1.
For clinical and environmental analyses utilizing capillary gas chromatography/mass spectrometry (GC/MS), increased sensitivity and speed of analysis are highly desirable. These performance advantages are realized using a WCOT column of 100 μm i.d. as compared to the more conventional 200 μm i.d. capillary columns. The improved sensitivity of capillary direct GC/MS with the 100 μm i.d. column for the confirmation of drugs of abuse will be demonstrated. For environmental analysis, the superior efficiency and resolution of the 100 μm i.d. column can be employed for the separation of priority pollutants. This approach is more amenable to capillary direct GC/MS providing a more effective interface to the mass spectrometer. As a result improved sensitivity and a considerable decrease in analysis time is achieved over that obtained with the larger diameter environmental specialty phase columns.  相似文献   

2.
气相色谱近年的发展   总被引:1,自引:0,他引:1  
傅若农 《色谱》2009,27(5):584-591
简要阐述了近几年气相色谱(GC)的发展和特点。GC是一个成熟的技术,广泛地应用于各个领域,近几年GC的发展除了继续研究新的固定相和高性能的毛细管色谱柱之外,主要在全二维气相色谱(GC×GC)、快速GC、便携式GC仪和微型GC仪几个方面。近几年新研究的GC固定相主要集中在常温离子液体和各种环糊精的衍生物。现在GC研究者趋向于使用商品化的GC毛细管柱,而商品化的GC毛细管柱应用最多的是以含5%苯基的聚甲基硅氧烷为固定相的色谱柱。GC×GC发展迅猛,特别是关于调制器的研究,已开发出十多种调制模式,并广泛地应用于各个领域。为了适应大量样品的分析和现场分析,研究和开发了多种快速GC方法和仪器以及便携式GC仪。为了仪器的小型化和专属性检测,μGC仪的研究也稳步地发展起来。  相似文献   

3.
Gas chromatography (GC), low-voltage mass spectrometry (LV MS), and gas chromatography/mass spectrometry (GC/MS) have been used for detecting polycyclic aromatic hydrocarbons (PAH) of molecular weight between 300 and 402 in airborne particulate matter. Nearly 200 high molecular PAH separated by fused silica capillary columns could be characterized by their El mass spectra. The lack of reference substances precluded further structure elucidation.  相似文献   

4.
小鼠血清中内源性代谢物的GC/TOF-MS分析   总被引:1,自引:0,他引:1  
采用气相色谱/飞行时间质谱(GC/TOF-MS)联用仪建立了小鼠血清的代谢组学分析方法. 通过对硅烷化试剂的优化和去卷积分析, 共检测到269个峰, 其中相似度在800以上的代谢产物有46个; 以核糖醇为内标, 任意选取18种内源性代谢产物考察此方法的精密度和稳定性, 并通过14种标准氨基酸的混标溶液进行定量分析考察本方法的线性关系. 结果表明, 14种氨基酸在2.78~113.20 ng/ SymbolmA@ L浓度范围内线性关系良好; 18种内源性代谢产物的变异系数均在15%以内, 具有较好的稳定性; 并利用8种标准单糖, 通过肟化反应解决了糖在多个位置出峰的难点. 该方法可用于代谢组学研究, 并通过相关数据处理找出生物标志物, 为疾病诊断提供了新的思路.  相似文献   

5.
《Analytical letters》2012,45(13):2231-2245
Abstract

A rapid and reliable analytical method, at trace level concentration was developed and validated for monitoring polychlorinated biphenyls (PCBs) in Jordanian surface water. The method combines the advantage of liquid extraction together with gas chromatography‐mass spectrometry (GC/MS) and gas chromatography‐electron capture detector (GC/ECD). The performance of the method was evaluated by analyzing certified reference material (CRM) of the analytes and applied on real water samples collected from different sites in Jordan. A mixture of 60∶40 dichloromethan‐petroleum ether was chosen as a convenient binary solvent for liquid–liquid extraction. The GC conditions for GC/MS were optimized using He as a carrier gas, temperature programming, and chlorpropham as an internal standard (IS).

The conditions for GC/ECD were performed using N2 gas and a temperature program from 160 to 280°C with different increasing rates. The method of GC/MS in the selective ion mode (SIM) gave linear relationships for all PCBs tested between 0.60–6.0 µg/l with R 2=0.9934 (n=7×18). Recoveries from spiked water samples ranged between 87.6 and 91.4%. The mean accuracy and precision obtained were 4.9% and 2.16%, respectively. The mean of detection limit was 0.14±0.04 µg/l. In GC/ECD, linear relationships for all PCBs examined over the range of 0.3–2.4 µg/l was verified as characterized by a linear regression equation and correlation coefficient, R 2=0.9915 (n=12). The average precision and accuracy were 4.86% and 5.21%, respectively. Analyses results clarified that none of the examined Jordanian water samples contained any of the searched for PCBs within the detection limit achieved.  相似文献   

6.
采用GC/MS法检测出邻氰堪苄基氯中的杂质组分,并使用萘做内标物进行气相色谱法对邻氰堪苄基氯的定量检测。  相似文献   

7.
An integrated gas chromatography/Fourier transform infrared spectrometry (GC/FT-IR) system developed for the analysis of environmental pollutants is described. The versatility of the system allows the utilization of many different techniques of sample introduction and manipulation during analysis. The sample can be introduced by direct injection or thermal desorption from an adsorbent cartridge, and can then be separated on one of two capillary columns and detected by FT-IR or an FID. Cold traps and collection cartridges incorporated in the system permit recovery and additional fractionation of samples. Recovered sample and sample fractions can then be re-analyzed by GC/FT-IR or subsequently analyzed by GC/MS or other methods.  相似文献   

8.
This study describes the use of high performance liquid chromatography (HPLC) and capillary gas chromatography/mass spectrometry (GC/MS) in the characterization of polar glucuronide conjugates of doxylamine and their subsequent aglycones following deconjugation. Rat urinary extracts which contained doxylamine and both nonconjugated and conjugated doxylamine metabolites, were examined by HPLC before and after incubation with rat intestinal microflora. The subsequent deconjugated urinary metabolites and the nonconjugated products remaining in the urinary extracts were then isolated, acetylated, and assayed by GC/MS. Incubation with the intestinal microflora indicated that anaerobic bacteria were capable of effecting hydrolytic cleavage of these polar O-glucuronide metabolites of doxylamine and its demethylated products to their subsequent aglycones. GC/MS analysis was performed using a fused silica DB-5 GC column and was utilized for the identification of these deconjugated metabolites.  相似文献   

9.
Comprehensive two-dimensional gas chromatography coupled with mass spectrometric detection (GC × GC/MS) is a three-dimensional analytical method. In its application to petroleum analysis, the high peak capacity of GC × GC produced chromatographic resolution of over 750 peaks from a marine diesel fuel. The MS detector provided a full-scan mass spectrum for each resolved peak. The integration of an MS detector with GC × GC provides increased capability to identify minor components, determine members of homologous series, and characterize ordered peak patterns of related components that are visible in the GC × GC chromatogram.  相似文献   

10.
Summary A method for determination of the composition of the light oil fractions in high-temperature coal tar by means of distillation, followed by gas chromatography on a crosslinked fused-silica, capillary column coated with optimum amount of stationary phase and identification by capillary gas chromatography/Fourier transform infrared spectrometry combined with GC retention indices (GC/FTIR-RI) is described. This method was effectively used to identify complex mixture such as coal tar without any standard samples, especially, adapted for isomeric compounds. More than 60 and 50 compounds were also separated and identified respectively in light oil fractions. This shows the capability of the capillary GC/FTIR combined with GC retention indices to identify isomers not accomplished by GC/MS.  相似文献   

11.
Narrow-bore column liquid chromatography coupled on-line with capillary gas chromatography (LC/GC) is used for the determination of polychlorinated biphenyls (PCBs) in sediment via a heart-cutting technique. This method is compared with a method in which two off-line column clean-up steps are used with subsequent analysis by capillary gas chromatography. For the LC/GC analysis the recovery of PCBs was 90–100%. For two sediment samples from the river Meuse the LC/GC and the other, more laborious method showed good agreement.  相似文献   

12.
Comprehensive two-dimensional gas chromatography with isotope-dilution time-of-flight mass spectrometry (GC × GC-IDTOFMS) was used to measure polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofuran (PCDF), and coplanar polychlorinated biphenyl (cPCB) concentrations in ash, sediment, vegetation, and fish samples. The GC × GC capability was achieved by using a quad jet, dual stage, thermal modulator. Zone compression of the GC peaks from modulation resulted in a significant increase of the signal intensity over classical GC-IDTOFMS. The GC × GC column set used an Rtx-Dioxin 2 phase as the first dimension (1D) and an Rtx-500 as the second dimension (2D). The chromatographic separation of the 17 PCDD/Fs and the 4 cPCBs was attained in 1D except for 2,3,7,8-TCDD and CB126 for which deconvoluted ion currents (DIC) were required to be reported separately. The Rtx-500 phase separated the bulk matrix interfering compounds from the target analytes in 2D. The instrumental limit of detection (iLODs) was 0.5 pg for 2,3,7,8-TCDD. The calibration curves showed good correlation coefficients for all the compounds investigated in the concentration range of 0.5–200 pg. GC × GC-IDTOFMS results compared favorably to those from conventional isotope-dilution one-dimensional gas chromatography-high resolution mass spectrometry (GC-IDHRMS). The comprehensive mass analysis of the TOFMS further permitted the identification of other contaminants of concern in the samples.  相似文献   

13.
Summary Polycyclic aromatic hydrocarbons (PAH) today are ubiquitous detectable constituents of recent sediments. The compounds are adsorbed on particulate emissions and are thus transferred to the environment. To date the analysis of PAH in sediments, dust samples and plant material is based mainly on the application of solvent-extraction methods followed by liquid chromatography and/or gas chromatographic separation of the extracts.An alternative approach for the analysis of PAH in solid samples such as coal, sediments, dust samples and plant waxes is shown in this contribution. A commercially available device for the analysis of volatile compounds present in solid matter is connected on-line to a GC/MS system. The device enables the thermal desorption of hydrocarbons at a temperature of 320°C. Subsequently, the hydrocarbons trapped on the initial part of the capillary column are analyzed by GC/MS. The application of mass chromatography provides the possibility of detection and quantitation of PAH in complex mixtures even when they coelute with other compounds. The sample amount required varies between 1 and 10 mg depending on the hydrocarbon content.  相似文献   

14.
The writer of this review published in 1978 a three‐part article on two‐dimensional gas chromatography in the first three issues of this journal [1]. The review was written at a time when capillary column GC was still in its infancy. Commercial columns were (essentially) unavailable and sample introduction into capillary columns was done exclusively in the split mode. Two‐dimensional separations were explored in only a few laboratories. The limitations of capillary column technology made this exercise rather difficult. The introduction of fused silica capillary columns in the early eighties drastically changed the landscape in which gas chromatography was practiced. It took the chromatographic community just a few years to convert from packed columns to capillary columns. Instrumentation and accessories specifically designed for capillary column use came onto the market. This writer had great hopes that the revolution in capillary column GC would be mirrored in the development of instrumentation for Two‐Dimensional Gas Chromatography. This never materialized. On the contrary, tentative steps taken by a few manufacturers and suppliers of chromatographic equipment fizzled out. It was perhaps the introduction of relatively inexpensive and user friendly GC/MS instrumentation, in combination with nearly indestructible fused silica capillary columns that took away the incentive to develop commercially viable Two‐Dimensional Gas Chromatography. Much of the thinking went like this: why insist on good chromatography if mass spectrometry can do the job without the need of complete separation. Some progress in the further development of conventional Two‐Dimensional Gas Chromatography has certainly been made over the last 20 years but there has not been a great deal of excitement. Applications have also been relatively sparse and they are limited to just a few areas. Science does not remain static and chromatography is no exception. Progress in gas chromatography is driven by new technology and ideas. Substantial improvements in two‐dimensional GC were not forthcoming until Phillips and his research group introduced and implemented an entirely new form of Two‐Dimensional Gas Chromatography, called comprehensive GC×GC. This breakthrough occurred only in 1991 [2]. It does take some time before scientists change attitudes and habits. There is always a time lag between the introduction of new technology and its general acceptance. The public's attitude toward comprehensive Two‐Dimensional Gas Chromatography is probably no exception. The number of scientists who are actively pursuing this new branch of gas chromatography is still very small. It is often a single individual who carries the torch. J.B. Phillips' name is synonymous with comprehensive Two‐Dimensional Gas Chromatography. He is not only its inventor and proponent but his fertile mind has initiated research in other related areas. Sadly, he passed aware shortly before this review was written. This contribution is dedicated to his memory.  相似文献   

15.
The applicability of comprehensive two-dimensional gas chromatography (GC×GC) for flavonoids analysis was investigated by separation and identification of flavonoids in standards, and a complex matrix natural sample. The modulation temperature was optimized to achieve the best separation and signal enhancement. The separation pattern of trimethylsilyl (TMS) derivatives of flavonoids was compared on two complementary column sets. Whilst the BPX5/BPX50 (NP/P) column set offers better overall separation, BPX50/BPX5 (P/NP) provides better peak shape and sensitivity. Comparison of the identification power of GC×GC-TOFMS against both the NIST05 MS library and a laboratory (created in-house) TOFMS library was carried out on a flavonoid mixture. The basic retention index information on high-performance capillary columns with a non-polar stationary phase was established and database of mass spectra of trimethylsilyl derivatives of flavonoids was compiled. TOFMS coupled to GC×GC enabled satisfactory identification of flavonoids in complex matrix samples at their LOD over a range of 0.5-10 μg/mL. Detection of all compounds was based on full-scan mass spectra and for each compound a characteristic ion was chosen for further quantification. This study shows that GC×GC-TOFMS yields high specificity for flavonoids derived from real natural samples, dark chocolate, propolis, and chrysanthemum.  相似文献   

16.
A software program was developed to enable the quantification of the complex 3D-data sets as produced by GC×GC. Using this software, it was demonstrated that the detectability limit of GC×GC in our study is 18 times better than that of ‘normal’ capillary gas chromatography (CGC). This enhancement is due to the signal increase produced by the thermal modulation effect. The relative standard deviation of 0.9% as measured on a test mixture was excellent. Furthermore, a comparison was made for the group-type separation of heavy gas oils between the hyphenation of LC and GC (LC-GC) and GC×GC. Although these separations are different in nature, the agreement of the results of both methods was very good. The results of GC×GC may even be more accurate, since, different from CGC, even in the most complex chromatograms the baseline in the second dimension chromatograms is always present.  相似文献   

17.
The analysis of solvents for both purity and component identifications is routinely performed by gas chromatography (GC). Coupling it with the latest FT-IR systems results in a technique which yields ppm sensitivity and excellent library search results.  相似文献   

18.
用毛细管GC/MS和GC/FTIR研究挥发油的化学成分   总被引:3,自引:0,他引:3  
本文用毛细管GC/MS和GC/FTIR对异叶青兰和鼠曲草两种植物挥发油的化学成分进行了研究,讨论了两种方法分析挥发油化学成分的优点和局限性。  相似文献   

19.
王琳琳  徐徐  陈小鹏  孙文静  童张法 《色谱》2007,25(3):413-417
采用气相色谱-质谱技术对松脂的催化歧化新工艺的反应产物进行分析,共分离出45个峰,鉴定出其中的38个化合物,并发现松脂歧化产物中歧化松节油的主要成分为对伞花烃,含量为16.26%;歧化松香的主要成分为脱氢枞酸和氢化树脂酸,其含量分别为41.58%和21.43%。在此基础上对松脂歧化反应过程进行了初步探讨,认为松脂原料中的酸性物质发生分子间氢转移反应,萜烯烃的存在促进了脱氢反应的进行;在树脂酸提供的酸性环境下松脂原料中中性油的主要成分双环单萜烯发生开环异构形成单环单萜烯,单环单萜烯再进行催化脱氢转化为对伞花烃。分析结果表明,直接以松脂为原料进行催化歧化反应可同时获得特级歧化松香和高含量的对伞花烃。  相似文献   

20.
红景天挥发油的GC/MS/DS和GC/IR/DS研究   总被引:1,自引:0,他引:1  
红景天挥发油的GC/MS/DS和GC/IR/DS研究阎吉昌,张宏徐少敏卫永弟,阎雪(东北师范大学测试中心,长春,130024)(吉林省石油化工研究院,白求恩医科大学)关键词红景天,色谱/质谱,色谱/红外,复杂有机混合物应用色谱/质谱/计算机(GC/M...  相似文献   