首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Microemulsion electrokinetic capillary chromatography (MEEKC) is a capillary electrophoresis technique in which neutral and ionized species can be resolved according to their partitioning into moving oil droplets present in the operating buffer. In this report, we present for the first time the application of MEEKC in the analysis of glycosaminoglycans. An efficient method for the separation of the variously sulfated delta-disaccharides obtained following digestion of chondroitin and dermatan sulfates with chondro/ dermato lyases and derivatization with 2-aminoacridone is described. Nonsulfated, mono-, di-, and trisulfated delta-disaccharides were completely separated using the microemulsion octane/butan-1-ol/Sodium dodecyl sulfate (SDS) in 10 mM borate buffer, pH 9.3, at 25 kV. Agreement of the obtained disaccharide composition with literature values showed that MEEKC can be used for the analysis of glycosaminoglycans.  相似文献   

2.
Micellar electrokinetic chromatography of proteins   总被引:1,自引:0,他引:1  
Micellar electrokinetic capillary chromatography (MECC) of proteins is a high resolution capillary electrophoretic (CE) analysis method that utilizes the hydrophobic and electrostatic interaction of protein analytes with surfactant micelles present in the buffer medium to facilitate separation. Through the manipulation of the protein-micelle interaction by the adjustment of variables such as surfactant concentration, solution pH, ionic strength, the presence of an organic modifier and the use of coated capillaries, MECC analyses of a wide variety of proteins have been optimized. MECC has been demonstrated to provide resolution of mixtures consisting of proteins with minor structural variations and also has provided the successful quantitative analysis of protein present in complex matrices. The adoption of protein MECC as a routine analytical technique may be dependent upon the successful interface of MECC with detection methodology, such as mass spectrometry, which can provide analyte characterization information.  相似文献   

3.
Microemulsion electrokinetic chromatography (MEEKC) was carried out in a pH 2.5 phosphate buffer to effectively suppress the electroosmotic flow (EOF). With 66.6% (w/w) 25 mM phosphate buffer pH 2.5, 20.0% (w/w) 2-propanol, 6.6% (w/w) 1-butanol, 6.0% (w/w) sodium lauryl sulphate (SDS), and 0.8% (w/w) n-octane as the separation medium, the fat-soluble vitamins A palmitate, E acetate, and D3 were baseline separated within 11 min. With strongly suppressed EOF, the polarity of the separation voltage was reversed (positive electrode at the outlet); the n-octane micro droplets surrounded by negatively charged SDS molecules migrated towards the detector. The aqueous part of the microemulsion was modified with 20% (w/w) 2-propanol to improve partition between the n-octane phase and the surrounding aqueous medium. The fat-soluble vitamins were separated in order of decreasing hydrophobicity with a high migration time stability (repeatable within 0.1% RSD). Excellent accuracy and precision were obtained when the system was applied for the determination of vitamin E acetate in commercial vitamin tablets; quantitative data corresponded to 97.0% of label claim, intra-day results varied within 1.72% RSD (n=6), and inter-day results varied within 3.22% RSD (n=5).  相似文献   

4.
The influence of microemulsion electrokinetic chromatography (MEEKC) operating conditions, such as the type of water-immiscible alcohol, aqueous phosphate buffer concentration, pH, as well as the addition of methanol and 2-propanol, on acrylamide migration has been studied. These parameters have been optimized taking into account the presence of matrix signals, in order to avoid the interference of these peaks in acrylamide determination. The best separations were achieved using a microemulsion consisting of 0.8% m/v n-amyl alcohol, 3.3% m/v sodium dodecyl sulfate (SDS), 6.6% m/v 1-butanol, and 89.3% m/v 40 mM phosphate buffer at pH 6.5 working at 15 kV in uncoated silica capillaries. Linear calibration curves over the range studied (1.25-125 microg x mL(-1)), the detection limit (0.70 microg x mL(-1)), and both run-to-run (up to 3.4% for concentration and 1.6% for time values) and day-to-day precision (lower than 11.6% for concentration) have been established. Finally, the applicability of the MEEKC method developed has been demonstrated by analyzing levels of acrylamide present in samples of home-made French fries.  相似文献   

5.
CZE is an appropriate technique for separating charged species, but lacks selectivity for neutral compounds. Alternative approaches such as microemulsion electrokinetic chromatography (MEEKC) have been developed to broaden its range of applications. Hyphenation of MEEKC with MS is an attractive perspective since it can enhance sensitivity and selectivity. The on-line coupling of MEEKC with MS, however, is not straightforward due to the low compatibility of non-volatile surfactant additives (e.g. SDS) and the commonly used API source, namely ESI. In order to hyphenate MEEKC with MS detection, the atmospheric pressure photoionization (APPI) source was investigated. Possibilities offered by the coupling of MEEKC with APPI-MS were highlighted for the complex separation of ionized and neutral compounds in both the positive and negative modes. MEEKC-APPI-MS performance, in terms of selectivity, efficiency and sensitivity was compared to CZE-ESI-MS and MEEKC-ESI-MS for the screening of doping substances (beta-blockers, central stimulants, diuretics, etc). Relevant selectivity and detectability, particularly for neutral, structurally related and isobaric compounds was demonstrated with the MEEKC-APPI-MS approach opening new avenues for CE-MS, in addition to the well-established CZE-ESI-MS technique.  相似文献   

6.
Microemulsion EKC (MEEKC) was developed for quantitative analysis of curcuminoids, such as curcumin (C), demethoxycurcumin (D), and bis-demethoxycurcumin (B). MEEKC separation of curcuminoids was optimized, and a change in resolution was explained using a modified equation for resolution in MEEKC without electroosmosis. The suitable MEEKC conditions for separation of curcuminoids were obtained to be the microemulsion buffer containing 50 mM phosphate buffer at pH 2.5, 1.1% v/v n-octane as oil droplets, 180 mM SDS as surfactant, 890 mM 1-butanol as cosurfactant, and 25% v/v 2-propanol as organic cosolvent; applied voltage of -15 kV; and separation temperature 25 degrees C. Achieved baseline resolution of C:D and D:B was obtained with R(s) -2.4 and analysis time within 18 min. In addition, high accuracy and precision of the method were obtained. This MEEKC method was used for quantitative determination of individual curcuminoids in medicinal turmeric capsules and powdered turmeric used as coloring additive in food, with simple sample preparation such as solvent extraction, dilution, and filtration, and without cleaning up by SPE.  相似文献   

7.
The separation of neutral hydrophobic corticosteroids (cortisone, cortisone acetate, hydrocortisone, hydrocortisone acetate, prednisolone and prednisolone acetate) by microemulsion electrokinetic chromatography (MEEKC) was studied. In the preparation of microemulsion, heptane was the solvent, n-butanol the co-surfactant and, as anionic surfactants, sodium dodecyl sulfate (SDS) or taurodeoxycholic acid sodium salt (STDC) were employed. Using an acidic running buffer, (phosphate pH 2.5) a strong suppression of the electroosmotic flow (EOF) was observed; this resulted in a fast anodic migration of the analytes partitioned into the negatively charged microemulsion droplets. Under these conditions, STDC showed better separation of corticosteroids than the conventional SDS; however, the use of a single anionic surfactant did not provide the required selectivity. The addition of the neutral surfactant polyoxyethylene glycol octadecyl ether (Brij 76) significantly altered the migration of each analytes allowing a better tuning of separation; however, in order to obtain adequate resolution between couples of adjacent critical peaks, the addition of neutral cyclodextrins (CDs) was found to be essential. This apparently complex system (CD-MEEKC), was optimized by studying the effect of the most important parameters affecting separation: STDC concentration, Brij 76 concentration, nature and concentration of cyclodextrins. Following a rational step-by-step approach, the optimised conditions providing the complete separation of the analytes were found to be: 4.0% STDC, 2.5% Brij 76, 6.6% n-butanol, 1.36% heptane and 85.54% of a solution 5 mM beta-CD in 50 mM phosphate buffer (pH 2.5). The optimized system was preliminary applied to the detection of corticosteroids related substances at impurity level and it could be considered a useful orthogonal alternative to HPLC methods.  相似文献   

8.
In this paper, we present the determination of pharmaceuticals employing microemulsion electrokinetic chromatography (MEEKC) with atmospheric pressure photoionization-mass spectrometric (APPI-MS) detection. This recent hyphenated technique allows to overcome some disadvantages of MEEKC, namely its inherent incompatibility with MS detection. Important parameters like microemulsion (ME) composition, the composition of the sheath liquid and APPI-MS detection parameters have been investigated. Using the optimized set of parameters, the eight selected substances could be detected down to concentrations between 3 mg L(-1) (phenacetin) and 41 mg L(-1) (diltiazem). Switching to the MS2 mode, the use of specific transitions for the detection of each analyte provided improved detection limits in the range of 0.6 mg L(-1) (carbamazepine) to 6 mg L(-1) (metoprolol). Calibration curves were linear over one to two orders of magnitude with correlation coefficients better than 0.98.  相似文献   

9.
A microemulsion electrokinetic chromatographic method was used to separate fat-soluble vitamins. The separation of retinol, cholecalciferol, and delta- and alpha-tocopherol was performed using a microemulsion containing 0.75% (v/v) n-heptane, 30 mM bis(2-ethylhexyl)sodium sulfosuccinate (AOT), 5% (v/v) 1-butanol, 15% (v/v) 1-propanol and 15% (v/v) methanol in 20mM boric acid-sodium borate buffer. The effect of the different microemulsion constituents was studied, including the type and concentration of surfactant, buffer, oil and co-surfactants. The presence of methanol in the microemulsion was found to be necessary to achieve the separation of the tocopherols. Detection was carried out at 200, 265 and 325 nm for the tocopherols, cholecalciferol and retinol, respectively. Calibration curves and precision data were obtained for each analyte. Good linear relationships were found between the analytical signal and the analytes concentration in the 25-500 mg L(-1) for retinol and cholecalciferol, and 25-300 mg L(-1) for tocopherols ranges. The precision of the method afforded relative standard deviations in the 4.0-10% range.  相似文献   

10.
Microemulsion electrokinetic chromatography was applied for the separation of levetiracetam from other antiepileptic drugs (primidone, phenobarbital, phenytoin, lamotrigine and carbamazepine) that are potentially coadministered in therapy of patients. The influence of the composition of the microemulsion system (with sodium dodecyl sulfate as charged surfactant) was investigated, modifying the kind of cosurfactant (lower alcohols from C3 to C5), the pH (and salinity) of the aqueous background electrolyte, and the ratio of aqueous phase to organic constituents forming the microdroplets of the oil-in-water emulsion. Separation selectivity was depending on all these parameters, resulting even in changes of the migration sequence of the analytes. Only moderate correlation was observed for the microemulsion system compared with a micellar system, both consisting of the aqueous borate buffer (pH 9.2) and SDS as micelle former (linear correlation coefficient for analyte mobilities is 0.974). The sample solvent plays an important role on the shape of the resulting chromatograms: methanol at concentrations higher than 35% impairs peak shape and separation efficiency. The microemulsion method (with 93.76% aqueous borate buffer (pH 9.2, 10 mM), 0.48% n-octane, 1.80% SDS, 3.96% 1-butanol, all w/w) is suitable for the determination of levetiracetam in human plasma (combined with a sample pretreatment based on solid-phase extraction).  相似文献   

11.
Zhang J  Xie J  Liu J  Tian J  Chen X  Hu Z 《Electrophoresis》2004,25(1):74-79
A selective and sensitive microemulsion electrokinetic chromatography with laser-induced fluorescence detection method was developed for the quantification of ephedrine (E) and pseudoephedrine (PE) derivatized with 4-chloro-7-nitrobenzo-2-oxa-1, 3-diazol. By a series of optimization, a running buffer composed of 20 mM borate + microemulsion (23.3 mM Sodium dodecyl sulfate/180.85 mM 1-butanol/16.4 mM n-heptane) +8% acetonitrile was applied for the separation of the derivatives. A linear relationship for E and PE was obtained in the range of 0.058-11.58 microg.mL(-1) (correlation coefficient: 0.9993 for E, 0.9995 for PE), and the detection limits for E and PE were 5.3 and 3.9 ng.mL(-1). The method was applied to the analysis of the two alkaloids in Chinese traditional herbal preparations with recoveries in the range of 96.9-105.4%.  相似文献   

12.
In previous reports of microemulsion electrokinetic chromatography (MEEKC), analysis times were typically in the order of 10 min as high-ionic strength buffers were used. These buffers produced high currents which limit the voltages which can be applied, therefore, analysis times could not be reduced. The primary cause of the high-ionic strength is the relatively high concentrations of surfactants required to form the microemulsion. The surfactant concentration can be lower when using an oil with a smaller surface tension. This preliminary study showed that migration times in MEEKC can be reduced to below 1 min by using a combination of an optimum microemulsion composition, high voltage, high temperature, short capillaries by injecting via the "short end", or by simultaneously applying pressure and voltage. Long injection sequences and quantitation were found to be possible with minimum buffer depletion effects.  相似文献   

13.
Over a decade ago, microemulsion electrokinetic chromatography was introduced as a novel mode of capillary electrophoresis. However, there has not been publication on the combination of microemulsion electrokinetic chromatography with laser-induced fluorescence detection. In this paper, a preliminary method using microemulsion eletrokinetic chromatography combined with laser-induced fluorescence detection and second derivative electrophoregram was established as a sensitive and selective assay for separation and determination of nine amino acids after derivatization with 4-chloro-7-nitrobenzo-2-oxa-1, 3-diazol. The derivatization and separation conditions were optimized. In the investigated concentration ranges correlation coefficients were better than 0.995. The relative standard deviation (n = 5) of the migration times and peak heights were 0.56-0.76 and 2.21-7.15%, respectively. The detection limits (S/N = 3) were at a neaomolar level (0.32-2.20 nM). The method was applied for the analysis of compound amino acid injection and a Chinese traditional herbal medicine. The recoveries were 95.9-107.9%.  相似文献   

14.
A new hexane-in-water microemulsion was investigated as buffer in microemulsion EKC (MEEKC). At difference with other microemulsions, the addition of cosurfactant was not necessary to stabilize the microemulsion. The proposed microemulsion was successfully used to achieve electrophoretic separation of seven antibiotics including nitroimidazoles, cephapirin and tetracyclines. Selectivity and separation efficiency achieved in MEEKC were compared with MEKC. MEEKC technique proved to be more efficient than MEKC for performing the separation of the analytes and the presence of microemulsions was found to be critical to achieve the separation of tetracyclines. The proposed microemulsion also points out that solvents with high volatility, such as hexane, can be stabilized and used as a microemulsion of SDS.  相似文献   

15.
Li Q  Chang CK  Huie CW 《Electrophoresis》2005,26(4-5):885-894
An investigation of the basic factors which govern the microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatography (MEKC) separation of Hematoporphyrin D and its base hydrolysis product, hematoporphyrin derivative (HpD), was performed. These model compounds contain a complex mixture of porphyrin monomers, dimers and/or oligomers, and were utilized to gain insights into the MEEKC/micellar electrokinetic chromatography (MEKC) separation of samples containing highly lipophilic substances. For example, the organic modifier/cosurfactant (1-butanol) and/or oil phase (e.g., 1-octanol in comparison to ethyl acetate) were found to have an apparent influence on the separation selectivity of Hematoporphyrin D, the extent of which was dependent on the chemical nature of the surfactant employed (e.g., sodium dodecyl sulfate vs. sodium cholate). An interesting and important finding was that the presence of an organic modifier (methanol or acetonitrile at a concentration of 20% or higher) in the sample matrix as well as in the run buffer was essential for the optimal MEEKC or MEKC separation of a number of porphyrin monomers (including hematoporphyrin IX and its acetates, most likely hydroxyacetate, diacetate, and vinyl acetate, as well as its dehydration products, hydroxyethylvinyldeuteroporphyrin and protoporphyrin) contained in Hematoporphyrin D. On the other hand, the use of these optimized conditions for the MEEKC or MEKC separation of various oligomeric porphyrin species in HpD were unsatisfactory. As HpD is a well-known and effective photosensitizing agent in photodynamic therapy (a new approach for cancer treatment), the improved separation and characterization of various monomeric and oligomeric porphyrin species in HpD and its starting material, such as Hematoporphyrin D, is a challenging and important task.  相似文献   

16.
Benzodiazepines, namely flunitrazepam and its three major metabolites, were successfully separated by microemulsion electrokinetic chromatography. Separation was achieved using an untreated fused-silica capillary (48 cm (effective length 40 cm) x 50 num) at 25 kV; detection was performed by UV at 220 nm. The microemulsion system consisted of 70 mM octane, 800 mM 1-butanol, 80 mM sodium dodecyl sulfate (SDS) and 10 mM borate buffer, pH 9. Very high efficiencies (up to 400 000 plates) and resolution better than 3 were achieved. Since this technique is not compatible with mass spectrometry (MS) detection, a capillary electrochromatographic (CEC) method was developed to separate flunitrazepam and its metabolites. The effects of mobile phase composition and pH as well as voltage and temperature were systematically investigated. The optimized CEC method allowed the baseline separation of the investigated compounds. For the on-line coupling of CEC with electrospray ionization-mass spectrometry, the column was connected to a void fused-silica capillary using a Teflon connection. This configuration was found efficient and suitable for hyphenation of commercial CEC and MS instrumentation using commercially available CEC columns.  相似文献   

17.
18.
19.
The feasibility of microwave-accelerated derivatization for capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was evaluated. The derivatization reaction was performed in a domestic microwave oven. Histidine (His), 1-methylhistidine (1-MH) and 3-methylhistidine (3-MH) were selected as test analytes and fluorescein isothiocyanate (FITC) was chosen as a fluorescent derivatizing reagent. Parameters that may affect the derivatization reaction and/or subsequent CE separation were systematically investigated. Under optimized conditions, the microwave-accelerated derivatization reaction was successfully completed within 150 s, compared to 4-24 h in a conventional water-bath derivatization process. This will remarkably reduce the overall analysis time and increase sample throughput of CE-LIF. The detection limits of this method were found to be 0.023 ng/mL for His, 0.023 ng/mL for 1-MH, and 0.034 ng/mL for 3-MH, respectively, comparable to those obtained using traditional derivatization protocols. The proposed method was characterized in terms of precision, linearity, accuracy and successfully applied for rapid and sensitive determination of these analytes in human urine.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号