首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Kurt Grob introduced splitless injection in 1969. He elaborated most of the working guidelines including the techniques required for reconcentrating the broad intial bands, i.e. the solvent effects and cold trapping. He also designed a vaporizing injector suited for splitless injection. Nevertheless, splitless injection is still often carried out using inappropriate conditions, and many of today's vaporizing injectors are not suited for splitless injection. No autosampler is available that introduces the sample at the appropriate position. Conventional splitless injection is compared to PTV splitless injection for the range of samples that cannot be handled by the anyway superior oncolumn injection, i.e. sample with high loads of involatile byproducts. There is a clear preference for PTV splitless injection as matrix effects observed in conventional splitless injection were found to be substantially reduced or even eliminated.  相似文献   

2.
The performance of split and splitless programmed-temperature (PTV) injection is compared to cold on-column and hot (classical) split injection for the analysis of triglycerides on an apolar capillary gas chromatographic column. Quantitative accuracy and precision of PTV injection are determined for a synthetic mixture of triglycerides relative to cold on-column injection.  相似文献   

3.
Temperature programmable injectors with liner diameters ranging from 1 to 3.5 mm are evaluated and compared for solvent split injection of large volumes in capillary gas chromatography. The liner dimensions determine whether a large sample volume can be introduced rapidly or has to be introduced in a speed controlled manner. The effect of the injection technique used on the recovery of n-alkanes is evaluated. Furthermore the influence of the liner diameter on the occurrence of thermal degradation during splitless transfer to the analytical column is studied. Guidelines are given for the selection of the PTV liner internal diameter best suited for specific applications.  相似文献   

4.
Sampling techniques for practical quantitative capillary GC have to meet certain principal requirements. Both the absolute and the relative peak areas (e.g. column loads) must be reproducible with high precision and at high accuracy; discrimination of certain constituents according to their volatility should not take place on sampling. On the basis of systematic studies, the three most reliable sampling techniques used for GC analyses with the aim of achieving precise and accurate quantitative data proved to be the following: On-column, injection, splitless PTV injection, and an optimized version of split sampling called “cooled needle split” injection. The on-column technique can be optimized by using precolumns with wider internal diameters and without stationary phase coatings to overcome the problems of large liquid sampling volumes and for automation. The PTV technique should only be used in the splitless mode because discrimination cannot be suppressed completely with the split mode. All three of the techniques can be operated automatically, either to avoid “human interference”, i.e. to improve precision or for unattended operation to save man-power.  相似文献   

5.
A programmed temperature vaporizer (PTV) injection technique has been recently implemented in our laboratory. In present paper its performance is compared with other GC injection techniques commonly used in trace analysis of organic contaminants. Twenty-six pesticides representing different chemical classes were selected for the study. This group comprised compounds typically subjected to discrimination in the injection port of the gas chromatograph, e.g., polar organophosphorus pesticides and thermolabile carbamates. In the first set of experiments standards in pure solvent were injected into GC systems employing different types of injection, i.e., (i) on-column, (ii) pulsed splitless, (iii) PTV solvent split, (iv) PTV splitless, and the responses of analytes were compared. Discrimination of troublesome compounds was significantly decreased with the application of PTV solvent split injection. In the second set of experiments repetitive injections of purified wheat samples were performed, with aims to evaluate the long-term stability of responses, as well as matrix effects in different stages of system contamination for each injection technique. The tolerance of the GC system to co-injected matrix components was increased in the order: on-column相似文献   

6.
The trace analysis of polycyclic aromatic hydrocarbons (PAHs) in environmental matrices requires highly sensitive and selective methods. The use of large-volume injection in gas chromatography with mass spectrometry detection allows the improvement of the sensitivity. In this work, one of the most popular large-volume injectors, programmed temperature vaporization (PTV)-splitless injection, was optimized to determine 26 alkylated and non-alkylated PAHs at ultratrace levels. The injection conditions that use two different injection volumes, 10 and 25 μl, were optimized applying experimental designs. Six experimental factors that could affect the vaporization efficiency were studied. Detection limits for each assayed volume were compared with splitless injection, both in full scan and in SIM mode. An improvement of 50- and 100-fold, for 10 and 25 μl, respectively, was achieved for PAHs in comparison with splitless injection. Finally, the method that was optimized for 25 μl was applied successfully to the analysis of a certified marine sediment SRM 1941b and a real marine sediment extracted by microwave assisted extraction.  相似文献   

7.
The use of hot splitless, cold splitless, and on-column injections for trace analysis in narrow-bore capillary GC is evaluated. Despite the low flow rates for the columns used, the required splitless times for splitless injections can be surprisingly short if liners with a small inside diameter are used. On-column injection can be applied by using an appropriate normal-bore precolumn coupled to the narrow-bore analytical column using a specially designed low dead volume column connector. The effects of the experimental conditions such as sample volume, injection temperature, and initial oven temperature on peak focusing and the discrimination and degradation behavior of the analytes are discussed. The possibilities to obtain sensitive and fast separations are illustrated by various applications.  相似文献   

8.
Summary AGC method has been developed for the analysis of tricholoroacetic acid (TCA) in water samples. It entails large-volume injection (LVI) and programmed-temperature vaporization (PTV) of water samples, thermal decarboxylation of TCA to chloroform in the injector, and GC-ECD analysis of the decarboxylation product. Conditions such as final injector temperature, splitless time, and injection volume were optimized. The limit of detection is approximately 0.1 μg L−1 Several real samples were analyzed. The method presented is an easy means of determination of TCA and eliminates sample-preparation steps such as extraction and derivatization.  相似文献   

9.
An experiment has been designed to study the thermal degradation of thermolabile compounds caused by various injection techniques. The four carbamate pesticides aminocarb, bendiocarb, carbaryl, and dioxacarb decompose thermally into methylisocyanate and the corresponding phenol. The carbamets and the phenols arising from them were separated on a 25 m SE-54 fused silica column; all compounds exhibited sharp peak shape indicating that the degradation observed took place completely within the injector. When cold on-column injection was employed no thermal degradation was observed whereas with hot splitless injection at 220°C decomposition of the carbamates was almost complete. PTV injection was found to produce intermediate results. When packed with glass wool and operated with glass wool and operated with starting temperatures lower than the boiling point of the solvent, decomposition was found to be almost complete. Applying isothermal conditions at 140°C (30°C above the boiling point of toluene) aminocarb and bendiocarb underwent only slight decomposition while carbaryl and dioxacarb were about half degraded. Results from PTV injection with an empty insert resembled those obtained using cold on-column injection and in this mode the application of temperatures up to 200°C resulted in no visible degradation. This can be explained by the short residence time of the sample in the injector.  相似文献   

10.
The PTV (Programmable Temperature Vaporizer) is a split/splitless injector which allows the sample to be introduced at a relatively low temperature, thus affording accurate and reproducible sampling. After injection the PTV is rapidly heated to transfer the vaporized components into the capillary column. This type of injector has proved to be an efficient tool for the evaluation of fatty acids, essential oils, and pesticides in food analysis. In this work the suitability of PTV for the analysis of milk fat purity by the Official EU method was evaluated. This method is based on the gas chromatographic determination of triglycerides only according to their total number of carbon atoms followed by the application of formulae deriving from multiple linear regressions. The analysis is currently carried out with a packed column or a short capillary column and an on-column injection system. Several samples of pure milk fat and mixtures of milk fat with foreign fat were analyzed with the same capillary column and by using both PTV and on-column injection systems. The results show that the gas chromatographic profile obtained by PTV is comparable with that obtained by the on-column injector, while repeatability and reproducibility data meet the requirements indicated in the Official Method. Therefore, this study demonstrates that it is possible to use the PTV instead of the on-column injector to determine the purity of milk fat with this method.  相似文献   

11.
大体积进样技术在环境分析中的应用   总被引:2,自引:0,他引:2  
汤凤梅  倪余文  张海军  陈吉平 《色谱》2010,28(5):442-448
在毛细管气相色谱法(CGC)中,采用大体积进样技术(LVI),即使用能够容纳大体积样品的进样装置以及增加可控时间的溶剂蒸汽放空装置,可以满足环境样品中超痕量组分的分析要求,简化样品浓缩步骤以及实现液相色谱(LC)与CGC的在线联用。针对分析物的性质、毛细管柱的规格和分析的目的已发展了多种LVI。本文总结了几种常见的LVI,包括柱头进样(OCI)和程序升温进样(PTV),以及近年来发展的一些新技术,如在柱同时溶剂浓缩进样、样品直接引入进样/复杂基质进样和同时溶剂冷凝无分流进样,阐述了各种进样技术的基本原理及其与样品提取、LC纯化在线联用的方法在环境分析应用中的一些最新研究进展。  相似文献   

12.
In this paper, we present an investigation of the influence of the gas chromatographic separation system on the determination of polybrominated diphenyl ethers (PBDEs). Capillary columns, retention gaps and press-fit connectors, as well as different injection techniques have been evaluated with respect to yield and repeatability. The split/splitless injection has been optimized and compared to on-column injection, the septum equipped temperature programmable injector (SPI) and the programmable temperature vaporizing (PTV) injector. Furthermore, a comparison of the different operational modes of the PTV injector is presented. The results show that there are large variations in the yield of PBDEs depending on the column and the injection systems. Especially the high molecular weight BDE congeners can be subject to severe discrimination. Unfavorable conditions can lead to a complete loss of nona and deca substituted BDE congeners.  相似文献   

13.
An online GC–MS-system for automated monitoring of crude wastewater at a complex chemical production site is presented. The modular system is, in principal, based on commercial equipment, but utilizes a special, two-stage injector, which consists of a splitless vaporization chamber on top of a PTV injector filled with Tenax. This set-up enables direct injection of wastewater. Almost 140 volatile and semi-volatile compounds are calibrated down to 1 mg L−1, which is sufficient for analysis of the influent of the wastewater-treatment plant. Two instruments analyze alternately, every 20 min, and the instrument cycle time is 40 min. The quantitative results are transferred to a database which is connected to a process-control system. Depending on the nature and concentration of a compound, an alarm can be generated and the wastewater stream can be diverted into an “off spec tank” if necessary. The GC–MS-system operates quasi-continuously with a system availability >98%. Data quality is automatically controlled in each run and by daily analysis of a quality-control sample. The development of a novel stacked PTV–PTV injector design to expand the range of analytes to selected basic compounds is described.  相似文献   

14.
Hydroxylated polychlorobiphenyls (polyhydroxy-PCBs) are subjected to severe discrimination effect when they are introduced into a capillary gas chromatograph by splitless injection. This effect can be considerably reduced by using a pulsed pressure injection to favor sample transfer and by further programming the eluent gas pressure during the GC run. By multistep gas pressure programming, splitless injection provides analytical performances and chromatograms for (poly)hydroxy-PCBs closely resembling those obtained by on-column injection, whose use is generally discouraged with real environmental samples. Among the six model compounds studies, the dihydroxy congeners exhibit the best results.  相似文献   

15.
Cooled needle sampling using syringes was applied to splitless injection and to simulated distillation analyses. Slight changes of the construction of the previous device are also described. The changes concern the temperature profile within the injector and especially the vaporization insert. Even with the low carrier gas flow through the injector during splitless injection, discrimination by component volatility can be avoided. Precision and accuracy of simulated distillation data obtained with split sampling also can be improved by the cooled needle technique.  相似文献   

16.
Analytical methods are described for identification and monitoring of the oxygenated metabolites of dibenzothiophene. Since such compounds are thermolabile, GC analysis is seen to be hardly feasible with conventional injectors such as all-glass moving needle or splitless injectors. Only on-column injection gives no degradation products. In addition, reversed-phase HPLC is particularly suitable for the analysis of the sulfone or sulfoxides of dibenzothiophenes.  相似文献   

17.
Injector overflow is determined quantitatively by analysis of the septum purge effluent. Vaporizing chambers must have an internal volume of about 1 ml (e.g. 80 × 3.6 mm i.d.). This allows splitless injection of volumes between 1 and 2.5 μl, depending on the solvent. The septum purge should be closed during splitless transfer to prevent losses by back-diffusion.  相似文献   

18.
王亚韡  张庆华  江桂斌  贺卿 《色谱》2007,25(1):21-24
利用大体积进样技术(large volume injection,LVI),结合气相色谱-质谱方法对二英的测定效果进行了研究。同时与传统分流/不分流进样技术进行了对比。对进样体积为1,5,10,25,50和100 μL的色谱图进行了分析。研究表明使用大体积进样方式,在不影响色谱分离度的同时,大幅度提高了分析灵敏度。通过对土壤样品的检测,证明该方法可以用于环境样品的实际测定。  相似文献   

19.
The capillary gas chromatographic analysis of complex naturally occurring and food-product triglyceride mixtures is accomplished qualitatively and quantitatively on columns coated with methyl and methyl-phenyl (65%) silicones using programmed-temperature split/splitless and on-column injection. Faster analysis times are achieved using elevated initial column oven temperatures with cold initial injector temperatures.  相似文献   

20.
Injector-internal thermal desorption is a promising technique for the analysis of a wide range of food components (e.g., flavors) or food contaminants (e.g., solvent residues, pesticides, or migrants from packaging materials) in edible oils and fats or fatty food extracts. Separation from the fatty matrix occurs during injection. Using programmed temperature vaporizing (PTV) injection, the oily sample or sample extract was deposited on a small pack of glass wool from which the components of interest were evaporated and transferred into the column in splitless mode, leaving behind the bulk of the matrix. Towards the end of the analysis, the oil was removed by heating out the injector and backflushing the precolumn. The optimization dealt with the gas supply configuration enabling backflush, the injector temperature program (sample deposition, desorption, and heating out), separation of the sample liquid from the syringe needle and positioning it on a support, deactivation of the support surface, holding the plug of fused silica wool by a steel wire, and the analytical sequence maintaining adsorptivity at the desorption site low. It was performed for a mixture of poly(vinyl chloride) (PVC) plasticizers in oil or fatty food. Using MS in SIM, the detection limit was below 0.1 mg/kg for plasticizers forming single peaks and 1 mg/kg for mixtures like diisodecyl phthalate. For plasticizers, RSDs of the concentrations were below 10%; for the slip agents, oleamide and erucamide, it was 12%. The method of incorporating PTV injection was used for about one year for determining the migration from the gaskets of lids for glass jars into oily foods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏