 共查询到20条相似文献,搜索用时 265 毫秒
1.
The speed of analysis in capillary gas chromatography can be substantially increased by reduction of the column inner diameter. However, special demands are then posed upon instrumental design. In particular, the sampling system is highly critical because it has to be capable of delivering extremely small injection band widths which must be compatible with the column inside diameter. This study focuses on the evaluation of two potentially suitable sample introduction systems with respect to input band width and detection limits and their compatibility with small bore (≦ 100 μm) columns in capillary gas chromatography. One of them allows liquid on-column injection, based on liquid splitting, of only a few nl onto small bore (≦ 100 ?m) fused silica columns. For gases, input band widths as low as 1 ms are obtained with this system. The other one is part of a miniaturized gas chromatograph with extremely low dead volume interfaces and detector volumes. It allows input band widths for gases of a few ms. Without any preconcentration ppm concentrations are measured in gaseous samples with a 80 ?m thick film capillary column. It will be shown that a further reduction of the minimum detectable amount and analysis time is possible with this equipment.  相似文献   

2.
The need for faster and more efficient separations of complex mixtures of organic compounds by gas chromatography has led to the development of small inner diameter open tubular columns. Owing to their decreased plate height, extremely narrow peaks are obtained. When differently sized columns with equal plate numbers are compared, injection of a fixed amount of a solute will give the highest detector signals for the smallest bore columns. When P is defined as the ratio of the column inlet and outlet pressures, it can be seen from theory that under normalized chromatographic conditions the minimum detectable amount (Qº) for a mass flow sensitive detector increases proportionally to the square of the column diameter for P = 1. In the situation of greater interest in the practice of open tubular gas chromatography where P is large, a linear relationship is derived between Qº and the column diameter. It is a widespread misunderstanding, however, that narrow bore capillary columns should be used for this reason in trace analysis. If a fixed relative contribution of the injection band width to the overall peak variance is allowed, a decreased plate height drastically restricts the maximum sample volume to be injected. It is shown that the minimum analyte concentration in the injected sample (Cº) is inversely proportional to the column inner diameter when a mass flow sensitive detector is used. For actual concentrations less than Cº, sample preconcentration is required. The effect of peak resolution and selectivity of the stationary phase in relation to Cº and Qº will be discussed as well. The validity of the given theory is experimentally investigated. Minimum analyte concentrations and minimum detectable amounts are compared using columns with different inner diameter.  相似文献   

3.
A new design of a mass-flow controlled multidimensional switching system for capillary gas chromatography is introduced and discussed. Large sample amounts can be introduced with a required input band width onto the first column. A combination of cold sample introduction and successive high speed programmed heating of the injector liner is used for this purpose. The potential of such an approach for selective and fast high resolution separations with series coupled wide bore, thick film columns is emphasized, and illustrated for various concentrations.  相似文献   

4.
Abstract

The use of narrow bore separator columns (inner diameter less than 1 μM) in high performance liquid chromatography has become a well established technique which has obvious advantages in specific situations over the use of traditional size separator columns. The work reported here investigates the use of traditional ion chromatographic equipment (essentially unmodified) for use in narrow bore ion chromatography. The only adjustments made to the equipment were some arrangements in the placement of valves and tubing in order to minimize extra-column dead volume. The columns used in this work were glass capillary columns of 1.0 mm inner diameter. A selected group of ion exchange resins were slurry packed into the column and the retention and separation characteristics of the narrow bore column were determined. The results of this investigation indicate that in certain cases the commercially available equipment is adequate for performing narrow bore ion chromatography. The distinct advantage of the use of narrow bore ion chromatography is the lower flow rates used in the chromatographic procedure with a corresponding decrease in eluant consumption, eluant cost, and eluant disposal.  相似文献   

5.
Comprehensive two-dimensional gas chromatography (GC x GC) is based on a coupling of two GC columns of different characteristics by means of a device that allows portions of the effluent from the primary column to be injected onto the second dimension column for an additional separation. The time available for the separation in the second-dimension column is very short. Thus, this separation should be very efficient. The vast majority of GC x GC practitioners use very narrow bore columns for the second dimension. While this approach is justified in principle, if peaks in the second dimension overload this column, its peak capacity is severely reduced. A series of second-dimension columns of varying internal diameters, but similar phase ratios, were used to study these effects. The results indicate that 250 microm columns often provide comparable second dimension peak widths to 100 microm columns, while at the same time being less prone to overloading, indicating that they may often be a better choice than smaller diameter columns in the second dimension of GC x GC systems.  相似文献   

6.
Gas chromatography has the potential to be a much faster method of separation than is usually realized. If column operating conditions are optimized for speed and injection band width is minimized, some simple separations can be completed in a few seconds. A prototype cryofocusing system for producing narrow injection bands with 0.25-mm i.d. columns is described here. The gas-cooled and electrically heated inlet produces injection bands with widths of about 10-20 ms. In the present study the system is evaluated using mixtures of common organics, including alkanes, aromatics, alcohols, ketones, and chlorinated hydrocarbons. Quantitative trapping and reinjection is achieved for all tested compounds. Coefficients of variation are less than 3% for peak area and less than 0.2% for retention time. Base-line separation of simple mixture is achieved with retention times of less than 10 s. By using the cold trap inlet with a low-dead-volume detector and a high-speed electrometer, the efficiency available from commercial capillary columns can be better utilized, and retention times for some routine separations may be reduced to a few seconds.  相似文献   

7.
Stainless-steel tubes having inside diameters of 1.5 mm and 1.8 mm were packed with polystyrene gels of particle diameter 10 ± 2 μm. Two 50 cm × 1.8 mm I.D. packed columns, connected in series, were calibrated and molecular-weight averages of polystyrene NBS 706 were measured, the results coinciding with the data of the National Bureau of Standards. The peak widths of polystyrenes of narrow molecular-weight distributions in both semi-micro column (four 25 cm × 1.5 mm I.D.) and conventional column (two 50 cm × 8 mm I.D.; packed by the manufacturer) systems were determined at different mobile-phase velocities, and the minimum peak width in the latter system was obtained at the velocity of 0.2 mm/sec, which was higher than that for the semi-micro system. The interstitial volume was higher and the inner volume was lower for the semi-micro column system (1.8 mm I.D.) than those for the conventional one, which means that semi-micro columns were packed less densely, resulting in a steep calibration curve. The peak height of a solute was proportional to the cell length of an ultraviolet detector if the sample load was proportional to the cross-sectional areas of columns having the same column efficiency. Although conventional size-exclusion chromatography has many advantages in respect of velocity, calibration curtve and sample peak height, semi-micro size-exclusion chromatography still holds some merits such as low consumption of gels and of mobile-phase solvents.  相似文献   

8.
An analytical method based on a dual capillary gas chromatographic technique combining the advantages of GasPro PLOT and a non polar narrow bore WCOT column was developed for the analysis of air samples containing C2–C9 NMHCs. A refocusing step was not required due to the fast heating rate of the sample preconcentration trap and the resolving power of the PLOT column for C2 and C3 NMHCs. Water had to be removed from the air samples to avoid plugging of the columns if the initial GC oven temperature was below ambient temperature. To dry air samples, a scrubber and a cryogenic technique were employed. The interferences caused by carbon dioxide were reduced by purging the loaded sample preconcentration trap with helium. The dual column system was compared to a method employing a refocusing device and a single narrow bore WCOT column. Both systems provided a high degree of precision. However, the dual column approach was superior to the single column system due to better resolution of low molecular weight components.  相似文献   

9.
The resolution of the diastereoisomers of norpristane, pristane, and phytane was studied as a function of the column internal diameter and/or the residence time of the compounds in the column. Increasing the residence time in the column by operating the column at a lower temperature program rate enhances the resolution more than reducing the internal diameter of the column. Practical experience with ultra narrow bore columns is also presented.  相似文献   

10.
Pulsed flow modulation (PFM) is based on higher flow rate time compression of the first GC column effluent, which prior to the injection into the second column is stored for a few seconds in a standard fused silica wide bore transfer line. We constructed the PFM device with two standard 1/16 in. brass compression fittings with the insertion of the two columns inside the wide bore 0.53 mm i.d. fused silica storage transfer line for the elimination of dead volumes. This simple arrangement provides a combination of flexibility in the length of the sample storage transfer line hence comprehensive two-dimensional gas chromatography (GC x GC) cycle time, inert sample path and full elimination of cooling gas consumption. A record short second column injection time of 20 ms is demonstrated. Practical injection times are the sample collection time (such as 4s) divided by the second to first column flow rate ratio (such as 20/0.7), which is typically around 150 ms. Due to the low cost of the device it can also be considered for use with non comprehensive time segmented GC x GC to remove a few accidental coelutions. PFM-GCxGC excels with high second column capacity due to the use of 0.32 mm i.d. columns with high flow rates as the second dimension GC x GC column. As a result, PFM-GCxGC can have up to two orders of magnitude higher second column sample capacity and linear dynamic range for improved reduction of adverse matrix interference effects due to column overloading.  相似文献   

11.
The two current technologies for achieving comprehensive gas chromatography (GC×GC) – the thermal sweeper and the cryogenic modulator – are compared in an interlaboratory study using a multicomponent semi‐volatile aromatic compound sample. The same column set (phases, film thickness, dimensions of columns) and conditions of oven temperature program were used. Carrier gas flow settings however were different for the data reported here. The thermal sweeper has a longer overall length due to the extra ca. 30 cm length of narrow bore tubing used for the modulator/accumulator section. Data reveal that the two methods behave in an analogous manner in respect of delivering GC×GC results, with key peak parameters of peak widths and symmetry measures showing good correlation. Retention time dissimilarity on the first dimension columns in the two systems arises from different flow rates used, however the second column retention is similar, and this is due to the resulting different elution temperatures that peaks elute on the first dimension in each system. Overall, the two approaches to GC×GC appear to produce equivalent results within the scope of the application studied. Each system does have its experimental limitations; the thermal sweeper has what may be called a ‘thick film effect’, where at high temperature it can be difficult to sufficiently trap the migrating bands in the accumulator column, and the pulsing of solutes in the cryogenic system may suffer from a ‘thick wall effect’ if a column with too thick a wall dimension is used at low oven temperature.  相似文献   

12.
The preparation of wide bore (320 μm) and narrow bore (50 μm) fused silica capillary columns is described for immobilized cyanopropyl substituted silicones containing 60 and 88% substitution. The effect of high temperature deactivation with cyanopropylcyclosiloxanes was studied with a special test mixture. Curing was achieved with dicumyl peroxide or azo-tert-butane. The columns were evaluated and compared in terms of efficiency, activity, polarity, and temperature stability. Different coating methods were compared for the narrow bore columns. The activity of the 60% cyanopropyl columns that had been immobilized with dicumyl peroxide was significantly larger than for azo-tert-butane immobilized columns. The polarity of polar columns appeared to depend greatly on column temperature and is completely different for wide and narrow bore columns.  相似文献   

13.
A solvent delivery system is described that is designed to increase the efficiency of liquid chromatography-mass spectrometry (LC/MS) analyses. Gradients formed by using two low pressure syringe pumps are stored in a length of narrow bore tubing (gradient loop) mounted on a standard high pressure switching valve. The preformed gradient is pushed through the column by using a high pressure syringe pump. The system is fully automated and can be controlled with either a personal computer or the mass spectrometer data system. Advantages include gradient operation without the use of split flows, pressure programed flow control for rapid sample loading and recycling to initial conditions, and a flow rate range of 0.1–20 μL/min, which is suitable for packed capillary columns 50–500 μm in diameter. The system has been used extensively for rapid molecular weight determinations of intact protein samples, as well as LC/MS and liquid chromatography-tandem mass spectrometry analyses of complex peptide mixtures.  相似文献   

14.
The analysis of complex real-world samples of vegetable origin requires rapid and accurate routine methods, enabling laboratories to increase sample throughput and productivity while reducing analysis costs. This study examines shortening enantioselective-GC (ES-GC) analysis time following the approaches used in fast GC. ES-GC separations are due to a weak enantiomer-CD host-guest interaction and the separation is thermodynamically driven and strongly influenced by temperature. As a consequence, fast temperature rates can interfere with enantiomeric discrimination; thus the use of short and/or narrow bore columns is a possible approach to speeding-up ES-GC analyses. The performance of ES-GC with a conventional inner diameter (I.D.) column (25 m length x 0.25 mm I.D., 0.15 microm and 0.25 microm d(f)) coated with 30% of 2,3-di-O-ethyl-6-O-tert-butyldimethylsilyl-beta-cyclodextrin in PS-086 is compared to those of conventional I.D. short column (5m length x 0.25 mm I.D., 0.15 microm d(f)) and of different length narrow bore columns (1, 2, 5 and 10 m long x 0.10 mm I.D., 0.10 microm d(f)) in analysing racemate standards of pesticides and in the flavour and fragrance field and real-world-samples. Short conventional I.D. columns gave shorter analysis time and comparable or lower resolutions with the racemate standards, depending mainly on analyte volatility. Narrow-bore columns were tested under different analysis conditions; they provided shorter analysis time and resolutions comparable to those of conventional I.D. ES columns. The narrow-bore columns offering the most effective compromise between separation efficiency and analysis time are the 5 and 2m columns; in combination with mass spectrometry as detector, applied to lavender and bergamot essential oil analyses, these reduced analysis time by a factor of at least three while separation of chiral markers remained unaltered.  相似文献   

15.
By taking into consideration band broadening theory and using those results to select experimental conditions, and also by reducing the injection pulse width, peak capacity production (i.e., peak capacity per separation time) is substantially improved for one dimensional (1D-GC) and comprehensive two dimensional (GC×GC) gas chromatography. A theoretical framework for determining the optimal linear gas velocity (the linear gas velocity producing the minimum H), from experimental parameters provides an in-depth understanding of the potential for GC separations in the absence of extra-column band broadening. The extra-column band broadening is referred to herein as off-column band broadening since it is additional band broadening not due to the on-column separation processes. The theory provides the basis to experimentally evaluate and improve temperature programmed 1D-GC separations, but in order to do so with a commercial 1D-GC instrument platform, off-column band broadening from injection and detection needed to be significantly reduced. Specifically for injection, a resistively heated transfer line is coupled to a high-speed diaphragm valve to provide a suitable injection pulse width (referred to herein as modified injection). Additionally, flame ionization detection (FID) was modified to provide a data collection rate of 5kHz. The use of long, relatively narrow open tubular capillary columns and a 40°C/min programming rate were explored for 1D-GC, specifically a 40m, 180μm i.d. capillary column operated at or above the optimal average linear gas velocity. Injection using standard auto-injection with a 1:400 split resulted in an average peak width of ~1.5s, hence a peak capacity production of 40peaks/min. In contrast, use of modified injection produced ~500ms peak widths for 1D-GC, i.e., a peak capacity production of 120peaks/min (a 3-fold improvement over standard auto-injection). Implementation of modified injection resulted in retention time, peak width, peak height, and peak area average RSD%'s of 0.006, 0.8, 3.4, and 4.0%, respectively. Modified injection onto the first column of a GC×GC coupled with another high-speed valve injection onto the second column produced an instrument with high peak capacity production (500-800peaks/min), ~5-fold to 8-fold higher than typically reported for GC×GC.  相似文献   

16.
Molander P  Olsen R  Lundanes E  Greibrokk T 《The Analyst》2003,128(11):1341-1345
The impact of column inner diameter on chromatographic performance in temperature gradient liquid chromatography has been investigated in the present study. Columns with inner diameters of 0.32, 0.53, 3.2 and 4.6 mm were compared with respect to retention and efficiency characteristics using temperature gradients from 30 to 90 degrees C with temperature ramps of 1, 5, 10 and 20 degrees C min(-1). The columns were all of 15 cm length and were packed with 3 microm Hypersil ODS particles. Alkylbenzenes served as model compounds, and the mobile phase consisted of acetonitrile-water (50:50, v/v). The study revealed that the column ID is not a critical limiting factor when performing temperature programming in LC, at least for columns narrower than 4.6 mm inner diameter in the temperature interval 30-90 degrees C. The retention times for all components on all columns were highly comparable, with similar peak profiles without any signs of peak splitting. The use of mobile phase pre-heating when using the larger bore columns was avoided by starting the temperature gradients close to ambient. However, the relative apparent efficiency was inversely proportional to column inner diameter, making the capillary columns generally more functional towards temperature gradients than the larger bore columns with respect to chromatographic efficiency. In addition, the capillary columns possessed higher robustness towards temperature programming than the conventional columns.  相似文献   

17.
Band broadening in size-exclusion chromatography of polydisperse samples   总被引:1,自引:0,他引:1  
Understanding and controlling the band broadening is essential to obtain accurate molar-mass distributions by size-exclusion chromatography (SEC). In this paper, band broadening in SEC is reviewed from a contemporary perspective. The observed band broadening is due to dispersion inside and outside the chromatographic column (undesirable band broadening) and to the polydispersity of the sample (desirable SEC selectivity). The various contributors to band broadening are discussed. Integrity plots are introduced as a tool to evaluate the performance of specific SEC columns at given experimental conditions. For narrow polymer standards on single SEC columns the observed peak width is dominated by the chromatographic dispersion. MALDI-ToF-MS is demonstrated as an alternative to determine the PDI of narrowly distributed samples. The plate heights encountered at very high reduced velocities are found to be lower than expected. This is advantageous for fast separations by SEC.  相似文献   

18.
An injector designed for automatic direct liquid injection into narrow bore capillary GC columns has been constructed and evaluated. The tip of the syringe needle is aligned with, and positioned close to, the column entrance in a small, pressurized cavity: when the sample is dispensed it is immediately forced into the column by the action of the surrounding carrier gas. A standard autosampler equipped with a standard stainless steel syringe needle was utilized for at-column sample transfer into 100 μm i.d. columns. RSD values for n-alkanes were between 0.1 and 0.3% for relative area counts and approximately 1% for absolute area counts.  相似文献   

19.
In this work a fast gas chromatography set‐up with on‐column injection was optimized and evaluated with a model mixture of C8–C28 n‐alkanes. Usual injection volumes when using narrow‐bore (e. g., 0.1 mm i.d.) analytical columns are ca. 0.1 μL. The presented configuration allows introduction of 10–30‐fold larger sample volumes without any distortion of peak shapes. In the set‐up a normal‐bore retention gap (1 m×0.32 mm i. d.) was coupled to a narrow‐bore (4.8 m×0.1 mm i. d.×0.4 μm film thickness) analytical column using a low dead volume column connector. The effects of the experimental conditions such as inlet pressure, sample volume, initial injection temperature, and oven temperature on a peak focusing are discussed. H‐u curves for helium and hydrogen are used to compare their suitability for high speed gas chromatography and to show the dependence of separation efficiency on the carrier gas velocity at high inlet pressures. In the fast gas chromatography system a baseline separation of C10–C28 n‐alkanes was achieved in less than 3 minutes.  相似文献   

20.
Separations below 1 s of a mixture of organic compounds ranging from C5 to C8 have been performed to investigate the performance of a time-of-flight mass spectrometer in fast gas chromatography. The gaseous samples were focussed on a cold trap, and then injected after thermal desorption to obtain the required narrow input band-widths. Also, to obtain a very fast separation, a short narrow bore column was used, operated at above-optimum inlet pressures. With this system, it was possible to identify ten compounds within 500 ms, showing peak-widths (2.354sigma) as narrow as 12 ms. The spectral acquisition rate used for these analyses was 500 Hz. The quality of the recorded spectra and the comparison with library spectra was very high. Deconvolution algorithms offer the possibility of identifying overlapping peaks. It is shown that the spectral scan speed of the time-of-flight mass spectrometer is high enough for very fast separations.  相似文献   