 共查询到20条相似文献,搜索用时 46 毫秒
1.
Pulsed flow modulation (PFM) is based on higher flow rate time compression of the first GC column effluent, which prior to the injection into the second column is stored for a few seconds in a standard fused silica wide bore transfer line. We constructed the PFM device with two standard 1/16 in. brass compression fittings with the insertion of the two columns inside the wide bore 0.53 mm i.d. fused silica storage transfer line for the elimination of dead volumes. This simple arrangement provides a combination of flexibility in the length of the sample storage transfer line hence comprehensive two-dimensional gas chromatography (GC x GC) cycle time, inert sample path and full elimination of cooling gas consumption. A record short second column injection time of 20 ms is demonstrated. Practical injection times are the sample collection time (such as 4s) divided by the second to first column flow rate ratio (such as 20/0.7), which is typically around 150 ms. Due to the low cost of the device it can also be considered for use with non comprehensive time segmented GC x GC to remove a few accidental coelutions. PFM-GCxGC excels with high second column capacity due to the use of 0.32 mm i.d. columns with high flow rates as the second dimension GC x GC column. As a result, PFM-GCxGC can have up to two orders of magnitude higher second column sample capacity and linear dynamic range for improved reduction of adverse matrix interference effects due to column overloading.  相似文献   

2.
The application of vacuum GC has several advantages over pressurized GC. One of the key characteristics is that the optimal gas velocity is very high. Combined with short capillary columns of wide internal diameter, this results in short analysis times using standard GC‐MS equipment. To make vacuum GC possible using a GC‐MS system, a restriction must be positioned at the injection side of the column. This restriction is usually made of deactivated 0.1 mm i.d. fused‐silica tubing which is coupled to the analytical column. Such restrictions will work, but practical challenges are found in coupling, reducing dead volume and robustness. A new way of making restrictions is by incorporating the restriction into the injection port. Using well‐defined short pieces of fused silica with internal diameter of 0.025 mm, one can make a restriction using a Press‐Tight® type connector, and position this inside the injection port. By doing this, the restriction is very short and at high temperature all the time. Activity plays a minimal role, and also leaks will not be an issue as the coupling is in 100% inert gas. Data obtained using this concept is promising as vacuum GC becomes easier and more robust.  相似文献   

3.
气相色谱-质谱法分析橡苔浸膏中的挥发性化学成分   总被引:1,自引:1,他引:0  
高芸  刘百战  朱晓兰  时亮  陈加林  宫梅  张龙根 《色谱》2000,18(3):251-253
 用挥发油提取器提取橡苔浸膏中的挥发油,利用气相色谱-质谱法(GC-MS)分析了其中的化学成分,采用GC峰面积归一化法定量,鉴定出24种化合物,共占挥发油总量的83%以上  相似文献   

4.
The technique of choice for many types of forensic drug confirmations is gas chromatography/mass spectrometry (GC/MS). Significant amounts of analytical time can be involved in a GC/MS run. The use of a 0.1 mm i.d. fused silica capillary column with hydrogen carrier gas can significantly increase the speed of an analysis without sacrificing resolution. Nanogram levels of underivatized drugs, from amphetamine to strychnine, can be eluted in less than twelve minutes. The multitasking system permits data acquisition, while performing data reduction on the previous run.  相似文献   

5.
气提浓缩仪分析水中痕量挥发性有机物研究   总被引:1,自引:0,他引:1  
本文描述了气提浓缩仪的设计及操作程序用于对水中痕量挥发性有机物的测定。分析物被气提吸附于TenaxGC柱上,然后直接脱附到毛细管气相色谱柱上进行分析,并用FID或MS鉴定。本文除对色谱条件进行优化外,对气提时间和脱附温度等分析操作条件也进行了研究。检测下限为0.01-0.30PPb,峰面积检测精度优于6.9%,对16种化合物的回收率优于74%。  相似文献   

6.
Polymeric polyimide capillary tubing, both uncoated and coated with stationary phases of two polarities, is explored for use as capillary columns for gas chromatography (GC). These glass-free polyimide columns are flexible and their small winding diameter of less than a cm around a solid support makes them compatible for potential use in portable GC instruments. Polyimide columns with dimensions of 0.32 mm i.d. × 3 m are cleaned, annealed at 300°C, and coated using the static method with phenylmethylsilicone (PMS). Separations of volatile organics are investigated isothermally on duplicate sets of polyimide columns by GC with a flame ionization detector using split injection. Unlike the uncoated ones, the coated polyimide columns successfully separate Grob test mix classes of alkanes, amines, and fatty acid methyl esters. The relative standard deviations for retention time and peak area are 0.5 and 2.5 , respectively. With the 3 m PMS-coated column connected to a retention gap to permit operation at its optimum flow rate of 30 cm/s, a plate count of 3200 or plate height of 1 mm is possible. Lack of retention and tailing peaks are evident for the polyimide polymer capillary columns as compared to that of a 3 m commercial cross-linked PMS fused silica capillary. However, headspace analyses of an aromatic hydrocarbon mix and a Clearcoat automotive paint sample are viable applications on the PMS polyimide polymer column.  相似文献   

7.
Acrolein, acrylonitrile, volatile organics, base/neutral extractables, acid extractables, and pesticide fraction organics are analyzed in a single chromatographic run. This is accomplished by injecting the extractable organics, then applying a cryogenic focus to the front of the column, and desorbing the volatile components. The column utilized for this procedure is a fused silica open tubular (FSOT) column coated with the liquid phase SE-54. Minimum detection limits of this procedure by electron impact GC/MS are shown to be? 1 μg/liter in tests conducted on actual water samples.  相似文献   

8.
A vacuum-pump-operated backflush system has been developed for applications involving high-speed, repetitive GC analysis of gas streams containing ppm and ppb levels of organic vapor. The system uses an injector capable of cryofocusing and a relatively short length of 0.25-mm i.d. fused silica column for the separation of relatively simple mixtures of volatile compounds. Analysis times typically are in the 5–10 s range, and backflush times are in the 2–5 s range. Gases from the flame ionization detector are used as the backflush carrier gas, and no modification of the detector is necessary. A procedure is described which allows the average gas velocity to be measured during backflush operation. The minimum backflush time is directly proportional to the analysis time and to the square of the column length, making this system most useful with short columns and short analysis times.  相似文献   

9.
Hold-up times and peak widths have been measured in long fused silica GC capillary columns at high temperature with helium as the carrier gas. The results lead to the conclusion that the helium permeates through the column walls. The conventional Poiseuille theory of carrier gas flow has been extended to include this phenomenon. The resulting “loss modified Poiseuille” model, which uses literature values for the permeability of fused silica to helium, has been used to simulate the observed behavior. Good agreement between simulation and experiment validates the model. Simulations have been used to explore the effect of column permeability on hold-up times, peak widths, and velocity profiles over a broad range of column geometries.  相似文献   

10.
采用改变相比/顶空气相色谱法测定了甲烷、乙炔、乙烯、乙烷和丙烷在变压器油中的分配常数。顶空瓶中的气体样品经石英毛细管送到气相色谱仪的六通进样阀样品管中,然后进行分离和定量。采用标准曲线法定量,通过测定5个不同相比时轻烃组分的顶空浓度,计算顶空浓度倒数与相比之间的线性回归方程,测定了20 ℃和50 ℃时烃类气体在变压器油中溶解气体的分配常数。除甲烷外,计算所得的分配常数与文献值基本吻合,油中溶解气体浓度的实验值与实际值之间的相对误差小于4.14%,表明用此方法可以测定不同温度下变压器油中溶解气体的分  相似文献   

11.
The performance characteristics of a portable GC instrument requiring no compressed gas supplies and using relatively lightweight transportable components for the analysis of volatile organic components in large-volume air samples are described. To avoid the need for compressed gas tanks, ambient air is used as the carrier gas, and a vacuum pump is used to pull the carrier gas and injected samples through the wall-coated capillary column and a photoionization detector (PID). At-column heating is used eliminating the need for a conventional oven. The fused silica column is wrapped with heater wire and sensor wire so that heating is provided directly at the column. A PID is used since it requires no external gas supplies and has high sensitivity for many compounds of interest in environmental air monitoring. In order to achieve detection limits in the ppb range, an online multibed preconcentrator containing beds of graphitized carbons and carbon molecular sieves is used. After sample collection, the flow direction through the preconcentrator is reversed, and the sample is thermally desorbed directly into the column. Decomposition of sensitive compounds during desorption is greater with air as the carrier gas than with hydrogen.  相似文献   

12.
Tan YL  Quanci JF 《Talanta》1985,32(7):577-578
A packed-column gas-chromatograph/mass-spectrometer (GC/MS), Hewlett-Packard 5982, was modified to accommodate fused silica capillary columns. The original GC/MS interface and chemical-ionization sample-line in the ion-source were changed to allow the end of a fused silica capillary column to enter the ion-chamber directly. For chemical-ionization operation, the reagent gas was brought into the MS through the direct-insertion probe port. The calibration compound was introduced through the electron-impact sample-inlet, which simplified the operation. The modified system yields higher sensitivity and more efficient separation, as well as simpler operation, without sacrificing any original instrument functions.  相似文献   

13.
The purge and trap (P&T) method of analysis has been interfaced with fused silica capillary column gas chromatography. This interfacing has been accomplished without splitting the P&T trap desorption carrier gas. Thus, 100% of the purged compounds are transferred to the column. The analytes are cryofocussed on the column using whole column cryotrapping (WCC) at ?80°C. The resulting P&T/WCC procedure is extremely well-suited to the analysis of trace purgeable aqueous organic compounds. Samples and standards containing a variety of aromatic standard compounds were analyzed. The standards included benzene, toluene, ethylbenzene, xylenes, C3-C4-benzenes, and naphthalene, as well as three P&T internal standard compounds. Chromatographic peak widths were uniformly less than 6 s at the base and excellent precision was obtained in the relative retention time data for all compounds. The chromatogram of a groundwater sample contaminated with aromatic gasoline compounds is also presented. Since P&T/WCC works well with fused silica capillary columns, the full sensitivity and chromatographic efficiency of capillary gas chromatography is made available to P&T analyses.  相似文献   

14.
A new liquid nitrogen (LN2) jet-based thermal modulator for performing comprehensive two-dimensional (2D) gas chromatographic (GC x GC) separations has been designed and constructed. Temperature measurements of the trapping zone, a segment of uncoated fused silica capillary, show that it can be cooled to -196 degrees C in about 300 ms. A film of liquid nitrogen develops on the outside of the trapping capillary even when the oven temperature is in excess of 200 degrees C. Compounds as volatile as propane can be trapped by the modulator and held for periods of at least 1 min without breakthrough. The peak widths for n-alkanes are on the order of 80 ms at half height after passing through an 80cm second dimension column. Repeated analysis of gasoline demonstrated excellent run-to-run reproducibility of the system.  相似文献   

15.
陈静  周宏英  李红兵  杨效和  杨军  傅宏祥  杨焱 《色谱》1999,17(2):221-222
α-(6-甲氧基-2-萘基)-乙醇在催化剂的作用下,与甲醇和CO发生羰基化反应,一步生成α-(6-甲氧基-2-萘基)丙酸甲酯(萘晋生申酯)。应用气相色谱-质谱联用技术,对这个反应过程中生成的各种化合物进行了分析,获得两个中间产物6-甲氧基萘乙烯和1-甲氧基-1-(6'-甲氧基-2'-萘基)乙烷的GC/MS数据资料,为推测该催化反应机理提供了可靠的依据。  相似文献   

16.
Novel monomeric and polymeric liquid crystalline compounds were synthesized as stationary phases for gas chromatography (GC) and supercritical fluid chromatography (SFC). Monomeric liquid crystalline compounds were used in packed column gas chromatography for the separation of isomeric aromatic compounds and insect sex pheromones. Liquid crystalline polymers possess long nematic ranges and a uniform coating was easily achieved in glass and fused silica capillaries, which could stand temperatures up to 250°C in GC and pressures of 200 MPa at 160°C in SFC. The columns provide excellent selectivity and resolution for fused ring aromatic compounds such as the isomers anthracene and phenanthrene or triphenylene and chrysene.  相似文献   

17.
A simple and rapid gas chromatographic (GC) method has been developed for the simultaneous determination of combinations of acetaminophen, phenylpropanolamine hydrochloride, guaifenesin, pseudoephedrine hydrochloride, caffeine, chlorpheniramine maleate, and dextromethorphan hydrobromide in cough and cold tablets and syrups. After extraction of the analyte with alkaline ethyl acetate, 2 microL extract was injected (splitting ratio of 50:1) into a gas chromatograph equipped with a CBP1-M25-025 fused silica capillary column (25 m x 0.22 mm; film thickness, 0.25 microm). The column temperature was held at 150 degrees C for 5 min, increased to 175 degrees C at 3 degrees C/min, and increased to 270 degreesC at 10 degrees C/min. The temperatures of the flame ionization detector and injector were maintained at 300 degrees C. The GC method is inexpensive, rapid, accurate, and precise, and thus it can be used for routine analysis of tablet and syrup preparations in quality control laboratories of pharmaceutical companies.  相似文献   

18.
山楂挥发性化合物的气相色谱-质谱分析   总被引:4,自引:0,他引:4  
陈凌云  谢笔钧  游铜锡 《色谱》1997,15(3):219-221
采用蒸馏-萃取法收集山楂果的挥发性化合物,通过气相色谱及气相色谱/质谱分析,鉴定了32种化合物,占总峰面积的61%~68%。其中主要的10种化合物是顺-3-己烯醇、顺-3-乙酸己烯酯、α-萜品醇、糠醛、己醇、乙酸己酯、壬醛、柠檬醛、3-戊烯-2-酮,反-2-癸烯醛等。  相似文献   

19.
A new phenyl-cyanopropyl polymethylsiloxane stationary phase, DB-1301, which can be crosslinked and bonded to the fused silica surface, has been synthesized. The phase composition was optimized for the separation of 18 volatile priority pollutants, selected from the so-called “purgables” list because of problems associated with their resolution. The composition of the stationary phase was based on theoretical considerations of binary phase mixtures and window diagram prediction. Columns coated with this stationary phase are compatible with atom selective detectors, such as the electron capture detector. A mixture of 18 volatile priority pollutants and a mixture of chlorinated pesticides were used as test probes on a prototype 30 m × 0.32 mm fused silica column, containing a 1.0 μm film of DB-1301.  相似文献   

20.
A multidimensional chromatography system with a packed fused silica Micro-LC column connected on-line with capillary gas chromatography is presented. The Micro-LC column is used for group separation. Whole peaks are injected into the capillary GC column via an on-column injector. The reproducibility of the proposed transfer system for polyaromatic hydrocarbons is 3% to 7% relative standard deviation. The potential of this on-line Micro-LC-GC system is demonstrated by the analyses of PAH's and of a complex light gasoline fraction.  相似文献   