首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Slurry-packed microcapillary column liquid chromatography with conventional infrared detection is described for the group-type analysis of gasolines. The results indicate that the three eluted groups, saturates, olefins and aromatics, from the microcapillary column are easily detected by conventional microcomputerized infrared spectrometer coupled with a Teflon flow-cell with a good signal-to-noise ratio. This study shows the feasibility of microcapillary column liquid chromatography combined with a low-cost, conventional infrared spectrometer as a routine tool which allows the analyst to use an LC-IR system effectively and economically.  相似文献   

2.
Ionic liquids (ILs), a class of unique substances composed purely by cation and anions, are renowned for their fascinating physical and chemical properties, such as negligible volatility, high dissolution power, high thermal stability, tunable structure and miscibility. They are enjoying ever-growing applications in a great diversity of disciplines.  相似文献   

3.
Summary Reversed-phase systems using octyl modified silica as such and as a support for dynamically coated ion-exchangers, were investigated for their ability to separate pentapeptides. Normal reversed-phase adsorption with C-8 bonded silica in combination with citrate bufferpropanol-1 mixtures were found useful for the separation of a number of pentapeptides. The separation of pentapeptides differing widely in retention can be speeded up by applying an organic modifier and/or sodium citrate gradient. A solvent generated cation-exchange system with sodium dodecylsulfate as surfactant showed a high selectivity for the pentapeptides under investigation and is better for analytical purposes than the normal reversed-phase adsorption systems investigated. With respect to the detection of pentapeptides with fluorescamine, the use of dry pyridine as a basic buffer and as diluent for the fluorescamine was also investigated. Compared to the commonly used diluent acetone, pyridine is better when using acidic eluents of moderate buffer strength. At pH>6 no significant differences in sensitivity between acetone and pyridine could be noticed.  相似文献   

4.
Summary A new, rapid, sensitive, and specific method for the determination of methoxsalen in dosage forms using HPLC has been developed. methoxsalen is extracted in chloroform, evaporated on a water bath, and the residue is redissolved in ethanol. A standard solution of khellin (internal standard) in ethanol is added, and injected. A plot of peak height ratio (methoxsalen/internal standard) vs. concentration of methoxsalen gave a straight line (r=0.998). The column used was a stainless steel, 3.8 mm×30 cm, and the mobile phase was methanol: water (6040) at a flow rate of 2 cm3/min. Retention times for methoxsalen and khellin were 3.45 and 9.6 min, respectively. This method was found superior to the spectrophotometric assay in that no interference was encountered from structurally similar compounds or from coloring agents used in some commercial methoxsalen products.  相似文献   

5.
Polysiloxanes immobilized onto the surfaces of porous silica particles have proven to be good stationary phases for the separation of multiresidues of pesticides and their metabolic/degradation products by reversed-phase high-performance liquid chromatography (RP-HPLC). Similar materials have proven effective for pre-concentration and clean-up procedures using solid phase extraction. The present paper describes the preparation and some applications of several of these packing materials.  相似文献   

6.
建立了准确测定血清中尿酸含量的高效液相色谱方法,血清样品利用乙腈沉淀蛋白,过滤后直接进样测定。所采用的色谱柱为Inertsil ODS-SP(4.6mm i.d.×250 mm,5μm),柱温25℃,流动相体系为10 mmol/L乙酸铵(pH 4.5),流速为1.0 mL/min,紫外检测波长为280 nm。线性范围12.5~150μg/g,回收率为99.79%~100.5%。本文采用乙酸铵缓冲体系,对环境的污染小,同时也为建立液相色谱-质谱法测定尿酸奠定了良好的基础。  相似文献   

7.
Microemulsion electrokinetic chromatography (MEEKC) has been developed for fingerprint analysis of resina draconis, a substitute for sanguis draconis in the Chinese market. The microemulsion as the running buffer was made up of 3.3% (w/v) sodium dodecyl sulfate (SDS), 6.6% (w/v) n-butanol, 0.8% (w/v) n-octane, and 10 mmol/L sodium tetraborate buffer (pH 9.2), which was also used as the solvent for ultrasonic extraction of both water- and fat-soluble compounds in the traditional Chinese medicine samples. Four batches of resina draconis obtained from different pharmaceutical factories located in different geographic regions were used to establish the electrophoretic fingerprint. MEEKC was performed using a Beckman PACE/MDQ system equipped with a diode-array detector and with monitoring at 280 nm. The fingerprint of resina draconis comprised 27 common peaks within 100 min. The relative standard deviations of the relative migration time of these common peaks were less than 2.1%. Through repetitive injection of the sample solution six times in 24 h, all relative standard deviations of the migration time and peak area of loureirin A and loureirin B were less than 2.5 and 3.8%, which demonstrated that the method had good stability and reproducibility. The relative peak areas of these common peaks in the electropherograms of four batches of resina draconis were processed with two mathematical methods, the correlation coefficient and the interangle cosine, to valuate the similarity. The values of the similarity degree of all samples were more than 0.91, which showed resina draconis samples from different origins were consistent. On the other hand, high-performance liquid chromatography (HPLC) coupled with photodiode-array detection was also applied to establish the fingerprint of resina draconis. The samples were separated with a LiChrospher C18 column using acetonitrile (solvent A) and water containing 0.1% H3PO4 (solvent B) as the mobile phase in linear gradient elution mode at a flow rate of 0.6 mL/min and detection was at 280 nm. There were only 20 common peaks in the HPLC fingerprint, and the values of the similarity degree of all samples were also more than 0.91. Though the similarity results of fingerprint analysis seemed to be the same, MEEKC resulted in more common peaks and higher separation efficiency for a variety of polarities of the components than HPLC. So, MEEKC was more suitable for development of the fingerprint of resina draconis.  相似文献   

8.
A fast method using high-performance liquid chromatography based on two monolithic columns has been developed for the simultaneous determination of isoflavones extracted from soybeans and derived foods. The 12 main isoflavones were resolved in 10 min in two coupled monolithic columns working at 35 °C using a elution gradient of acidified water (0.1% acetic acid) and methanol (0.1% acetic acid) at a flow rate of 5 mL min−1. Retention time and relative area standard deviations were below 1% for all isoflavones. The method developed was successfully applied to several soy food samples and spiked samples. Total isoflavone concentration in sampled soy foods ranged from 34.28 mg L−1 to 4.29 mg g−1.  相似文献   

9.
High-performance liquid chromatographic method (HPLC) with evaporative light scattering detection (ELSD) coupled with microwave-assisted extraction (MAE) as an efficient sample preparation technique has been developed for fingerprint analysis of Dioscorea nipponica. The samples were separated with an Agilent C8 column using water (A) and acetonitrile (B) under gradient conditions (0-10 min, linear gradient 20-40% B; 10-12 min, linear gradient 40-42% B; 12-25 min, isocratic 42% B) as the mobile phase at a flow rate of 1 mL min−1 within 22 min. The ELSD conditions were optimized at nebulizer-gas flow rate 2.7 L min−1 and drift tube temperature 90 °C. Precision experiments showed relative standard deviation (R.S.D.) of peak area and retention time were better than 2.5%; inter-day and intra-day variabilities showed that R.S.D. was ranged from 0.78% to 4.74%. Limit of detection was less than 50 μg mL−1 and limit of quantification was less than 80 μg mL−1. Accuracy validation showed that average recovery was between 97.39% and 104.07%. The method was validated to achieve the satisfactory precision and recovery. Relative retention time and relative peak area were used to identify the common peaks for fingerprint analysis. There are nine common peaks in the fingerprint. The quality of seven batches of D. nipponica samples was evaluated to be qualified or unqualified by the parameters “difference” and “total difference” of common peaks. Furthermore, the contents of important medicinal compounds (dioscin, prodioscin and gracillin) in different batches of D. nipponica samples were determined simultaneously using the developed HPLC-ELSD method. The results indicated variation of the herb quality which might be related to different producing area, growing condition, climate, harvest time, drug processing and so on. The developed analytical procedure was proved to be a reliable and rapid method for the quality control of D. nipponica.  相似文献   

10.
Summary A rapid method is described for the quantitative determination of aromatic-type groups in gas oil petroleum fractions. The method involves separation by high-performance liquid chromatography followed by detection with a differential refractometer, whose response to aromatic-type groups is more predictable than an ultra violet absorbance detector. A primary standard is used for calibration, and the precision and accuracy of the method have been investigated and are discussed.  相似文献   

11.
By using ionic liquid as membrane liquid and tri-n-octylphosphine oxide (TOPO) as additive, hollow fiber supported liquid phase microextraction (HF-LPME) was developed for the determination of five sulfonamides in environmental water samples by high-performance liquid chromatography with ultraviolet detection The extraction solvent and the parameters affecting the extraction enrichment factor such as the type and amount of carrier, pH and volume ratio of donor phase and acceptor phase, extraction time, salt-out effect and matrix effect were optimized. Under the optimal extraction conditions (organic liquid membrane phase: [C8MIM][PF6] with 14% TOPO (w/v); donor phase: 4 mL, pH 4.5 KH2PO4 with 2 M Na2SO4; acceptor phase: 25 μL, pH 13 NaOH; extraction time: 8 h), low detection limits (0.1–0.4 μg/L, RSD ≤ 5%) and good linear range (1–2000 ng/mL, R2 ≥ 0.999) were obtained for all the analytes. The presence of humic acid (0–25 mg/L dissolved organic carbon) and bovine serum albumin (0–100 μg/mL) had no significant effect on the extraction efficiency. Good spike recoveries over the range of 82.2–103.2% were obtained when applying the proposed method on five real environmental water samples. These results indicated that this present method was very sensitive and reliable with good repeatabilities and excellent clean-up in water samples. The proposed method confirmed hollow fiber supported ionic liquid membrane based LPME to be robust to monitoring trace levels of sulfadiazine, sulfamerazine, sulfamethazine, sulfadimethoxine and sulfamethoxazole in aqueous samples.  相似文献   

12.
A simple cloud-point extraction method for the determination of meloxicam in human serum was developed. Meloxicam was extracted from serum sample after adding 1 mL of 3% (v/v) Triton X-114 aqueous solution in the presence of 1M HCl and 60 mg NaCl. The meloxicam, present in the surfactant-rich phase, was enriched again with acetonitrile. Tenoxicam was used as the external standard. The separation was achieved on a C18 analytical column with a mobile phase consisting of aqueous acetic acid (1%, v/v) and acetonitrile (54:46, v/v). UV detection was performed at 360 nm. The response was linear over the range 45–2000 ng mL−1 in human serum, and intra- and interday precisions of less than 15.0% were obtained. The relative error was within ±3.0%. The recoveries of meloxicam were larger than 92.0%. The method was compared with liquid–liquid extraction. The results showed that the new method has a considerable LOQ and higher recoveries but poorer precision than liquid–liquid extraction, which exhibited poor recoveries of less than 86.0%, precisions of less than 5.0% and relative errors of less than 7.0%. The method was used for the determination of meloxicam in healthy human volunteers.  相似文献   

13.
Two novel chiral stationary phases (CSPs) were prepared by bonding chiral imidazoliums on the surface of silica gel. The chiral imidazoles were derivatized from chiral amines, 1-phenylethylamine and 1-(1-naphthyl)ethylamine. The obtained CSPs were characterized by Fourier Transform Infrared (FT-IR) spectroscopy and elemental analysis (EA), demonstrating the bonding densities of CSP 1 and CSP 2 were 0.43 mmol g−1 and 0.40 mmol g−1, respectively. These two CSPs could be used to availably separate 8 pharmaceuticals, 7 mandelic acid/its derivatives, 2 1-phenylethylamine derivatives, 1 1,1′-bi-2-naphthol, and 1 camphorsulfonic acid in high-performance liquid chromatography (HPLC). It is found that CSP 1 could effectively enantioseparate most chiral analytes, especially the acidic components, while CSP 2 could enantiorecognize all chiral analytes, although a number of components did not achieve baseline separation. Additionally, the effects of mobile phase composition, mobile phase pH and salt content, chiral selector structures, and analyte structures on the enantiorecognitions of the two CSPs were investigated. It is found that high acetonitrile content in mobile phases was conducive to enantiorecognition. Mobile phase pH and salt content could alter the retention behaviors of different enantiomers of the same chiral compound, resulting in better enantioresolution. Moreover, both chiral selector structures and substituted groups of analytes played a significant role in the separation of chiral solutes.  相似文献   

14.
Summary An automatic liquid sampler for high-performance liquid chromatography is described.The sampler is based on a GC-injection system from Hewlett-Packard. The HPLC sampler has a unique cleaning system, excellent reproducibility and a plug-in compatibility for sample identification and computer control for Hewlett-Packard integrators and Laboratory Data Systems.  相似文献   

15.
In this work, a stable electrogenerated chemiluminescence (ECL) detector was developed. The detector was prepared by packing cation-exchanged resin particles in a glass tube, followed by inserting Pt wires (working electrode) in this tube and sealing. The leakage of Ru(bpy)32+ can be compensated by adding a small amount of Ru(bpy)32+ into solution phase. Coupled with high-performance liquid chromatography separation, the detector has been used for determination of itopride hydrochloride in human serum. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of itopride hydrochloride in the range of 1.0 × 10−8 g mL−1 to 1.0 × 10−6 g mL−1 and the detection limit was 3 × 10−9 g mL−1 (S/N = 3). The as-prepared ECL detector displayed good sensitivity and stability.  相似文献   

16.
正A new ionic liquid-based high-performance liquid chromatography stationary phase is reported.A derivative of N-methyl pyrrolidinium tetrafluoroborate was covalently immobilized on the surface of silica particles to prepare silica-based N-methyl pyrrolidinium tetrafluoroborate(SilprMP BF4)stationary phase.The obtained ionic liquid-modified silica was evaluated and confirmed by elemental analysis,infrared spectroscopy,and thermogravimetric analysis.A column was packed with the modified particles.The retention behavior of aromatic compounds,alkyl benzenes,and acidic and basic compounds on the SilprMP BF4 stationary phase was studied under reversed-phase liquid chromatography conditions.The effect of the eluent pH on the separation of the acidic and basic compounds was also studied.The new stationary phase involves multiple retention mechanisms,such as electrostatic,hydrophobic,ion-dipole,and anion-exchange interactions,which might lead to multipurpose separation media.  相似文献   

17.
Huang SD  Huang HI  Sung YH 《Talanta》2004,64(4):887-893
Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) for the determination of triazine is described. Carbowax/templated resin (CW/TPR, 50 μm), polydimethylsiloxane/divinylbenzene (PDMS/DVB, 60 μm), polydimethylsiloxane (PDMS, 100 μm), and polyacrylate (PA, 85 μm) fibers were evaluated for extraction of the triazines. CW/TPR and PDMS/DVB fibers were selected for further study. Several parameters of the extraction and desorption procedure were studied and optimized (such as types of fibers, desorption mode, desorption time, compositions of solvent for desorption, soaking periods and the flow rate during desorption period, extraction time, temperature, pH, and ionic strength of samples). Both CW/TPR and PDMS/DVB fibers are acceptable; a simple calibration-curve method based on simple aqueous standards can be used. The linearity of this method for analyzing standard solution has been investigated over the range 5-1000 ng mL−1 for both PDMS/DVB and CW/TPR fibers. All the correlation coefficients in the range 5-1000 ng mL−1 were better than 0.995 except Simazine and Atratone by CW/TPR fiber. The R.S.D.s range from 4.4% to 8.8 % (PDMS/DVB fiber) and from 2.4% to 7.2% (CW/TPR fiber). Method-detection limits (MDL) are in the range 1.2-2.6 and 2.8-3.4 ng mL−1 for the two fibers. These methods were applied to the determination of trazines in environmental water samples (lake water).  相似文献   

18.
A perhydro-26-membered hexaazamacrocycle-based silica (L1GlySil) stationary phase for high-performance liquid chromatography (HPLC) was prepared using 3-glycidoxypropyltrimethoxysilane as coupling reagent. The structure of new material was characterized by infrared spectroscopy, elemental analysis and thermogravimetric analysis. The chromatographic performance and retention mechanism of the new phase were evaluated in reversed-phase (RP) and normal-phase (NP) modes using different solute probes including aromatic compounds, organophosphorus pesticides, carbamate pesticides and phenols. The results showed that L1GlySil was a sort of multimode-bonded stationary phase with excellent chromatographic properties. The new phase could provide various action sites for different solutes, such as hydrophobic, hydrogen bonding, π–π, dipole–dipole interactions and acid–base equilibrium. The presence of phenyl rings, secondary amino groups and alkyl linkers in the resulting material made it suitable for the separation of above-mentioned analytes by multimode retention mechanisms.  相似文献   

19.
The recent development of fused-core technology in HPLC columns is enabling faster and highly efficient separations. This technology was evaluated for the development of an fast analysis method for the most relevant soy isoflavones. A step-by-step strategy was used to optimize temperature (25-50 °C), flow rate (1.2-2.7 mL/min), mobile phase composition and equilibration time (1-5 min). Optimized conditions provided a method for the separation of all isoflavones in less than 5.8 min and total analysis time (sample-to-sample) of 11.5 min. Evaluation of chromatographic performance revealed excellent reproducibility, resolution, selectivity, peak symmetry and low limits of detection and quantification levels. The use of a fused-core column allows highly efficient, sensitive, accurate and reproducible determination of isoflavones with an outstanding sample throughout and resolution. The developed method was validated with different soy samples with a total isoflavone concentration ranging from 1941.53 to 2460.84 μg g−1 with the predominant isoflavones being isoflavone glucosides and malonyl derivatives.  相似文献   

20.
Two covalently bonded cationic β-CD chiral stationary phases (CSPs) prepared by graft polymerization of 6A-(3-vinylimidazolium)-6-deoxyperphenylcarbamate-β-cyclodextrin chloride or 6A-(N,N-allylmethylammonium)-6-deoxyperphenylcarbamoyl-β-cyclodextrin chloride onto silica gel were successfully applied in high-performance liquid chromatography (HPLC). Their enantioseparation capability was examined with 12 racemic pharmaceuticals and 6 carboxylic acids. The results indicated that imidazolium-containing β-CD CSP afforded more favorable enantioseparations than that containing ammonium moiety under normal-phase HPLC. The cationic moiety on β-CD CSPs could form strong hydrogen bonding with analytes in normal-phase liquid chromatography (NPLC) to enhance the analytes’ retention and enantioseparations. In reversed-phase liquid chromatography (RPLC), the analytes exhibited their maximum retention when the pH of mobile phase was close to their pKa value. Inclusion complexation with CD cavity and columbic/ionic interactions with cationic substituent on the CD rim would afford accentuated retention and enantioseparations of the analytes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号