‐based biosensor array seems to be a promising tool for the development of real‐time wearable devices with a variety of sport medicine and clinical care applications.  相似文献   

11.
《Electroanalysis》2005,17(23):2114-2120
The biopolymer chitosan (CHIT) was chemically modified with glutaric dialdehyde (GDI) and used for the covalent immobilization of enzyme glutamate oxidase (GmOx). The relationships between the loaded, retained, and active units of GmOx in the CHIT‐GDI‐GmOx gels were determined by electrochemical assays. The latter indicated that on average ca. 95% of the GmOx was retained in the CHIT‐GDI matrix that was loaded with 0.10–3.0 units of the enzyme. The maximum activity of the GmOx immobilized in the gels corresponded to ca. 5% of the activity of the free enzyme. Platinum electrodes coated with CHIT‐GDI‐GmOx gels (films) were used as amperometric biosensors for glutamate. Such biosensors displayed good operational and long‐term stability (at least 11 h and 100 days, respectively) in conjunction with low detection limit of 0.10 μM glutamate (S/N=3), linear range up to 0.5 mM (R2=0.991), sensitivity of 100 mA M?1 cm?2, and short response time (t90%=2 s). This demonstrated an efficient signal transduction in the Pt/CHIT‐GDI‐GmOx+glutamate system. The CHIT‐GDI‐GmOx gels constitute a new biosensing element for the development of glutamate biosensors.  相似文献   

12.
《Analytical letters》2012,45(5):875-886
Abstract

Platinum nanowires (PtNW) were prepared by an electrodeposition strategy using nanopore alumina template. The nanowires prepared were dispersed in chitosan (CHIT) solution and stably immobilized onto the surface of glassy carbon electrode (GCE). The electrochemical behavior of PtNW‐modified electrode and its application to the electrocatalytic reduction of hydrogen peroxide (H2O2) are investigated. The modified electrode allows low potential detection of hydrogen peroxide with high sensitivity and fast response time. As an application example, the glucose oxidase was immobilized onto the surface of PtNW‐modified electrode through cross‐linking by glutaric dialdehyde. The detection of glucose was performed in phosphate buffer at –0.2 V. The resulting glucose biosensor exhibited a short response time (<8 s), with a linear range of 10?5?10?2 M and detection limit of 5×10?6 M.  相似文献   

13.
Mesoporous titania‐Nafion composite doped with carbon nanotube (CNT) has been used for the immobilization of tris(2,2′‐bipyridyl)ruthenium(II) (Ru(bpy)32+) and alcohol dehydrogenase on an electrode surface to yield a highly sensitive and stable electrogenerated chemiluminescence (ECL) ethanol biosensor. The presence of CNT in the composite film increases not only the sensitivity of the ECL biosensor but also the long‐term stability of the biosensor. The present biosensor responds linearly to ethanol in the wide concentration ranges from 1.0×10?5 M to 1.0×10?1 M with a detection limit of 5.0×10?6 M (S/N=3). The present ECL ethanol biosensor exhibited higher ECL response compared to that obtained with the ECL biosensor based on the corresponding composite without CNT. The present CNT‐based ECL biosensor showed good long‐term stability with 75% of its initial activity retained after 2 weeks of storage in 50 mM phosphate buffer at pH 7.0.  相似文献   

14.
A visible‐light driven photoelectrochemical (PEC) sensor based on aptamer immobilized TiO2‐Fe2O3 nanotubes was proposed for the first time and highly sensitive and selective bisphenol A determination was realized. Taking advantage of the alloy oxide nanotube structure, high surface area, good biocompatibility, superior photoelectrocatalytic performance, a limit of detection toward BPA as low as 1.8×10?11 M with linearity in the range from 1.8×10?11 to 3.2×10?9 M could be achieved. Specificity was greatly exhibited for this aptasensor under 100‐fold excess concentration of estriol, resorcinol, nonylphenol, 2,4‐D, acetamiprid, chlorpyrifos and omethoate. Simultaneously, satisfactory results were obtained in real water sample investigation from industrial plastics and drinking water. A novel visible‐light driven PEC method for highly sensitive and selective detection of BPA was thus established.  相似文献   

15.
This work evaluated an amperometric biosensor based on multi‐wall carbon nanotubes (MWCNT), chemically modified with methylene blue (Met) and horseradish peroxidase (HRP), for detection of phenolic compounds. The dependences of the biosensor response due to the enzyme immobilization procedure, HRP amounts, pH and working potential were investigated. The amperometric response for catechol using the proposed biosensor showed a very wide linear response range (1 to 150 μmol L?1), good sensitivity (50 nA cm?2 μmol?1 L), excellent operational stability (after 300 determinations the response remained at 97%) and very good storage stability (lifetime>3 months). Based on all these characteristics, it is possible to affirm that the material is promising for phenol detection due to its good electrochemical response and enzyme stabilization. The biosensor response for various phenolic compounds was investigated.  相似文献   

16.
A simple one‐step electrodeposition method is described to fabricate three dimensional ordered macroporous chitosan?prussian blue?single walled carbon nanotubes (3DOM CS?PB?SWCNTs) film onto the gold electrode surface to fabricate a copper ions (Cu2+)‐specific DNAzyme biosensor. The new sensing strategy for sensitive and selective detection of Cu2+ was based on Au nanorods (AuNRs) as signal amplification labels. The electrochemical signal of glucose increased with the concentration of Cu2+ increasing. The morphologies and electrochemistry of the composites were investigated by using scanning electron microscopy (SEM), transmission electron microscopy (TEM) and electrochemical techniques including cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) and so on. Linear correlations of copper ion concentration were obtained in the range from 10?18 M to 10?5 M, achieving with a limit of detection of 10?19 M (S/N=3). Parameters affecting the biosensor response such as temperature, the cleavage time and the time of hybridization were optimized. This biosensor showed a wide range, low detection limit, good reproducibility and high stability. Additionally, these striking properties endow the biosensor with a great promise for analytical applications.  相似文献   

17.
An amperometric tyramine biosensor based on poly‐L‐lysine (PLL) and Fe3O4 nanoparticles (Fe3O4NP) modified screen printed carbon electrode (SPCE) was developed. PLL was formed on the SPCE by the electropolymerization of L‐lysine. Subsequently, Fe3O4NP suspension prepared in chitosan (CH) solution was casted onto the PLL/SPCE. Tyrosinase (Ty) enzyme was immobilized onto the modified Fe3O4?CH/PLL/SPCE and the electrode was coated with Nafion to fabricate the Ty/Fe3O4?CH/PLL/SPCE. Different techniques including scanning electron microscopy, chronoamperometry (i–t curve), cyclic voltammetry and electrochemical impedance spectroscopy were utilized to study the fabrication processes, electrochemical characteristics and performance parameters of the biosensor. The analytical performance of the tyramine biosensor was evaluated with respect to linear range, sensitivity, limit of detection, repeatability and reproducibility. The response of the biosensor to tyramine was linear between 4.9×10?7–6.3×10?5 M with a detection limit of 7.5×10?8 M and sensitivity of 71.36 μA mM?1 (595 μA mM?1 cm?2). The application of the developed biosensor for the determination of tyramine was successfully tested in cheese sample and mean analytical recovery of added tyramine in cheese extract was calculated as 101.2±2.1 %. The presented tyramine biosensor is a promising approach for tyramine analysis in real samples due to its high sensitivity, rapid response and easy fabrication.  相似文献   

18.
We developed a novel iron‐tetrasulfophthalocyanine‐graphene‐Nafion (FeTSPc‐GR‐Nafion) modified screen‐printed electrode to determine hydrogen peroxide (H2O2) with high sensitivity and selectivity. The nanocomposite film (FeTSPc‐GR‐Nafion) exhibits an excellent electrocatalytic activity towards oxidation of H2O2 at a potential of +0.35 V in the absence of enzyme. A comparative study reveals that the FeTSPc‐GR complexes play a dual amplification role. Amperometric experiment indicates that the sensors possess good sensitivity and selectivity, with a linear range from 2.0×10?7 M to 5.0×10?3 M and a detection limit of 8.0×10?8 M. This sensor has been successfully used to develop the glucose biosensor and has also been applied to determine H2O2 in sterile water.  相似文献   

19.
The electrochemical behavior of different redox systems and detection of catechol were performed on the as‐grown boron‐doped diamond (BDD) electrodes and the nanograss array BDD. Compared with as‐grown BDD, the electron transfer on the nanograss array BDD surface became slower toward the negatively charged Fe(CN)63?, whereas changed little toward the positively charged Ru(NH3)63+. The nanograss array BDD showed higher electrocatalytic activity toward the catechol detection than did the as‐grown BDD. Good linearity was observed for a concentration range from 5 to 100 μM with a sensitivity of 719.71 mA M?1 cm?2 and a detection limit of 1.3 μM on the nanograss array BDD.  相似文献   

20.
唐明宇袁若  柴雅琴 《中国化学》2006,24(11):1575-1580
The third generation amperometric biosensor for the determination of hydrogen peroxide (H2O2) has been described. For the fabrication of biosensor, o-aminobenzoic acid (oABA) was first electropolymerized on the surface of platinum (Pt) electrode as an electrostatic repulsion layer to reject interferences. Horseradish peroxidase (HRP) absorbed by nano-scaled particulate gold (nano-Au) was immobilized on the electrode modified with polymerized o-aminobenzoic acid (poABA) with L-cysteine as a linker to prepare a biosensor for the detection of H2O2. Amperometric detection of H2O2 was realized at a potential of +20 mV versus SCE. The resulting biosensor exhibited fast response, excellent reproducibility and sensibility, expanded linear range and low interferences. Temperature and pH dependence and stability of the sensor were investigated. The optimal sensor gave a linear response in the range of 2.99×10^-6 to 3.55×10^-3 mol·L^-1 to H2O2 with a sensibility of 0.0177 A·L^-1·mol^-1 and a detection limit (S/N = 3) of 4.3×10^-7 mol·L^-1. The biosensor demonstrated a 95% response within less than 10 s.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号