首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
A new method for the determination of nitrobenzene (NB) by differential pulse voltammetry (DPV) based on an adsorptive stripping technique was developed. Cyclic voltammetry (CV) was used in a comparative investigation into the electrochemical reduction of NB at a glassy carbon electrode (GCE). With this electrode, the sharp peak of NB appeared at −0.71 V (vs. Ag/AgCl). The experimental parameters were optimized. Studies on the effect of pH on the peak height and peak potential were carried out over the pH range ca. 9.0–11.5 with sodium carbonate/sodium hydrogen carbonate buffer solution. A solution of pH 9.9 was chosen as analytical medium. Cathodic peak currents were found to be linearly related to the concentration of NB over the range ca. 12.3–1.23 × 104 μg L−1 with relative standard deviations of ca. 3.26–6.75%. The detection limit of NB in water was 5.42 μg L−1. The interference of organic and inorganic species on the voltammetric response was also studied. The proposed method was applied to the determination of NB in wastewater samples with an average recovery of ca. 95.9–102.4%.  相似文献   

2.
 The primary method for pH is based on the measurement of the potential difference of an electrochemical cell containing a platinum hydrogen electrode and a silver/silver chloride reference electrode, often called a Harned cell. Assumptions must be made to relate the operation of this cell to the thermodynamic definition of pH. National metrology institutes use the primary method to assign pH values to a limited number of primary standards (PS). The required comparability of pH can be ensured only if the buffers used for the calibration of pH meter-electrode assemblies are traceable to these primary pH standards. To assess the degree of equivalence, comparisons of primary measurement procedures for pH were organized in co-operation with EUROMET. Typical results will be presented. In 1998, the Consultative Committee for Amount of Substance (CCQM) decided to include the field of pH in its working programme. The first key comparison for this quantity was recently carried out on two phosphate buffer solutions. Received: 14 June 2000 / Accepted: 22 August 2000  相似文献   

3.
In this paper, a new highly sensitive potentiometric pH electrode is proposed based on the solid-state PbO2 film electrodeposited on carbon ceramic electrode (CCE). Two different crystal structures of PbO2, α and β were examined and the similar results were obtained. Moreover, the experimental results obtained for the proposed pH sensor and a conventional glass pH electrode were in good agreement. The electromotive force (emf) signal between the pH-sensitive PbO2-coated CCE and SCE reference electrode was linear over the pH range of 1.5–12.5. Near-Nernstian slopes of −64.82 and −57.85 mV/pH unit were obtained for α- and β-PbO2 electrodes, respectively. The interferences of some mono-valence and multi-valence ions on potentiometric response of the sensor were studied. The proposed pH sensor displayed high ion selectivity with respect to K+, Na+, Ca2+, and Li+, with log values around −12 and has a working lifetime of about 30 days. Key parameters important for the pH sensor performance, including kind of PbO2 film, selectivity, response time, stability, and reproducibility, have been characterized. The proposed electrode showed a good efficiency for direct pH-metry after calibration and pH-metric titrations without calibration step. The response time was about 1 s in acidic medium and less than 30 s in alkaline solutions. The pH values of complex matrix samples such as fruit juices measured by the proposed sensor and a conventional glass pH electrode were in good agreement.  相似文献   

4.
An 1-(pyridylazo)-2-naphthol modified glassy carbon electrode has been investigated as sensor for the measurement of trace levels of Cd2+. Cd2+ is deposited on the surface of a PAN modified glassy carbon electrode at –1.10 V (vs. SCE) via forming Cd2+–PAN and subsequent reduction at the electrode. In the following step, Cd-PAN is oxidized, and voltammograms are recorded by scanning the potential in a positive direction. Calibration plots were found to be linear in the range 2 × 10–8 mol/L to 8 × 10–7 mol/L. The detection limit was 5 × 10–10 mol/L, and the coefficient of variation, determined on one single electrode at a concentration of 5 × 10–7 mol/L, was calculated to be 3.2% (n = 5). Using this new kind of modified electrode, trace levels of Cd(II) in water samples were determined; the average recovery was calculated to be 98.78%. Received: 17 August 2000 / Revised: 19 December 2000 / Accepted: 27 December 2000  相似文献   

5.
The values of the second dissociation constant, K 2, and related thermodynamic quantities of the ampholyte bis[(2-hydroxyethyl)amino]acetic acid (BICINE) have been determined at temperatures from 5 to 55 C. The pH values of six equimolal buffer solutions, and four buffer solutions having ionic strengths (I = 0.16 mol⋅kg−1) similar to those in blood plasma, have been evaluated at 12 temperatures from 5 to 55 C using the Bates–Guggenheim convention. The liquid junction potentials (E j ) between the buffer solutions of BICINE and saturated KCl solution of the calomel electrode at 25 and 37 C have been estimated by measurement with a flowing junction cell. These values of E j have been used to ascertain the operational pH values at 25 and 37 C. The pK 2 values at 25 and 37 C are 8.333 and 8.156, respectively. The thermodynamic quantities associated with the second acid dissociation have been calculated from the values of pK 2 as a function of temperature. The zwitterionic buffer BICINE was shown to be useful as a pH standard in the region close to that of blood serum.  相似文献   

6.
The construction, performance characteristics and applications of a polymeric membrance electrode for lead(II) ion are reported. The electrode was prepared by incorporating cryptand(222) as the neutral carrier into a plasticized poly(vinyl chloride) membrane. The influence of membrane composition, pH and concentration of internal reference solution were investigated. The electrode exhibits a potentiometric response for Pb2+ ion over the concentration range 10–1–10–5 M with a detection limit of 5 × 10–6 M Pb2+. It shows a relatively fast response time of about 30 s and can be used for about two months without any considerable divergence in potential. The proposed sensor revealed good selectivities for Pb2+ in the presence of several metal ions and could be used in the pH range of 2.5 to 7.5. It was used as an indicator electrode in the potentiometric titration of Pb2+ with EDTA. Received: 20 November 1998 / Revised: 26 March 1999 / Accepted: 31 March 1999  相似文献   

7.
A PVC membrane electrode based on a cadmium–salen (N,N′-bis-salicylidene-1,2ethylenediamine) complex as an anion carrier is described. The electrode has an anti-Hofmeister selectivity sequence with a preference for thiocyanate at pH 1.5–11.0. It has a linear response to thiocyanate from 1.0 × 10–6 to 1.0 × 10–1 mol L–1 with a slope of 59.1 ± 0.2 mV per decade, and a detection limit of 7 × 10–7 mol L–1. This electrode has high selectivity for thiocyanate relative to many common organic and inorganic anions. The proposed sensor has a fast response time of approximately 15 s. It was applied to the determination of thiocyanate in a milk sample. Received: 1 December 2000 / Revised: 19 April 2001 / Accepted: 30 April 2001  相似文献   

8.
The construction, performance characteristics and applications of a polymeric membrance electrode for lead(II) ion are reported. The electrode was prepared by incorporating cryptand(222) as the neutral carrier into a plasticized poly(vinyl chloride) membrane. The influence of membrane composition, pH and concentration of internal reference solution were investigated. The electrode exhibits a potentiometric response for Pb2+ ion over the concentration range 10–1–10–5 M with a detection limit of 5 × 10–6 M Pb2+. It shows a relatively fast response time of about 30 s and can be used for about two months without any considerable divergence in potential. The proposed sensor revealed good selectivities for Pb2+ in the presence of several metal ions and could be used in the pH range of 2.5 to 7.5. It was used as an indicator electrode in the potentiometric titration of Pb2+ with EDTA. Received: 20 November 1998 / Revised: 26 March 1999 / Accepted: 31 March 1999  相似文献   

9.
A very sensitive and selective catalytic adsorptive cathodic stripping procedure for trace measurements of cobalt is presented. The method is based on adsorptive accumulation of cobalt-CCA (calcon carboxylic acid) complex onto a hanging mercury drop electrode followed by reduction of the adsorbed species by voltammetric scan using differential pulse modulation. The reduction current is enhanced catalytically by nitrite. The effect of various parameters such as pH, concentration of CCA, concentration of nitrite, accumulation potential and accumulation time on the selectivity and sensitivity were studied. The optimum condition for the analysis of cobalt, include pH 5.2 (Acetate buffer), 2.1 μM clacon carboxylic acid, 0.032 M sodium nitrite and an accumulation potential of 0.05 V (versus Ag/AgCl). Under these optimum conditions and for an accumulation time of 60 s, the measured peak current at −0.480 V is proportional to the concentration of cobalt over the entire concentration range tested 0.003–2.0 ng ml−1 with a detection limit of 1 pg ml−1 for an accumulation time of 60 s and 2.0–10.0 ng ml−1 for an accumulation time of 40 s. The relative standard deviations for ten replicate measurement of 0.5 ng ml−1 of cobalt were 3.1%. The main advantage of this new system is the microtrace Co(II) determination by ASV. The method was applied to determination of cobalt in a water sample and some analytical grade salts with satisfactory results. Published in Elektrokhimiya in Russian, 2009, Vol. 45, No. 2, pp. 221–228. The article is published in the original.  相似文献   

10.
Dependence of the uncertainty of a pH measurement result on the quality of buffers (i.e. the uncertainty of their certified pH values) at different levels of instrumental uncertainty (pH-meter, etc.) was simulated using the Monte Carlo method and regression analysis. The contribution of the instrumental standard uncertainty (in the studied range from 0.1 to 1 mV) to the uncertainty of the pH measurement result is negligible, if the standard uncertainties of the pH buffers exceed 0.04 pH (e. g. for in-house buffers). It is shown how the choice of pH-meter and buffers should be correlated in order to meet the required uncertainty of a pH measurement result in a sample under analysis. The results of the simulation were compared with experimental data obtained from calibrations of a pH/ion-meter with a hydrogen working electrode (Radiometer PHM-240) and with a glass electrode (Metrohm 744). Buffers of different quality (National Institute for Standards and Technology standard reference materials, certified Radiometer buffers and Merck CertiPUR buffers) were used for the calibrations. The uncertainties of the experimental results are close to the predicted ones obtained by the simulation. Received: 16 June 2002 Accepted: 19 July 2002 Presented at the 14th International Conference of the Israel Society for Quality, 18–21 November 2002, Jerusalem, Israel Correspondence to I. Kuselman  相似文献   

11.
A ‘self-doped’ polyaniline modified microelectrode, prepared by cyclic potential sweep on a microdisk gold electrode from –0.2 to 0.85 V in 0.5 mol/L sulfuric acid containing aniline and o-aminobenzoic acid, has been developed. The copolymerized process and the resulting polymer characteristics were investigated in detail. This composite film indicated a good electrochemical activity in a wide pH range even in basic solution. Meanwhile, the redox couple exhibited an excellent electrocatalytic activity for the oxidation of ascorbic acid. The oxidation overpotential of ascorbic acid was decreased over 200 mV at this modified electrode compared with a bare gold one. Moreover, the effects of film thickness and pH on the catalytic efficiency were further studied. The dependence of catalytic currents on the concentration of ascorbic acid was linear in the range of 1.2 × 10–5∼ 2.4 × 10–3 mol/L with a correlation coefficient of 0.996. Also, the determination of ascorbic acid in actual samples was evaluated and the results are satisfactory. Received: 7 October 1997 / Revised: 3 February 1998 / Accepted: 7 February 1998  相似文献   

12.
For preparing a berberine-sensitive electrode, 5,10,15,20-tetrakis[2-(2,3,4,6-tetraacetyl-β-D-glucopyranosyl)-1-O-phenyl]porphyrin (T(o-glu)PPH2) was synthesized from the reaction of pyrrole with ortho-acetylglycosylated benzaldehyde by Lindsay’s method. The electrode based on T(o-glu)PPH2 with an optimized membrane composition exhibits Nernstian response to berberine in the concentration range 2.4 × 10–7–5.0 × 10–3 mol L–1, with a pH range from 3.9 to 10.2, and a fast response time of 30 s. The electrode shows fair selectivity towards berberine with respect to common co-existing species. T(o-glu)PPH2 shows better potentiometric response characteristics comparing to chloro[5,10,15,20-tetrakis[2-(2,3,4,6-tetraacetyl-β-D-glucopyranosyl)-1-O-phenyl]-porphinato]-manganese (MnT(o-glu)PPCl) and better selectivity towards berberine than tetraphenylporphyrin (TPPH2). The effect of the composition of the electrode membrane has been studied and the experimental conditions optimized. The contents of berberine in pharmaceutical tablets were determined by direct potentiometry and the results agreed with values obtained by the pharmacopoeia method. Received: 17 July 2000 / Revised: 18 September 2000 / Accepted: 23 October 2000  相似文献   

13.
It has not been long that metrology is well accepted as an important part in analytical chemistry since it helps the chemists to receive the best measurement and accurate results with traceability. The National Institute of Metrology Thailand (NIMT), which is a public agency under the supervision of the Ministry of Science and Technology, not only focuses on physical standards but also provides and maintains standards in chemical field. pH measurement is one of the most widely used in the laboratories including industries and medical area in Thailand. The chemical laboratory starts working on the project with the objective of disseminating an accurate result in routine pH measurement. In 2002, the laboratory provided a service in calibration of pH meter and organized the first local interlaboratory comparison program (NIMT–C-ILC-1: pH buffer) in pH measurement. There were three buffer solution samples in the range of acid, neutral, and base. A total of 44 laboratories participated in this program. The NIMT chemical laboratory also participated in the proficiency testing program that was conducted by PSB Corporation Testing Group in Singapore. In 2003, NIMT started research in preparation of secondary buffers by using highly accurate pH meters with glass electrode systems. The laboratory produced three secondary buffers, which were pH 4.01, 6.86, and 9.18 with uncertainty 0.020 pH at 25°C. The competence of the laboratory was shown by the measurement results of the pilot study (APMP.QM-P06), which was organized by the APMP electrochemical analysis working group (EAWG/TCQM) in 2005. The title of this study was “pH determination of two phosphate buffers by Harned cell method and glass electrode method”. NIMT aims to achieve for establishment of the primary method for pH measurement in the near future. Presented at -- “BERM-10” -- April 2006, Charleston, SC, USA  相似文献   

14.
The results obtained in potentiometric titrations of copper(II), mercury(II) and iron(III) with standard EDTA solutions are presented. The titration of copper(II) at pH values in the range from 8.11 to 10.99 (ammonia buffer) and the titration of mercury(II) and iron(III) at pH values from 3.59 to 5.65 (acetate buffer) were performed. The titration end-point (TEP) was detected with an indicator electrode made from natural crystalline pyrite as an electrochemical sensor. The results obtained in potentiometric titration with the pyrite electrode were compared with those obtained using a platinum electrode (Fe3+), a Cu ion selective electrode (Cu2+) and a Hg electrode (Hg2+). Accurate and reproducible results with good agreement were obtained, but higher potential changes at the TEP were obtained using the pyrite electrode. In the course of the titration the potential was established within less than 1 min, whereas at the TEP it was within about 2–3 min. The potential changes at the TEP were in the range from 60 to 200 mV per 0.1 ml EDTA, according to the stability constant of the complex formed. The highest potential changes, ranging from 160 to 200 mV, were obtained in the titration of iron(III) at pH 3.59. Reverse titration was also performed and accurate and reproducible results were obtained. Moreover, titration of halogenide and thiocyanate with standard mercury(II) solutions, as well as cyanide with silver(I) solution, were performed and accurate and reproducible results were again obtained. Received: 20 February 1998 / Accepted: 19 November 1999  相似文献   

15.
A procedure for estimation of measurement uncertainty of routine pH measurement (pH meter with two-point calibration, with or without automatic temperature compensation, combination glass electrode) based on the ISO method is presented. It is based on a mathematical model of pH measurement that involves nine input parameters. Altogether 14 components of uncertainty are identified and quantified. No single uncertainty estimate can be ascribed to a pH measurement procedure: the uncertainty of pH strongly depends on changes in experimental details and on the pH value itself. The uncertainty is the lowest near the isopotential point and in the center of the calibration line and can increase by a factor of 2 (depending on the details of the measurement procedure) when moving from around pH 7 to around pH 2 or 11. Therefore it is necessary to estimate the uncertainty separately for each measurement. For routine pH measurement the uncertainty cannot be significantly reduced by using more accurate standard solutions than ±0.02 pH units – the uncertainty improvement is small. A major problem in estimating the uncertainty of pH is the residual junction potential, which is almost impossible to take rigorously into account in the framework of a routine pH measurement.1 Received: 11 August 2001 Accepted: 22 February 2002  相似文献   

16.
Electrocatalytic reduction of hydrogen peroxide at Prussian blue modified electrode has been studied with rotating disk electrode in pH 5.5 and 7.3 solutions. It has been shown that the electrocatalytic cathodic reduction obeys Koutecky–Levich relationship at electrode potentials ranging from 0.1 to −0.4 V vs. Ag/AgCl for low concentrations of peroxide not exceeding 0.3 mM. Within this potential window, the calculated kinetic cathodic current ranges within the limits of 2.15–6.09 and 1.00–3.60 mA cm−2 mM−1 for pH 5.5 and 7.3, respectively. For pH 5.5 and 7.3 solutions, a linear slope of the dependence of kinetic current on electrode potential of −10.8 and −2.89 mA cm−2 mM−1 V−1, respectively, has been obtained. At a higher concentration of peroxide, exceeding 0.6 mM, deviations from Koutecky–Levich relationship have been observed. These deviations appear more expressed at higher potentials and higher solution pH. The results obtained have been interpreted within the frame of two-step reaction mechanism, including (1) dissociative adsorption of hydrogen peroxide with the formation of OH radicals and (2) one-electron reduction of these radicals to OH anions. At a higher concentration of peroxide, and especially at a higher pH, the second process becomes rate limiting.  相似文献   

17.
A PVC membrane electrode for zinc ions based on cryptand C2B22 as membrane carrier was prepared. The electrode exhibits a linear stable response over a wide concentration range (5.0 × 10–2– 5.0 × 10–5 mol/L) with a slope of 24 mV/ decade and a limit of detection of 3.98 × 10–5 mol/L (2.6 μg/g). It has a fast response time of about 30 s and can be used for at least 4 months without any divergence in potential. The proposed sensor revealed good selectivities for Zn2+ over a wide variety of other metal ions and could be used in a pH range of 4–7. It was used as an indicator electrode in potentiometric titration of zinc ion. Received: 26 February 1998 / Revised: 25 May 1998 / Accepted: 28 May 1998  相似文献   

18.
Abstract  In this study a design of an immunosensor for 1-nitropyrene is illustrated. First the response of 1-nitropyrene reduced at a glassy carbon electrode between 0 and −0.8 V was investigated with respect to pH and solvent. Then polyclonal anti-1-nitropyrene antibodies isolated from a rabbit antiserum were covalently bound to the surface of the glassy carbon electrode. This modified electrode was immersed in standard solutions or sample extracts for 5–15 min. 1-Nitropyrene was bound by the antibodies, accumulated and then analyzed at pH 6.5 in another supporting electrolyte by differential pulse voltammetry. Afterwards the immunosensor could be regenerated for the next measurement by rinsing with acetonitrile–water (40:60, v/v). A linear response was found between 20 and 100 ng/cm3. The limit of detection was 10 ng/cm3 and the intraday reproducibility of three immunosensors assembled during two months was between 4.5 and 10%. This sensor was applied to the analysis of 1-nitropyrene in air particulate matter and smoked tea. Graphical abstract     相似文献   

19.
Electrooxidation of ascorbate has been studied with the use of a rotating disk electrode. The results obtained show an efficient electrocatalytic oxidation of ascorbate at the Prussian blue (PB) modified electrode to proceed in solutions of pH 5.5 and 7.3. Depending on solution pH, the onset potential for ascorbate electrooxidation at PB modified electrode appears shifted by 0.1–0.2 V to lower values, as compared to an unmodified glassy carbon electrode. Within the electrode potential window of 0.3 to 0.5 V vs. Ag/AgCl, and electrode rotation velocity of 50–2000 rpm, the catalytic current obeys Koutecky-Levich equation at a submillimolar ascorbate concentration. Kinetic current densities, obtained from the data treatment, are higher for a pH 5.5 solution, and also at higher electrode potential.   相似文献   

20.
A Pt wire coated with a bentonite–carbon composite in a poly(vinyl chloride) membrane was used for detection of lead. The sensor has a Nernstian slope of 29.42±0.50 mV per decade over a wide range of concentration, 1.0×10−7 to 1.0×10−3 mol L−1 Pb(NO3)2. The detection limit is 5.0×10−8 mol L−1 Pb(NO3)2 and the electrode is applicable in the pH range 3.0–6.7. It has a response time of approximately 10 s and can be used at least for three months. The electrode has good selectivity relative to nineteen other metal ions. The practical analytical utility of the electrode is demonstrated by measurement of Pb(II) in industrial waste and river water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号