首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Electrochemical oxidation of azoxystrobin, a systemic fungicide commonly used in agriculture to protect a wide variety of crops, was investigated using cyclic voltammetry with a boron‐doped diamond electrode (BDDE) in aqueous buffer solutions. Two pH independent irreversible anodic current peaks controlled mostly by diffusion were observed in wide pH range (2 to 12) at potentials +1600 mV and +2150 mV vs. saturated silver‐silver chloride electrode. Mechanism of the electrochemical oxidation was proposed and supported with high performance liquid chromatography/mass spectrometry analysis of azoxystrobin solutions electrolyzed on carbon fiber brush electrode. The main product of the first two‐electron oxidation step was identified as methyl 2‐(2‐{[6‐(2‐cyanophenoxy)pyrimidin‐4‐yl]oxy}phenyl)‐2‐hydroxy‐3‐oxopropanoate. An analytical method for the determination of azoxystrobin in water samples and pesticide preparation by differential pulse voltammetry with BDDE was developed. The method provides a wide linear dynamic range (3.0×10?7 to 2.0×10?4 mol L?1) with limit of detection 8×10?8 mol L?1. Accuracy of the method was evaluated by the addition and recovery method with recoveries ranging from 96.0 to 105.8 %. Interference study proved sufficient selectivity of the developed voltammetric method for the azoxystrobin determination in presence of azole fungicides as well as pesticides used to prevent the same crops.  相似文献   

2.
In this article, for the first time, the analytical method for determination of a novel antagonist of A2A adenosine receptors (8‐(4‐methoxyphenyl)‐4‐oxo‐4,6,7,8‐tetrahydroimidazo[2,1‐c][1,2,4]triazine‐3‐carbohydrazide, namely IMT), which can be used as a drug for liver diseases, was presented. For this purpose a commercially available boron‐doped diamond electrode (BDDE) in combination with differential pulse voltammetry (DPV) was applied. It was found by cyclic voltammetry (CV) that IMT displays at BDDE, as a sensor, two well‐defined oxidation peaks at potentials of 0.81 and 1.18 V and one reduction peak at 1.1 V vs. Ag/AgCl in 0.1 mol L?1 acetate buffer (pH 4.5±0.1). The oxidation and reduction mechanism of IMT was proposed. The developed DPV method allowed the successful determination of IMT in the range of 0.05–50 μmol L?1 with detection limit equal to 0.0094 μmol L?1 and without any chemical modifications and electrochemical pretreatment of the electrode surface. The proposed procedure allows the determination of IMT in vitro directly from urine samples.  相似文献   

3.
《Electroanalysis》2017,29(4):1180-1187
The voltammetric behavior of ramipril (RMP), an angiotensin‐converting enzyme inhibitor, was investigated for the first time in the literature on a boron‐doped diamond electrode (BDDE) using cyclic (CV) and square‐wave voltammetry (SWV). Its behavior was also considered in the presence of a thiazide diuretic, hydrochlorothiazide (HCTZ), for the simultaneous determination. The performance of BDDE and glassy carbon electrode (GCE) was compared, since RMP provides a high oxidation potential. It was observed that the anodic peak potentials for HCTZ and RMP at the BDDE were 1.23 and 1.67 V (vs . Ag/AgCl (3.0 mol L‐1 KCl)) by CV in BR buffer solution (pH 2.0), respectively. The influence of supporting electrolyte, pH and scan rate in the current response of these both drugs was examined to select optimum experimental conditions. By this way, the determination of RMP and its association with HCTZ using SWV and a BDDE was successfully applied in real samples (single and combined dosage forms), with results in close agreement at 95% confidence level with those obtained using high‐performance liquid chromatography.  相似文献   

4.
《Electroanalysis》2017,29(10):2340-2347
This paper proposes the use of the boron‐doped diamond electrode (BDDE) in flow and batch injection analysis (FIA and BIA) systems with multiple‐pulse amperometric (MPA) detection for the determination of warfarin (WA) in pharmaceutical formulations. The electrochemical behavior of WA obtained by cyclic voltammetry (CV) in 0.1 mol L−1 phosphate buffer shows an irreversible oxidation process at +1.0 V (vs Ag/AgCl). The MPA was based on the application of two sequential potential pulses as a function of time on BDDE: (1) for WA detection at +1.2 V/100 ms and; (2) for electrode surface cleaning at −0.2 V/200 ms. Both hydrodynamic systems (FIA‐MPA and BIA‐MPA) used for WA determination achieved high precision (with relative standard deviations around 2 %, n =10), wide linear range (2.0−400.0 μmol L−1), low limits of detection (0.5 μmol L−1) and good analytical frequency (94 h−1 for FIA and 130 h−1 for BIA). The WA determination made by the proposed methods was compared to the official spectrophotometric method. The FIA‐MPA and BIA‐MPA methods are simple and fast, being an attractive option for WA routine analysis in pharmaceutical industries.  相似文献   

5.
A highly sensitive and selective chemical sensor was prepared based on metallic copper‐copper oxides and zinc oxide decorated graphene oxide modified glassy carbon electrode (Cu?Zn/GO/GCE) through an easily electrochemical method for the quantification of bisphenol A (BPA). The composite electrode was characterized via scanning electron microscopy (SEM), X‐Ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). The electrochemical behavior of BPA in Britton‐Robinson (BR) buffer solution (pH 7.1) was examined using cyclic voltammetry (CV). Under optimized conditions, the square wave voltammetry (SWV) response of Cu?Zn/GO/GCE towards BPA indicates two linear relationships within concentrations (3.0 nmol L?1?0.1 μmol L?1 and 0.35 μmol L?1?20.0 μmol L?) and has a low detection limit (0.88 nmol L?1). The proposed electrochemical sensor based on Cu?Zn/GO/GCE is both time and cost effective, has good reproducibility, high selectivity as well as stability for BPA determination. The developed composite electrode was used to detect BPA in various samples including baby feeding bottle, pacifier, water bottle and food storage container and satisfactory results were obtained with high recoveries.  相似文献   

6.
An electrochemical study of the anthelmintic drug bithionol using edge plane pyrolytic graphite electrode (EPPGE) is presented for the first time by applying different electrochemical techniques, such as cyclic voltammetry (CV), square‐wave voltammetry (SWV), square‐wave adsorptive stripping voltammetry (SWAdSV), and alternating current (AC) impedance spectroscopy. Mechanistic aspects of the electrode reaction were studied implying a quasireversible electrode reaction from an adsorbed state of the reactant, coupled with a follow‐up chemical reaction to a final electroinactive product. The overall mechanism appears totally irreversible under conditions of CV at moderate scan rate, while being quasireversible under conditions of the fast SWV. Furthermore, an optimisation of the analytical procedure for quantitative determination of bithionol was conducted by applying SWV in an adsorptive stripping mode. The calibration curve was constructed in the concentration range of 0.1–1.0 μmol L?1 (R2=0.9984) with a sensitivity of 3.6 μA L μmol?1 and LOD of 26.7 nmol L?1. The simple and sensitive SWAdSV procedure was proved to be suitable for the analysis of spiked urine samples.  相似文献   

7.
An electrochemical method was developed for the sensitive determination of chlorogenic acid using a boron doped diamond electrode (BDDE) modified with nano‐carbon black (nano‐CB). The active surface areas were found to be 0.059 and 0.146 cm2 for the unmodified BDDE, and nano‐CB/BDDE, respectively. Compared with a BDDE, the nano‐CB/BDDE exhibited a well‐defined redox couple for chlorogenic acid. In addition, the plot of the peak current response changing from a square root to a linear dependence on scan rate is attributed to the transition from planar diffusion to surface behaviour. The anodic and cathodic peak separations (ΔEp) were 97 mV and 14 mV at BDDE and nano‐CB/BDDE, respectively. The decrease in ΔEp at the proposed electrode indicated that the process of chlorogenic acid was greatly accelerated. Square wave voltammetry (SWV) exhibited a dynamic range in which the current versus the concentration of chlorogenic acid were linear from 2.0×10?8 to 2.0×10?6 M with a LOD of 4.1×10?9 M (based on 3Sb/m). The nano‐CB modified BDDE provided improved electrochemical behavior, high electrocatalytic activity, high sensitivity and good reproducibility.  相似文献   

8.
《Electroanalysis》2004,16(4):268-274
An amperometric method for the determination of the neurotoxic amino acid β‐N‐oxalyl‐L ‐α,β‐diaminopropionic acid (β‐ODAP) using a screen printed carbon electrode (SPCE) is reported. The electrode material was bulk‐modified with manganese dioxide and used as a detector in flow injection analysis (FIA). The enzyme glutamate oxidase (GlOx) was immobilized in a Nafion‐film on the electrode surface. The performance of the biosensor was optimized using glutamate as an analyte. Optimum parameters were found as: operational potential 440 mV (vs. Ag/AgCl), flow rate 0.2 mL min?1, and carrier composition 0.1 mol L?1 phosphate buffer (pH 7.75). The same conditions were used for the determination of β‐ODAP. The signal was linear within the concentration range 53–855 μmol L?1 glutamate and 195–1950 μmol L?1 β‐ODAP. Detection limits (as 3σ value) for both analytes were 9.12 and 111.0 μmol L?1, respectively, with corresponding relative standard deviations of 3.3 and 4.5%. The biosensor retained more than 73% of its activity after 40 days of on‐line use.  相似文献   

9.
The voltammetric behavior of 3‐nitrofluoranthene and 3‐aminofluoranthene was investigated in mixed methanol‐water solutions by differential pulse voltammetry (DPV) at boron doped diamond thin‐film electrode (BDDE). Optimum conditions have been found for determination of 3‐nitrofluoranthene in the concentration range of 2×10?8–1×10?6 mol L?1, and for determination 3‐aminofluorathnene in the concentration range of 2×10?7–1×10?5 mol L?1, respectively. Limits of determination were 3×10?8 mol L?1 (3‐nitrofluoranthene) and 2×10?7 mol L?1 (3‐aminofluoranthene).  相似文献   

10.
This work reports the highly‐sensitive amperometric determination of free glycerol in biodiesel at a gold electrode adapted in a flow‐injection analysis (FIA) cell. The amperometric method involved the continuous application of three sequential pulses to the working electrode (+250 mV, +700 mV, and ?200 mV, for 100 ms each). This sequence of potential pulses eliminated electrode passivation and dramatically increased the analytical signal. The proposed FIA‐amperometric method presented low relative standard deviation between injections (1.5 %, n=15), high analytical frequency (85 h?1), satisfactory recovery values (93–118 %) for spiked samples, wide linear range (from 1 to 300 µmol L?1), and low detection limit (0.5 µmol L?1).  相似文献   

11.
The electrochemical oxidation of ibuprofen at a boron‐doped diamond electrode (BDDE) and its voltammetric determination is reported for the first time. A well‐defined oxidation peak was observed at around 1.6 V in 0.1 mol L?1 H2SO4 solution with 10 % (v/v) ethanol at the BDDE surface activated by either cathodic or anodic pretreatments. A differential‐pulse voltammetric method for the determination of ibuprofen in pharmaceutical formulations was optimized with a detection limit of 5 µmol L?1 and compared with the British Pharmacopeia method.  相似文献   

12.
A novel silsesquioxane material was synthetized and used as a stabilizing agent for silver nanoparticles. This hybrid material was characterized by FTIR, 29Si CP‐MAS NMR, 13C DEPT 135° NMR and TGA techniques and the silver nanoparticles were characterized from DLS, UV‐Vis spectroscopy, zeta‐potential, TEM and SAXS results. The silver nanoparticles obtained were spherical in shape with a diameter of 3.74 nm. The nanomaterial was successfully applied in the modification of a glassy carbon electrode and a pronounced current response was obtained in the determination of the biomarker 4‐nitrophenol. Quantum chemical calculations, using density functional theory, were also performed in order to evaluate the redox properties of the analyte. Two different linear ranges were obtained applying optimal square wave voltammetry conditions. The reduction peak currents obtained were linear for 4‐NP concentrations in the ranges of 0.29 to 1.50 μmol L?1 (Ed=?0.6 V and td=20 s) and 2.75 to 31.5 μmol L?1, with a theoretical (signal to noise=3) limit of detection of 0.05 μmol L?1 (td=20 s). The proposed method was successfully applied to the determination of 4‐NP in synthetic serum samples at different levels of 4‐NP with a recovery range of 94–101 %. Validation was performed using a comparative method through the capillary electrophoresis (CE) technique.  相似文献   

13.
《Electroanalysis》2005,17(17):1517-1522
In this paper, we report the first attempt to use humic acid (HA) as modifiers to prepare the organic‐inorganic hybrid modified glassy carbon electrodes based on HA‐silica‐PVA (poly(vinyl alcohol)) sol‐gel composite. Electroactive species of tris(2,2′‐bipyridyl)ruthenium(II) (Ru(bpy) ) can easily incorporate into the HA‐silica‐PVA films to form Ru(bpy) modified electrodes. The amount of Ru(bpy) incorporated in the composite films strongly depends on the amount of HA in the hybrid sol. Electrochemical and electrogenerated chemiluminescence (ECL) of Ru(bpy) immobilized in HA‐silica composite films coated on a glassy carbon electrode have been studied with tripropylamine (TPA) as the coreactant. The analytical performance of this modified electrode was evaluated in a flow injection analysis (FIA) system with a homemade flow cell. The as‐prepared electrode showed good stability and high sensitivity. The detection limits (S/N=3) were 0.050 μmol L?1 for TPA and 0.20 μmol L?1 for oxalate, and the linear ranges were from 0.10 μmol L?1 to 1.0 mmol L?1 for TPA and from 1.0 μmol L?1 to 1.0 mmol L?1 for oxalate, respectively. The resulting electrodes were stable over two months.  相似文献   

14.
The applicability of the subtractive anodic stripping voltammetry (SASV) using the square‐wave mode at the silver‐gold alloy electrode has been studied for thallium determination in the presence of large amount of lead and cadmium in natural samples. 10 mmol L?1 perchloric acid was found as the most suitable supporting electrolyte for determination in synthetic solutions. The thallium peak was separated about 200 mV from Cd+Pb peak. Diethylenetriaminepentaacetic acid addition was necessary to determine thallium at the silver‐gold alloy electrode in digested plant and sediment. The determination limit was equal to 1.4 μg L?1. The method was validated by the inter‐method comparison (ICP‐MS).  相似文献   

15.
A graphite‐polyurethane composite electrode has been used for the determination of furosemide, a antihypertensive drug, in pharmaceutical samples by anodic oxidation. Cyclic voltammetry and electrochemical impedance spectroscopy were used to characterize the electrooxidation process at +1.0 V vs. SCE over a wide pH range, with the result that no adsorption of analyte or products occurs, unlike at other carbon‐based electrode materials. Quantification was carried out using cyclic voltammetry, differential pulse voltammetry, and square‐wave voltammetry. Linear ranges were determined (up to 21 μmol L?1 with cyclic voltammetry) as well as limits of detection (0.15 μmol L?1 by differential pulse voltammetry). Four different types of commercial samples were successfully analyzed. Recovery tests were performed which agreed with those obtained by spectrophotometric evaluation. The advantages of this electrode material for repetitive analyzes, due to the fact that no electrode surface renewal is needed owing to the lack of adsorption, are highlighted.  相似文献   

16.
《Electroanalysis》2006,18(3):253-258
The anodic voltammetric behavior of carbaryl on a boron‐doped diamond electrode in aqueous solution is reported. The results, obtained by square‐wave voltammetry at 0.1 mol L?1 Na2SO4 and pH 6.0, allow the development of a method to determine carbaryl, without any previous step of extraction, clean‐up, preconcentration or derivatization, in the range 2.5–30.0×10?6 mol L?1, with a detection limit of 8.2±0.2 μg L?1 in pure water. The analytical sensitivity of this electrochemical method diminished slightly, from 3.07 mA mmol?1 L to 2.90 mA mmol?1L, when the electrolyte was prepared with water samples collected from two polluted points in an urban creek. In these conditions, the recovery efficiencies obtained were around 104%. The effect of other pesticides (fenthion and 4‐nitrophenol) was evaluated and found to exert a negligible influence on carbaryl determination. The square‐wave voltammetric data obtained for carbaryl were typical of an irreversible electrode process with mass transport control. The combination of square‐wave voltammetry and diamond electrodes is an interesting and desirable alternative for analytical determinations.  相似文献   

17.
We propose an electrochemical sensor based on applying two successive thin layers from a mixture of multiwalled carbon nanotubes‐ionic liquid crystal and crown ether at glassy carbon electrode surface (GC/(CNTs‐ILC)/Crown). The sensor was used for sensitive determination of neurotransmitters based on effective synergism between its components. The compact conducting surface of (CNTs ‐ ILC) with large surface area allowed the assembling of stable host‐guest inclusion complexes between crown ethers and neurotransmitters. The GC/(CNTs‐ILC)/Crown exhibited excellent electro‐catalytic activity toward the determination of serotonin (ST) in a wide linear dynamic range: 0.005 μmol L?1 to 100 μmol L?1. In the concentration range 0.005 μmol L?1 to 1 μmol L?1, the detection limit is 2.03×10?10 mol L?1 and quantification limit is 6.78×10?10 mol L?1 with correlation coefficient 0.999. The sensor was successfully applied for ST detection in human serum samples with satisfied recovery results. The sensor showed excellent analytical performance for the determination of ST in terms of low detection limit, good sensitivity and reproducibility. Furthermore excellent anti‐interference ability and simultaneous determination of ST in presence of other compounds as ascorbic acid, dopamine and antidepressant drug were achieved.  相似文献   

18.
An electrochemical method for the simultaneous determination of benzene, toluene and xylenes (BTX) in water was developed using square‐wave voltammetry (SWV). The determination of BTX was carried out using a cathodically pre‐treated boron‐doped diamond electrode (BDD) using 0.1 mol L?1 H2SO4 as supporting electrolyte. In the SWV measurements using the BDD, the oxidation peak potentials of the total xylenes‐toluene and toluene‐benzene couples, present in ternary mixtures, display separations of about 100 and 200 mV, respectively. The attained detection limits for the simultaneous determination of benzene, toluene and total xylenes were 3.0×10?7, 8.0×10?7 and 9.1×10?7 mol L?1, respectively. The recovery values taken in ternary mixtures of benzene, toluene and total xylenes in aqueous solutions are 98.9 %, 99.2 % and 99.4 %, respectively.  相似文献   

19.
In this work, a simple and low‐cost method was developed for the simultaneous determination of the antioxidants tert‐butylhydroquinone (TBHQ) and butylated hydroxyanisole (BHA) in the presence of the cationic surfactant CPB by square wave voltammetry (SWV) technique using a carbon black paste electrode (CBPE). The performance of the method was investigated by varying parameters such as pH, electrolyte, and type and concentration of surfactant. Under the optimum conditions of 0.2 mol L?1 phosphate buffer (pH 7.0), 600.0 μmol L?1 of cetylpyridinium bromide surfactant and SWV operating parameters optimized through the Doehlert matrix, the method presented low limits of quantification for TBHQ and BHA (0.23 and 0.26 μmol L?1, respectively) and high precision in successive measurements. The proposed method was applied in mayonnaise, margarine and biodiesel and the accuracy of method was checked by the HPLC technique.  相似文献   

20.
Using 3‐Aminopropyltriethoxysilane(APTES) as a single silica source, an amino‐rich ultrafine organosilica‐nanoparticle‐modified Au electrode was fabricated, following the formation of (3‐mercaptopropyl)‐trimethoxysilane (MPTS) monolayer on Au surface (MPTS/Au). With cetyltrimethylammonium bromide as an additive, APTES‐based gel particles on the electrode have a narrow particle size distribution of 4–7 nm and “crystal‐like” structure. AFM and electrochemical characterization confirmed the successful grafting of APTES nanoparticles on MPTS/Au. The APTES/MPTS/Au electrode is highly sensitive for the detection of copper(II) ions with a detection limit as low as 1.6×10?12 mol L?1 (S/N>3) by square wave voltammetry. The current is linear to copper(II) concentration between 1.6×10?12 and 6.25×10?10 mol L?1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号