首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 956 毫秒
1.
In this work, an easy, effective, and sensitive method based on graphene oxide@silica@magnetite composites as adsorbent of magnetic solid‐phase extraction combined with liquid chromatography and tandem mass spectrometry, was established and validated for the trace analysis of cytokinins in different plants. The prepared magnetic composite was characterized by infrared spectroscopy, transmission electron microscopy, Brunauer–Emmett–Teller analysis, and magnetic hysteresis. Under the optimized conditions, good linearities in the range of 0.5–100 ng/mL were obtained with the corresponding linear correlation coefficient >0.9989 for the investigated four cytokinins, and good sensitivity levels were achieved with low detection limits ranging from 93 to 120 pg/mL. The established magnetic solid‐phase extraction with liquid chromatography and tandem mass spectrometry method has been validated in the separation and analysis of four cytokinins in plant samples with good recoveries between 78.9 and 97.3% for four cytokinins with the relative standard deviations lower than 13.5%.  相似文献   

2.
An aptamer (Apt) functionalized magnetic material was prepared by covalently link Apt to Fe3O4/graphene oxide (Fe3O4/GO) composite by 1‐ethyl‐3‐(3‐dimethylaminopropyl) carbodiimide hydrochloride and N‐hydroxysuccinimide, and then characterized by FTIR spectroscopy, X‐ray diffraction, and vibration sample magnetometry. The obtained composite of Fe3O4/GO/Apt was employed as magnetic solid‐phase extraction adsorbent for the selective preconcentration of sulfadimethoxine prior to analysis by high‐performance liquid chromatography. Under the optimal conditions (sample pH of 4.0, sorbent dosage of 20 mg, extraction time of 3 h, and methanol‐5% acetic acid solution as eluent), a good linear relationship was obtained between the peak area and concentration of sulfadimethoxine in the range of 5.0 to 1500.0 µg/L with correlation coefficient of 0.9997. The limit of detection (S/N = 3) was 3.3 µg/L. The developed method was successfully applied to the analysis of sulfadimethoxine in milk with recoveries in the range of 75.9‐92.3% and relative standard deviations less than 8.1%. The adsorption mechanism of Fe3O4/GO/Apt toward sulfadimethoxine was studied through the adsorption kinetics and adsorption isotherms, and the results show that the adsorption process fits well with the pseudo‐second‐order kinetic model and the adsorbate on Fe3O4/GO/Apt is multilayer and heterogeneous.  相似文献   

3.
The biomonitoring of hydroxy polycyclic aromatic hydrocarbons in urine, as a direct way to access multiple exposures to polycyclic aromatic hydrocarbons, has raised great concerns due to their increasing hazardous health effects on humans. Solid‐phase extraction is an effective and useful technique to preconcentrate trace analytes from biological samples. Here, we report a novel solid‐phase extraction method using a graphene oxide incorporated monolithic syringe for the determination of six hydroxy polycyclic aromatic hydrocarbons in urine coupled with liquid chromatography‐tandem mass spectrometry. The effect of graphene oxide amount, washing solvent, eluting solvent, and its volume on the extraction performance were investigated. The fabricated monoliths gave higher adsorption efficiency and capacity than the neat polymer monolith and commercial C18 sorbent. Under the optimum conditions, the developed method provided the detection limits (S/N = 3) of 0.02–0.1 ng/mL and the linear ranges of 0.1–1500 ng/mL for six analytes in urine sample. The recoveries at three spiked levels ranged from 77.5 to 97.1%. Besides, the intra column‐to‐column (n = 3) and inter batch‐to‐batch (n = 3) precisions were ≤ 9.8%. The developed method was successfully applied for the determination of hydroxy polycyclic aromatic hydrocarbons in urine samples of coke oven workers.  相似文献   

4.
A novel magnetic adsorbent Fe3O4/reduced graphene oxide‐carbon nanotubes, was prepared by one‐pot solvothermal synthesis method. It was characterized by scanning electron microscopy, X‐ray powder diffraction and vibrating sample magnetometry. The diameter of Fe3O4 microparticles was about 350 nm, which were covered by carbon nanotubes and reduced graphene oxide sheets, while carbon nanotubes inserted between the reduced graphene oxide sheets effectively prevented their aggregation. The composite had large surface area and good magnetic property, suiting for magnetic solid‐phase extraction and the determination of sulfonamides, by coupling with high‐performance liquid chromatography. Under the optimized conditions (including extraction time, amount of adsorbent, solution pH, ionic strength and desorption conditions), a good linear was achieved in the concentration range of 5–500 μg/L and the low limits of detection and low limits of quantification were 0.35–1.32 and 1.16–4.40 μg/L, respectively. The enrichment factors were estimated to be 24.72 to 30.15 fold. The proposed method was applied for the detection of sulfonamides in milk sample and the recoveries were 88.4–105.9%, with relative standard deviations of 0.74–5.38%.  相似文献   

5.
In this work, a novel, rapid, and simple analytical method was proposed for the detection of parabens in milk sample by gas chromatography coupled with mass spectrometry. At the same time, milk sample was pretreated by magnetic solid phase extraction, which detected up to five parabens. A series of important parameters of magnetic solid phase extraction were investigated and optimized, such as pH value of loading buffer, amount of material, adsorption time, ionic strength, eluting solvents, and eluting time. Under the optimized conditions, the corresponding values were more than 0.9991, limits of detection and the limit of quantification were 0.1 and 0.5 ng/mL, respectively. In addition, the recoveries were achieved in range of 95–105%, the liner range were within 0.1–600 ng/mL, and the relative standard deviations were even lower than 5%.  相似文献   

6.
In this work, a simple, facile, and sensitive magnetic solid‐phase extraction method was developed for the extraction and enrichment of three representative steroid hormones before high‐performance liquid chromatography analysis. Gold‐modified Fe3O4 nanoparticles, as novel magnetic adsorbents, were prepared by a rapid and environmentally friendly procedure in which polydopamine served as the reductant as well as the stabilizer for the gold nanoparticles, thus successfully avoiding the use of some toxic reagents. To obtain maximum extraction efficiency, several significant factors affecting the preconcentration steps, including the amount of adsorbent, extraction time, pH of the sample solution, and the desorption conditions, were optimized, and the enrichment factors for three steroids were all higher than 90. The validity of the established method was evaluated and good analytical characteristics were obtained. A wide linearity range (0.8–500 μg/L for all the analytes) was attained with good correlation (R2 ≥ 0.991). The low limits of detection were 0.20–0.25 μg/L, and the relative standard deviations ranged from 0.83 to 4.63%, demonstrating a good precision. The proposed method was also successfully applied to the extraction and analysis of steroids in urine, milk, and water samples with satisfactory results, which showed its reliability and feasibility in real sample analysis.  相似文献   

7.
We adopted a facile hydrofluoric acid‐free hydro‐/solvothermal method for the preparation of four magnetic iron(III)‐based framework composites (MIL‐101@Fe3O4‐COOH, MIL‐101‐NH2@Fe3O4‐COOH, MIL‐53@Fe3O4‐COOH, and MIL‐53‐NH2@Fe3O4‐COOH). The obtained four magnetic iron(III)‐based framework composites were applied to magnetic separation and enrichment of the fungicides (prochloraz, myclobutanil, tebuconazole, and iprodione) from environmental samples before high‐performance liquid chromatographic analysis. MIL‐101‐NH2@Fe3O4‐COOH showed more remarkable pre‐concentration ability for the fungicides as compared to the other three magnetic iron(III)‐based framework composites. The extraction parameters affecting enrichment efficiency including extraction time, sample pH, elution time, and the desorption solvent were investigated and optimized. Under the optimized conditions, the standard curve of correlation coefficients were all above 0.991, the limits of detection were 0.04–0.4 μg/L, and the relative standard deviations were below 10.2%. The recoveries of two real water samples ranged from 71.1–99.1% at the low spiking level (30 μg/L). Therefore, the MIL‐101‐NH2@Fe3O4‐COOH composites are attractive for the rapid and efficient extraction of fungicides from environmental water samples.  相似文献   

8.
An orthogonal two‐dimensional solid‐phase extraction strategy was established for the selective enrichment of three aminoglycosides including spectinomycin, streptomycin, and dihydrostreptomycin in milk. A reversed‐phase liquid chromatography material (C18) and a weak cation‐exchange material (TGA) were integrated in a single solid‐phase extraction cartridge. The feasibility of two‐dimensional clean‐up procedure that experienced two‐step adsorption, two‐step rinsing, and two‐step elution was systematically investigated. Based on the orthogonality of reversed‐phase and weak cation‐exchange procedures, the two‐dimensional solid‐phase extraction strategy could minimize the interference from the hydrophobic matrix existing in traditional reversed‐phase solid‐phase extraction. In addition, high ionic strength in the extracts could be effectively removed before the second dimension of weak cation‐exchange solid‐phase extraction. Combined with liquid chromatography and tandem mass spectrometry, the optimized procedure was validated according to the European Union Commission directive 2002/657/EC. A good performance was achieved in terms of linearity, recovery, precision, decision limit, and detection capability in milk. Finally, the optimized two‐dimensional clean‐up procedure incorporated with liquid chromatography and tandem mass spectrometry was successfully applied to the rapid monitoring of aminoglycoside residues in milk.  相似文献   

9.
The determination of 15 pyrethroids in soil and water samples was carried out by gas chromatography with mass spectrometry. Compounds were extracted from the soil samples (4 g) using solid–liquid extraction and then salting‐out assisted liquid–liquid extraction. The acetonitrile phase obtained (0.8 mL) was used as a dispersant solvent, to which 75 μL of chloroform was added as an extractant solvent, submitting the mixture to dispersive liquid–liquid microextraction. For the analysis of water samples (40 mL), magnetic solid‐phase extraction was performed using nanocomposites of magnetic nanoparticles and multiwalled carbon nanotubes as sorbent material (10 mg). The mixture was shaken for 45 min at room temperature before separation with a magnet and desorption with 3 mL of acetone using ultrasounds for 5 min. The solvent was evaporated and reconstituted with 100 μL acetonitrile before injection. Matrix‐matched calibration is recommended for quantification of soil samples, while water samples can be quantified by standards calibration. The limits of detection were in the range of 0.03–0.5 ng/g (soil) and 0.09–0.24 ng/mL (water), depending on the analyte. The analyzed environmental samples did not contain the studied pyrethroids, at least above the corresponding limits of detection.  相似文献   

10.
A new kind of magnetic N‐doped mesoporous carbon was prepared by the one‐step carbonization of a hybrid precursor (glucose, melamine, and iron chloride) in a N2 atmosphere with a eutectic salt (KCl/ZnCl2) as the porogen. The obtained magnetic N‐doped mesoporous carbon showed excellent characteristics, such as strong magnetic response, high surface area, large pore volume, and abundant π‐electron system, which endow it with a great potential as a magnetic solid‐phase extraction adsorbent. To evaluate its adsorption performance, the magnetic N‐doped mesoporous carbon was used for the extraction of three phthalate esters from soft drink samples followed by high‐performance liquid chromatographic analysis. Under the optimum conditions, the developed method showed a good linearity (1.0–120.0 ng/mL), low limit of detection (0.1–0.3 ng/mL, S/N = 3), and good recoveries (83.2–119.0%) in soft drink samples. The results indicated that the magnetic N‐doped mesoporous carbon has an excellent adsorption capacity for phthalate esters and the present method is simple, accurate, and highly efficient for the extraction and determination of phthalate esters in complex matrix samples.  相似文献   

11.
Aminosilanized magnetic carbon microspheres as a novel adsorbent were designed and fabricated. The adsorbent was used for the magnetic solid‐phase extraction of bisphenols at trace levels from environmental water samples before liquid chromatography with tandem mass spectrometry analysis. The structure, surface, and magnetic behavior of the as‐prepared aminosilanized magnetic carbon microspheres were characterized by elemental analysis, scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, powder X‐ray diffraction, and vibrating sample magnetometry. The effects of the experimental parameters were investigated by the Plackett–Burman design, and then the parameters that were significant to the extraction efficiencies were optimized through a response surface methodology. The aminosilanized magnetic carbon microspheres exhibited high adsorption efficiency and selectivity for bisphenols. Under optimal conditions, low limits of detection (0.011–2.22 ng/L), and a wide linear range (2–3 orders of magnitude), good repeatability (4.7–7.8%, n = 5), and reproducibility (6.0–8.3%, n = 3) were achieved. The results demonstrate that the novel adsorbent possesses great potentials in the determination of trace levels of bisphenols in environmental water samples.  相似文献   

12.
Novel ionic‐liquid‐functionalized Fe3O4 magnetic nanoparticles were synthesized by the thiol‐ene click reaction. The prepared functionalized Fe3O4 nanoparticles possessed multiple interactions, such as electrostatic, hydrophobic, and π–π interactions. The functionalized Fe3O4 nanoparticles were characterized by using Fourier transform infrared spectroscopy, X‐ray diffraction, vibrating sample magnetometry, and transmission electron microscopy. Four kinds of linear alkylbenzene sulfonates, namely, sodium decylbenzenesulfonate, sodium undecylbenzene sulfonate, sodium dodecylbenzenesulfonate, and sodium tridecylbenzenesulfonate, were selected as model compounds to evaluate the applicability of adsorbents for extraction and subjected to high‐performance liquid chromatography analysis. In addition, the effects of various parameters, such as sorbent amount, pH value, ionic strength, sample volume, extraction time, and elution conditions on extraction efficiency were studied in detail. Under the optimum conditions, good linearities were attained, with correlation coefficients between 0.9912 and 0.9968. The proposed method exhibited limits of detection ranging from 0.061 to 0.099 μg/L for all the target analytes. The spiked recoveries of the target analytes in real water samples ranged from 86.3 to 107.5%, with relative standard deviations lower than 7.96%. The enrichment factors of the analytes ranged from 364 to 391, indicating that the obtained functionalized Fe3O4 nanoparticles can effectively extract trace target analytes from environmental water samples.  相似文献   

13.
An easy‐to‐handle magnetic dispersive solid‐phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe3O4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high‐performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid‐phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09–1.10 ng/mL. The proposed magnetic dispersive solid‐phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine.  相似文献   

14.
A new method named graphene‐coated magnetic‐sheet solid‐phase extraction based on a magnetic three‐dimensional graphene sorbent was developed for the extraction of aflatoxins prior to high‐performance liquid chromatography with fluorescence detection. The use of a perforated magnetic‐sheet for fixing the magnetic nanoparticles is a new feature of the method. Hence, the adsorbent particles can be separated from sample solution without using an external magnetic field. This made the procedure very simple and easy to operate so that all steps of the extraction process (sample loading, washing, and desorption) were carried out continuously using two lab‐made syringe pumps. The factors affecting the performance of extraction procedure such as the extraction solvent, adsorbent dose, sample loading flow rate, ionic strength, pH, and desorption parameters were investigated and optimized. Under the optimal conditions, the obtained enrichment factors and limits of detection were in the range of 205–236 and 0.09–0.15 μg/kg, respectively. The relative standard deviations were <3.4 and 7.5% for the intraday (= 6) and interday (= 4) precisions, respectively. The developed method was successfully applied to determine aflatoxins B1, B2, G1, and G2 in different soy‐based food samples.  相似文献   

15.
A magnetic polytriphenylamine porous organic polymer was prepared through simple self‐polycondensation of triphenylamine followed by coprecipitation with Fe2+ and Fe3+. It was applied as a magnetic adsorbent for the extraction of six benzoylurea insecticides from tomato, cucumber, and watermelon samples before their high‐performance liquid chromatography and mass spectral detection. Under the optimized experimental conditions, the established method gave a low limit of detection ranging from 0.05 to 0.1 ng/g and a good linear response ranging from 0.2 to 40 ng/g with coefficients of determination >0.99. The method recoveries for spiked analytes at the concentrations of 3 and 15 ng/g in real samples were in the range of 87.7–106.7% with the relative standard deviations <6.4%. The results indicated that it had a good adsorption capability toward the target analytes due to the π‐stacking and hydrogen bonding interactions. The polymer material showed great potential in the efficient extraction of organic compounds from real samples with complex matrixes.  相似文献   

16.
Microcystins (MCs), produced by freshwater cyanobacteria, can be serious water pollutants, so it is important to monitor their concentration in drinking water. We have developed a method for rapid and accurate determination of microcystin levels in environmental water, using magnetic solid‐phase extraction and high‐performance liquid chromatography with UV detection. The magnetic composite material, which was combined with cetylpyridinium chloride, was prepared by hydrothermal synthesis. The optimal extraction of microcystins in water sample was achieved by optimizing the amount of adsorbent, time of adsorption, ratio of eluting solvent, and volume of eluent. Under the optimal conditions, the limit of detection of MC‐LR was 0.001 μg/L, and the limit of quantification was 0.0028 μg/L. The limit of detection of MC‐RR was 0.001 μg/L, and the limit of quantification was 0.003 μg/L. These values are far lower than those established by the International Health Organization for the maximum concentration of microcystins in drinking water. The magnetic solid‐phase extraction adsorbent used in this method has the advantages of simple preparation, low price, and easy solid–liquid separation, and it can be used for the rapid and sensitive monitoring of trace microcystins in environmental water samples.  相似文献   

17.
Magnetic spherical carbon was synthesized by a facile hydrothermal carbonization procedure with biomass glucose as the carbon precursor and nanoclusters iron colloid as magnetic precursor. The textures of the as‐prepared magnetic spherical carbon were characterized by nitrogen adsorption–desorption isotherms, X‐ray diffraction, transmission electron microscopy, scanning electron microscopy and vibration sample magnetometry. Results indicated that the magnetic spherical carbon possessed high surface area as well as strong magnetism, which endows the material with good adsorption capability and easy separation properties. To assess its absorption performance, the magnetic spherical carbon was employed as adsorbent for the extraction and preconcentration of phthalate esters from lake water and milk samples before high‐performance liquid chromatographic analysis. Some key parameters that could influence the enrichment efficiency were investigated. Under the optimum conditions, a good linearity was achieved with the linear correlation coefficients higher than 0.9973. The limits of detection (S/N = 3) were 0.05–0.08 ng/mL for lake water and 0.1–0.2 ng/mL for milk samples. The recoveries of the analytes for the method were in the range 80.1–112.6%.  相似文献   

18.
Graphene oxide has received extensive attention because of its unique properties and potential applications. In this study, magnetic nitrogen‐doped graphene was prepared by one‐step hydrothermal reaction using urea as the dopant and reductant, and ferroferric oxide nanoparticles were in situ deposited on the surface of the nanohybrids. The magnetic nitrogen‐doped graphene was characterized using various physical and chemical methods. It was used as a new adsorbent for the magnetic solid‐phase extraction of four nonsteroidal anti‐inflammatory drugs from the river water. The parameters influencing the extraction efficiency were optimized in detail. Under optimal conditions, this method provided a wide linear range (5–200 ng/mL). The limits of detection were in the range of 1.07–5.10 ng/mL. The recoveries varied from 81.2 to 121.5% with relative standard deviations of less than 10.8%. Overall, we can conclude that the proposed method offers an efficient pretreatment and enrichment and can be successfully applied for the extraction and determination of nonsteroidal anti‐inflammatory drugs in complex matrices.  相似文献   

19.
This work presents a new extraction material, namely, Q‐100, based on hypercrosslinked magnetic particles, which was tested in dispersive solid‐phase extraction for a group of sweeteners from environmental samples. The hypercrosslinked Q‐100 magnetic particles had the advantage of suitable pore size distribution and high surface area, and showed good retention behavior toward sweeteners. Different dispersive solid‐phase extraction parameters such as amount of magnetic particles or extraction time were optimized. Under optimum conditions, Q‐100 showed suitable apparent recovery, ranging in the case of river water sample from 21 to 88% for all the sweeteners, except for alitame (12%). The validated method based on dispersive solid‐phase extraction using Q‐100 followed by liquid chromatography with tandem mass spectrometry provided good linearity and limits of quantification between 0.01 and 0.1 μg/L. The method was applied to analyze samples from river water and effluent wastewater, and four sweeteners (acesulfame, saccharin, cyclamate, and sucralose) were found in both types of sample.  相似文献   

20.
In this work, a method for the analysis of benzoylurea insecticides, including hexaflumuron, flufenoxuron, lufenuron and chlorfluazuron, in tea samples by high‐performance liquid chromatography with Fe3O4‐hyperbranched polyester nanocomposite as the adsorbent for magnetic solid‐phase extraction was developed. The magnetic nanocomposite was prepared and characterized by infrared spectroscopy, vibrating sample magnetometry, and scanning electron microscopy. The as‐prepared nanocomposite was used as a sorbent for the extraction and preconcentration of pesticide residues in tea samples. The extraction and desorption conditions, including mass ratios of raw materials, amount of sorbent, pH value, extraction time, and desorption time, were investigated. Under the final conditions chosen for the analysis, good linearity was obtained for all the tested compounds, with R2 values of at least 0.9979. The limits of detection were determined in the range of 0.15–0.3 μg/L. The recovery obtained from the analysis of tea samples with various spiked concentrations was between 90.7 and 98.4%, with relative standard deviations (n = 4) lower than 4.1%. Furthermore, the present approach was successfully applied to the quantitative determination of residues of benzoylurea insecticides in real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号