共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, rapid and specific chemiluminescence (CL) method for the determination of glutathione has been developed. The method
is based on the enhanced CL of the reaction between Ru(phen)3
2+ (phen = 1,10-phenanthroline) and KMnO4 by glutathione in HCl medium. Under the optimum conditions, the response is linearly proportional to the concentration of
glutathione between 1.5 × 10−7 and 1.0 × 10−5 mol L−1. The dection limit for glutathione (5.8 × 10−8 mol L−1) is about 10 and 200 times better than those of the spectrophotometric method using Ellman regent and the Lucigenin – CL
method, respectively. The final procedure allows the determination of glutathione in human serum with recoveries of 92%–108%.
A satisfactory agreement was obtained with a mean relative difference of 2.5% compared to the HPLC method. 相似文献
2.
Gongjun Yang Xilong Qu Ming Shen Chengyin Wang Qishu Qu Xiaoya Hu 《Mikrochimica acta》2008,160(1-2):275-281
Poly(phenol red) (denoted as PPR) films were electrochemically synthesized on the surface of a glassy carbon electrode (GCE)
by cyclic voltammetry to obtain a chemically modified electrode (denoted as PPR-GCE). The growth mechanism of PPR films was
studied by attenuated total reflection spectroscopy. This PPR-GCE was used to develop a novel and reliable method for the
determination of trace Pb2+ by anodic stripping differential pulse voltammetry. At optimum conditions, the anodic peak exhibits a good linear concentration
dependence in the range from 5.0 × 10−9 to 5.0 × 10−7 mol L−1 (r = 0.9989). The detection limit is 2.0 × 10−9 mol L−1 (S/N = 3). The method was employed to determine trace levels of Pb2+ in industrial waste water samples.
Correspondence: Gongjun Yang, Ming Shen, College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002,
P.R. China 相似文献
3.
Determination of the effective components in traditional Chinese medicine is one of the key steps for its identification.
In this paper a novel and sensitive chemiluminescence (CL) method for the determination of rhein coupled with flow-injection
analysis (FIA) is developed. It is based on the strong sensitizing effect on the weak CL reaction between luminol and ferricyanide
in alkaline solution. Under optimal experimental conditions, the relative CL intensity is proportional to the concentration
of rhein in the range of 7.0 × 10−12–7.0 × 10−10 mol L−1 and 1.0 × 10−9–4.0 × 10−5 mol L−1, the detection limit is 1.478 × 10−13 mol L−1, and the relative standard deviation (RSD) for 9 parallel measurements of 1.408 × 10−7 mol L−1 rhein is 3.4%. The method was successfully applied to the determination of rhein in pharmaceutical preparations. The possible
mechanism of CL is also briefly discussed. 相似文献
4.
The electrooxidative behaviour and determination of quetiapine (QTP), a dibenzothiazepine derivative and antipsychotic agent,
on a glassy carbon disc electrode was investigated using cyclic (CV), linear sweep (LSV), differential pulse (DPV) and Osteryoung
square wave voltammetry (OSWV). Fully validated DP and SW voltammetric procedures are described for the determination of QTP.
QTP in pH 3.5 acetate buffer solution presents a well-defined anodic response, studied by the proposed methods. This main
response was due to the irreversible, diffusion-controlled, one-electron and one-proton oxidation of the aliphatic nitrogen
of the piperazine ring. Under optimal conditions, a detection limit of 4.0 × 10−8 mol L−1 for DPV and 1.33 × 10−7 mol L−1 for OSWV, and a linear calibration graph in the range from 4.0 × 10−6 to 2.0 × 10−4 mol L−1 were obtained for both methods. The procedure was successfully applied to the determination of the drug in tablets, human
serum and human urine with good recoveries. The detection limits were 6.20 × 10−7 mol L−1 and 5.92 × 10−7 mol L−1 in human serum and 1.44 × 10−7 mol L−1 and 1.31 × 10−6 mol L−1 in human urine, for the DPV and OSWV method, respectively. 相似文献
5.
Pyrene-tetramethylpiperidinyl (Pyr-Tempo) as a spin label fluorescent probe for iron(II) was synthesized. It exhibited weak
fluorescence (λexc/λem = 346/399 nm) in aqueous solution due to an intramolecular quenching pathway. A method for determination of iron(II) was
proposed based on the fluorescence enhancement of the probe in the presence of iron(II) in acidic medium. Under optimum conditions,
the fluorescence enhancement of Pyr-Tempo is linearly proportional to the iron(II) concentration range of 6.0 × 10−8 to 9.6 × 10−6 mol L−1 with a detection limit of 8.0 × 10−9 mol L−1. The relative standard deviation (RSD) of six replicate measurements is 1.95% for 3.0 × 10−7 mol L−1 iron(II). The developed spin label fluorescence probe is found to be rapidly and sensitively responsive to iron(II) with
high selectivity compared to existing fluorescence methods. The proposed method was successfully applied to iron(II) detection
in five real samples with satisfactory results obtained by manual UV/Vis spectrophotometry (standard method) with 1,10-phenanthroline. 相似文献
6.
Utilizing the fascinating properties of montmorillonite calcium (MMT-Ca), such as huge cationic exchange capacity, strong
adsorptive ability, high chemical and mechanical stability, an MMT-Ca modified carbon paste electrode (CPE) was constructed
for the sensitive determination of Pb2+. In 0.01 mol·L−1 HCl, Pb2+ was firstly exchanged and accumulated on an MMT-Ca modified CPE surface and secondly reduced to Pb at −0.90 V. In the following
potential sweep from −0.90 to −0.50 V, reduced Pb was oxidized, resulting in an obvious stripping peak at −0.58 V. After optimizing
the parameters, such as determining medium, content of MMT-Ca, accumulation potential and time, an electrochemical method
was developed for the analysis of Pb2+. Compared with bare CPE, the MMT-Ca modified CPE significantly enhances the sensitivity of Pb2+ analysis. The limit of detection is evaluated to be 6.0 × 10−9 mol L−1 Pb2+. Finally, this method was successfully employed to determine trace levels of Pb2+ in water samples.
The first two authors contribute equally do this work 相似文献
7.
A novel L-cysteine film modified electrode has been fabricated by means of an electrochemical oxidation procedure, and it
was successfully applied to the electrochemical determination of acetaminophen. This method utilizes the electrooxidation
of amines to their analogous cation radicals to form a chemically stable covalent linkage between the nitrogen atom of the
amine and edge plane sites at the glassy carbon electrode surface. The electrochemical behaviour of acetaminophen at the film
electrode was investigated in 0.1 mol L−1 phosphate buffer (pH 6.20). It was found that the redox peak current of acetaminophen was enhanced greatly on the film electrode.
Linearity between the oxidation peak current and the acetaminophen concentration was obtained in the range of 1.0 × 10−4–2.0 × 10−7 mol L−1 with a detection limit of 5.0 × 10−8 mol L−1. For seven parallel detections of 1.0 × 10−5 mol L−1 acetaminophen, the relative standard deviation (RSD) was 1.46%, suggesting that the film electrode has excellent reproducibility.
Application to the determination of acetaminophen in drug tablets and human urine demonstrated that the film electrode has
good stability and high sensitivity. 相似文献
8.
Jun Yue Bai Liang Wang Hong Jing Wang Peng Fei Huang Yu Qing Zhao Sheng Di Fan 《Mikrochimica acta》2006,156(3-4):321-326
The electrochemical behavior of epinephrine (EP) at a mercaptoacetic acid (MAA) self-assembled monolayer modified gold electrode
was studied. The MAA/Au electrode is demonstrated to promote the electrochemical response of epinephrine by cyclic voltammetry.
The possible reaction mechanism is also discussed. The diffusion coefficient D of EP is 6.85 × 10−6 cm2 s−1. In 0.1 mol L−1 phosphate buffer (pH 7.20), a sensitive oxidation peak was observed at 0.177 V, and the peak current is proportional to the
concentration of EP in the range of 1.0 × 10−5–2.0 × 10−4 mol L−1 and 1.0 × 10−7–1.0 × 10−6 mol L−1. The detection limit is 5 × 10−8 mol L−1. The modified electrode is highly stable and can be applied to the determination of EP in practical injection samples. The
method is simple, quick, sensitive and accurate. 相似文献
9.
Sensitive fluorescent probes for determination of hydrogen peroxide and glucose based on enzyme-immobilized magnetite/silica nanoparticles 总被引:2,自引:0,他引:2
Qing Chang Lihua Zhu Guodong Jiang Heqing Tang 《Analytical and bioanalytical chemistry》2009,395(7):2377-2385
Sensitive fluorescent probes for the determination of hydrogen peroxide and glucose were developed by immobilizing enzyme
horseradish peroxidase (HRP) on Fe3O4/SiO2 magnetic core–shell nanoparticles in the presence of glutaraldehyde. Besides its excellent catalytic activity, the immobilized
enzyme could be easily and completely recovered by a magnetic separation, and the recovered HRP-immobilized Fe3O4/SiO2 nanoparticles were able to be used repeatedly as catalysts without deactivation. The HRP-immobilized nanoparticles were able
to activate hydrogen peroxide (H2O2), which oxidized non-fluorescent 3-(4-hydroxyphenyl)propionic acid to a fluorescent product with an emission maximum at 409 nm.
Under optimized conditions, a linear calibration curve was obtained over the H2O2 concentrations ranging from 5.0 × 10−9 to 1.0 × 10−5 mol L−1, with a detection limit of 2.1 × 10−9 mol L−1. By simultaneously using glucose oxidase and HRP-immobilized Fe3O4/SiO2 nanoparticles, a sensitive and selective analytical method for the glucose detection was established. The fluorescence intensity
of the product responded well linearly to glucose concentration in the range from 5.0 × 10−8 to 5.0 × 10−5 mol L−1 with a detection limit of 1.8 × 10−8 mol L−1. The proposed method was successfully applied for the determination of glucose in human serum sample. 相似文献
10.
Xiaoying Liu Yonghong Li Xinsheng Liu Xiandong Zeng Bo Kong Shenglian Luo Wanzhi Wei 《Journal of Solid State Electrochemistry》2012,16(3):883-889
A simple sensor based on bare carbon ionic liquid electrode was fabricated for simultaneous determination of dihydroxybenzene
isomers in 0.1 mol L−1 phosphate buffer solution (pH 6.0). The oxidation peak potential of hydroquinone was about 0.136 V, catechol was about 0.240 V,
and resorcinol 0.632 V by differential pulse voltammetric measurements, which indicated that the dihydroxybenzene isomers
could be separated absolutely. The sensor showed wide linear behaviors in the range of 5.0 × 10−7–2.0 × 10−4 mol L−1 for hydroquinone and catechol, 3.5 × 10−6–1.535 × 10−4 mol L−1 for resorcinol, respectively. And the detection limits of the three dihydroxybenzene isomers were 5.0 × 10−8, 2.0 × 10−7, 5.0 × 10−7 mol L−1, respectively (S/N = 3). The proposed method could be applied to the determination of dihydroxybenzene isomers in artificial wastewater and
the recovery was from 93.9% to 104.6%. 相似文献
11.
A self-assembled electrode with a meso-2,3-dimercaptosuccinic acid (DMSA) monolayer has been characterized by electrochemical
quartz crystal microbalance and complex impedance analysis, surface enhanced Raman spectroscopy and cyclic voltammetry. The
self-assembled electrode was used for the simultaneous electrochemical detection of epinephrine (EP) and uric acid (UA) in
phosphate buffer of pH 7.7. The simultaneous oxidation of EP and UA was performed by cyclic voltammetry (CV) and differential
pulse voltammetry (DPV), and the signals for each method were well separated with a potential difference of over 330 mV and
without interference by each other. The detection limit of EP is 5.4 × 10−8 mol L−1 by CV and 5.3 × 10−8 mol L−1 by DPV and that of UA is 8.4 × 10−8 mol L−1 by CV and 4.2 × 10−8 mol L−1 by DPV. The DMSA self-assembled electrode can be applied to the simultaneous determination of EP and UA. 相似文献
12.
An “off–on” rhodamine-based fluorescence probe for the selective signaling of Cr(III) has been designed by exploiting the
guest-induced structure transform mechanism. This system shows a sharp Cr(III)-selective fluorescence enhancement response
in 100% aqueous system under physiological pH value and possesses high selectivity against the background of environmentally
and biologically relevant metal ions including Cr(VI), Al(III), Fe(III), Cd(II), Co(II), Cu(II), Ni(II), Zn(II), Mg(II), Ba(II),
Pb(II), Na(I), and K(I). Under optimum conditions, the fluorescence intensity enhancement of this system is linearly proportional
to Cr(III) concentration from 5.0 × 10−8 to 7.0 × 10−6 mol L−1 with a detection limit of 1.6 × 10−8 mol L−1. 相似文献
13.
A compact miniaturized continuous flow system for the determination of urea content in milk 总被引:1,自引:0,他引:1
Willian Toito Suarez Osmundo Dantas Pessoa-Neto Vagner Bezerra dos Santos Ana Rita de Araujo Nogueira Ronaldo Censi Faria Orlando Fatibello-Filho Mar Puyol Julián Alonso 《Analytical and bioanalytical chemistry》2010,398(3):1525-1533
A multicommutation-based flow system with photometric detection was developed, employing an analytical microsystem constructed
with low temperature co-fired ceramics (LTCC) technology, a solid-phase reactor containing particles of Canavalia ensiformis DC (urease source) immobilized with glutaraldehyde, and a mini-photometer coupled directly to the microsystem which monolithically
integrates a continuous flow cell. The determination of urea in milk was based on the hydrolysis of urea in the solid-phase
reactor and the ammonium ions produced were monitored using the Berthelot reaction. The analytical curve was linear in the
urea concentration range from 1.0 × 10−4 to 5.0 × 10−3 mol L−1 with a limit of detection of 8.0 × 10−6 mol L−1. The relative standard deviation (RSD) for a 2.0 × 10−3 mol L−1 urea solution was lower than 0.4% (n = 10) and the sample throughput was 13 h−1. To check the reproducibility of the flow system, calibration curves were obtained with freshly prepared solutions on different
days and the RSD obtained was 4.7% (n = 6). Accuracy was assessed by comparing the results of the proposed method with those from the official procedure and the
data are in close agreement, at a 95% confidence level. 相似文献
14.
The electrode characteristics and selectivities of PVC-based thiocyanate selective polymeric membrane electrode (PME) incorporating
the newly synthesized zinc complex of 6,7:14,15-Bzo2-10,11-(4-methylbenzene)-[15]-6,8,12,14-tetraene-9,12-N2-1,5-O2 (I
1
) and zinc complex of 6,7:14,15-Bzo2-10,11-(4-methylbenzene)-[15]-6,14-diene-9,12-dimethylacrylate-9,12-N2-1,5-O2 (I
2
) are reported here. The best response was observed with the membrane having a composition of I2:PVC:o-NPOE:HTAB in the ratio of 6:33:59:2 (w/w; milligram). This electrode exhibited Nernstian slope for thiocyanate ions over working concentration range of 4.4 × 10−7 to 1.0 × 10−2 mol L−1 with detection limit of 2.2 × 10−7 mol L−1. The performance of this electrode was compared with coated graphite electrode (CGE), which showed better response characteristics
w.r.t Nernstian slope 59.0 ± 0.2 mV decade−1 activity, wide concentration range of 8.9 × 10−8 to 1.0 × 10−2 mol L−1 and detection limit of 6.7 × 10−8 mol L−1. The response time for CGE and PME was found to be 8 and 10 s, respectively. The proposed electrode (CGE) was successfully
applied to direct determination of thiocyanate in biological and environmental samples and also as indicator electrode in
potentiometric titration of SCN− ion. 相似文献
15.
The fabrication and electrochemical characteristics of a penicillamine (PCA) self-assembled monolayer modified gold electrode
were investigated. The electrode can enhance the electrochemical response of uric acid (UA), and the electrochemical reaction
of UA on the PCA electrode has been studied by cyclic voltammetry and differential pulse voltammetry. Some electrochemical
parameters, such as diffusion coefficient, standard rate constant, electron transfer coefficient and proton transfer number
have been determined for the electrochemical behavior on the PCA self-assembled monolayer electrode. The electrode reaction
of UA is an irreversible process, which is controlled by the diffusion of UA with two electrons and two protons transfer at
the PCA/Au electrode. In phosphate buffer (pH 5.0), the peak current is proportional to the concentration of UA in the range
of 6.0 × 10−5–7.0 × 10−4 mol L−1 and 2.0 × 10−5–7.0 × 10−4 mol L−1 for the cyclic voltammetry and differential pulse voltammetry methods with the detection limits of 5.0 × 10−6 and 3.0 × 10−6 mol L−1, respectively. The method can be applied to determine UA concentration in real samples. 相似文献
16.
Qiong He Tian Gan Dongyun Zheng ShengShui Hu 《Journal of Solid State Electrochemistry》2010,14(6):1057-1064
Simple and sensitive electrochemical method for the determination of nitrite, based on a nano-alumina-modified glassy carbon
electrode (GCE), is described. Nitrite yields a well-defined oxidation peak whose potential is 0.74 V at the nano-alumina-coated
GCE in 0.1 mol L−1 phosphate buffer (pH 5.0). Compared with bare GCE, the nano-alumina-modified GCE has evident catalytic effect towards the
oxidation of nitrite, and its peak current can be significantly enhanced. Some of the experimental parameters were optimized
for the determination of nitrite. The oxidation peak current was proportional to nitrite concentration in the range of 5.0 × 10−8–1.1 × 10−3 mol L−1, and a detection limit of 1.0 × 10−8 mol L−1 was obtained. This method has been successfully used to the determination of nitrite in sausage sample. Furthermore, results
obtained by the method have been compared with spectrophotometric method. 相似文献
17.
A 3-amino-5-mercapto-1,2,4-triazole (TA) self-assembled monolayer-modified gold electrode (TA SAM/Au) is characterized by
X-ray photoelectron spectroscopy, A.C. impedance, cyclic voltammetry, chronoamperometry and chronocoulometry. The TA SAM/Au
exhibited good promotion of the electrochemical oxidation of dopamine. Some electrochemical parameters of dopamine such as
electron transfer number, exchange current density, standard heterogeneous rate constant, diffusion coefficient, etc., were
measured by different electrochemical methods. The peak currents of dopamine were linearly dependent on its concentration
in the range of 1.5 × 10−6–1.0 × 10−4 mol L−1, with a detection limit of 5.0 × 10−7 mol L−1. The oxidative peak potentials of dopamine and ascorbic acid were well separated at about 190 ± 10 mV in pH 2.0 BR buffers
at TA SAM/Au, the oxidation peak current increases approximately linearly with increasing concentration of both dopamine and
ascorbic acid in the concentration range of 9.98 × 10−6–4.54 × 10−4 mol L−1. It can be used for simultaneous determination of dopamine and ascorbic acid. 相似文献
18.
Mohamed S. Ibrahim Mohamed S. El-Maazawi Khaled M. Al-Magboul Moustafa M. Kamal 《Mikrochimica acta》2001,137(3-4):215-220
A sensitive method for the determination of amitraz pesticide at nanomolar level by adsorptive stripping voltammetry at a
hanging mercury drop electrode is described. The cyclic voltammograms demonstrate the adsorption of this compound on the mercury
electrode. A systematic study of the various experimental parameters, that affect the stripping response, was carried out
by differential pulse voltammetry. Using an accumulation potential of −0.50 V, and 30 s accumulation time, the limit of detection
was found to be 2.3 × 10−9 mol L−1 and the relative standard deviations (n = 5) was 2.2% at concentration level of 5.0 × 10−8 mol L−1 of amitraz. The influence of diverse ions and some other pesticides was investigated. Finally, the method was applied to
the determination of amitraz in spiked soil and water. The relative standard deviation is 4.5% for 5 determinations of amitraz
in water and 3.2% for 5 determinations in soil.
Received December 6, 2000. Revision March 1, 2001. 相似文献
19.
Ying Xu Fei Wang Le Wang Fangyuan Zhao Baocheng Yang Baoxian Ye 《Journal of Solid State Electrochemistry》2012,16(4):1473-1480
A novel voltammetric sensor, based on single-walled carbon nanotubes (SWNT) dispersed in Nafion and modified glassy carbon
electrode (GCE), was fabricated and used to determine the trace amounts of dihydromyricetin (DMY). The electrochemical behavior
of DMY at this sensor was investigated in 0.1 mol L−1 sulfuric acid solutions + 0.1 mol L−1 NaCl by cyclic voltammetry and squarewave voltammetry. Compared with bare GCE, the electrode presented an excellent response
of DMY through an adsorption-controlled quasi-reversible process. Under the optimum conditions, the response peak currents
were linear relationship with the DMY concentrations in the range of 1.0 × 10−7–1.0 × 10−5 mol L−1 with a detection limit of 9 × 10−8 mol L−1. Based on this voltammetric sensor, a simple and sensitive electroanalytical method for DMY was proposed and applied to quantitative
determination of DMY in Ampelopsis grossedentata samples. In addition, the oxidation mechanism was proposed and discussed, which could be a reference for the pharmacological
action of DMY in clinical study. 相似文献
20.
Lina Zou Yamin Li Wenjie Zhao Shusheng Zhang Baoxian Ye 《Journal of Solid State Electrochemistry》2012,16(2):505-511
In the present work, a new voltammetric sensor, Langmuir–Blodgett (LB) film of tetraoxocalix[2]arene[2]triazine (TOCT) modified
glassy carbon electrode (LBTOCT-GCE), for trace analysis of copper ion in water samples, was prepared. The morphology of LBTOCT-GCE was characterized by cyclic voltammetric method, electrochemical impedance spectroscopy, and atomic force microscope.
The recognizing mechanism of LBTOCT-GCE for copper ion in aqueous solution was discussed. Under the optimum experimental conditions, using square wave stripping
voltammetry and accumulation time of 300 s, the peak currents were linear relationship with Cu2+ concentrations in the range of 2 × 10−9 to 1 × 10−6 mol L−1, with detection limit of 1 × 10−10 mol L−1. By this method, real samples (lake water, drinking water, and city wastewater) were analyzed with satisfactory results.
In addition, the fabricated electrode exhibited a distinct advantage of simple preparation, non-toxicity, good reproducibility,
and stability. 相似文献