首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
A novel infrared‐assisted extraction coupled to headspace solid‐phase microextraction followed by gas chromatography with mass spectrometry method has been developed for the rapid determination of the volatile components in tobacco. The optimal extraction conditions for maximizing the extraction efficiency were as follows: 65 μm polydimethylsiloxane‐divinylbenzene fiber, extraction time of 20 min, infrared power of 175 W, and distance between the infrared lamp and the headspace vial of 2 cm. Under the optimum conditions, 50 components were found to exist in all ten tobacco samples from different geographical origins. Compared with conventional water‐bath heating and nonheating extraction methods, the extraction efficiency of infrared‐assisted extraction was greatly improved. Furthermore, multivariate analysis including principal component analysis, hierarchical cluster analysis, and similarity analysis were performed to evaluate the chemical information of these samples and divided them into three classifications, including rich, moderate, and fresh flavors. The above‐mentioned classification results were consistent with the sensory evaluation, which was pivotal and meaningful for tobacco discrimination. As a simple, fast, cost‐effective, and highly efficient method, the infrared‐assisted extraction coupled to headspace solid‐phase microextraction technique is powerful and promising for distinguishing the geographical origins of the tobacco samples coupled to suitable chemometrics.  相似文献   

2.
An ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction was first employed to determine the volatile components in tobacco samples. The method combined the advantages of ultrasound, microwave, and headspace solid‐phase microextraction. The extraction, separation, and enrichment were performed in a single step, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, several experimental parameters, such as fiber type, ultrasound power, and irradiation time, were optimized to improve sampling efficiency. Under the optimal conditions, there were 37, 36, 34, and 36 components identified in tobacco from Guizhou, Hunan, Yunnan, and Zimbabwe, respectively, including esters, heterocycles, alkanes, ketones, terpenoids, acids, phenols, and alcohols. The compound types were roughly the same while the contents were varied from different origins due to the disparity of their growing conditions, such as soil, water, and climate. In addition, the ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction method was compared with the microwave‐assisted extraction coupled to headspace solid‐phase microextraction and headspace solid‐phase microextraction methods. More types of volatile components were obtained by using the ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction method, moreover, the contents were high. The results indicated that the ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction technique was a simple, time‐saving and highly efficient approach, which was especially suitable for analysis of the volatile components in tobacco.  相似文献   

3.
Headspace solid‐phase microextraction is a solvent‐free sample preparation technique that is based on the equilibrium among a three‐phase system, i.e., sample‐headspace‐fiber. A compromise between sensitivity and extraction time is usually needed to optimize the sample throughput, especially when a large number of samples are analyzed, as usually the case in cross‐samples studies. This work explores the capability of multiple‐cumulative trapping solid‐phase microextraction on the characterization of the aroma profiling of olive oils, exploiting the automation capability of a novel headspace autosampler. It was shown that multiple‐cumulative solid‐phase microextraction has the potential to improve the overall sensitivity and burst the level of information for cross‐sample studies by using cumulative shorter extraction times.  相似文献   

4.
A headspace solid‐phase microextraction (HS‐SPME) method coupled to GC‐MS was developed in order to determine trace levels of tetramethyltin (TeMT) and inorganic tin (iSn) after ethylation to tetraethyltin (TeET) in various matrices. The derivatization of iSn and the extraction of both TeMT and iSn as TeET were performed in one step. Sodium tetraethylborate (NaBEt4) was used as derivatization agent and the volatile derivatives were absorbed on a PDMS‐coated fused silica fiber. The conditions for the HS‐SPME procedure were optimized in order to gain in repeatability and sensitivity. Several critical parameters of GC‐MS were also studied. The detection of TeMT and iSn as TeET peaks was performed by the SIM mode. The precision of the proposed method is satisfactory providing RSD values below 10% for both tin species and good linearity up to 10 μg/L. The developed method was successfully applied to the determination of tin species in several samples like canned fish, fish tissues, aquatic plants, canned mineral water and sea water. The proposed HS‐SPME‐GC‐MS method was proved suitable to monitor the concentration levels of toxic tin compounds in environmental and biological samples.  相似文献   

5.
In this study, an effective speed‐regulated directly suspended droplet microextraction method was developed to condense pesticide residues from teas through dispersive solid‐phase extraction prior to analysis by gas chromatography with tandem mass spectrometry. The extractant was intentionally dispersed into the sample solution in the form of globules through high‐speed agitation. This procedure increases the contact area between the binary phases and shortens the distribution equilibrium time. The fine globules reassembled by decelerating stirring speed, the extractant could be taken out for gas chromatography with tandem mass spectrometry. Recovery studies were performed under optimized extraction conditions by using matrix blanks fortified with pesticides at three concentrations (10, 50, and 100 µg/kg). Over 87% of the recoveries for the analytes in four tea matrices were acceptable given their recovery ranges of 70–120% and relative standard deviations of ≤20%. The limits of quantification of most pesticides were lower than 10 µg/kg and thus satisfied the requirements for maximum residue levels prescribed by the European Community. A total of 38 tea samples from local markets were analyzed by using the proposed method. Results showed that chlorpyrifos was the most frequently detected pesticide in teas. The method is a potential choice for the routine monitoring of pesticide residues in complex matrices.  相似文献   

6.
A two‐phase electromembrane extraction (EME) was developed and directly coupled with gas chromatography mass spectrometry (GC‐MS) analysis. The proposed method was successfully applied to the simultaneous determination of imipramine, desipramine, citalopram and sertraline. The model compounds were extracted from neutral aqueous sample solutions into the organic phase filled in the lumen of the hollow fiber. This method was accomplished with 1‐heptanol as organic phase, by means of 60 V applied voltage and with the extraction time of 15 min. Experiments reported recoveries in the range of 69–87% from 1.2 mL neutral sample solution. The compounds were quantified by GC‐MS instrument, with acceptable linearity ranging from 1 to 500 ng mL?1 (R2 in the range of 0.989 to 0.998), and repeatability (RSD) ranging between 7.5 and 11.5% (n = 5). The estimated detection limits (S/N ratio of 3:1) were less than 0.25 ng mL?1. This novel approach based on two‐phase EME brought advantages such as simplicity, low‐costing, low detection limit and fast extraction with a total analysis time less than 25 min. These experimental findings were highly interesting and demonstrated the possibility of solving ionic species in the organic phase at the presence of electrical potential.  相似文献   

7.
A novel, ecofriendly, and easy extraction and preconcentration method named as vortex‐assisted spraying‐based fine droplet formation liquid‐phase microextraction was proposed for the determination of prochloraz at trace levels in orange juice samples by gas chromatography–mass spectrometry (GC‐MS). In this novel system, extraction solvent is dispersed by the help of spraying apparatus instead of dispersive solvent. Various parameters of the method were carefully optimized to increase signal‐to‐noise ratio of the analyte. Under the optimum chromatographic and extraction conditions, limit of detection and limit of quantification were calculated as 3.2 and 10.8 μg/kg, respectively. Moreover, enhancement in quantification power for the GC‐MS system was determined as 372 folds based on LOQ comparison. Relative recovery results for orange juice samples were found to be between 95.0–107.7% by utilizing matrix matching calibration. Furthermore, the developed method may be used to efficiently and simply extract other organic compounds for their determinations in several matrices.  相似文献   

8.
A GC‐MS procedure for simultaneously determining and validating kresoxim‐methyl and boscalid has been developed in fruit, vegetable and soil matrices. The method was based on one‐step liquid–liquid extraction with acetone and dichloromethane solvents. Estimated limits of detection (LODs) for kresoxim‐methyl and boscalid were 0.006 and 0.015 mg/kg, and limits of quantification (LOQs) were 0.02 and 0.05 mg/kg, respectively. The intra‐ and inter‐ precision were achieved with RSD better than 13.8 and 14.5%, and recoveries were in the range of 77.1–98.7% for kresoxim‐methyl and 72.8–105.1% for boscalid. The expanded uncertainties calculated at 0.1 mg/kg were below 18%. Concentration levels for residues of the two fungicides in melon samples from field trials collected 7 days after the last application were clearly below the established MRL values. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
The determination of 15 pyrethroids in soil and water samples was carried out by gas chromatography with mass spectrometry. Compounds were extracted from the soil samples (4 g) using solid–liquid extraction and then salting‐out assisted liquid–liquid extraction. The acetonitrile phase obtained (0.8 mL) was used as a dispersant solvent, to which 75 μL of chloroform was added as an extractant solvent, submitting the mixture to dispersive liquid–liquid microextraction. For the analysis of water samples (40 mL), magnetic solid‐phase extraction was performed using nanocomposites of magnetic nanoparticles and multiwalled carbon nanotubes as sorbent material (10 mg). The mixture was shaken for 45 min at room temperature before separation with a magnet and desorption with 3 mL of acetone using ultrasounds for 5 min. The solvent was evaporated and reconstituted with 100 μL acetonitrile before injection. Matrix‐matched calibration is recommended for quantification of soil samples, while water samples can be quantified by standards calibration. The limits of detection were in the range of 0.03–0.5 ng/g (soil) and 0.09–0.24 ng/mL (water), depending on the analyte. The analyzed environmental samples did not contain the studied pyrethroids, at least above the corresponding limits of detection.  相似文献   

10.
In this paper, solid‐phase extraction (SPE) in combination with dispersive liquid–liquid microextraction (DLLME) has been developed as a sample pretreatment method with high enrichment factors for the sensitive determination of amide herbicides in water samples. In SPE–DLLME, amide herbicides were adsorbed quantitatively from a large volume of aqueous samples (100 mL) onto a multiwalled carbon nanotube adsorbent (100 mg). After elution of the target compounds from the adsorbent with acetone, the DLLME technique was performed on the resulting solution. Finally, the analytes in the extraction solvent were determined by gas chromatography–mass spectrometry. Some important extraction parameters, such as flow rate of sample, breakthrough volume, sample pH, type and volume of the elution solvent, as well as salt addition, were studied and optimized in detail. Under optimum conditions, high enrichment factors ranging from 6593 to 7873 were achieved in less than 10 min. There was linearity over the range of 0.01–10 μg/L with relative standard deviations of 2.6–8.7%. The limits of detection ranged from 0.002 to 0.006 μg/L. The proposed method was used for the analysis of water samples, and satisfactory results were achieved.  相似文献   

11.
Pesticides, widely applied in agriculture, can produce a variety of transformation products and their continuous use causes deleterious effects to ecosystem. Efficient and sensitive analytical techniques for enrichment and analysis of pesticides samples are highly required. Compared with other extraction methods, solid‐phase micro extraction is a solvent free, cost effective, robust, versatile, and high throughput sample preparation technique, especially for the analysis of pesticides from complicated matrices. Coupling of solid‐phase micro extraction with gas chromatography and mass spectrometry and liquid chromatography–mass spectrometry has been extensively applied in pesticide analysis. On the other hand, in recent years, combination of fast separation using solid‐phase micro extraction and rapid detection using ambient mass spectrometry is providing highly efficient pesticide screening. This article summarizes the applications of solid‐phase micro extraction coupled to mass spectrometry for pesticides analysis.  相似文献   

12.
A solid‐phase extraction combined with a liquid chromatography‐tandem mass spectrometry analysis has been developed and validated for the simultaneous determination of 44 pharmaceuticals belonging to different therapeutic classes (i.e., antibiotics, anti‐inflammatories, cardiovascular agents, hormones, neuroleptics, and anxiolytics) in water samples. The sample preparation was optimized by studying target compounds retrieval after the following processes: i) water filtration, ii) solid phase extraction using Waters Oasis HLB cartridges at various pH, and iii) several evaporation techniques. The method was then validated by the analysis of spiked estuarine waters and wastewaters before and after treatment. Analytical performances were evaluated in terms of linearity, accuracy, precision, detection, and quantification limits. Recoveries of the pharmaceuticals were acceptable, instrumental detection limits varied between 0.001 and 25 pg injected and method quantification limits ranged from 0.01 to 30.3 ng/L. The precision of the method, calculated as relative standard deviation, ranged from 0.3 to 49.4%. This procedure has been successfully applied to the determination of the target analytes in estuarine waters and wastewaters. Eight of these 44 pharmaceuticals were detected in estuarine water, while 26 of them were detected in wastewater effluent. As expected, the highest values of occurrence and concentration were found in wastewater influent.  相似文献   

13.
Antihistamines are excreted into breast milk in small amounts; however, there are no adequate published studies or data concerning their effects on newborns and safety during breastfeeding. Thus, the development of sensitive and specific methodologies for the determination of antihistamines in breast milk is critical. A simple and sensitive GC–MS method for the simultaneous determination of 11 antihistamines (diphenhydramine, orphenadrine, chlorpheniramine, dimethindene, meclozine, hydroxyzine, loratadine, desloratadine, cetirizine, rupatadine and ebastine) in breast milk was developed and validated. The antihistamines were solid‐phase extracted and derivatized with acetic anhydride and n‐propanol. Diazepam‐d5, hydroxyzine‐d4 and cetirizine‐d8 were used as internal standards. Absolute recovery values for all analytes ranged from 70.5 to 120.0%, while the limits of detection and quantification for all analytes were 1.50 and 5.00 ng/mL, respectively. All calibration curves were linear (R2 ≥ 0.990) within the range 5.00–1000.0 ng/mL. Accuracy (Er) ranged between −7.6 and 7.0%, while precision (RSD) was <12% for all antihistamines. The developed method is suitable for the investigation of antihistamine‐related clinical cases, as well as for pharmacokinetic and breastfeeding safety studies.  相似文献   

14.
To date, the commonly used intravenous anesthetic propofol has been widely studied, and fundamental pharmacodynamic and pharmacokinetic characteristics of the drug are known. However, propofol has not yet been quantified in vivo in the target organ, the human brain. Here, cerebral microdialysis offers the unique opportunity to sample propofol in the living human organism. Therefore, a highly sensitive analytical method for propofol quantitation in small sample volumes of 30 μL, based on direct immersion solid‐phase microextraction was developed. Preconcentration was followed by gas chromatographic separation and mass spectrometric detection of the compound. This optimized method provided a linear range between the lower limit of detection (50 ng/L) and 200 μg/L. Matrix‐matched calibration was used to compensate recovery issues. A precision of 2.7% relative standard deviation between five consecutive measurements and an interday precision of 6.4% relative standard deviation could be achieved. Furthermore, the permeability of propofol through a cerebral microdialysate system was tested. In summary, the developed method to analyze cerebral microdialysate samples, allows the in vivo quantitation of propofol in the living human brain. Additionally the calculation of extracellular fluid levels is enabled since the recovery of the cerebral microdialysis regarding propofol was determined.  相似文献   

15.
建立了顶空固相微萃取-气相色谱-串联质谱测定水中戊二醛的方法。设计5因素4水平完整的正交试验,通过极差分析获得顶空固相微萃取优化条件。10 mL,pH 1的水样加入6 g NaCl,经非极性PDM S,100μm纤维头于75℃萃取25 min,210℃解析进样0.2 min。采用VF-5(60 m×0.25 mm×0.25μm)色谱柱程序升温分离,选择多反应监测(M RM)模式采集质谱信息。以m/z 82/54为定量离子,以m/z 82/39为定性离子,外标法定量。结果表明,戊二醛质量浓度在0.02~0.6 mg/L范围内线性良好,相关系数(r)>0.9996,方法检出限7μg/L,定量限20μg/L。低(0.04 mg/L)、中(0.1 mg/L)、高(0.4 mg/L)3个水平加标回收率为87.4%~103.7%,相对标准偏差(RSD)<6%。方法适用于测定水中的戊二醛。  相似文献   

16.
A new facile magnetic micro‐solid‐phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite‐MCM‐41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite‐MCM‐41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05–500 μg/L (r 2 = 0.996–0.999). Good limits of detection (0.008–0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n  = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1–115.4%. Results indicate that magnetite micro‐solid‐phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples.  相似文献   

17.
Headspace solid‐phase microextraction coupled with cryotrap gas chromatography and mass spectrometry was applied to the analysis of volatile organic compounds in pleural effusions. The highly volatile organic compounds were separated successfully with high sensitivity by the employment of a cryotrap device, with the construction of a cold column head by freezing a segment of metal capillary with liquid nitrogen. A total of 76 volatile organic compounds were identified in 50 pleural effusion samples (20 malignant effusions and 30 benign effusions). Among them, 34 more volatile organic compounds were detected with the retention time less than 8 min, by comparing with the normal headspace solid‐phase microextraction coupled with gas chromatography and mass spectrometry method. Furthermore, 24 volatile organic compounds with high occurrence frequency in pleural effusion samples, 18 of which with the retention time less than 8 min, were selected for the comparative analysis. The results of average peak area comparison and box‐plot analysis showed that except for cyclohexanone, 2‐ethyl‐1‐hexanol, and tetramethylbenzene, which have been reported as potential cancer biomarkers, cyclohexanol, dichloromethane, ethyl acetate, n‐heptane, ethylbenzene, and xylene also had differential expression between malignant and benign effusions. Therefore, the proposed approach was valuable for the comprehensive characterization of volatile organic compounds in pleural effusions.  相似文献   

18.
Through the use of a homemade sol–gel‐derived fiber, a headspace solid‐phase microextraction technique coupled to gas chromatography with mass spectrometry was developed for the determination of fatty acids with long, even‐numbered carbon chains (C12–C24) in soil samples. The experimental parameters such as reaction time, temperature, and ionic strength that might affect derivatization, extraction, and desorption were investigated. Under the optimized conditions, the linearity of the method ranged from 0.1 to 100 mg/L with a correlation coefficient >0.997. The limit of detection values based on a signal‐to‐noise ratio of 3:1 were determined with the concentration from 0.39 to 39.4 μg/L. The recoveries of the method for the soil samples were from 91.15 to 108.1%. This developed method using a homemade fiber showed a higher sensitivity than that using a commercial polydimethylsiloxane fiber and was also for the analysis of real soil samples from the Paomaling geological park of China.  相似文献   

19.
A number of fatty acid ethyl esters (FAEEs) have recently been detected in meconium samples. Several of these FAEEs have been evaluated as possible biomarkers for in utero ethanol exposure. In the present study, a method was optimized and validated for the simultaneous determination of eight FAEEs (ethyl laurate, ethyl myristate, ethyl palmitate, ethyl palmitoleate, ethyl stearate, ethyl oleate, ethyl linoleate and ethyl arachidonate) in meconium samples. FAEEs were extracted by headspace solid‐phase microextraction. Analyte detection and quantification were carried out using GC‐MS operated in chemical ionization mode. The corresponding D5‐ethyl esters were synthesized and used as internal standards. The LOQ and LOD for each analyte were <150 and <100 ng/g, respectively. The method showed good linearity (r2>0.98) in the concentration range studied (LOQ – 2000 ng/g). The intra‐ and interday imprecision, given by the RSD of the method, was lower than 15% for all FAEEs studied. The validated method was applied to 63 authentic specimens. FAEEs could be detected in alcohol‐exposed newborns (>600 ng/g cumulative concentration). Interestingly, FAEEs could also be detected in some non‐exposed newborns, although the concentrations were much lower than those measured in exposed cases.  相似文献   

20.
A method combining accelerated solvent extraction with dispersive liquid–liquid microextraction was developed for the first time as a sample pretreatment for the rapid analysis of phenols (including phenol, m‐cresol, 2,4‐dichlorophenol, and 2,4,6‐trichlorophenol) in soil samples. In the accelerated solvent extraction procedure, water was used as an extraction solvent, and phenols were extracted from soil samples into water. The dispersive liquid–liquid microextraction technique was then performed on the obtained aqueous solution. Important accelerated solvent extraction and dispersive liquid–liquid microextraction parameters were investigated and optimized. Under optimized conditions, the new method provided wide linearity (6.1–3080 ng/g), low limits of detection (0.06–1.83 ng/g), and excellent reproducibility (<10%) for phenols. Four real soil samples were analyzed by the proposed method to assess its applicability. Experimental results showed that the soil samples were free of our target compounds, and average recoveries were in the range of 87.9–110%. These findings indicate that accelerated solvent extraction with dispersive liquid–liquid microextraction as a sample pretreatment procedure coupled with gas chromatography and mass spectrometry is an excellent method for the rapid analysis of trace levels of phenols in environmental soil samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号