首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary A novel method of separating and detecting trace aluminum by capillary zone electrophoresis is described. Aluminum is reacted with lumogallion [4-chloro-3-(2,4-dihydroxyphenylazo)-2-hydroxybenzen-1-sulphonic acid] so that the complex can be selectively and sensitively detected by a laser-induced fluorescence detector after capillary electrophoretic separation. Using the proposed method, limits of detection in the sub parts per billion range are achieved. The technique is applied to the determination of aluminum in human serum.  相似文献   

2.
高效液相色谱荧光测定及质谱鉴定分析血清中胆汁酸   总被引:1,自引:0,他引:1  
利用新型荧光试剂1,2-苯并-3,4-二氢咔唑-9-乙基苯磺酸酯(BDEBS)作柱前衍生化试剂,在EclipseXDB-C8色谱柱上,采用梯度洗脱对10种胆汁酸(BAs)荧光衍生物进行了优化分离。95℃下在二甲基亚砜(DMSO)溶剂中以柠檬酸钾作催化剂,衍生反应35min后获得稳定的荧光产物,衍生反应完全。荧光激发和发射波长分别为λex=333nm,λem=390nm。采用大气压化学电离源(APCISource)正离子模式,实现了血清中胆汁酸的定性测定。分析物的定量测定采用荧光法进行。线性回归系数均在0.9996以上,检出限为22.36~44.57×10-15mol。  相似文献   

3.
Reaction of amino acids with N-methyl-N-(tert-butyldimethylsilyl)trifluoroaceamide (MTbSTFA) in acetonitrile affords good yields of amino acid derivatives with excellent gas chromatographic and mass spectrometric properties. The single-step derivatization procedure is highly reproducible. The TBDMS amino acids are stable at room temperature for at least three days. Only a single peak is observed for each amino acid. The procedure allows simultaneous analysis of asparagine and glutamine together with other serum amino acids. Separation is achieved on a borosilicate glass capillary coated with OV-1. The mass spectra of the TBDMS amino acids possess characteristic diagnostic ions. These properties were used in the sensitive detection by GC-MS and SIM-GC-MS of GABA and pipecolic acid in the serum of a newborn suspected of a Zellweger-type syndrome, which could not be detected by other methods.  相似文献   

4.
Trans-fatty acids are unsaturated fatty acids that are considered to have health risks. 1,3,5,7-Tetramethyl-8-butyrethylenediamine-difluoroboradiaza-s-indacene is a highly sensitive fluorescent labeling reagent for carboxylic acids developed by our lab. In this study, using this precolumn fluorescent derivatization reagent, a rapid and accurate high-performance liquid chromatography with fluorescence detection method was developed for the determination of two trans-fatty acids in food samples. Under the optimized derivative conditions, two trans-fatty acids were tagged with the fluorescent labeling reagent in the presence of 1-ethyl-3-(3-dimethyl-aminopropyl) carbodiimide at 25°C for 30 min. Then, the baseline separation of trans- and cis-fatty acids and their saturated fatty acid with similar structures was achieved with less interference using a reversed-phased C18 column with isocratic elution in 14 min. With fluorescence detection at λexem = 490 /510 nm, the linear range of the TFAs was 1.0-200 nM with low detection limits in the range of 0.1–0.2 nM (signal-to-noise ratio = 3). In addition, the proposed approach was successfully applied for the detection of trans-fatty acids in food samples, and the recoveries using this method ranged from 96.02 to 109.22% with low relative standard deviations of 1.2–4.3% (= 6).  相似文献   

5.
T. Takeuchi  T. Miwa 《Chromatographia》1995,40(3-4):159-162
Summary The effects of acetonitrile and bovine serum albumin (BSA) concentrations on the signal intensity and retention behavior of dansylamino acids have been examined by using -cyclodextrin-bonded silica gel as the stationary phase in microcolumn liquid chromatography. Fluorescence intensities of dansylamino acids were enhanced by BSA as a mobile phase additive, e.g., detection limits of dansyl derivatives of L-Ala and L-Phe were improved by a factor of 12–18.  相似文献   

6.
Coquet  A.  Haerdi  W.  Degli Agosti  R.  Veuthey  J. -L. 《Chromatographia》1994,38(1-2):12-16
Summary A method for the determination of reducing sugars such as fructose and glucose and nonreducing sugar such as sucrose by high performance liquid chromatography followed by an acidic hydrolysis and a derivatization with benzamidine has been developed. After separation of sugars on a gel column packed with a polymer-based cation exchange material (Sugar-Pak I, Waters-Millipore), the sucrose is first hydrolysed in a solid phase reactor to convert it into reducing subunits. A post-column fluorigenic reaction with benzamidine under alkaline condition allows the selective determination of both natural and converted reducing carbohydrates.This procedure has proven to be selective (fluorigenic detection) and highly sensitive (allowing detection as little as picomoles amounts), reproducible and linear over a broad range of concentrations: 5×10–4 to 1.0×10–2 M.The applicability of this method to natural matrices such as plant extracts and beverages is also described. The sugar content of a barley extract has been determined and compared with a specific enzymatic test. The determined sugar content of natural and commercial lemon juices as well as of Cola beverages has been compared with those found by the conventional LC refractive index analytical procedure. In all cases, the results were comparable and were within the experimental errors of the methods.  相似文献   

7.
Su P  Zhang XX  Wang YC  Chang WB 《Talanta》2003,60(5):969-975
A simple and sensitive capillary electrophoretic immunoassay (CEIA) was described for the determination of estriol (E3) in pregnant women's serum. The method was based on the competitive reaction of fluorescein-labeled E3 antigen and E3 with limited amounts of monoclonal antibody. The addition of the thermally reversible hydrogel, poly-N-iso propylacrylamide (pNIPA) in the buffer serving as a replaceable packing material, improved the reproducibility of the method. With laser-induced fluorescence detector (LIF), this method can be applied to determine E3 at concentrations lower to 31.6 pg ml−1. Recoveries from human steroid-free serum matrix were greater than 94% with relative standard deviation (R.S.D.) values less than 3.5%. Serum E3 levels of ten normal pregnant women were measured at the range of 10.2-15.6 ng ml−1.  相似文献   

8.
A high performance liquid chromatography (HPLC) method is described for the determination of agmatine, an endogenous neuromodulator. The method involves pre-column derivatization of the sample with a fluorescent tagging reagent, 7-fluoro-4-nitrobenzoxadiazole (NBD-F). The resulting agmatine derivative is stable and can be readily extracted into ethyl acetate at pH 8.5. The extraction enhances the quantification of low level agmatine because it eliminates chromatographic peaks caused by endogenous amino acids. The HPLC separation is carried out on a C8 reversed phase column and completed in less than 10 min. With laser-induced fluorescence (LIF) detection, the detection limit is 5×10−9 M agmatine. Method precision (coefficient of variation) is 5% for agmatine in human plasma at the sub-μM level. This method has been validated by determination of agmatine in biological samples including human plasma and rat brain and stomach tissues.  相似文献   

9.
Summary The profile of serum bile acids is a result of their liver metabolism and enterohepatic circulation.In the present work size exclusion chromatography is used for extraction of serum bile acids to optimize the methodology for analyzing serum bile acids by high resolution gas chromatography.Compared to other extraction methods like adsorption-[1–3] or reversed phase chromatography [4,5], this novel technique yielded a satisfactory recovery (75–104%) with high reproducibility. Therefore a reliable determination of serum bile acids is possible.  相似文献   

10.
Serotonin (5-hydroxytryptamine, 5-HT) plays vital roles in regulating gastrointestinal functions. Thus, the detection of 5-HT in the gastrointestinal tract is of great importance for biomedical research, medical diagnosis, and pharmaceutical therapy. This paper presents a simple, sensitive, and fast method for the quantification of luminally released serotonin in the feces and tissues of the rat proximal colon by means of capillary electrophoresis with laser-induced fluorescence detection. 5-Carboxyfluorescein N-succinimidyl ester was used for precolumn derivatization of serotonin. The optimal separation and detection conditions were obtained with an electrophoretic buffer containing 60 mM borate (pH 8.90) and an air-cooled argon-ion laser (excitation at 488 nm, emission at 520 nm). The serotonin concentrations in the feces and tissues of proximal colons were analyzed with this method, and the average values of serotonin in the feces samples were 1.951 ± 0.446 ng/mg (male) and 2.095 ± 0.533 ng/mg (female) and 1.397 ± 0.267 ng/mg in rat proximal colon tissues. The results demonstrate that this method can accurately determine luminally released 5-HT in rats.  相似文献   

11.
This work described a sensitive method for determination of metoprolol in rabbit plasma.The method involved purification by ultrafiltration,derivatization with fluorescein isothiocyanate,determination by capillary electrophoresis(CE) coupled with laser-induced fluorescence(LIF) detector.Other components in plasma including a variety of amino acids and proteins did not interfere with the determination of metoprolol in experimental condition.The assay had a wide range(2.0-500 ng/mL) of linearity and a detection limit of 0.8 ng/mL.The intra- and inter-day precisions were satisfactory with relative standard deviation(RSD) less than 10.0%and accuracy within 10.0%.This method was successfully applied to pharmacokinetic study of metoprolol in rabbit blood.  相似文献   

12.
毛细管液相色谱法分离植物内源激素   总被引:2,自引:0,他引:2  
建立了毛细管液相色谱法(CLC)同时分离测定4种植物内源激素的方法.采用硅胶基质ODS整体柱(27 cm×100 μm i.d.)作为分离柱,以带有光程为3 mm的光纤检测池的紫外检测器作为检测手段,在室温下以含10 mmol/L乙酸(pH 3.0)的V(甲醇):V(水)=35:65为流动相,以0.6 μL/min的流速进行等度洗脱.采用溶剂梯度效应和扩展光程的检测池来提高检测灵敏度,该方法测定4种植物内源激素的检出限(S/N=3)在27.7~196.1 ng/mL之间,峰面积和保留时间的相对标准偏差(RSD)小于2.8%.方法已用于不同种类玉米样品的测定.  相似文献   

13.
Summary A rapid and sensitive method for the simultaneous determination of primary amino acids in apple is described. After sample preparation, amino acids were derivatized with o-phthaldialdehyde/2-mercaptoethanol and separated on a reversed phase column with a gradient of phosphate buffer-tetrahydrofuran-methanol as the mobile phase. Detection was carried out with a fluorescence detector at excitation and emission wavelengths of 340 nm and 425 nm respectively. Recovery studies showed good results for all substances (91–109%) (with coefficients of variation ranging, from 0.1 to 9.0%). This method was applied to the monitoring of amino acids during the ripening of apples.  相似文献   

14.
H. Hosotsubo 《Chromatographia》1988,25(10):887-890
Summary A high-performance liquid chromatographic method for the analysis of thiopental in 100l of human serum or plasma is described. The procedure involves protein precipitation with acetonitrile. The supernatant is directly injected into a chromatograph containing a reversed-phase CLC-ODS (Shimadzu) column. A 5050 (v/v) mixture of water-acetonitrile, at a flow-rate of 1.0ml/min is used as the mobile phase. Detection is carried out ata wavelength of 280nm. Total analysis time per sample is 10min. The assay was found to be linear in the range of 0.1 to 120g/ml. Reproducibility was good, with intra-assay coefficients of variation from 1.780 to 3.208% and inter-assay coefficients of variation from 3.241 to 4.860%. The absolute recoveries were 97.4 to 101,4%. Other drugs were tested for potential interference with the assay, but none was found.  相似文献   

15.
高效液相色谱荧光检测法测定药物中的氯乙酰氯   总被引:1,自引:0,他引:1  
建立测定药物中氯乙酰氯含量的高效液相色谱–荧光检测方法。以吖啶酮乙酰肼为荧光标记试剂,对氯乙酰氯进行柱前衍生。在室温下反应15 min,衍生产率达到最大。衍生溶液在XDB–C18柱上,以水和乙腈为流动相进行分析,激发波长和发射波长分别为255 nm和429 nm。氯乙酰氯浓度在1~1 000 nmol/L范围内与色谱峰面积具有良好的线性关系,线性相关系数r=0.999 9。方法的检出限为0.35 nmol/L,仪器精密度和方法精密度分别为0.52%和0.67%(n=6)。样品加标回收率为92.5%~95.6%。该方法简单、准确,精密度良好,可用于测定药物中氯乙酰氯的残留量。  相似文献   

16.
In this study, we developed a novel assay that simultaneously detects multiple miRNAs (microRNAs) within a single capillary by combining a tandem adenosine-tailed DNA bridge-assisted splinted ligation with denaturing capillary gel electrophoresis with laser-induced fluorescence. This proposed method not only represents a significant improvement in resolution but also allows for the detection of multiple miRNAs within a single capillary based on the length differences of specified target bridge DNA. The assay's linear range covers three orders of magnitude (1.0 nM to 1.0 pM) with a limit of detection (S/N=3) as low as 190 fM (2.5 zmol). Five miRNAs of Epstein-Barr virus (EBV) were also detected in EBV-infected nasopharyngeal carcinoma cells, while they did not appear in non-virus infected cells. Moreover, the electropherogram indicated that the screening of isomiRs (isomer of miRNA) of BART2 by CE-LIF is feasible by our proposed method. The developed electrophoresis-based method for miRNA detection is fast, amplification-free, multiplexed and cost-effective, making it potentially applicable to large-scale screening of isomiRs.  相似文献   

17.
建立了准确测定血清中尿酸含量的高效液相色谱方法,血清样品利用乙腈沉淀蛋白,过滤后直接进样测定。所采用的色谱柱为Inertsil ODS-SP(4.6mm i.d.×250 mm,5μm),柱温25℃,流动相体系为10 mmol/L乙酸铵(pH 4.5),流速为1.0 mL/min,紫外检测波长为280 nm。线性范围12.5~150μg/g,回收率为99.79%~100.5%。本文采用乙酸铵缓冲体系,对环境的污染小,同时也为建立液相色谱-质谱法测定尿酸奠定了良好的基础。  相似文献   

18.
建立了大熊猫血清中18种游离氨基酸的反相高效液相色谱分析方法.血清样品经HPO3沉淀蛋白后,在弱碱性条件(pH 9.0)下游离氨基酸与2,4-二硝基氯苯在90℃水浴中避光反应1.5 h,生成具有紫外吸收的衍生物,用反相C18柱分离,紫外检测器检测,内标法定量.18种氨基酸的工作曲线的相关系数范围为0.9951~0.9999;相对标准偏差为1.4%~4.7%;检出限为0.20~7.72μg/mL;加标回收率为65.9%~118%.  相似文献   

19.
Jiang Jiang 《Talanta》2007,72(1):113-118
An enrichment method for the herbicide glyphosate is presented based on ion exchange solid phase extraction (SPE) technique. A 200-μl micro-pipette tip packed with 50 mg of Bio-Rad AG1-X8 anion exchanger beads was used for offline extraction of glyphosate from 50 ml of spiked river water sample. The retained glyphosate was eluted with 10 mM HCl and then converted quantitatively to the corresponding amine (glycine) using hypochlorite. Subsequent fluorescent labeling using naphthalene-2,3-dicarboxaldehyde (NDA)-cyanide allowed micellar electrokinetic chromatography (MEKC) separation and laser-induced fluorescence detection (LIF) with a violet diode laser. Optimization of the sample clean-up, extraction, elution, conversion and labeling steps enabled analysis of glyphosate in river water in the nanomolar range. Detection limits were 0.04 nM glyphosate in standards and 1.6 nM in spiked river.  相似文献   

20.
This report describes a convenient means of reducing the complex matrix which is responsible for interference during gas chromatographic determination of amino acids in urine. The pre-chromatographic clean-up employs the principle of solid phase extraction using bonded silica incorporating cation exchange groups. This approach avoids the detrimental effects on amino acid recoveries associated with resin-based cation exchangers. In spite of significant reduction in the complexity of chromatograms, only the high efficiency and resolving power offered by the analytical capillary column (e. g. fused silica open tubular, FSOT) is sufficient for quantitative and analysis of amino acids in urine. Reproducibility data from the complete procedure are determined, coefficients of variation (CV) for most amino acids being better than 5% with a mean recovery of 96%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号