首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A rapid dispersive micro‐solid phase extraction (D‐μ‐SPE) combined with LC/MS/MS method was developed and validated for the determination of ketoconazole and voriconazole in human urine and plasma samples. Synthesized mesoporous silica MCM‐41 was used as sorbent in d ‐μ‐SPE of the azole compounds from biological fluids. Important D‐μ‐SPE parameters, namely type desorption solvent, extraction time, sample pH, salt addition, desorption time, amount of sorbent and sample volume were optimized. Liquid chromatographic separations were carried out on a Zorbax SB‐C18 column (2.1 × 100 mm, 3.5 μm), using a mobile phase of acetonitrile–0.05% formic acid in 5 mm ammonium acetate buffer (70:30, v /v). A triple quadrupole mass spectrometer with positive ionization mode was used for the determination of target analytes. Under the optimized conditions, the calibration curves showed good linearity in the range of 0.1–10,000 μg/L with satisfactory limit of detection (≤0.06 μg/L) and limit of quantitation (≤0.3 μg/L). The proposed method also showed acceptable intra‐ and inter‐day precisions for ketoconazole and voriconazole from urine and human plasma with RSD ≤16.5% and good relative recoveries in the range 84.3–114.8%. The MCM‐41‐D‐μ‐SPE method proved to be rapid and simple and requires a small volume of organic solvent (200 μL); thus it is advantageous for routine drug analysis.  相似文献   

2.
In this work, an ampholine‐functionalized hybrid organic–inorganic silica sorbent was successfully used to extract melamine from a milk formula sample by a hydrophilic interaction solid‐phase extraction protocol. Primary factors affecting the extraction efficiency of the material such as extraction solvent, elution solvent, sample loading volume, and elution volume have been thoroughly optimized. Under the optimized hydrophilic solid‐phase extraction conditions, the recoveries of melamine spiked in milk formula samples ranged from 86.2 to 101.8% with relative standard deviations of 4.1–9.4% (n = 3). The limit of detection (S/N = 3) was 0.32 μg/g. The adsorption capacity toward melamine was 30 μg of melamine per grams of sorbent. Due to its simplicity, rapidity and cost effectiveness, the newly developed hydrophilic solid‐phase extraction method should provide a promising tool for daily monitoring of doped melamine in milk formula.  相似文献   

3.
This work is the first study on the extraction efficiency of self‐doped polyaniline that is immobilized on the graphene‐modified magnetic nanoparticles. The new material was used as a sorbent for the magnetic solid‐phase extraction of methyl‐, propyl‐, and butylparabens. The use of graphene provides a high surface area and prevents aggregation of the nanoparticles. The self‐doped polyaniline also provides multifunctionality, high extraction capacity, and chemical stability even in the basic medium. The parabens were acetylated for determination by gas chromatography with flame ionization detection. The effects of monomer ratio, extraction solvent, sorbent amount, sample volume, desorption solvent volume, adsorption and desorption times, and sample ionic strength were optimized. Preconcentration factors obtained were from 190 to 310. The detection limits of the method were <2.8 μg/L. Linear ranges of the method were 5–2000 μg/L for propyl and butyl parabens, and 10–2000 μg/L for methyl paraben. The method was applied for the determination of the parabens in cosmetic products and extraction recoveries were 89–101% with RSDs ≤7.9%.  相似文献   

4.
A new facile magnetic micro‐solid‐phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite‐MCM‐41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite‐MCM‐41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05–500 μg/L (r 2 = 0.996–0.999). Good limits of detection (0.008–0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n  = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1–115.4%. Results indicate that magnetite micro‐solid‐phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples.  相似文献   

5.
In this article, the use of magnetically separable sorbent polyaniline/silica‐coated nickel nanoparticles is evaluated under a dispersive micro‐solid‐phase extraction approach for the extraction of phenolic compounds from water samples. The sorbent was prepared by in situ chemical polymerization of aniline on the surface of silica‐modified nickel nanoparticles and was characterized by Fourier transform infrared spectroscopy, transmission electron microscopy, X‐ray powder diffraction, scanning electron microscopy, energy‐dispersive X‐ray spectrometry, and vibrating sample magnetometry. Effective variables such as amount of sorbent (milligrams), pH and ionic strength of sample solution, volume of eluent solvent (microliters), vortex, and ultrasonic times (minutes) were investigated by fractional factorial design. The significant variables optimized by a Box–Behnken design were combined by a desirability function. Under the optimized conditions, the calibration graphs of analytes were linear in a concentration range of 0.02–100 μg/mL, and with correlation coefficients more than 0.999. The limits of detection and quantification were in the ranges of 10–23 and 33–77 μg/L, respectively. This procedure was successfully employed in the determination of target analytes in spiked water samples; the relative mean recoveries ranged from 96 to 105%.  相似文献   

6.
A new mesoporous silica based on the sol–gel material cyanopropyltriethoxysilane (CNPrTEOS) was successfully synthesized by the hydrolysis and condensation of CNPrTEOS in the presence of ammonium solution as catalyst and methanol as solvent. It was used as a solid‐phase extraction sorbent for the simultaneous extraction of three organophosphorus pesticides, namely, polar dicrotophos and non‐polar diazinon and chlorpyrifos. Analysis was performed using high‐performance liquid chromatography with UV detection. CNPrTEOS was characterized by FTIR spectroscopy, field‐emission scanning electron microscopy and nitrogen gas adsorption. The surface area and average pore diameter of the optimum sol–gel CNPrTEOS are 379 m2/g and 4.7 nm (mesoporous), respectively. The proposed solid‐phase extraction based on CNPrTEOS exhibited good linearity in the range of 0.8–100 μg/L, satisfactory precision (1.15–3.82%), high enrichment factor (800) and low limit of detection (0.072–0.091 μg/L). The limits of detection obtained using the proposed solid‐phase extraction method are well below the maximum residue limit set by European Union and are also lower (13.6–48.5×) than that obtained by using a commercial CN‐SPE cartridge (0.98–4.41 μg/L). The new mesoporous sol–gel CNPrTEOS showed promising alternative as SPE sorbent material for the simultaneous extraction of polar and non‐polar organophosphorus pesticides.  相似文献   

7.
A new kind of magnetic N‐doped mesoporous carbon was prepared by the one‐step carbonization of a hybrid precursor (glucose, melamine, and iron chloride) in a N2 atmosphere with a eutectic salt (KCl/ZnCl2) as the porogen. The obtained magnetic N‐doped mesoporous carbon showed excellent characteristics, such as strong magnetic response, high surface area, large pore volume, and abundant π‐electron system, which endow it with a great potential as a magnetic solid‐phase extraction adsorbent. To evaluate its adsorption performance, the magnetic N‐doped mesoporous carbon was used for the extraction of three phthalate esters from soft drink samples followed by high‐performance liquid chromatographic analysis. Under the optimum conditions, the developed method showed a good linearity (1.0–120.0 ng/mL), low limit of detection (0.1–0.3 ng/mL, S/N = 3), and good recoveries (83.2–119.0%) in soft drink samples. The results indicated that the magnetic N‐doped mesoporous carbon has an excellent adsorption capacity for phthalate esters and the present method is simple, accurate, and highly efficient for the extraction and determination of phthalate esters in complex matrix samples.  相似文献   

8.
In this study, a simple effervescence‐assisted dispersive solid‐phase extraction method was developed to detect fungicides in honey and juice. Most significantly, an innovative ionic‐liquid‐modified magnetic β‐cyclodextrin/attapulgite sorbent was used because its large specific surface area enhanced the extraction capacity and also led to facile separation. A one‐factor‐at‐a‐time approach and orthogonal design were employed to optimize the experimental parameters. Under the optimized conditions, the entire extraction procedure was completed within 3 min. In addition, the calibration curves exhibited good linearity, and high enrichment factors were achieved for pure water and honey samples. For the honey samples, the extraction efficiencies for the target fungicides ranged from 77.0 to 94.3% with relative standard deviations of 2.3–5.44%. The detection and quantitation limits were in the ranges of 0.07–0.38 and 0.23–1.27 μg/L, respectively. Finally, the developed technique was successfully applied to real samples, and satisfactory results were achieved. This analytical technique is cost‐effective, environmentally friendly, and time‐saving.  相似文献   

9.
We report on the fabrication of a thin‐film composite for the extraction of bisphenol A from aqueous solutions. Nylon‐6, C18 particles, and polyethylene glycol were used to prepare the thin film sorbent. Bisphenol A was used as a model compound to evaluate the extraction efficiency of the sorbent. High‐performance liquid chromatography with UV detection was used for the analysis. The extraction yield of the sorbent was compared with other thin films fabricated using different sorbents including nanoclay, LiChrolut EN, and multiwalled carbon nanotubes. Experimental parameters affecting the extraction performance (extraction time, desorption condition, sample stirring, and ionic strength of the sample solution) were investigated. The detection limit and the dynamic range of the method were 0.05 and 0.15–50 μg/L, respectively. The relative standard deviation of the method at two concentration levels (0.5 and 20 μg/L) was less than 7.2%. Finally, a polycarbonate baby bottle, river water, and wastewater samples were analyzed by the method.  相似文献   

10.
A graphene oxide reinforced polymeric ionic liquids monolith was obtained by copolymerization of graphene oxide doped 1‐(3‐aminopropyl)‐3‐(4‐vinylbenzyl)imidazolium 4‐styrenesulfonate monomer and 1,6‐di‐(3‐vinylimidazolium) hexane bihexafluorophosphate cross‐linking agent. Coupled to high‐performance liquid chromatography, the monolith was used as a solid‐phase microextraction sorbent to analyze several phenolic compounds in aqueous samples. Under the optimized extraction and desorption conditions, linear ranges were 5–400 μg/L for 3‐nitrophenol, 2‐nitrophenol, and 2,5‐dichlorophenol and 2–400 μg/L for 4‐chlorophenol, 2‐methylphenol, and 2,4,6‐trichlorophenol (R2 = 0.9973–0.9988). The limits of detection were 0.5 μg/L for 3‐nitrophenol and 2‐nitrophenol and 0.2 μg/L for the rest of the analytes. The proposed method was used to determine target analytes in groundwater from an industrial park and river water. None of the analytes was detected. Relative recoveries were in the range of 75.5–113%.  相似文献   

11.
A high‐performance liquid chromatographic (HPLC) method with integrated solid‐phase extraction for the determination of 1‐hydroxypyrene and 1‐, 2‐, 3‐, 4‐ and 9‐hydroxyphenanthrene in urine was developed and validated. After enzymatic treatment and centrifugation of 500 μL urine, 100 μL of the sample was directly injected into the HPLC system. Integrated solid‐phase extraction was performed on a selective, copper phthalocyanine modified packing material. Subsequent chromatographic separation was achieved on a pentafluorophenyl core–shell column using a methanol gradient. For quantification, time‐programmed fluorescence detection was used. Matrix‐dependent recoveries were between 94.8 and 102.4%, repeatability and reproducibility ranged from 2.2 to 17.9% and detection limits lay between 2.6 and 13.6 ng/L urine. A set of 16 samples from normally exposed adults was analyzed using this HPLC‐fluorescence detection method. Results were comparable with those reported in other studies. The chromatographic separation of the method was transferred to an ultra‐high‐performance liquid chromatography pentafluorophenyl core–shell column and coupled to a high‐resolution time‐of‐flight mass spectrometer (HR‐TOF‐MS). The resulting method was used to demonstrate the applicability of LC‐HR‐TOF‐MS for simultaneous target and suspect screening of monohydroxylated polycyclic aromatic hydrocarbons in extracts of urine and particulate matter.  相似文献   

12.
A novel, simple, and rapid vortex‐assisted hollow‐fiber liquid‐phase microextraction method was developed for the simultaneous extraction of albendazole and triclabendazole from various matrices before their determination by high‐performance liquid chromatography with fluorescence detection. Several factors influencing the microextraction efficiency including sample pH, nature and volume of extraction solvent, ionic strength, vortex time, and sample volume were investigated and optimized. Under the optimal conditions, the limits of detection were 0.08 and 0.12 μg/L for albendazole and triclabendazole, respectively. The calibration curves were linear in the concentration ranges of 0.3–50.0 and 0.4–50.0 μg/L with the coefficients of determination of 0.9999 and 0.9995 for albendazole and triclabendazole, respectively. The interday and intraday relative standard deviations for albendazole and triclabendazole at three concentration levels (1.0, 10.0, and 30.0 μg/L) were in the range of 6.0–11.0 and 5.0–7.9%, respectively. The developed method was successfully applied to determine albendazole and triclabendazole in water, milk, honey, and urine samples.  相似文献   

13.
The approach of this work was to study the capability of graphene‐based materials in the field of biological sample preparation. A polypyrrole/graphene composite was synthesized and characterized. The potential of the nanocomposite was investigated as a sorbent in dispersive solid‐phase extraction followed by high‐performance liquid chromatography with UV detection for vancomycin as a model drug. The effect of different parameters influencing extraction efficiency such as sample pH and sample volume, ionic strength, extraction time, type, and volume of desorption solvent and desorption time were investigated. A comparison study was also conducted between polypyrrole/graphene and some different novel and classic sorbents. Under optimized conditions, the calibration curve for vancomycin showed linearity in the range of 0.05–10 μg/mL. In addition, limits of detection, and quantification were 0.003 and 0.01 μg/mL, respectively. The intraday and interday relative standard deviations at a concentration of 0.05 μg/mL (n = 3) were 1.6 and 2.1%, respectively. Furthermore, the proposed method was successfully applied for the determination of vancomycin in plasma and urine samples. The relative recoveries indicated the feasibility of graphene‐based sorbents in biological sample analysis.  相似文献   

14.
In this work, an efficient sample preparation method termed solvent‐assisted dispersive solid‐phase extraction was applied. The used sample preparation method was based on the dispersion of the sorbent (benzophenone) into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was achieved by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre‐concentration of the butachlor, the cloudy solution was centrifuged and butachlor in the sediment phase dissolved in ethanol and determined by gas chromatography with flame ionization detection. Under the optimized conditions (solution pH = 7.0, sorbent: benzophenone, 2%, disperser solvent: ethanol, 500 μL, centrifuged at 4000 rpm for 3 min), the method detection limit for butachlor was 2, 3 and 3 μg/L for distilled water, waste water, and urine sample, respectively. Furthermore, the preconcentration factor was 198.8, 175.0, and 174.2 in distilled water, waste water, and urine sample, respectively. Solvent‐assisted dispersive solid‐phase extraction was successfully used for the trace monitoring of butachlor in urine and waste water samples.  相似文献   

15.
In the present study, highly efficient and simple dispersive solid‐phase extraction procedure for the determination of haloacetic acids in water samples has been established. Three different types of layered double hydroxides were synthesized and used as a sorbent in dispersive solid‐phase extraction. Due to the interesting behavior of layered double hydroxides in an acidic medium (pH?4), the analyte elution step was not needed; the layered double hydroxides are simply dissolved in acid immediately after extraction to release the analytes which are then directly introduced into a liquid chromatography with tandem mass spectrometry system for analysis. Several dispersive solid‐phase extraction parameters were optimized to increase the extraction efficiency of haloacetic acids such as temperature, extraction time and pH. Under optimum conditions, good linearity was achieved over the concentration range of 0.05–100 μg/L with detection limits in the range of 0.006–0.05 μg/L. The relative standard deviations were 0.33–3.64% (n = 6). The proposed method was applied to different water samples collected from a drinking water plant to determine the concentrations of haloacetic acids.  相似文献   

16.
A novel magnetic mesoporous silica material was synthesized and used as the sorbent for the magnetic solid‐phase microextraction of diazinon and malathion before their quantification by high‐performance liquid chromatography with UV detection. The sorbent was synthesized by a surfactant‐templated one‐pot sol–gel procedure using SiO2‐coated Fe3O4 as the magnetic support, cetyltrimethylammonium bromide as the template and tetraethyl orthosilicate as the silicon source. The characteristics of the prepared sorbent were investigated using Fourier transform infrared spectroscopy, scanning electron microscopy, and X‐ray diffraction. The sorbent exhibited a high maximum adsorption capacity of 19.2 and 9.4 mg/g for diazinon and malathion, respectively. The parameters affecting the microextraction were optimized by the MultiSimplex method. Under the optimized conditions, the calibration graphs were linear in the concentration ranges of 0.3–50.0 and 0.5–50 μg/L with the limits of detection of 0.09 and 0.14 μg/L for diazinon and malathion, respectively. The relative standard deviations (n = 5) at a concentration level of 10.0 μg/L of analytes were less than 2.5 and 4% for intra and interday, respectively. The developed method was successfully used for the determination of diazinon and malathion in apple, tomato, cucumber, tap water, and well water samples.  相似文献   

17.
Monoamine acidic metabolites in biological samples are essential biomarkers for the diagnosis of neurological disorders. In this work, acrylamide‐functionalized graphene adsorbent was successfully synthesized by a chemical functionalization method and was packed in a homemade polyether ether ketone micro column as a micro‐solid‐phase extraction unit. This micro‐solid‐phase extraction unit was directly coupled to high‐performance liquid chromatography to form an online system for the separation and analysis of three monoamine acidic metabolites including homovanillic acid, 5‐hydroxyindole‐3‐acetic acid, and 3,4‐dihydroxyphenylacetic acid in human urine and plasma. The online system showed high stability, permeability, and adsorption capacity toward target metabolites. The saturated extraction amount of this online system was 213.1, 107.0, and 153.4 ng for homovanillic acid, 5‐hydroxyindole‐3‐acetic acid, and 3,4‐dihydroxyphenylacetic acid, respectively. Excellent detection limits were achieved in the range of 0.08–0.25 μg/L with good linearity and reproducibility. It was interesting that three targets in urine and plasma could be actually quantified to be 0.94–3.93 μg/L in plasma and 7.15–19.38 μg/L in urine. Good recoveries were achieved as 84.8–101.4% for urine and 77.8–95.1% for plasma with the intra‐ and interday relative standard deviations less than 9.3 and 10.3%, respectively. This method shows great potential for online analysis of trace monoamine acidic metabolites in biological samples.  相似文献   

18.
In this study, organic aerogels were synthesized by the sol–gel polycondensation of mixed cresol with formaldehyde in a slightly basic aqueous solution. Carbon aerogels and xerogels are generated by pyrolysis of organic aerogels. The novel sol–gel‐based micro‐solid‐phase extraction sorbent, resorcinol–formaldehyde xerogel, was employed for preconcentration of some selected herbicides. Three herbicides of the aryloxyphenoxypropionate group, clodinafop‐propargyl, haloxyfop‐etotyl, and fenoxaprop‐P‐ethyl, were extracted from aqueous samples by micro‐solid‐phase extraction and subsequently determined by gas chromatography with mass spectrometry. The effect of different parameters influencing the extraction efficiency of these herbicides including sample flow rate, sample volume, and extraction time were investigated and optimized. Under optimum conditions, linear calibration curves in the range of 0.10–500 ng/L with R2 > 0.99 were obtained. The relative standard deviation at 50 μg/L concentration level was lower than 10% (n = 5) and detection limits were between 0.05 and 0.20 μg/L. The proposed method was successfully applied to the sampling and extraction of herbicides from Zayanderood and paddy water samples.  相似文献   

19.
A selective and sensitive method was developed based on dispersive micro‐solid‐phase extraction for the extraction of hydroquinone, resorcinol, pyrocatechol and phenol from water samples prior to high‐performance liquid chromatography with UV detection. SiO2, SiO2@MPTES, and SiO2@MPTES@Au nanoparticles (MPTES = 3‐mercaptopropyltriethoxysilane) were synthesized and characterized by scanning electronic microscopy, thermogravimetric analysis, differential thermogravimetric analysis, and infrared spectroscopy. Variables such as the amount of sorbent (mg), pH and ionic strength of sample the solution, the volume of eluent solvent (μL), vortex and ultrasonic times (min) were investigated by Plackett–Burman design. The significant variables optimized by a Box–Behnken design were combined by a desirability function. Under optimized conditions, the calibration graphs of phenol and dihydroxybenzenes were linear in a concentration range of 1–500 μg/L, and with correlation coefficients more than 0.995. The limits of detection for hydroquinone, resorcinol, pyrocatechol, and phenol were 0.54, 0.58, 0.46, and 1.24 μg/L, and the limits of quantification were 1.81, 1.93, 1.54, and 4.23 μg/L, respectively. This procedure was successfully employed to determine target analytes in spiked water samples; the relative mean recoveries ranged from 93.5 to 98.9%.  相似文献   

20.
A novel method for the analysis of (3‐hydroxypropyl)mercapturic acid (HPMA), a major acrolein metabolite in human urine incorporating a molecularly imprinted solid‐phase extraction (MISPE) process using N‐acetylcysteine ‐imprinted mesoporous silica particles coupled with LC‐MS/MS detection was developed. The molecularly imprinted mesoporous silica particles were synthesized based on the supported material of ordered mesoporous silica SBA‐15 with N‐acetylcysteine (NAC) as template using surface molecular imprinting technology. The condition of MISPE procedures was optimized. The use of MISPE improved the accuracy and precision of the LC‐MS method and lowered the limit of detection (0.23 ng/mL). The recoveries at three spiked levels ranged between 88.5% to 108.6%. The developed MISPE method enabled the selective extraction of HPMA successfully in human urine and could be used as an effective approach for the determination of ultra‐trace HPMA in complex biological matrices. The results in real samples showed that median levels of HPMA were significantly higher (1922.0 ng/mg of creatinine, N = 75) in smokers than in nonsmokers (759.1 ng/mg of creatinine, N = 5), demonstrating the higher acrolein uptake in smokers than in nonsmokers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号