首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
High-performance liquid chromatography (HPLC) coupled to atmospheric pressure chemical ionization (APCI) mass spectrometry was used for the separation and detection of amino acid and peptide enantiomers. With detection limits as low as 250 pg, 25 amino acids enantiomers were baseline resolved on a Chirobiotic T chiral stationary phase. APCI demonstrated an order of magnitude better sensitivity over electrospray ionization (ESI) for free amino acids and low molecular mass peptides at the high LC flow-rates necessary for rapid analysis. As the peptide chain length increased (peptides with M(r) > or = 300 Da), however, ESI proved to be the more ideal atmospheric pressure ionization source. A mobile phase consisting of 1% (w/w) ammonium trifluoroacetate in methanol and 0.1% (w/w) formic acid in water increased the sensitivity of the APCI method significantly. A step gradient was then used to separate simultaneously all 19 native protein amino acid enantiomers in less than 20 min using extracted ion chromatograms.  相似文献   

2.
《Analytical letters》2012,45(16):2514-2525
Reliable and sensitive chromatographic methods have been developed and applied to determine derivatized di- and tripeptides: aspartame, carnosine, glutathione, alanyl-glutamine, and γ-glutamyl-cysteine. Photodiode-array detection was used for dansyl-chloride derivatives, while fluorescent detection was carried out for orthophthaldialdehyde derivatized peptides to obtain higher sensitivity. The sensitivity and detection limits were determined and compared in order to select the most efficient analytical method. Transition metal complexes [zinc(II), cadmium(II), silver(I), and copper(II)] with cysteine containing peptides were also determined with ultraviolet-visible detection. The structural identification was carried out by the analysis of the mass-spectra recorded with an atmospheric pressure chemical ionization method in separate chromatographic experiments.  相似文献   

3.
The analysis of organic acids in complex mixtures by LC-MS can often prove challenging, especially due to the poor sensitivity of negative ionization mode required for detection of these compounds in their native (i.e., underivatized or untagged) form. These compounds have also been difficult to measure using supercritical fluid chromatography (SFC)-MS, a technique of growing importance for metabolomic analysis, with similar limitations based on negative ionization. In this report, the use of a high proton affinity N-(4-aminophenyl)piperidine derivatization tag is explored for the improvement of organic acid detection by SFC-MS. Four organic acids (lactic, succinic, malic, and citric acids) with varying numbers of carboxylate groups were derivatized with N-(4-aminophenyl)piperidine to achieve detection limits down to 0.5 ppb, with overall improvements in detection limit ranging from 25-to-2100-fold. The effect of the derivatization group on sensitivity, which increased by at least 200-fold for compounds that were detectable in their native form, and mass spectrometric detection are also described. Preliminary investigations into the separation of these derivatized compounds identified multiple stationary phases that could be used for complete separation of all four compounds by SFC. This derivatization technique provides an improved approach for the analysis of organic acids by SFC-MS, especially for those that are undetectable in their native form.  相似文献   

4.
A portable tandem mass spectrometer, capable of performing atmospheric pressure chemical ionization (APCI) using a direct atmospheric inlet, is applied to the real-time monitoring of toxic compounds in air. Analytes of interest include dimethyl methylphosphonate, arsine, benzene, toluene, pyridine and vinyl acetate. The detection, identification and quantification of organic and inorganic compounds in air is demonstrated using short analysis times (<5 seconds) with detection limits in the low ppb (v/v) levels and linear dynamic ranges of several orders of magnitude. Highly specific detection and identification is achieved, even when the analyte is a trace component in a complex mixture including such interferents as fuels, lubricants, and cleaners. The effects of environmental conditions, including temperature and humidity, are delineated. Receiver operating characteristic (ROC) curves are presented to show the trade-off between false positive and false negative detection rates. Tandem mass spectrometry based both on collision-induced dissociation and on selective atmospheric pressure ion/molecule reactions is also used to increase selectivity and sensitivity.  相似文献   

5.
The analytical hyphenation of micro-flow high-performance liquid chromatography (LC), with post-column liquid mixing and mass spectrometric detection (MS) was established to detect partially oxidized polycyclic aromatic hydrocarbons (oxy-PAHs) for low quantity samples. 100pmol injections of 30 reference standards could be detected in good sensitivity using either atmospheric pressure chemical ionization (APCI) and/or atmospheric pressure photoionization (APPI). The connected mass spectrometer was a single quadrupol analyzer realizing simultaneous registration of positive and negative ions in scan range width of 200 - 300Da. The ionization efficiency was compared using three ionization sources (incl. electrospray ionization (ESI)) for several oxy-PAHs. According to the mass spectra, the analytes behave differently in ionization properties. Ionization mechanism (e.g. deprotonated ions and electron captured ions) could be discussed with new inside views. Finally, the hyphenated system was applied to an exemplary aerosol extract and thus highlighting the expedient utilization of this downscaled method for real samples.  相似文献   

6.
Higashi T  Takido N  Shimada K 《The Analyst》2003,128(2):130-133
The detection and characterization of 20-oxosteroids in rat brains by liquid chromatography (LC)-electron capture atmospheric pressure chemical ionization (ECAPCI)-mass spectrometry (MS) is described. In the present method, oxosteroids were derivatized with a highly electron-affinitive reagent, 2-nitro-4-trifluoromethylphenylhydrazine, to convert them to the corresponding hydrazones. The derivatized steroids showed over 20-fold higher sensitivity in ECAPCI-MS than intact steroids measured in positive-APCI-MS. A brain sample was homogenized, purified with two disposable cartridges, derivatized and subjected to LC-ECAPCI-MS. Pregnenolone, progesterone, 5alpha-dihydroprogesterone, allopregnanolone and epiallopregnanolone were clearly detected with a 50 mg sample of the brain tissue.  相似文献   

7.
K Isoo  K Otsuka  S Terabe 《Electrophoresis》2001,22(16):3426-3432
An application study of sweeping, an on-line sample concentration technique, to micellar electrokinetic chromatography (MEKC) directly combined with mass spectrometry (MS) using an atmospheric pressure chemical ionization (APCI) interface, namely MEKC-APCI-MS, was investigated to enhance the concentration sensitivity for the analysis of environmental pollutants. Under a neutral condition, around 100-fold increase in the concentration sensitivity was achieved for several aromatic amines and alkyl phthalates as test samples by sweeping-MEKC-APCI-MS compared to conventional MEKC-APCI-MS, whereas under an acidic condition, 100 to 600-fold sensitivity enhancement was gained for similar solutes. Linearity of the corrected peak area obtained in the mass chromatogram against the sample concentration was examined for 3,4-dichloroaniline and diisopropyl phthalate (DIPP). The estimated limits of detection for 3,4-dichloroaniline and DIPP were 0.6 and 0.4 ppm, respectively, in terms of the injected sample concentration.  相似文献   

8.
The effect of nine different eluent compositions on the ionization efficiency of five flavonoids was studied using ion spray (IS), atmospheric pressure chemical ionization (APCI), and the novel atmospheric pressure photoionization (APPI), in positive and negative ion modes. The eluent composition had a great effect on the ionization efficiency, and the optimal ionization conditions were achieved in positive ion IS and APCI using 0.4% formic acid (pH 2.3) as a buffer, and in negative ion IS and APCI using ammonium acetate buffer adjusted to pH 4.0. For APPI work, the eluent of choice appeared to be a mixture of organic solvent and 5 mM aqueous ammonium acetate. The limits of detection (LODs) were determined in scan mode for the analytes by liquid chromatography/mass spectrometry using IS, APCI and APPI interfaces. The results show that negative ion IS with an eluent system consisting of acidic ammonium acetate buffer provides the best conditions for detection of flavonoids in mass spectrometry mode, their LODs being between 0.8 and 13 microM for an injection volume of 20 microl.  相似文献   

9.
Nguyen KT  Scapolla C  Di Carro M  Magi E 《Talanta》2011,85(5):2375-2384
Fast liquid chromatography coupled to triple-quadrupole tandem mass spectrometry was employed for the determination of six UV filters in seawater. The separation of the analytes was achieved in less than 5 min; polarity switching was used as four of the analytes were ionized in positive mode and the remaining two in negative mode. Two ionization sources were employed and compared: atmospheric pressure chemical ionization (APCI) gave better results than electrospray ionization (ESI) for all analytes, with higher reproducibility and lower detection limits. Therefore APCI was chosen for the determination of the analytes in seawater samples using stir bar sorptive extraction-liquid desorption (SBSE-LD).Quantitative analysis was performed in multiple reaction monitoring (MRM) mode; fragmentation pathways of the analytes with regard to the formation of the MRM ions were also proposed.For the analysis of seawater samples, calibration curves were drawn using SBSE in spiked seawater. All figures of merit of the method were satisfactory; limits of detection were particularly low for the four analytes ionized in positive mode, being in the range 8-31 ng/L. The method was applied to the determination of the six UV filters in seawater samples from Liguria, Italy. Only benzophenone-3 (BP-3) and ethylhexyl methoxycinnamate (EHMC) were measured in the analyzed samples; some of the remaining analytes were also detected but always below the limit of quantitation.  相似文献   

10.
Theanine is the major amino acid present in Camellia sinensis or green tea. A method for determining theanine in its native state using liquid chromatography with positive-mode electrospray ionization mass spectrometric detection was developed. Quantitation of theanine was achieved using theanine-[2H5] as an internal standard. This approach was utilized on different green tea matrix materials that are commonly used as dietary supplements including powdered plant leaves, a powdered plant leaf extract, and an oral dosage form that contains green tea. The theanine response was linear over several orders of magnitude, and excellent measurement precision was obtained for all three materials using the developed method.  相似文献   

11.
Non-suppressed and suppressed ion chromatography in combination with atmospheric pressure ionization mass spectrometry are compared with special respect to sensitivity for the analysis of low-molecular-mass anions. Iodate, bromate, bromide, sulfate, thiosulfate and bromide could be separated by non-suppressed ion chromatography using a low-capacity anion-exchange column and ammonium citrate as mobile phase. Absolute detection limits between 0.4 and 0.7 ng could be achieved; employing a column requiring a flow-rate of 1 ml/min for optimum performance, splitting was necessary so that only 120 μl/min entered the interface of the mass spectrometer resulting in detection limits between 0.03 and 0.06 mg/l. The same stationary phase (packed into a narrow-bore column which allowed operation without splitting) was suitable for the separation of oxyhalides in the suppressed mode with detection limits of 0.5 μg/l (50 pg) with sodium carbonate as eluent. The method was applied to the analysis of drinking water for oxyhalides. The sample pretreatment for the removal of matrix anions (sulfate, chloride and hydrogencarbonate) is described.  相似文献   

12.
Coupling normal-phase LC separation methods to atmospheric pressure ionization (API)-mass spectrometry (MS) for detection can be problematic because of the possible detonation hazard and because nonpolar solvents do not support ionization of the analyte. Unlike achiral separations, enantiomeric separations can be very sensitive to small changes in the separation environment. Thus, completely substituting the main mobile phase component of a normal-phase LC solvent for an environmentally friendly, nonflammable fluorocarbon-ether as a safe and effective solvent must be thoroughly evaluated before it can be recommended for enantioselective separations with API-MS detection. Ethoxynonafluorobutane (ENFB) was used as a normal-phase solvent for the enantioselective separation of 15 compounds on two macrocyclic glycopeptide chiral stationary phases (CSPs) and a new polymeric chiral stationary phase. The chromatographic figures of merit were compared between results obtained with the ENFB mobile phases and traditional heptane-based mobile phases. In addition, the limits of detection (LOD) using the API-MS compatible ENFB were examined, as well as flow rate sensitivities and compatibilities with common polar organic modifier. ENFB is a safe and effective solvent for enantioselective normal-phase/API-MS analyses.  相似文献   

13.
High-performance liquid chromatography (HPLC) with diode-array detection interfaced to atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) is applied to analyze phthalides from Chuanxiong (the rhizome of Ligusticum chuanxiong). This herb material, containing plenty of phthalide compositions, is selected as the analytical target in this paper for its hematological activity. Some of the phthalides are not stable and are difficult to analyze by gas chromatography-MS. Under optimized LC-MS-MS conditions, six phthalides in the methanol extract of Chuanxiong are unambiguously identified, and characteristic fragments are obtained using homemade reference standards. Ten other phthalides in the extract are confirmed by means of LC-APCI-MS with positive-negative ion mode and collision-induced dissociation in combination with UV spectrophotometry. The results show that LC-MS-MS is a method of choice for fast detection and detailed structural analysis of such mixtures in the crude extract of Chuanxiong.  相似文献   

14.
LC-electrospray ionization (ESI) MS conditions were optimized for the individual chiral separation of 19 compounds of pharmaceutical interest using the macrocyclic glycopeptide-based chiral stationary phases in both polar organic and reversed-phase modes (RPM). The influence of mobile phase composition and MS additive type on sensitivity was investigated for all classes of compounds tested. Compounds with amine or amide groups were efficiently separated, ionized, and detected with the addition of 0.1% (w/w) ammonium trifluoroacetate to the solvent system in either the reversed-phase or polar organic mode (POM). Macrocyclic glycopeptide coupled column technology was initially used to screen all chiral compounds analyzed. Baseline resolution of enantiomers was then achieved with relatively short retention times and high efficiencies on Chirobiotic T, Chirobiotic V or Chirobiotic R narrow bore chiral stationary phases. The polar organic mode offered better limits of detection (as low as 100 pg/ml) and sensitivity over reversed-phase methods. An optimum flow-rate range of 200-400 microl/min was necessary for sensitive chiral LC-ESI-MS analysis.  相似文献   

15.
A simple and sensitive analytical method for the determination of polycarbamate in water samples was developed. In this method, polycarbamate was cleaved under alkaline conditions and derivatized with dimethyl sulfate to methyl dimethyldithiocarbamate (DMDC-methyl) and dimethyl ethylenebisdithiocarbamate (EBDC-dimethyl). After the solid-phase extraction of the resulting methyl derivatives, they were measured by liquid chromatography with tandem mass spectrometry (LC-MS/MS), based on reversed-phase separation and MS/MS detection with positive atmospheric pressure chemical ionization. The absolute recoveries (mean+/-SD) all through the procedure from polycarbamate to DMDC-methyl and EBDC-dimethyl were 62.6+/-4.3 and 73.5+/-5.9%, respectively. The limits of detection and quantification of polycarbamate in the water samples were 0.061 and 0.20 microg/L in the form of DMDC-methyl, and 0.032 and 0.11 microg/L in the form of EBDC-dimethyl, respectively. The method was validated at levels of 0.25, 1.0, and 5.0 microg/L in the tap water and river water samples, and accuracy was achieved in the range of 94-109%. The proposed method can be applied to the determination of trace amounts of polycarbamate in environmental water samples.  相似文献   

16.
Direct analysis in real time (DART) time-of-flight mass spectrometry (TOF-MS) has been tested for its suitability as a detector for gradient elution HPLC. Thereby a strong dependency of signal intensity on the amount of organic solvent present in the eluent could be observed. Adding a make-up liquid (iso-propanol) post-column to the HPLC effluent greatly enhanced detection limits for early eluting compounds. Limits of detection achieved employing this approach were in the range of 7-27 μg L(-1) for the parabene test mixture and 15-87 μg L(-1) for the pharmaceuticals. In further investigations DART ionization was compared to several other widely used atmospheric pressure ionization methods with respect to signal suppression phenomena occurring in when samples with problematic matrices are analyzed. For this purpose extracts from environmental and waste water samples were selected as model matrices which were subsequently spiked with a set of six substances commonly present in personal care products as well as six pharmaceuticals at concentration levels between 100 μg L(-1) and 500 μg L(-1) corresponding to 100 ng L(-1) and 500 ng L(-1) respectively in the original sample. With ionization suppression of less than 11% for most analytes investigated, DART ionization showed similar to even somewhat superior behavior compared to atmospheric pressure chemical ionization (APCI) and atmospheric pressure photo ionization (APPI) for the Danube river water extract; for the more challenging matrix of the sewage plant effluent extract DART provided better results with ion suppression being less than 11% for 9 out of 12 analytes while values for APCI were lying between 20% and >90%. Electrospray ionization (ESI) was much more affected by suppression effects than DART with values between 26% and 80% for Danube river water; in combination with the sewage plant effluent matrix suppression >50% was observed for all analytes.  相似文献   

17.
We report on the development of a new laser-ionization (LI) source operating at atmospheric pressure (AP) for liquid chromatography/mass spectrometry (LC/MS) applications. APLI is introduced as a powerful addition to existing AP ionization techniques, in particular atmospheric-pressure chemical ionization (APCI), electrospray ionization (ESI), and atmospheric pressure photoionization (APPI). Replacing the one-step VUV approach in APPI with step-wise two-photon ionization strongly enhances the selectivity of the ionization process. Furthermore, the photon flux during an ionization event is drastically increased over that of APPI, leading to very low detection limits. In addition, the APLI mechanism generally operates primarily directly on the analyte. This allows for very efficient ionization even of non-polar compounds such as polycyclic aromatic hydrocarbons (PAHs). The APLI source was characterized with a MicroMass Q-Tof Ultima II analyzer. Both the effluent of an HPLC column containing a number of PAHs (benzo[a]pyrene, fluoranthene, anthracene, fluorene) and samples from direct syringe injection were analyzed with respect to selectivity and sensitivity of the overall system. The liquid phase was vaporized by a conventional APCI inlet (AP probe) with the corona needle removed. Ionization was performed through selective resonance-enhanced multi-photon ionization schemes using a high-repetition-rate fixed-frequency excimer laser operating at 248 nm. Detection limits well within the low-fmol regime are readily obtained for various aromatic hydrocarbons that exhibit long-lived electronic states at the energy level of the first photon. Only molecular ions are generated at the low laser fluxes employed ( approximately 1 MW/cm(2)). The design and performance of the laser-ionization source are presented along with results of the analysis of aromatic hydrocarbons.  相似文献   

18.
Liquid chromatography/atmospheric pressure photoionization tandem mass spectrometry (LC/APPI-MS/MS) was investigated as an instrumental method for the analysis of the halogenated norbornene flame retardants, Mirex, Dechloranes 602, 603, 604, and Dechlorane Plus (DP). The LC separation was optimized by screening a variety of stationary and mobile phases, resulting in a short LC separation time of 5 min. Different atmospheric pressure ionization approaches were examined including electrospray ionization, atmospheric pressure chemical ionization, and APPI, each with and without post-column addition. APPI without post-column addition was chosen for providing the best ionization response. The optimized LC/APPI-MS/MS approach resulted in instrument detection limits ranging between 25 and 50 pg. Good linearity was also achieved (up to 25.0 ng/μL; R >0.999). The method was applied to extracts of environmental samples including surface water, fish and sediments for screening purposes, and the results agreed well with those obtained by gas chromatography/mass spectrometry.  相似文献   

19.
Daniel JM  Ehala S  Friess SD  Zenobi R 《The Analyst》2004,129(7):574-578
A new technique is presented for the coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry with liquid delivery systems. Mass measurements of polymers and peptides are demonstrated using a co-dissolved matrix, e.g. alpha-cyano-4-hydroxycinnamic acid (HCCA). Improvements in terms of sensitivity are achieved by optimizing the shape und control of the exit capillary and by using a laser (355 nm) at a 1 kHz repetition rate. Two calibration experiments promise a good applicability of the presented coupling method for quantitative measurements. The limit of detection achieved so far is 500 nM for peptides in methanol solution containing 25 mM HCCA.  相似文献   

20.
《Analytical letters》2012,45(5-6):642-650
The simultaneous determination of selenomethionine, selenoethionine, selenocystine, dimethyldiselenide, and diphenyldiselenide was investigated for the first time by a hyphenated HPLC-IT-TOF-MS technique using atmospheric pressure chemical ionization (APCI). Alkylselenides and phenyldiselenides and also the most common selenoamino acids were successfully determined after optimization of the instrumental and procedural parameters of the above system. Non-polar columns were studied in order to obtain baseline separation and speciation in less than 10 min. Selenium speciation was achieved successfully after optimization of the instrumental and procedural parameters of the aforementioned system. The APCI interface was studied at different zone temperatures and the most characteristic ions for each analyte were defined using both positive and negative polarity. The detection limits of the six selenium species ranged between 13 and 59 µg/L and the relative standard deviation was between 4.2 and 9.3%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号