首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Summary A polarographic investigation on the N-benzoylphenylhydroxylamine (BPHA) complex of tin has been made in a mixture of chloroform and methanol. From the studies it has been confirmed that the complex is formed by tetravalent tin. A tentative mechanism of the oxidation of tin(II) in presence of BPHA has been suggested. Moreover, a rapid, sensitive and specific method of determination of tin in trace quantities by derivative pulse polarography has been developed. The chloroform extract can be directly subjected to polarography after addition of requisite quantities of water and methanolic lithium perchlorate. Effect of different supporting electrolytes on the system has been studied. By the described method 7×10–7 M to 2×10–5 M tin can be determined without interference from large quantities of the elements commonly associated with tin and also from a large number of other elements and complexing agents.
Polarographische Untersuchung des N-Benzoylphenylhydroxylamin-Komplexes mit Zinn und pulspolarographische Bestimmung von Zinn im Spurenbereich nach Extraktion
Zusammenfassung Eine polarographische Untersuchung des N-Benzoyl-phenylhydroxylamin (BPHA)-Komplexes mit Zinn in einer Mischung von Chloroform und Methanol wurde durchgeführt. Es konnte festgestellt werden, daß der Komplex von vierwertigem Zinn gebildet wird. Ein Mechanismus der Oxidation von Zinn(II) in Gegenwart von BPHA wird vorgeschlagen. Die entwickelte Methode eignet sich in Verbindung mit der derivativen Pulspolarographie zur schnellen, spezifischen und empfindlichen Bestimmung von Zinn im Spurenbereich. Nach Zugabe einer bestimmten Menge Wasser und methanolischer Lithiumperchloratlösung kann der Chloroform-Extrakt des Zinn-BPHA-Komplexes direkt polarographiert werden. Der Einfluß verschiedener Leitsalze wurde untersucht. Mit diesem Verfahren läßt sich Zinn im Bereich von 7×10–7 M bis 2×10–5 M in Anwesenheit großer Mengen anderer Metallionen und Komplexierungsmittel bestimmen.
  相似文献   

2.
Zusammenfassung Eine Methode zur oscillopolarographischen Bestimmung von Wismut und Blei in mineralischen Rohstoffen wurde ausgearbeitet. Die Abtrennung beider Elemente wurde in einem Arbeitsgang durch Chloroformextraktion der Diäthyldithiocarbamidate aus einer Lösung, die NatriumKaliumtartrat, Tiron, Schwarzenbachs Puffer und Kaliumcyanid enthielt, durchgeführt. Die extrahierten Elemente wurden durch Reextraktion mit 2 m Salzsäure (Pb) und 6 m Salzsäure (Bi) voneinander getrennt.Die oscillopolarographische Bestimmung von Wismut wurde in 3 m Salzsäure durchgeführt. Für Spurenkonzentrationen wurde eine Lösung von 1 m Perchlorsäure und 0,2 m Ammoniumchlorid verwendet.Blei wurde oscillopolarographisch in einer Lösung von 0,1 m Ammoniumthiocyanat, 0,25 m Hexamethylentetramin und 0,5 m Ammoniumperchlorat bestimmt. Die Methode eignet sich zur Bestimmung verhältnism äßig kleiner Mengen bis zu Spurenkonzentrationen von Wismut und Blei. Sie ist verhältnismäßig schnell, denn sie ermöglicht eine fast gleichzeitige Bestimmung beider Elemente aus einer Einwaage. Das Verfahren wurde mit Erfolg bei Erzen angewendet. Der Fehler liegt in einem Bereich von 3–5%.
Summary The simultaneous oscillopolarographic determination of bismuth and lead has been worked out: The separation of both elements together from interfering material is carried out by extraction with diethyldithiocarbamidate and chloroform from a medium of sodium potassium tartrate, tiron, Schwarzenbach buffer and potassium cyanide. The extracted elements are subsequently separated by re-extraction with 2 M hydrochloric acid (Pb) and 6 M hydrochloric acid (Bi). The oscillopolarographic determination of bismuth is performed in 3 M hydrochloric acid (in the case of trace concentrations a solution of 1 M perchloric acid and 0.2 M ammonium chloride is applied). For the oscillopolarographic determination of lead a solution of 0.1 M ammonium thiocyanate, 0.25 M hexamethylene-tetramine and 0.5 M ammonium perchlorate is employed. The method is suitable for the determination of low concentrations of lead and bismuth in the range of 10–5–10–6 M and is recommended especially for ores. The relative error is ±3–5%.
  相似文献   

3.
Zusammenfassung Es wird eine spurenanalytische Methode zur Bestimmung von Verunreinigungen in hochreinem Indium beschrieben. Die Elemente Blei, Eisen, Cadmium, Kupfer, Thallium, Wismut und Zink werden durch Isopropylätherextraktion aus Halogensäuren angereichert und polarographisch bestimmt. Die Bedingungen zur extraktiven Anreicherung werden eingehend behandelt. Zur Vermeidung von Einschleppungen wird weitgehend im geschlossenen System gearbeitet. Die Bestimmung der genannten Elemente ist bis 10–6% mit einer Genauigkeit von besser als ± 10% möglich.  相似文献   

4.
Zusammenfassung Die invers-voltammetrisehe Bestimmung von Zinn kann bei einem 105fachen Bleiüberschuß nach der Oxydation des Zinn-Hämateinkomplexes an einer Kohlepaste-Elektrode durchgeführt werden. Dazu wird die bleihaltige salzsaure Zinnlösung mit einer Lösung von Hämatein in Dioxan versetzt und nach einer Vorelektrolyse bei offenem Stromkreis das Voltammogramm zwischen ±0,0 und +1,0 V (GSE) aufgenommen. Das Strommaximum des Oxydationspeaks liegt bei +0,72 V. Die Peakhöhe ist bei einem 104- bis 105fachen Bleiüberschuß der Zinnkonzentration zwischen 10 und 100 ng/ml proportional. Das Bestimmungsverfahren wird an einem Bleistandard mit einem Zinngehalt von 0,005% erprobt. Die relative Standardabweichung der Analysenergebnisse beträgt 4,6%. Die Bestimmung kann auch in Gegenwart eines 105fachen Überschusses von Zink vorgenommen werden. Fe(III), Cu(II), Sb(III) und Sb(V) stören, wenn sie in zu hoher Konzentration vorhegen. — Zur Bestimmung von Blei in Gegenwart von Zinn wird Pb(II) zu Pb(IV) oxydiert, das als Bleidioxid während der Vorelektrolyse abgeschieden und durch kathodischen Spannungsablauf wieder gelöst wird. Die Bestimmung kann in Gegenwart eines 100fachen Zinnüberschusses erfolgen, wenn die Zusatzmethode angewandt wird. — Es werden einige von der üblichen invers-voltammetrischen Praxis abweichenden Besonderheiten und die Reaktionsfolgen beider Bestimmungsverfahren diskutiert.
Inverse-voltammetric determination of tin and lead in the presence of each other at the carbon-paste electrode
The inverse-voltammetric determination of tin can be carried out in the presence of a 105-fold excess of lead by oxydation of the tin hematein complex on the carbon-paste electrode. For that purpose, to the solution containing tin and lead a solution of hematein in dioxane is added and the voltammogram is recorded between 0.0 and +1.0 V (SSE). Pre-electrolysis is performed at ±0.0 V without polarizing the electrode. The peak potential of the oxydation signal appears near +0.72 V. The peak height is proportional to the concentration of tin in the range between 10 and 100 ng/ml. The determination is not disturbed by a 104- to 105-fold excess of lead and zinc. The method is applied to a standard sample of lead containing 0.005% tin. The standard deviation was 4.6%. Fe(III), Cu(II), Sb(III) and Sb(V) interfere if these elements are present in too high a concentration. — In the determination of lead in the presence of tin, Pb(II) is oxidized forming PbO2 which is deposited on the surface of the electrode and redissolved by subsequent cathodic voltage scanning. The determination of lead can be carried out by the addition technique in the presence of a 100-fold excess of tin.— The order of the reactions and some further details of both methods are discussed.


Vorgetragen auf der GDCh-Hauptversammlung in Hamburg im September 1969.  相似文献   

5.
Summary Tin(IV), in the presence of cetyldimethylbenzylammonium chloride (CDBA), forms with Pyrogallol Red (PR) a complex SnPR-CDBA. This complex floates at the interface between hexane and aqueous medium. It dissolves in acetone and can be advantageously used for the determination of tin. The molar absorptivity is 6.5×104 l·mole–1·cm–1 at 480 nm. The method is selective when citric acid is used as masking agent. Phosphate, fluoride, EDTA, nitrite and sulphide interfere.
Zusammenfassung Zinn(IV) bildet mit Pyrogallolrot (PR) in Gegenwart von Cetyldimethylbenzylammoniumchlorid (CDBA) einen Komplex. Dieser wird flotiert, in Aceton gelöst und zur Bestimmung von Zinn verwendet. Der molare Absorptionskoeffizient bei =480 nm beträgt =6,5·104 l·mol–1 cm–1. Die Methode ist selektiv, wenn Zitrate zur Maskierung verwendet werden. Es stören Phosphat, Fluorid, ÄDTA, Nitrit und Sulfid.
  相似文献   

6.
Summary Classical anodic stripping analysis is greatly improved with respect to sensitivity and selectivity if an ac polarographic technique is applied. By using the phase sensitive second harmonic detection mode, the peak-to-peak measurement is more accurate and less disturbed by interfering elements than the evaluation of one broader peak with respect to a curved base line typical for the classical dc stripping analysis. Mineral and rock sample solutions can thus be analyzed without any separation or enrichment procedures in the range of 0.1–1000 ppm of lead in the sample with a standard deviation of <5 %. This holds also for flameless atomic absorption in the range >1 ppm. In both cases the standard addition calibration has to be applied. Because of the uncertainty of the automatic background correction in the case of a band spectra in the wavelength range of interest produced by interfering substances, the electrochemical method is more superior the lower the lead concentration is.
Kritischer Vergleich der flammenlosen Atomabsorptionsspektroskopie mit einer verbesserten inversvoltammetrischen Methode für die schnelle Spurenbestimmung von Blei in geologischen Proben
Zusammenfassung Die Empfindlichkeit und Selektivität der Inversvoltammetrie läßt sich entscheidend verbessern, wenn ein Wechselstromverfahren angewandt wird. Bei der Registrierung der phasenselektiven »zweiten Harmonischen« ist die Auswertung wegen einer Spitzen-zu-Spitzen-Messung zweier scharfer Peaks genauer und weniger gestört als bei der klassischen Gleichstromtechnik, wo ein breiter Peak relativ zu einer gekrümmten Basislinie auszuwerten ist. Mineral- und Gesteinsprobenlösungen lassen sich daher ohne weitere Trennoder Anreicherungsschritte im Bereich 0,1–1000 ppm Blei in der Probe mit einer Standardabwichung von <5 % analysieren. Dies gilt für Bleigehalte über 1 ppm auch für die flammenlose Atomabsorption. In beiden Fällen ist allerdings die Standardadditions-auswertung anzuwenden. Wegen der Unsicherheit der automatischen Untergrundkompensation im Fall eines Bandenspektrums im interessierenden Wellenlängenbereich, hervorgerufen durch störende Substanzen, wird die elektrochemische Methode mit abnehmenden Bleigehalten zunehmend überlegener.
  相似文献   

7.
Zusammenfassung Es wurde eine Trennung von kleinen Mengen Blei (0,2–5 mg) von einem großen Überschuß von Kupfer (200 mg) und Eisen (300 mg) ausgearbeitet. Das Verfahren beruht auf der gemeinsamen Extraktion von Blei, Kupfer und anderen Elementen mit einer Lösung von Diäthylammoniumdiäthyldithiocarbamidat in Chloroform aus 1 n Salzsäure bei Gegenwart von Ascorbinsäure und auf der selektiven Reextraktion von Blei mit 4 n Salzsäure. In dieser Weise wird Blei gleichzeitig auch von anderen Elementen (Bi, Sb, Tl, Sn, Mo, As) abgetrennt, die die in 2 n Salzsäure vorgenommene polarographische Bestimmung von Blei bei Gegenwart von Natriumhypophosphit stören. Das Trennverfahren wurde auf die Bleibestimmung in Kupferkonzentraten angewendet.
Summary A separation of small amounts of lead (0,2–5 mg) from great amounts of copper (200 mg) andiron (300 mg) has been elaborated. Lead together with copper and other elements is extracted with a chloroform solution of diethylammoniumdiethyldithiocarbamate from 1 N hydrochloric acid solution and afterwards lead is selectively re-extracted with 4 N hydrochloric acid. In this way it is separated also from other elements (Bi, Sb, Tl, Sn, Mo, As) interfering with the polarographic determination of lead in 2 N hydrochloric acid solution containing sodium hypophosphite. The method was applied to the determination of lead in copper concentrates.
  相似文献   

8.
Zusammenfassung Eine schnelle spektrochemische Methode zur Bestimmung von Mikrogramm-Mengen von Silber, Blei, Zinn, Arsen, Tellur und Wismut in Eisen und Stählen wurde ausgearbeitet. Die spektrographische Analyse wird nach dem Auflösen der Probe in Salpetersäure und dem Eindampfen der Lösung zur Trockne durchgeführt. Die Methode beruht auf der Anwendung eines Siliciumdioxid-Kaliumnitrat-Puffers, der die Verdampfung der zu bestimmenden Elemente erhöht und gleichzeitig die Verdampfung des Eisens so verzögert, daß seine Störung vollständig ausgeschaltet wird. Antimon(III)-oxid dient als innerer Standard. Genauigkeit und Reproduzierbarkeit sind gut.
Spectrochemical determination of trace elements in iron and steelPart 1. Application of a buffer
A spectrochemical method has been worked out for the rapid determination of microgram quantities of silver, lead, tin arsenic, tellurium and bismuth in iron and steel. The spectrographic analysis is carried out after dissolution of the sample in nitric acid and evaporation of the solution to dryness. The method makes use of a silicon dioxide/ potassium nitrate buffer which increases the volatility of the elements to be determined and at the same time causes such a delay in the volatility of iron that its interference is fully eliminated. Antimony(III) oxide serves as an internal standard. Accuracy and precision are good.


Die in der Literatur beschriebenen Verfahren zur spektrochemischen Bestimmung von Spurenelementen in Gußeisen und Stahl beruhen auf chemischer Voranreicherung nach Auflösen in Säure. Livic u. Mosova [3] fällen die Hydroxide mit Ammoniak und dampfen die Lösung zur Trockne ein. Aus dem Trockenrückstand werden Briketts von 6 mm gepreßt, die in 2 Stufen abgebrannt werden. Zur Bestimmung der leichtflüchtigen Spurenelemente wird das Brikett anodisch geschaltet, die entstehende Schmelze wird dann zur Bestimmung der schwerflüchtigen Komponenten als Kathode geschaltet. Die Bestimmungsgrenze liegt dabei je nach Element zwischen 2 · 10–3 und 5 · 10–4%.Balfour und andere [1] bestimmen Silber, Arsen, Wismut und andere Elemente in niedrig legierten Stählen und Eisenlegierungen durch Auflösen der Probe und Zugabe von Kupfernitrat als innerer Standard mit nachfolgender Behandlung der Lösung mit Schwefelwasserstoff. Der entstehende Niederschlag wird bei 500°C geglüht, in die Bohrung einer Graphitelektrode gebracht und im Gleichstrombogen von 5 A angeregt. Zur Aufnahme der Spektren dient ein hochauflösender Spektrograph.Ein komplizierterer chemischer Bearbeitungsgang wurde für ein Aerosol-Funken-Verfahren von Répás, Sajo u. Gegus [6] vorgeschlagen. Diese Autoren bestimmen Aluminium, Arsen, Blei, Wismut und Silber in Eisen und Stahl mit Bestimmungsgrenzen zwischen 2 · 10–3 und 1 · 10–4% bei Untergrundkorrektur. Das Verfahren erfordert eine Vorabtrennung von Kieselsäure und die Extraktion des Eisens.  相似文献   

9.
Zusammenfassung Zur Bestimmung von Zinn in armen Zinnerzen und deren Aufbereitungsabgängen wird folgender Weg vorgeschlagen:Die Kieselsäure des Roherzes wird vor einem Peroxidaufschluß mit Flußsäure abgeraucht und vorliegendes Eisen im wesentlichen als Eisenoxidaquat durch Filtration der alkalischen Aufschlußlösung entfernt. Der Rest des Eisens und alle weiteren Störelemente werden im ammoniakalischen Medium mit ÄDTA maskiert und das Zinn in Gegenwart von Beryllium mit Ammoniak als SnO2 · aq ausgefällt. Der Nederschlag wird in verd. Schwefelsäure aufgelöst und das Zinn als Zinn(IV) mit Phenylfluoron colorimetrisch bestimmt.Das angewandte Analysenverfahren ist frei von systematischen Fehlern und hat bei 95%iger statistischer Sicherheit einen Streubereich von ±0,006% (absolut) im Bereich von 0,0 bis wenigstens 0,5% Zinn.
Summary The following method is proposed for the determination of tin in poor tin ores and their dressing wastes: Silicic acid is removed from the raw ore by fuming with hydrofluoric acid, subsequently the sample is fused with sodium peroxide and iron is separated as Fe2O3 · aq by filtration of the alkaline solution of the decomposed material. Any residual iron and other interfering elements are masked by EDTA in ammoniacal medium and tin is precipitated as SnO2 · aq by ammonia in presence of beryllium. The precipitate is dissolved in diluted sulphuric acid and tin is determined as SnIV by colorimetry with phenylfluorone. The method is not liable to systematic errors. Having a confidence level of 95% the variation is ±0.006% (abs.) in the range of 0.0 to at least 0.5% of tin.


Diplomarbeit P. Gärtner 6.  相似文献   

10.
Zusammenfassung Es wird ein Analysenverfahren beschrieben, das es gestattet, in relativ kurzer Zeit eine genaue Spurenanalyse von Schwefel in Selen durchzufÜhren. Die Probe wird mit Salpetersäure oxydierend gelÖst. Die dabei entstehende Schwefelsäure wird durch zugefÜgtes Bariumchlorid als Bariumsulfat fixiert, während das als selenige Säure vorliegende Selen durch Eindampfen der LÖsung zur Trockne und Abrauchen entfernt wird. Das Bariumsulfat wird mit einer Mischung aus Zinn(II)-chlorid und konz. Phosphorsäure zu Schwefelwasserstoff reduziert. Der Schwefelwasserstoff wird in ZinkacetatlÖsung Übergetrieben, das Zinksulfid mit Dimethyl-p-phenylendiaminlÖsung zu Methylenblau umgesetzt und photometrisch bestimmt. Nach dieser Methode sind noch 2–10 ppm Schwefel in Selen bei einer Einwaage von 2 g zu bestimmen. Die aus Modellanalysen berechnete Standardabweichung beträgt bei 5 ppm Schwefel 0,6 ppm, was einer Varianz von 12% entspricht. Nach dieser Methode sind 0,5 ppm Schwefel noch nachweisbar. Der Zeitbedarf fÜr eine Bestimmung beträgt etwa 4–5 Std.
Summary A method is described for the rapid determination of traces of sulphur in selenium. The sample is oxidized by dissolution in nitric acid whereby sulphur is converted to sulphuric acid and selenium to selenous acid. Sulphate is then precipitated as BaSO4 and selenium is removed by evaporating to fumes. BaSO4 is reduced to hydrogen sulphide by a mixture of stannous chloride and conc. phosphoric acid, the H2S is passed into zinc acetate solution and the ZnS formed is determined photometrically by reaction with dimethyl-p-phenylendiamine to methylene blue. 1–20 ppm of sulphur can be determined in a sample of 2 g. The standard deviation is 0.6 ppm for 5 ppm of S, corresponding to a variation of 12%. The limit of detection is 0.5 ppm of S. The time required for a single determination is 4–5 hours.
  相似文献   

11.
Summary A simple method for the preparation of silica immobilized 8-hydroxyquinoline is described. The resulting material is investigated for its affinity to copper, nickel, cobalt, iron(III), manganese(II), chromium(III), zinc, cadmium, lead and mercury(II). The metal uptake capacities were found in the range from 0.2 to 0.7 mmol/g, the distribution ratios in the range from 1000 up to > 90000.
Synthese und Erprobung einer Metallsammelphase mit auf Kieselgel immobilisiertem 8-Hydroxychinolin
Zusammenfassung Eine einfache Methode zur Herstellung von an Kieselgelen immobilisiertem 8-Hydroxychinolin wird beschrieben. Das erhaltene Material wird hinsichtlich seiner Affinität für Kupfer, Nickel, Cobalt, Eisen (III), Mangan(II), Chrom(III), Zink, Cadmium, Blei und Quecksilber(II) untersucht. Die Metallkapazitäten liegen in der Größenordnung von 0,2–0,7 mmol/g, die Verteilungskoeffizienten in der Größenordnung 1000–>90000.
  相似文献   

12.
Zusammenfassung Zur Trennung von Tellur aus Lösungen mit komplizierter Zusammensetzung wurde eine kombinierte Extraktionsmethode entwickelt. Die Extraktion von Eisen(III), Arsen(V), Antimon(V), Gold(III), Thallium(III), Wismut(III), Zinn(IV) und Selen(IV) erfolgt mit Diisopropyläther aus 8 M Salzsäure, wobei das gesamte Te(IV) in der wäßrigen Phase verbleibt. Diese wird dann mit Methylisobutylketon aus 4 M Salzsäure extrahiert, während in der wäßrigen Phase Kupfer(II), Aluminium(III), Silber(I), Nickel (II), Kobalt(II), Zink(II), Cadmium(II) und Blei(II) verbleiben. Die vollständige Abtrennung der Begleitelemente des Tellurs erfolgt durch zusätzliche Extraktion ihrer Kupferronate mit Methylisobutylketon bei pH 3–5. Das vorgeschlagene Extraktionsverfahren kann mit jeder bekannten Methode zur Bestimmung geringer Tellurmengen kombiniert werden.
Extraction method for the separation of small quantities of tellurium from accompanying elements
A new combined solvent extraction method is proposed for the separation of tellurium from solutions of complex composition. Iron(III), arsenic(V), antimony(V), gold(III), thallium(III)J bismuth(III), tin(IV) and selenium(IV) are extracted with diisopropyl ether from 8 M hydrochloric acid. Under these conditions tellurium(IV) is quantitatively retained in the aqueous phase. Subsequently tellurium(IV) is extracted from 4 M hydrochloric acid with methylisobutyl ketone, so that copper(II), aluminium(III), silver(I), nickel(II), cobalt(II), zink(II), cadmium(II) and lead(II) remain in. the aqueous phase. The complete separation of the accompanying elements is realized by an additional extraction of their cupferronates with methylisobutyl ketone at pH 3–5. The separation described can be combined with any known method for the determination of small amounts of tellurium(IV).
  相似文献   

13.
Zusammenfassung Aus an sich im Makromaßstab bekannten Einzelschritten zur Mineralisation zinnorganischer Verbindungen und zur komplexometrischen Bestimmung von Zinn(IV) wurde eine Mikrobestimmung von Zinn in nieder- und hochmolekularen Organozinnverbindungen entwickelt.Die Mineralisierung der zu analysierenden Verbindung erfolgt mit einer Mischung aus konz. Schwefelsäure und konz. Salpetersäure unter Zusatz von Perchlorsäure. Die Bestimmung des Zinn(IV) erfolgt durch Komplexierung mit einem Überschuß an ÄDTA und Rücktitration mit 0,01 N Kupfer(II)-nitratlösung gegen Naphthylazoxin-S als Metallindicator.An Hand von Beleganalysen wird gezeigt, daß bei Einwaagen zwischen 0,025 und 0,07 mMol zinnorganischer Verbindung mit einer relativen Standardabweichung von rund 0,4% zu rechnen ist.
Microdetermination of tin in low and high molecular weight organotin compounds
A procedure has been developed combining the two steps of mineralization of the compound and complexometric titration of tin(IV), known from macroscale analysis.Mineralization is effected by a mixture of conc. sulphuric acid, conc. nitric acid and perchloric acid. The tin(IV) is determined by complexing it with an excess of EDTA and by back-titration with 0.01 N copper(II) nitrate using naphthyl azoxine S as complexometric indicator.Results of test analyses are given showing the relative standard deviation to be about 0.4% with samples containing 0.025 to 0.07 mMol of organotin compound.


Neue Anschrift: Chemische Werke Hüls AG 437 Marl, Westfalen.  相似文献   

14.
Summary An amperometric determination of tin with potassium dichromate has been described. The advantage of the cathodic polarograms of Cr2O2 7- and Sn2+ in formate media was taken and titrations were performed at –0.8 V vs. S.C.E. at pH 3.0. It is shown that tin upto 10 mg may be determined accurately within the limits of experimental errors.
Zusammenfassung Eine Methode wird beschrieben zur amperometrischen Bestimmung von Zinn mit Kaliumdichromat unter Ausnutzung des kathodischen Polarogramms von C2O7 2– und Sn2+. Die Titration wird bei –0,8 V (gegen S.K.E.) und PH 3,0 ausgeführt. Zinn kann in Mengen bis zu 10 mg mit guter Genauigkeit bestimmt werden. Die Fehler liegen inner-halb der experimentellen Grenzen.
  相似文献   

15.
Zusammenfassung Eine reduktive automatisierte Bestimmungsmethode von ppm Schwefel in organischen Substanzen wird vorgeschlagen. Die Substanz wird im Wasserstoffstrom in einem weiten Rohr über Quarzwolle bei einer Temperatur von 1050°C hydriert. Der Schwefelwasserstoff wird in 1-m KOH und 1,5-m Hydroxylamin absorbiert und sofort in dieser Lösung mit einer 2 · 10–4-m Blei(II)maßlösung titriert. Die Titration wird mit einer ionenspezifischen Elektrode verfolgt und bei einem vorher gewählten Potentialwert beendet. Ein System, bei dem die Titrantzugabe proportional der Abweichung vom erwünschten Endpunktsignal ist, ermöglicht eine Bestimmungsdauer von 5–6 min, unabhängig von der vorgelegten Menge Schwefel. Die Standardabweichung der Bestimmung von mehr als 5 ppm S ist durchschnittlich besser als 3 % rel. Stickstoffhaltige Substanzen stören erst in größeren Mengen.
The determination of sulphur in organic substances. IV
Summary A reductive automated method for the determination of a few p. p. m. S in organic compounds is proposed. The sample is hydrogenated in a wide tube in a stream of hydrogen at a temperature of about 1050° C over quartz wool. The resulting hydrogensulfide is absorbed in a solution of 1 M KOH and 1.5 M hydroxylamine and immediately titrated with a 2 · 10–4 M lead (II)-titrant solution. The titration is automatically carried out until the preset signal of an ion selective electrode is reached. A system, in which the titrant flow is proportional to the difference between the actual signal and the preset value, enables a total time of analysis of about 5–6 min. This time depends not on the quantity of sulfur to be determined. The standard deviation of the determination of more than 5 p. p. m. is better than 3% rel. as a mean value. Nitrogen containing compounds interfere only in large amounts.
  相似文献   

16.
Summary The electrothermal atomization of lead has been investigated for accurate determination of lead in water samples. Thiourea served to lower the atomization temperature of lead and to eliminate the interferences from chloride matrix. The addition of thiourea also allowed the accurate determination of lead irrespective of its chemical form. The absolute sensitivity (1% absorption) was 1.1 × 10–12g of lead. The method permits the direct rapid determination of lead in water samples including sea water.
Bestimmung von Blei in Wässern durch Atomabsorptions-Spektrometrie mit elektrothermischer Atomisierung
Zusammenfassung Zur Verringerung der Atomisie-rungstemperatur und zur Beseitigung von Störungen durch die Chloridmatrix wird ein Zusatz von Thioharnstoff empfohlen. Dieser Zusatz gestattet außerdem eine genaue Bestimmung unabhängig von der chemischen Form, in der das Blei vorliegt. Die absolute Empfindlichkeit (1% Absorption) beträgt 1,1 · 10–12 g Pb. Das Verfahren wurde zur direkten Bleibestimmung in Wässern, einschl. Meereswasser, angewendet.
  相似文献   

17.
Zusammenfassung Zwecks Bestimmung kleiner Gehalte von Thallium in Blei wird das Thallium als Thallium(III)-chlorid aus der mit Brom oxydierten Lösung mittels Isopropyläther extrahiert und jodometrisch titriert. Gehalte von 0,05–1% in Blei lassen sich mit einer Genauigkeit von –0,5% bestimmen.  相似文献   

18.
Summary Serious systematic errors inherent in the determination of lead in geological and biological samples by flameless atomic-absorption spectrometry are demonstrated. The reduced absorption of lead is due to partial interaction with alkaline, alkaline-earth and iron chlorides during the atomization stage. Incomplete dissociation of the volatile monochloride of lead in the gaseous phase reduces the absorption signal. An addition of 20% hydrogen to nitrogen (purge gas) diminishes signal suppression by removing the chlorine in form of volatile HCl. The detection limit is about 0.6 ppm in rocks and about 0.3 ppm in plant materials. Depending on the content in the samples the relative standard deviation is between 1 and 12%. The accuracy of the method was tested on 39 international standard reference samples.
Bestimmung von Blei in geologischen und biologischen Materialien durch AAS mit der Graphitrohrküvette
Zusammenfassung Schwerwiegende systematische Fehler bei der Bestimmung von Blei in geologischen und biologischen Materialien mit der Graphitrohrküvette werden aufgezeigt. Die Reaktion von Blei mit Alkali-, Erdalkali- und Eisenchloriden während der Atomisierungsphase führt zur Bildung von Bleimonochlorid, das nur unvollständig dissoziiert und eine Signalunterdrückung zur Folge hat. Ein Zusatz von 20% Wasserstoff zu Stickstoff als Spülgas vermindert die Signalunterdrückung, indem überschüssiges Chlor als Chlorwasserstoff entfernt wird. Die Nachweisgrenze liegt bei ca. 0,6 ppm für Gesteine und bei ca. 0,3 ppm für Pflanzenmaterialien. Je nach der Konzentration beträgt die relative Standardabweichung 1–12%. Die Genauigkeit der Methode wurde an 39 internationalen Standardreferenzproben überprüft.
  相似文献   

19.
Summary A combined anion-exchange-spectrophotometric method has been worked out for the determination of titanium in biological materials. The sample is dry-ashed at 420°C. The ash (ca. 0.5 g) is then decomposed with a mixture of nitric, perchloric and hydrofluoric acids, and is finally taken up in hydrochloric acid. The titanium is collected by anion-exchange on an Amberlite CG 400 (SCN) column from 1 M thiocyanate — 1 M hydrochloric acid solution and eluted with 4 M hydrochloric acid. Titanium is subsequently determined spectrophotometrically with diantipyrylmethane. Results of the determination of titanium in various materials of biological origin and in two NBS standard biological samples are compiled. Standard deviations are in the range of 3–9% (2.4% in synthetic mixtures).
Spurenbestimmung von Titan in biologischem Material durch Kombination von Anionenaustauscher-Trennung und Spektralphotometrie
Zusammenfassung Bei der vorgeschlagenen Methode wird die Probe bei 420° C trocken verascht, die Asche mit einer Mischung von Salpeter-, Perchlor- und Flußsäure aufgeschlossen und in Salzsäure aufgenommen. Titan wird dann aus 1 M Thiocyanat-Salzsäurelösung an dem Anionenaustauscher Amberlite CG 400 (SCN) adsorbiert und mit 4M Salzsäure eluiert. Danach erfolgt die spektralphotometrische Bestimmung mit Diantipyrylmethan. Das Verfahren wurde auf synthetische Gemische, verschiedenartige biologische Materialien und zwei NBS-Standardsubstanzen angewendet. Die Standardabweichungen liegen im Bereich von 3–9% (2,4% für synthetische Gemische).
  相似文献   

20.
Zusammenfassung Eine Methode wird beschrieben, die die kathodenstrahlpolarographische Bestimmung von Spuren Ni, Pb, Mn, Co, Cu, Fe, Mo in Zinnchloriden in den Bereichen 10–4% (Ni, Pb, Mn, Cu, Fe) und 10–5% (Mo, Co) gestattet. Über den stark basischen Anionenaustauscher AG 1×8 wird das Zinn von den Spurenelementen getrennt.
Cathode-ray polarographic determination of trace elements in tin chlorides
A method is described for the cathode-ray polarographic detemination of traces of Ni, Pb, Mn, Co, Cu, Fe, and Mo in tin chlorides. Tin is separated from the trace metals by ion exchange on the strong basic anion-exchange resin AG 1×8. The detection limits are within the ranges of 10–4% and 10–5%.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号