首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This research addresses the variations in the ultrasonic backscatter from specimens consisting of a suspension of approximately aligned cylindrical scatterers in a fluid medium as a function of the angle of propagation in the sample. Predictions of the angular dependence of backscatter based on the time-domain Born approximation described by Rose and Richardson [J. H. Rose and J. M. Richardson, J. Nondestr. Eval. 3, 45-53 (1982)] were compared with experimental measurements of the backscatter from both tissue-mimicking phantoms consisting of graphite fibers suspended in gelatin and from canine myocardial tissue. The angular dependence of the backscatter was predicted and measured to be maximum for propagation perpendicular to the cylinder axes and minimum for propagation parallel to the axes. Maximum to minimum (i.e., perpendicular to parallel) changes in the integrated backscatter were predicted to be between 5 and 10 dB in the phantom. The corresponding quantity measured in both the phantom and in canine myocardial tissue was approximately 6 dB.  相似文献   

2.
Results of experiments performed in several laboratories indicate that contracting myocardium exhibits a cyclic variation of the magnitude of ultrasonic backscatter, with maxima occurring at end-diastole and minima at end-systole. The mechanisms responsible for this variation are not well understood. The purpose of the present study was to determine whether the frequency dependence of backscatter exhibits systematic variation throughout the cardiac cycle, analysis of which may facilitate improved understanding of biologic factors responsible for the cyclic variation of the magnitude of backscatter. In this study, the myocardial backscatter coefficient, as a function of frequency, was measured throughout the cardiac cycle in nine open-chest dogs. The frequency dependence of the backscatter coefficient was computed from a least-squares linear fit to log backscatter coefficient versus log frequency data. A cyclic variation of frequency dependence of backscatter was found with maximum near end-diastole (f2.6 +/- 0.1) and minimum near end-systole (f2.2 +/- 0.1), a significant variation (p less than 0.01). These results suggest that mechanisms responsible for the cyclic variation of backscatter may include changes in the effective size of the dominant scatterers throughout the cardiac cycle. An alternative explanation for the observed variation is an increase in the myocardial attenuation coefficient during systole followed by a decrease in diastole.  相似文献   

3.
The anisotropy of frequency-dependent backscatter coefficient, attenuation, and speed of sound is assessed in fresh rat skeletal muscle within 5 h post-mortem. Excised rat semimembranosus and soleus muscles are measured in 37 degrees C Tyrode solution, with the muscle fibers at 90 degrees and 45 degrees orientations to the incident sound beam. Reflected and through transmission signals from either a 6- or 10-MHz focused transducer give frequency dependent information in the 4-14 MHz range. The attenuation coefficient in each muscle is consistently a factor of 2.0 +/- 0.4 lower for propagation perpendicular to the fibers than at 45 degrees, whereas speed of sound shows a much milder anisotropy, and is slightly faster for the 90 degrees orientation. The largest anisotropy is seen in the backscatter coefficient, most notably in the semimembranosus where the magnitude at 90 degrees is over an order of magnitude greater than at 45 degrees, with the frequency dependence in both cases giving a power law between 1.5 and 2.0.  相似文献   

4.
Ultrasound tissue characterization with measurement of backscatter has been employed in numerous experimental and clinical studies of cardiac pathology, yet the cellular components responsible for scattering from cardiac tissues have not been unequivocally identified. This laboratory has proposed a mathematical model for myocardial backscatter that postulates the fibrous extracellular matrix (ECM) as a significant determinant of backscatter. To demonstrate the importance of ECM, this group sought to determine whether measurements of backscatter from the isolated ECM could reproduce the known directional dependence, or anisotropy of backscatter, from intact cardiac tissues in vitro. Segments of left ventricular free wall from ten formalin fixed porcine hearts were insonified at 50 MHz, traversing the heart wall from endo- to epicardium to measure the anisotropy of myocardial backscatter, defined as the difference between peak (perpendicular to fibers) and trough (parallel to fibers) backscatter amplitude. The tissue segments were then treated with 10% NaOH to dissolve all of the cellular components, leaving only the intact ECM. Scanning electron micrographs (SEM) were obtained of tissue sections to reveal complete digestion of the cellular elements. The dimensions of the residual voids resulting from cell digestion were approximately the diameter of the intact myocytes (10-30 microm). These samples were reinsonified after seven days of treatment to compare the anisotropy of integrated backscatter. The magnitude of anisotropy of backscatter changed from 15.4 +/- 0.8 to 12.6 +/- 1.1dB for intact as compared with digested specimens. Because digestion of the myocardium leaves only extracellular sources of ultrasonic scattering, and because the isolated ECM exhibits similar ultrasonic anisotropy as does the intact myocardium, it is concluded that there is a direct association between the ECM and the anisotropy of backscatter within intact tissue. Thus, it is suggested that ultrasonic tissue characterization represents a potentially clinically applicable method for delineating the structure and function of the ECM.  相似文献   

5.
It has been reported previously that acute and mature myocardial infarction in dogs can be differentiated in vitro and in vivo by ultrasonic tissue characterization based on measurement of the frequency dependence of ultrasonic backscatter. To characterize human infarction with an index of the frequency dependence of backscatter that could be obtained in patients, cylindrical biopsy specimens from 7 normal regions and 12 regions of infarction of 6 fixed, explanted human hearts in 2-deg steps around their entire circumference with a 5-MHz broadband transducer were insonified. One to six consecutive transmural levels were studied for each specimen. The dependence of apparent (uncompensated for attenuation or beam width) backscatter, /B(f)/2, on frequency (f) was computed from spectral analyses of radio-frequency data as /B(f)/2 = afn, where from theoretical considerations the magnitude of n decreases as scatterer size increases. Apparent integrated backscatter was computed as the average of /B(f)/2 from 3 to 7 MHz. The average value for n for normal tissue (0.9 +/- 0.1) exceeded that for tissue from regions of infarction (0.6 +/- 0.1; p less than 0.05). Infarct manifested a significant decrease of n from epicardial to endocardial levels (epi----mid----endo: 0.9----0.7----0.2; p less than 0.05) whereas normal tissue manifested similar values for n at each transmural level (0.8----1.1----0.9; p = NS). Average integrated backscatter across all transmural levels for infarct was significantly greater than for normal tissue (-48.3 +/- 0.5 vs -53.4 +/- 0.4 dB, infarct versus normal; p less than 0.05). The presence of fibrosis was associated with smaller values of n and greater integrated backscatter.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
This study was designed to measure the ultrasonic attenuation within phantoms and tissue samples over a broad bandwidth and at many angles of incidence with respect to intrinsic orientations in order to elucidate both the frequency and angular dependence of the attenuation coefficient. Significant angular dependence, or anisotropy, of the attenuation was observed in canine myocardium (maximum to minimum ratio: 2.2 to 1) and a tissue mimicking phantom of oriented graphite fibers in gelatin (max to min: 2 to 1). In control studies, insignificant anisotropy was observed in the attenuation in canine liver samples and phantoms with graphite powder suspended in gelatin. Comparisons of the magnitude of variations of the oriented-fiber phantom to that predicted by a viscous relative motion model are presented.  相似文献   

7.
A bistatic ultrasound imaging system is demonstrated that uses two 32-element linear phased array transducers oriented at an angle of 40 degrees to one another. The system simultaneously acquires and displays in real time one conventional backscatter image and one "angular scatter" image formed using side-scattered echoes from the same B-mode sector region. Experiments are presented that show differences in the magnitudes of backscatter and angular scatter signals acquired from three nylon monofilaments with diameters less than one wavelength and from soft tissue structures in vivo. The relative magnitudes of angular scatter signals from the monofilaments are qualitatively consistent with a theoretical analysis of acoustic scattering from elastic cylinders. Larger tissue features are more clearly defined in angular scatter images. This result is attributed to the orientation of specularly reflecting surfaces and the expected influence of scattering angle on the system's sensitivity to different scatterer spacings.  相似文献   

8.
The goal of this work was to determine whether the frequency dependence of apparent backscatter coefficient (not corrected for attenuation within the myocardium) could differentiate completed, remote infarction from acute myocardial injury in vivo. Myocardial infarcts were produced in six dogs by coronary artery occlusion. One to 12 months later, acute ischemic injury was induced in each dog by ligation of a coronary artery that supplied a region of myocardium adjacent to the established infarct. Infarct, ischemic, and normal regions were interrogated with a 5-MHz, circular, 0.5-in. diam, broadband, focused, piezoelectric transducer mounted in a water-filled stand-off device placed against the exposed, beating heart. Apparent backscatter coefficients were measured over the range of frequencies from 3-7 MHz. The frequency dependence was obtained from the slope of log apparent backscatter coefficient versus log frequency. No significant difference in frequency dependence was found between normal and acutely ischemic myocardium for periods of up to 2 h of ischemia. In contrast, frequency dependence in regions of remote infarct (1.8 +/- 0.1, mean +/- standard error) was significantly lower than that in acutely ischemic or nonischemic regions (2.3 +/- 0.1) (p less than 0.01). These results suggest that remote myocardial infarction can be differentiated from acutely injured but still potentially salvageable myocardium in vivo on the basis of the frequency dependence of backscatter.  相似文献   

9.
The anisotropy of the angular distribution of collagen fibrils in a sheep tendon was investigated by 1H double-quantum (DQ) filtered NMR signals. Double-quantum build-up curves generated by the five-pulse sequence were measured for different angles between the direction of the static magnetic field and the axis of the tendon plug. Proton residual dipolar couplings determined from the DQ build-up curves in the initial excitation/reconversion time regime which mainly represent the bound water are interpreted in terms of a model of spin-1/2 pairs with their internuclear axes oriented on average along the fibril direction in the presence of proton exchange. The angular distribution of collagen fibrils around the symmetry axis of the tendon measured by the anisotropy of the residual dipolar couplings was described by a Gaussian function with a standard deviation of 12 degrees +/-1 degrees and with the center of the distribution at 4 degrees +/-1 degrees. The existence of this distribution is directly reflected in the finite value of the residual dipolar couplings at the magic angle, the value of the angular contrast, and the oscillatory behavior of the DQ build-up curves. The 1H residual dipolar couplings were also measured from the doublets recorded by the DQ-filtered signals. From the angular dependence of the normalized splitting the angular distribution of the collagen fibrils was evaluated using a Gaussian function with a standard deviation of 19 degrees +/-1 degrees and with the center of distribution at 2 degrees +/-1 degrees. The advantages and disadvantages of these approaches are discussed.  相似文献   

10.
Recently, endolaryngeal sonography at frequencies ranging from 10 to 30 MHz has been found to be useful in diagnosing diseases of the vocal folds (VFs). However, image resolution can be further improved by ultrasound at higher frequencies, necessitating the measurement of high-frequency acoustic properties of VF tissue. The ultrasonic parameters of integrated backscatter, sound velocity, and frequency-dependent attenuation coefficient were measured in both the lamina propria (LP) and vocalis muscle (VM) of human VFs using a 47 MHz high-frequency ultrasonic transducer. The integrated backscatter was -173.44+/-6.14 (mean+/-s.d.) and -195.13+/-3.58 dB in the LP and VM, respectively, the sound velocity was 1667.68+/-44.9 and 1595.07+/-39.33 ms, and the attenuation coefficient at 47 MHz was 8.28+/-1.72 and 7.17+/-1.30 dBmm. The difference between these ultrasonic parameters may be attributed to variations in the structure and fiber concentrations in VF tissue. These results could serve as a useful clinical reference for the further development of high-frequency ultrasound devices for endolarynx sonography applications.  相似文献   

11.
The objective of this study was to measure the backscatter coefficient of formalin-fixed myocardial tissue as a function of angle of insonification relative to the myocardial fiber direction. Backscatter measurements were performed on eight cylindrical formalin-fixed lamb myocardial specimens and compensated for attenuation and diffraction effects to determine the backscatter coefficient. The backscatter coefficient at 5 MHz was found to be maximum for insonification perpendicular to the predominant myofiber orientation and minimum for parallel insonification, with values of (17+/-14) and (1.2+/-0.7) x 10(-4) cm(-1) sr(-1) (mean+/-standard deviation), respectively.  相似文献   

12.
Attenuation of ultrasound in post rigor bovine skeletal muscle   总被引:4,自引:0,他引:4  
A pulse transmission method for measuring the attenuation of 1-7 MHz ultrasound in bovine skeletal muscle is described. Measurements of the attenuation coefficient at -20, 0, 20 and 40 degrees C conformed to the relation alpha = Afn, where A and n are temperature-dependent coefficients and f is the frequency. alpha/f varied slowly with frequency, and at 4 MHz and 20 degrees C mean values were 1.3 dB cm-1 MHz-1 along the fibres and 0.55 dB cm-1 MHz-1 across the fibres. These data are lower than most previous measurements of skeletal muscle, but comparable with recent measurements of canine heart muscle.  相似文献   

13.
景洪  宁辉  陈鹏  刘英君  童清波 《强激光与粒子束》2018,30(5):053003-1-053003-5
在进行高功率微波(HPM)空中辐射场测量时,由于来波信号极化角度难以确定和受空中平台姿态影响等因素,普通线极化接收天线难以确保极化匹配,天线的极化失配会进一步降低辐射场参数测量的精确性。为了降低极化失配影响,在梯形微带圆极化单元天线分析设计的基础上,采用四阵元依次旋转90°和依次移相馈电的方式组建了一种低轴比微带圆极化阵列天线,该天线采用功分器和移相器作为馈电网络,天线在9.7 GHz实测增益约为9.4 dB,1 dB波束宽度约17.4°,轴比约0.4 dB。应用该圆极化天线可将极化失配引入的不确定度降低到0.2 dB以下,可满足高功率微波空中辐射场的精确测量需求。  相似文献   

14.
Seafloor classification using acoustic remote sensing techniques is an attractive approach due to its high-coverage capabilities and limited costs. The multi-beam echo-sounder (MBES) system provides high-resolution bathymetry and backscatter information with 100% coverage. In this paper, we present a seafloor classification method that employs the MBES backscatter data. The method uses the averaged backscatter data per beam. It, therefore, is independent on the quality of the MBES calibration. Also, its performance is insensitive to seafloor type variation along the MBES swathe and corrections for the angular dependence of the backscatter are not needed. The method accounts for the ping-to-ping variability of the backscatter intensity. It estimates both the number of seafloor types present in the survey area and the probability density function for the backscatter strength at a certain angle for each of the seafloor types. Application of the method to MBES backscatter data acquired in a well-known test area in the North Sea shows very good agreement with available ground truth. The method’s discriminatory performance for this area is demonstrated to be comparable to that of taking samples of the sediment. All seafloor types known to be present in the area are resolved for. Application of the method to the Stanton bank data set shows clearly separable areas that differ in seafloor composition.  相似文献   

15.
A three-dimensional biomechanical model of tissue deformation was developed to simulate dynamic vocal fold abduction and adduction. The model was made of 1721 nearly incompressible finite elements. The cricoarytenoid joint was modeled as a rocking-sliding motion, similar to two concentric cylinders. The vocal ligament and the thyroarytenoid muscle's fiber characteristics were implemented as a fiber-gel composite made of an isotropic ground substance imbedded with fibers. These fibers had contractile and/or passive nonlinear stress-strain characteristics. The verification of the model was made by comparing the range and speed of motion to published vocal fold kinematic data. The model simulated abduction to a maximum glottal angle of about 31 degrees. Using the posterior-cricoarytenoid muscle, the model produced an angular abduction speed of 405 degrees per second. The system mechanics seemed to favor abduction over adduction in both peak speed and response time, even when all intrinsic muscle properties were kept identical. The model also verified the notion that the vocalis and muscularis portions of the thyroarytenoid muscle play significantly different roles in posturing, with the muscularis portion having the larger effect on arytenoid movement. Other insights into the mechanisms of abduction/adduction were given.  相似文献   

16.
We proposed and fabricated an N:N optical coupler using an integrated waveguide mirror. Optical circuits can be miniaturized with small bending by reflecting mirrors. The parabolic curve was applied to the mirror shape because it was necessary to collimate the reflected beam so as to distribute the input light to the output waveguides. We fabricated the 8:8 optical coupler using silica waveguide. The chip size was about 7mm x 15mm. The excess loss of the device was about 8 dB larger than simulation results calculated using beam propagation method. The dependence on the wavelength and polarization was about 0.4 and 0.15 dB, respectively. The excess loss was mainly attributed to the mirror tilt and will be reduced by optimizing the etching conditions to decrease the mirror tilt angle.  相似文献   

17.
Cerenkov radiation is generated as an unwanted background when optical fibers carrying signals pass through radiation fields. The angular dependence of the intensity of ? Cerenkov radiation transmitted in silica-core fibers was measured using 6 and 12 MeV electron beams from a Varian Clinic accelerator. These confirmed theoretical predictions that the angular variation of ? Cerenkov radiation transmitted along optical fibers depends only on the refractive index difference Dn between the core and the cladding, and that the peak intensity is proportional to the cube of the fiber core radius.  相似文献   

18.
This paper studies the influence of parameter estimation on integrated backscatter using a computer model. The study is specifically aimed at applications to the heart muscle; however, the validity of the conclusions drawn from this work should be confirmed by in vivo tests.  相似文献   

19.
The purpose of this study was to investigate myocardial fiber pathway distribution in order to provide supplemental information on myocardial fiber architecture and cardiac mechanics. Diffusion tensor imaging (DTI) with medium diffusion resolution (15 directions) was performed on normal canine heart samples (N=6) fixed in formalin. With the use of diffusion tensor fiber tracking, left ventricle (LV) myocardial fiber pathways and helix angles were computed pixel by pixel at short-axis slices from base to apex. Distribution of DTI-tracked fiber pathway length and number was analyzed quantitatively as a function of fiber helix angle in step of 9 degrees . The long fiber pathways were found to have small helix angles. They are mostly distributed in the middle myocardium and run circumferentially. Fiber pathways tracked at the middle and upper LV are generally longer than those near the apex. Majority of fiber pathways have small helix angles between -20 degrees and 20 degrees , dominating the fiber architecture in myocardium. Likely, such myocardial fiber pathway measurement by DTI may reflect the spatial connectiveness or connectivity of elastic myofiber bundles along their preferential pathway of electromechanical activation. The dominance of the long and circumferentially running fiber pathways found in the study may explain the circumferential predominance in left ventricular contraction.  相似文献   

20.
Hysteresis loops were measured for varying angles of the applied field at different temperatures in oriented sintered magnets of compositions Fe75Pr17B8 and Fe53Pr17B30. While at elevated temperatures the coercive field increases monotonically with the angle of the applied field, a minimum in the angular dependence is found below room temperature. The temperature dependence of coercivity for the field applied parallel and with an angle of 45° to the alignment direction is well described by a nucleation model in the whole temperature range. The results are compared to Fe---Nd---B magnets, showing that the occurrence of a minimum in the angular dependence is related to the ratio of the experimental to the theoretical coercive fields.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号