首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 740 毫秒
1.
Trifluoroacetic acid (TFA) remains the dominant mobile phase additive for reversed-phase high-performance liquid chromatography (RP-HPLC) of peptides after more than two decades since its introduction to this field. Generally, TFA has been employed in a concentration range of 0.05-0.1% (6.5-13 mM) for the majority of peptide separations. In order to revisit the question as to whether such a concentration range is optimum for separations of peptide mixtures containing peptides of varying net positive charge, the present study examined the effect of varying TFA concentration on RP-HPLC at 25 and 70 degrees C of three groups of synthetic 10-residue synthetic peptides containing either one (+1) or multiple (+3, +5) positively charged groups. The results show that the traditional range of TFA concentrations employed for peptide studies is not optimum for many, perhaps the majority, of peptide applications. For efficient resolution of peptide mixtures, particularly those containing peptides with multiple positive charges, our results show that 0.2-0.25% TFA in the mobile phase will achieve optimum resolution. In addition, the use of high temperature as a complement to such TFA concentration levels is also effective in maximizing peptide resolution.  相似文献   

2.
Scriba GK 《Electrophoresis》2003,24(22-23):4063-4077
The present review summarizes peptide enantioseparations by capillary electrophoresis with the focus on recent developments. These include the application of new chiral selectors and systematic studies involving series of di- and tripeptides with either common features or with a variety of structures. One section emphasizes mechanistic aspects of the migration order of the enantiomers in cyclodextrin-assisted chiral separations with respect to the complexation constants and the mobilities of the transient diastereomeric complexes. In addition, short paragraphs on the application of chiral capillary electrophoresis to the determination of the stereochemical purity of peptidomimetics and on chiral separations of peptides by capillary electrochromatography have also been included.  相似文献   

3.
4.
In order to characterize the effect of temperature on the retention behaviour and selectivity of separation of polypeptides and proteins in reversed-phase high-performance liquid chromatography (RP-HPLC), the chromatographic properties of four series of peptides, with different peptide conformations, have been studied as a function of temperature (5-80 degrees C). The secondary structure of model peptides was based on either the amphipathic alpha-helical peptide sequence Ac-EAEKAAKEX(D/L)EKAAKEAEK-amide, (position X being in the centre of the hydrophobic face of the alpha-helix), or the random coil peptide sequence Ac-X(D/L)LGAKGAGVG-amide, where position X is substituted by the 19 L- or D-amino acids and glycine. We have shown that the helical peptide analogues exhibited a greater effect of varying temperature on elution behaviour compared to the random coil peptide analogues, due to the unfolding of alpha-helical structure with the increase of temperature during RP-HPLC. In addition, temperature generally produced different effects on the separations of peptides with different L- or D-amino acid substitutions within the groups of helical or non-helical peptides. The results demonstrate that variations in temperature can be used to effect significant changes in selectivity among the peptide analogues despite their very high degree of sequence homology. Our results also suggest that a temperature-based approach to RP-HPLC can be used to distinguish varying amino acid substitutions at the same site of the peptide sequence. We believe that the peptide mixtures presented here provide a good model for studying temperature effects on selectivity due to conformational differences of peptides, both for the rational development of peptide separation optimization protocols and a probe to distinguish between peptide conformations.  相似文献   

5.
Mixed-mode hydrophilic interaction/cation-exchange chromatography (HILIC/CEX) is a novel high-performance technique which has excellent potential for peptide separations. Separations by HILIX/CEX are carried out by subjecting peptides to linear increasing salt gradients in the presence of high levels of acetonitrile, which promotes hydrophilic interactions overlaid on ionic interactions with the cation-exchange matrix. In the present study, HILIC/CEX has been compared to reversed-phase liquid chromatography (RP-HPLC) for separation of mixtures of diastereomeric amphipathic alpha-helical peptide analogues, where L- and D-amino acid substitutions were made in the centre of the hydrophilic face of the amphipathic alpha-helix. Unlike RP-HPLC, temperature had a substantial effect on HILIC/CEX of the peptides, with a rise in temperature from 25 to 65 degrees C increasing the retention times of the peptides as well as improving resolution. Our results again highlight the potential of HILIC/CEX as a peptide separation mode in its own right as well as an excellent complement to RP-HPLC.  相似文献   

6.
Weak anion-exchange and reversed-phase high-performance liquid chromatographic methods for peptide separations were compared using a tryptic digest of "rat small myelin basic protein". In these experiments, a number of tryptic peptides that were not resolved on the reversed-phase column could be separated on the weak anion-exchange column, and in other instances, as might be expected, reversed-phase chromatography provided better resolution of certain peptides than did the weak anion-exchange method. The results obtained strongly suggest that the combined use of these two methods of separation, which utilize different selectivities, can provide an excellent improvement in resolving power for a number of peptide separations.  相似文献   

7.
8.
A polyacrylate-based monolithic column bearing cationic functionalities and designed for capillary electrochromatography (CEC) has been prepared via photopolymerization of a mixture of hexyl acrylate, butanediol diacrylate, 2-(acryloyloxy) ethyltrimethyl ammonium chloride (monomers), azobisisobutyronitrile (photoinitiator), acetonitrile, phosphate buffer, and ethanol (porogens). The polymerization process was initiated with UV light at 360 nm. The column performance was evaluated via the separations of alkylbenzenes, substituted anilines, basic drugs, peptides, and a protein digest. The separation of complex peptide mixtures was then studied since such separations constitute a promising application of capillary electrochromatography. In particular, the effects of mobile phase composition, including ionic strength of the buffer solution and the percentage of acetonitrile on the retention factor, the column efficiency, and the resolution were determined. The separations were affected by both interaction of the peptides with the stationary phase and their own electrophoretic mobility. Excellent separations with column efficiencies of up to 160 000 plates/m were achieved for both a mixture of ten well-defined peptides and a tryptic digest of cytochrome c. The fractions of eluent containing peptides of the digest separated in the monolithic column were collected and characterized using matrix-assisted laser desorption ionization mass spectrometry.  相似文献   

9.
In an ongoing effort to understand the effect of varying reversed-phase high-performance liquid chromatography (RP-HPLC) parameters on the retention behaviour of peptides, necessary for the rational development of separation/optimization protocols, we believe it is important to delineate the contribution of alpha-helical structure to the selectivity of peptide separations. The present study reports the effects of varying column packing, mobile phase conditions and temperature on RP-HPLC retention behaviour at pHs 2.0 and 7.0 of peptides based on the amphipathic peptide sequence Ac-EAEKAAKEXEKAAKEAEK-amide (with position X in the centre of the hydrophobic face of the alpha-helix), where position X is substituted by L- or D-amino acids. At pH 2.0, an increase in trifluoroacetic acid concentration or the addition of sodium perchlorate to a phosphoric acid-based mobile phase had the similar effect of improving peak shape as well as increasing peptide retention time due to ion-pairing effects with the positively-charged peptides; in contrast, at pH 7.0, the addition of salt had little effect save an improvement in peak shape. Temperature was shown to have a complex influence on peptide selectivity due to varying effects on peptide conformation. In addition, subtle effects on peptide selectivity were also noted based on the column packings employed at pHs 2.0 and 7.0.  相似文献   

10.
Recent developments in CE and CEC of peptides   总被引:1,自引:0,他引:1  
Kasicka V 《Electrophoresis》2008,29(1):179-206
  相似文献   

11.
Capillary separations interfaced to tandem mass spectrometry provide a very powerful tool for the characterization of biological macromolecules such as proteins and peptides. The development of real time data-dependent data acquisition has further enhanced the capability of this method. However, the application of this technique to fast capillary separations has been limited by the relatively slow spectral acquisition speed available on scanning mass spectrometers. In this work, an ion trap storage/reflectron time-of-flight mass spectrometer (IT/reTOF-MS) has been used as an on-line tandem mass detector for capillary high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) separations of peptide mixtures including a protein digest. By taking advantage of the nonscanning property of the time-of-flight mass spectrometer, a fast spectral acquisition rate has been achieved. This fast spectral acquisition rate, combined with a new protocol that speeds up tickle voltage optimization, has provided MS/MS spectra for multiple components in a hemoglobin digest during one liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) run. Further, the IT/reTOF-MS has the speed to provide MS/MS spectra for multiple components in a CE separation of a synthetic peptide mixture within one CE/MS/MS run.  相似文献   

12.
13.
Capillary electroendoosmotic chromatography of peptides   总被引:1,自引:0,他引:1  
This review focuses on the current state of peptide separation by capillary electroendoosmotic chromatography (CEC). When carried out under optimised conditions, peptide separation by CEC methods represents an orthogonal and complementary technique to micro-HPLC (micro-HPLC) and high-performance capillary zone electrophoresis (HPCZE). The origin of the selectivity differences that can be achieved with these three separation techniques (CEC, micro-HPLC and HPCZE), respectively are discussed, and the current limits of performance with CEC methods documented. Peptide separations by CEC methods with n-alkyl bonded silicas or mixed-mode phases are also illustrated. The development of different variants of CEC and pressurised CEC (also commonly referred to in the literature as electrically-assisted micro-HPLC) are examined. The potential of coupling CEC systems to mass spectrometers for real-time analyses of peptides or protein digests has been examined. Several future directions for the application of this technique in phenotype/proteomic and zeomic mapping of naturally occurring peptides and proteins are highlighted.  相似文献   

14.
15.
Chromatographic protein and peptide separation technologies enable comprehensive proteomic analysis of plasma and other complex biological samples by mass spectrometry. However, as the number of separations and/or fractions increases, so does the number of peptides split across fraction boundaries. Irreproducibility of peptide chromatographic separation results in peptides on or near the boundary moving partially or entirely into adjacent fractions. Peptide shifting across fraction boundaries increases the variability of measured peptide abundance, and so there is a trade-off between proteomic comprehensiveness using separation technologies and accurate quantitative proteomic measurements. In this paper, a method for detecting and correcting split peptides, called Peptide Shifter, is introduced and evaluated. An essential component of Peptide Shifter is a global peptide expression profile analysis that allows the inference of the underlying peptide shift pattern without the use of peptide labeling or internal standards. A controlled proteomic analysis of plasma samples demonstrates a 34% decrease in peptide intensity variability after the application of Peptide Shifter.  相似文献   

16.
Summary We have determined the interaction behaviour of peptides with hydrophobic stationary phases on analytical columns using isnocratic or shallow gradient elution for the purpose of developing procedures for rapid optimization of conditions for preparative reversed-phase chromatography of peptides. From our investigation of the separation of two closely related decapeptides (differing by one methyl group), in a 1:1 molar ratio on an analytical C8 column, we have found that shallow gradients of 0.1% acetonitrile/min appeared to be the best compromise between resolution and a practical run time for preparative peptide separations. Up to 20mg of the two-peptide mixture was efficiently resolved on the analytical column, with >97% recovery of homogeneous peptides.  相似文献   

17.
We recently introduced a mixed-mode reversed-phase/weak anion-exchange type separation material based on silica particles which consisted of a hydrophobic alkyl strand with polar embedded groups (thioether and amide functionalities) and a terminal weak anion-exchange-type quinuclidine moiety. This stationary phase was designed to separate molecules by lipophilicity and charge differences and was mainly devised for peptide separations with hydroorganic reversed-phase type elution conditions. Herein, we demonstrate the extraordinary flexibility of this RP/WAX phase, in particular for peptide separations, by illustrating its applicability in various chromatographic modes. The column packed with this material can, depending on the solute character and employed elution conditions, exploit attractive or repulsive electrostatic interactions, and/or hydrophobic or hydrophilic interactions as retention and selectivity increments. As a consequence, the column can be operated in a reversed-phase mode (neutral compounds), anion-exchange mode (acidic compounds), ion-exclusion chromatography mode (cationic solutes), hydrophilic interaction chromatography mode (polar compounds), and hydrophobic interaction chromatography mode (e.g., hydrophobic peptides). Mixed-modes of these chromatographic retention principles may be materialized as well. This allows an exceptionally flexible adjustment of retention and selectivity by tuning experimental conditions. The distinct separation mechanisms will be outlined by selected examples of peptide separations in the different modes.  相似文献   

18.
High-performance liquid chromatography (HPLC) is widely used for separation of complex peptide mixtures before mass spectrometry-based proteome analysis. In this analysis, reversed phase HPLC (RPHPLC) using non-polar stationary phases such as surface-modified silica containing alkyl groups (e.g., C18) is typically employed. Because of the high heterogeneity of proteomic samples, multidimensional separation approaches gained increasing attention recently to tackle this complexity and extremely high range of concentrations. In two-dimensional liquid chromatography, hydrophilic interaction chromatography (HILIC) is often a method of choice for combination with RP-HPLC because it uses reversed-phase type eluents and allows efficient separation of polar peptides. Due to the high degree of orthogonality in this two-dimensional separation space, it is tempting to develop approaches for predicting peptide retention times for HILIC-based separations similar to the ones for RP-HPLC. Recent successful efforts in this area were focused on developing retention coefficient (RC)-based approaches. Herein, we explored the feasibility of using a statistical thermodynamic model for prediction of peptide retention times in HILIC separations and determined the phenomenological parameters of the model for a bare silica column. The performance of the developed model was tested using HPLC-MS analysis of a set of synthetic peptides, as well as a tryptic peptide mixture.  相似文献   

19.
The previously reported COmbined FRActional DIagonal Chromatography (COFRA-DIC) methodology, in which a subset of peptides representative for their parent proteins are sorted, is particularly powerful for whole proteome analysis. This peptide-centric technology is built around diagonal chromatography, where peptide separations are crucial. This paper presents high efficiency peptide separations, in which four 250 x 2.1 mm, 5 microm Zorbax 300SB-C18 columns (total length 1 m) were coupled at operating temperatures of 60'C using a dedicated LC oven and conventional LC equipment. The high efficiency separations were combined with the COFRADIC procedure. This extremely powerful combination resulted, for the analysis of serum, in an increase in the uniquely identified peptide sequences by a factor of 2.6, compared to the COFRADIC procedure on a 25 cm column. This is a reflection of the increased peak capacity obtained on the 1 m column, which was calculated to be a factor 2.7 higher than on the 25 cm column. Besides more efficient sorting, less ion suppression was noticed.  相似文献   

20.
In this article, the effects of the stationary phase, buffer pH, organic modifier type, organic modifier composition, applied voltage, and temperature on the migration of several synthetic peptides in etched chemically modified open-tubular capillaries are discussed. With these solutes, migration is due to two effects: electrophoretic mobility and solute/bonded phase interactions. In addition, relative migration rates are evaluated for the peptide samples as a function of these experimental variables in order to determine which parameters might be useful for optimizing separations in open-tubular capillary electrochromatography (OTCEC). Some examples of synthetic peptide separations are presented where the sample contains a major component and several minor species, demonstrating how the resolution of these mixtures can be affected by the appropriate choice of experimental variables.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号