首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A molecularly imprinted polymer was developed and used for solid-phase extraction (MISPE) of the antihelmintic fenbendazole in beef liver samples. Detection of the analyte was accomplished using square wave voltammetry (SWV) at a cylindrical carbon fibre microelectrode (CFME). A mixture of MeOH/HAc (9:1) was employed both as eluent in the MISPE system and as working medium for electrochemical detection of fenbendazole. The limit of detection was 1.9 × 10−7 mol L−1 (57 μg L−1), which was appropriate for the determination of fenbendazole at the maximum residue level permitted by the European Commission (500 μg kg−1 in liver). Given that the SW voltammetric analysis could not be directly performed in the sample extract as a consequence of interference from some sample components, a sample clean-up with a MIP for selectively retaining fenbendazole was performed. The MIP was synthesized using a 1:8:22 template/methacrylic acid/ethylene glycol dimethacrylate ratio. A Britton–Robinson Buffer of pH 9.0 was selected for retaining fenbendazole in the MIP cartridges, and an eluent volume of 5.0 mL at a flow rate of 2.0 mL min−1 was chosen in the elution step. Cross-reactivity with the MIP was observed for other benzimidazoles. The synthesized MIP exhibited a good selectivity for benzimidazoles with respect to other veterinary drugs. The applicability of the MISPE-SWV method was tested with beef liver samples, spiked with fenbendazole at 5,000 and 500 μg kg−1. Results obtained for ten different liver samples yielded mean recoveries of (95 ± 12)% and (96 ± 11)% for the upper and lower concentration level, respectively.  相似文献   

2.
A carbaryl and 1-naphtol molecular imprinted polymers (MIP1 and MIP 2, respectively) were prepared using suspension polymerization and tested for selective and reversible binding to carbaryl and 1-naphtol, respectively. In the suspension polymerization technique used, polymers of methacrylic acid (MAA), highly cross-linked with ethylene dimethacrylate, provide a specific binding sites for the carbaryl molecule and its metabolite when using it as a template to be removed after polymerization. The molecular imprinted polymer with a particle size of approximately 5 microm were isolated and packed into a pre-column (50 mm x 4.6 mm id) that was used to isolate carbaryl and its metabolite from complex matrices injected on a high performance liquid chromatography system using ultra-violet detection without extensive sample preparation and clean up. The HPLC method had a detection limit of 1.00 ng/mL and a linear response (r2 > 0.98) over the concentration range of 1.00-10.0 ng/mL.  相似文献   

3.
The electrochemical solid phase micro-extraction of salicylic acid (SA) at graphite-epoxy-composed solid electrode surface was studied by cyclic voltammetry. SA was oxidized electrochemically in pH 12.0 aqueous solution at 0.70 V (vs. saturated calomel electrode) for 7 s. The oxidized product shows two surface-controlled reversible redox couples with two proton transferred in the pH range of 1.0∼6.0 and one proton transferred in the pH range of 10.0∼13.0 and is extracted on the electrode surface with a kinetic Boltzman function of i p = 3.473–4.499/[1 + e(t − 7.332)/6.123] (χ 2 = 0.00285 μA). The anodic peak current of the extracted specie in differential pulse voltammograms is proportional to the concentration of SA with regression equation of i p = −5.913 + 0.4843 c (R = 0.995, SD = 1.6 μA) in the range of 5.00∼200 μM. The detection limit is 5.00 μM with RSD of 1.59% at 60 μM. The method is sensitive and convenient and was applied to the detection of SA in mouse blood samples with satisfactory results.  相似文献   

4.
In the present work, a fluorimetric automatic method based on multisyringe flow injection analysis (MSFIA) was developed for in vitro evaluation of scavenging capacity against nitric oxide (NO) using 4,5-diaminofluorescein (DAF-2) as an NO-selective fluorogenic probe. The MSFIA manifold was assembled to perform the in-line generation of NO and the competitive reaction of putative scavenger molecules and DAF-2 with NO at conditions close to those found in vivo regarding temperature (37°C), pH (7.4), and concentration of NO (less than 1 μM). This approach allowed the evaluation of scavenging capacity against NO by endogenous antioxidant molecules, pharmaceutical compounds, and human plasma. IC50 values were calculated for rutin (1.30 ± 0.02 μM, positive control), cysteine (321 ± 8 μM), reduced glutathione (1106 ± 93 μM), uric acid (134 ± 12 μM), dipyrone (1.36 ± 0.06 μM), and captopril (363 ± 28 μM). A high degree of automation was attained as the successive dilution of antioxidant standard solutions required for IC50 assessment was performed automatically, in a dilution chamber placed in the flow system. A determination throughput of 16 h-1 and a good precision were attained (relative standard deviation between 1.6 and 9.0%), fostering the application of the proposed method to routine/screening analysis of scavenging capacity against NO.  相似文献   

5.
 A new sample insertion device for the stabilized capacitive plasma (SCP) has been developed, which enables it to analyze dry residues of micro amounts of liquid samples. Insertion was applied into an SCP as plasma source because of its good stability and excitation properties as well as its low instrument and operation costs. The plasma is sustained at a frequency of 27.12 MHz and an RF power of 150 W. For analysis the liquid samples are positioned at the tip of a quartz rod with the aid of a μL syringe. Then the sample is dried and the sampling rod inserted into the plasma. After optimization of the carrier gas flow (5 L/h) and the sample volume (20 μL) the detection limit for Pb with Ar as plasma gas is 200 pg. By further improving the guidance of the insertion detection limits for Pb, Cu, Cd and Mg in the 1 to 30 ng/mL range or 20 to 600 pg range absolute were obtained. It was found that the detection limits in the case of He are better than those obtained with Ar. The matrix interferences caused by changes in the concentration of the easily ionizable element Na were found to be below 10% for Na concentrations of up to 0.45 μg/mL. Ethanol concentrations of up to 14% in the analyte solutions did not cause any interferences. Received December 17, 1998. Revision June 4, 1999.  相似文献   

6.
 A monosegmented flow system (MCFA) is proposed to achieve slow enzymatic spectrophotometric determinations, here applied to the determination of triglycerides in blood serum. The sample (4.5 μL), enzymatic reagent (150 μL) and an air plug (100 μL) are simultaneously inserted into a carrier stream buffered to pH 7.9 (Tris ⋅ HCl). In order to avoid the cumbersome step of air removal, a relocating detector was used. This system handles about 60 samples/h, yielding precise results (r.s.d. usually<2.5%). Sensitivity is 56 mAU ⋅ L/mmol up to 6 mmol/L triglycerides. Accuracy was assessed by running 50 samples already analysed by a conventional procedure yielding the equation CMCFA(mmol/L)=1.00(±0.04) CRef(mmol/L)−0.03(±0.08); r=0.990. Received: 22 January 1997/Revised: 12 March 1997/Accepted: 28 March 1997  相似文献   

7.
A method is demonstrated for analysis of vitamin D fortified dietary supplements that eliminates virtually all chemical pretreatment prior to analysis, which is referred to as a “dilute-and-shoot” method. Three mass spectrometers, in parallel, plus a UV detector, an evaporative light-scattering detector (ELSD), and a corona charged aerosol detector (CAD) were used to allow a comparison of six detectors simultaneously. Ultraviolet data were analyzed using internal standard, external standard, and response factor approaches. The contents of gelcaps that contained 2,000 IU (50 μg) vitamin D3 in rice bran oil, diluted to 100 mL, were analyzed without the need for lengthy saponification and extraction. Vitamin D3 was analyzed using UV detection, extracted ion chromatograms, selected ion monitoring (SIM) atmospheric pressure chemical ionization mass spectrometry (APCI-MS), and two transitions of multiple reaction monitoring (MRM) APCI-MS. The internal standard, external standard, and response factor methods gave values of 0.5870 ± 0.0045, 0.5893 ± 0.0041, and 0.5889 ± 0.0045 μg/mL, respectively, by UV detection. The values obtained by MS were 0.6117 ± 0.0140, 0.6018 ± 0.0244, and 0.5848 ± 0.0146 μg/mL by SIM and two transitions of MRM, respectively. The triacylglycerols in the oils were analyzed using full-scan APCI-MS, electrospray ionization (ESI) MS, up to MS4, an ELSD, and a CAD. The method proved to be very sensitive for vitamin D3, as well as triacylglycerols (TAGs), allowing identification of intact TAGs containing fatty acids up to 28 carbons in length. LC-ESI-MS of glycerin polymers is also demonstrated.  相似文献   

8.
 A novel fluorimetric method has been developed for selective determination of DNA with the molecular “Light Switch” complex of Ru(bipy)2(dppz)2+. The maximum fluorescence intensity was produced in the pH range of 9.3–11.5, with the maximum excitation and emission wavelength of 471.8 nm and 599.8 nm, respectively. Under the optimum conditions, the fluorescence intensity was in proportion to the concentration of DNA. The linear range for calf thymus DNA salmon sperm DNA and herring sperm DNA reaches from the limit of determination to 1.5 μg/mL. The limits of determination for calf thymus DNA salmon sperm DNA and herring sperm DNA are 3.3 ng/mL, 2.8 ng/mL and 4.4 ng/mL, respectively. When the proposed method was used to determine DNA in the presence of some coexisting substances, a satisfactory result was obtained. Received December 29, 1998. Revision June 28, 1999.  相似文献   

9.
The electrochemical oxidation of thiocytosine on the surface of carbon-paste electrode modified with Schiff base (salophen derivatives) complexes of cobalt is studied. The effect of the substituents in the structure of salophen on the catalytic property of the modified electrode is investigated by using cyclic and differential pulse voltammetry. Cobalt (II)-5-nitrosalophen, because of its electrophilic functional groups, leads to a considerable enhancement in the catalytic activity, sensitivity (peak current), and a marked increase in the anodic potential of the modified electrode. The differential pulse voltammetry is applied as a very sensitive method for the detection of thiocytosine. The linear dynamic range was between 1 × 10−3 to 4 × 10−6 M with a slope of 0.0168 μA/μM, and the detection limit was 1 × 10−6 M. The modified electrode is successfully applied for the voltammetric detection of thiocytosine in human synthetic serum sample and also pharmaceutical preparations. A linear range from 1 × 10−3 to 1 × 10−5 M with a slope of 0.0175 μA/μM is resulted for the standard addition of thiocytosine spiked to the buffered human serum, which is differing from the curve in buffer solution about 4%. The electrode has a very good reproducibility (relative standard deviation for the slope of the calibration curve is less than 3.5% based on six determinations in a month), high stability in its voltammetric response and low detection limit for thiocytosine, and high electrochemical sensitivity with respect to other biological thiols such as cysteine.  相似文献   

10.
A simple flow injection on line separation and preconcentration system coupled to hydride generation atomic fluorescence spectrometry (HG-AFS) was developed for ultra-trace cadmium determination in seawater. With the sample pH kept at 3.0, the preconcentration of cadmium on the inner walls of the knotted reactor was carried out based on the retention of cadmium complex with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one. A 0.2 mol L−1 HCl was introduced to elute the retained analyte complex and merge with KBH4 solution for HG-AFS detection. Under the optimal experimental conditions, an enhancement factor of 12 was obtained with a sample consumption of 12.0 mL. The limit of detection was 3.2 ng L−1 with a sample frequency of 24 h−1. The developed method was validated by the analysis of cadmium in certified reference materials, and was applied to the determination of cadmium in four seawater samples with R.S.D. of around 10%. Correspondence: Hong Wu, Department of Chemistry, Xuzhou Normal University, Xuzhou 221116, P.R. China  相似文献   

11.
Estrone is one of the important potential endocrine-disrupting compounds, and the sensitive and reliable analytical methods for the determination of estrone are required for the assurance of human health. In this paper, using estrone as template molecule, 3-aminopropyltriethoxysilane as function monomer, and tetraethoxysilicane as cross-linker, a highly selective molecularly imprinted microsphere was synthesized by surface molecular imprinting technique combined with a sol–gel process. The imprinted material was characterized by the Fourier transform infrared and static adsorption experiments, and the results showed that it exhibited good recognition and selective ability for estrone. A novel method for separation and determination of trace estrone in environmental sample was developed using on-line molecularly imprinted solid-phase extraction coupled to high-performance liquid chromatography. With a sample loading flow rate of 2.6 mL min−1 for a 9.6-min extraction, the enrichment factor obtained by the slopes of the linear portion in comparison with the direct injection of 10 μL standard sample solution was 1,045. The detection limit (S/N = 3) was 5.7 ng L−1, and the relative standard deviations for nine replicate extractions of 5.0 μg L−1 estrone was less than 10.0%. This method was evaluated for quantitative determination of estrone in well and lake water samples spiked at two levels (0.5 and 1.0 μg L−1) with recoveries ranging from 86% to 95%.   相似文献   

12.
Summary A monolithic ODS-silica gel column modified by saturating it with lithium dodecylsulfate (Li-DS) was firstly used to separate monovalent cations simultaneously including H+, Na+, NH4 + and K+ by ion-chromatography (IC). Using an acidified 60 mM LiCl solution (pH 3.95, containing 0.10 mM Li-DS) as eluent, these monovalent cations were separated well in the order of Na+<NH4 +<K+<H+ within 3 min at a flow rate of 2.0 mL min−1. The detection limits of these cations by this method with conductivity detection were 20.0 μM for Na+, 12.0 μM for NH4 +, 9.84 μM for K+ and 6.20 μM for H+. Acid rain water samples with a pH value less than 5.00 could be analyzed directly with this IC system.  相似文献   

13.
The opioid tilidine is a prodrug which is hepatically metabolized to active nortilidine and bisnortilidine. Due to the increasing abuse of tilidine by drug users and the lack of a specific immunoassay, we developed an analytical method for the quantification of tilidine, nortilidine, and bisnortilidine in urine suitable for screening. In a following step, this method was used to establish data on excretion kinetics of the substances in order to evaluate the time window of detection after a single oral dose of tilidine/naloxone and also was applied to authentic urine samples from correctional facilities. Urine samples were mixed with internal standard solution and extracted on a weak cation exchanger at pH 6 using a Symbiosis Pico system. The chromatographic separation was achieved within a 3.5-min run time on a Phenylhexyl column (50 × 2.0 mm, 5 μm) via gradient elution (methanol and 0.2% formic acid) at a flow rate of 0.50 mL/min. The ESI-MS/MS was performed on a QTrap 3,200 in positive multiple reaction monitoring mode using two mass transitions per analyte. Validating the method resulted in a lower limit of quantification of 1.0 μg/L followed by a linear calibration range to 100 μg/L for each analyte (r 2 > 0.99). The analytical method allowed the detection of a single dose of a commercially available tilidine solution up to 7 days after administration. Using this highly sensitive method, 55 of 3,665 urine samples were tested positive.  相似文献   

14.
A phosphorimetric solid phase assay is proposed for the determination of the pesticide carbaryl (CBL) at room temperature. CBL was spotted on filter paper together with Tl(I) as heavy metal, and dried for 3 min, after which the diffuse transmitted phosphorescence was measured using two quartz plates to avoid the quenching effect produced by atmospheric oxygen. The linear dynamic range was 0.5–4.0 μg/mL and the detection and quantification limits were 0.09 and 0.31 μg/mL, respectively. The precision of the method, expressed as relative standard deviation, was 2.3% for a sample containing 2.0 μg/mL of CBL. The method was applied to the determination of CBL residues in cereals, potatoes and waters, obtaining recoveries ranging between 92 and 105%. Received: 10 October 1997 / Revised: 2 February 1998 / Accepted: 7 February 1998  相似文献   

15.
An aptamer-based label-free approach to hemin recognition and DNA assay using capillary electrophoresis with chemiluminescence detection is introduced here. Two guanine-rich DNA aptamers were used as the recognition element and target DNA, respectively. In the presence of potassium ions, the two aptamers folded into the G-quartet structures, binding hemin with high specificity and affinity. Based on the G-quartet–hemin interactions, the ligand molecule was specifically recognized with a K d ≈ 73 nM, and the target DNA could be detected at 0.1 μM. In phosphate buffer of pH 11.0, hemin catalyzed the H2O2-mediated oxidation of luminol to generate strong chemiluminescence signal; thus the target molecule itself served as an indicator for the molecule–aptamer interaction, which made the labeling and/or modification of aptamers or target molecules unnecessary. This label-free method for molecular recognition and DNA detection is therefore simple, easy, and effective. Figure A label-free approach to aptamer-based hemin recognition and DNA detection is introduced, which gives great potential for using a small molecule itself as the indicator for molecular recognition and DNA detection thereby avoiding any labeling or modification step  相似文献   

16.
A novel approach to the detection of estriol using a flow injection system coupled to enhanced chemiluminescent immunoassay was developed based on noncompetitive immunoassay formats. A conjugated estriol-ovalbumin immobilized immunoaffinity column was inserted into the flow system to trap the unbound horseradish peroxidase (HRP)-labeled antibody after an off-line incubation of estriol and HRP-labeled anti-estriol antibody. The trapped enzyme conjugate was detected by the injection of chemiluminescent substrates to produce enhanced chemiluminescence. The linear range for the determination of estriol is 10.0 to 400 ng · mL−1 with a correlation coefficient of 0.996 and a detection limit of 5.0 ng · mL−1. The total time for sampling and chemiluminescent detection of one sample is 400 seconds after 30 min of pre-incubation. The results for pregnancy serum samples obtained by this method are in good agreement with those obtained using ELISA.  相似文献   

17.
A flow injection–solid-phase spectroscopy (FI-SPS) system implemented with photochemically induced fluorescence (PIF) is described for the rapid and very sensitive determination of reserpine in biological fluids and pharmaceutical formulations. An intensively fluorescent photoproduct is in-line generated, retained on C18 silica gel in the detection area and monitored at 394/489 nm (λ ex/λ em). After the establishment of the appropriate working variables, the system is calibrated at two different injection volumes, 100 and 800 μL, achieving detection limits of 0.33 and 0.05 ng mL−1, respectively. The RSD for reserpine at 2 ng mL−1 (800 μL) was 1.5% (n = 10). The sampling rates were 46 and 43 h−1 for each injection volume, respectively. The potential interference of some common species coexisting with reserpine in the analysed samples was also studied. The procedure was successfully applied to commercial formulations, urine and serum without any previous treatment of samples. Recoveries ranged from 94.9 to 100.2%.  相似文献   

18.
In the present study, a novel, fast and simple liquid chromatographic method was developed and validated for the simultaneous determination of rosiglitazone and metformin in pharmaceutical preparations. The separation was achieved on a phenyl column (250 × 4.6 mm i.d., 5 μm) using a mobile phase composed of acetonitrile:10.0 mM phosphate buffer pH 5.5 (70:30, v/v). The flow rate was 1 mL min−1. UV detection was performed at 245 nm and verapamil was used as internal standard. The developed method was validated in terms of stability, specificity, sensitivity, linearity, accuracy, precision and robustness. The limit of quantification was 0.02 μg mL−1 for both drugs. The method developed was successfully applied to the simultaneous determination of rosiglitazone and metformin in pharmaceutical preparations. The results were compared to two methods reported in the literature and no significant difference was found statistically.  相似文献   

19.
The performance of the dispersive liquid–liquid microextraction (DLLME) technique for the determination of eight UV filters and a structurally related personal care species, benzyl salicylate (BzS), in environmental water samples is evaluated. After extraction, analytes were determined by gas chromatography combined with mass spectrometry detection (GC-MS). Parameters potentially affecting the performance of the sample preparation method (sample pH, ionic strength, type and volume of dispersant and extractant solvents) were systematically investigated using both multi- and univariant optimization strategies. Under final working conditions, analytes were extracted from 10 mL water samples by addition of 1 mL of acetone (dispersant) containing 60 μL of chlorobenzene (extractant), without modifying either the pH or the ionic strength of the sample. Limits of quantification (LOQs) between 2 and 14 ng L−1, inter-day variability (evaluated with relative standard deviations, RSDs) from 9% to 14% and good linearity up to concentrations of 10,000 ng L−1 were obtained. Moreover, the efficiency of the extraction was scarcely affected by the type of water sample. With the only exception of 2-ethylhexyl-p-dimethylaminobenzoate (EHPABA), compounds were found in environmental water samples at concentrations between 6 ± 1 ng L−1 and 26 ± 2 ng mL−1.  相似文献   

20.
Bulk screen-printed electrodes (bSPEs) modified with zirconium phosphate (ZrP) and Meldola blue (MB) and by electrochemical deposition of a Reineckate film (bMBZrPRs-SPEs) have been constructed and used as NADH sensors. Cyclic voltammetric investigation of these bulk electrochemically modified screen-printed electrodes revealed stable catalytic activity in oxidation of the reduced form of the coenzyme nicotinamide adenine dinucleotide (NADH). Flow-injection analysis (FIA) coupled with amperometric detection confirmed the improved stability of the bMBZrPRs-SPEs (10−4 mol L−1 NADH, %RSD = 4.2, n = 90, pH 7.0). Other conditions, for example applied working potential (+50 mV relative to Ag|AgCl), flow rate (0.30 mL min−1) and pH-dependence (range 4.0–10.0) were evaluated and optimized. A glycerol biosensor, prepared by immobilizing glycerol dehydrogenase (GDH) on the working electrode area of a bMBZrPRs-SPE, was also assembled. The biosensor was most stable at pH 8.5 (%RSD = 5.6, n = 70, 0.25 mmol L−1 glycerol). The detection and quantification limits were 2.8 × 10−6 and 9.4 × 10−6 mol L−1, respectively, and the linear working range was between 1.0 × 10−5 and 1.0 × 10−4 mol L−1. To assess the effect of interferences, and recovery by the probe we analyzed samples taken during fermentation of chemically defined grape juice medium and compared the results with those obtained by HPLC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号