首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this study, we compare near-infrared (NIR) and Raman spectroscopy for the determination of the density of linear low density polyethylene (PE) (in a pellet form). As generally known, Raman spectral features are more selective than those of NIR for most chemical samples. NIR spectroscopy has been more extensively used for the quantitative analysis of polymers, but Raman spectroscopy is the better choice as long as the problem of reproducibility of Raman measurements (especially for solid samples), mostly resulting from insufficient sample representation due to probing only localized chemical information and the sensitivity of sample placement with regard to the focal plane, can be overcome. To improve sample representation and reproducibility of Raman measurements, we have employed the wide area illumination (WAI) Raman scheme, capable of illuminating a laser onto a large sample area (28.3 mm2) for Raman spectral collection (a 6-mm laser spot with a focal length of 248 mm). Diffuse reflectance NIR spectra of PE pellets were collected using a sample moving system which allowed for the scanning of large areas. The prediction error was 0.0008 g cm−3 for Raman spectroscopy and 0.0011 g cm−3 for NIR spectroscopy. The harmonization of inherently selective Raman features and a reproducible spectral collection with correct sample representations using the WAI scheme led to an accurate determination of the density of the PE pellets.  相似文献   

2.
Using near infrared (NIR) and Raman spectroscopy as PAT tools, 3 critical quality attributes of a silicone-based drug reservoir were studied. First, the Active Pharmaceutical Ingredient (API) homogeneity in the reservoir was evaluated using Raman spectroscopy (mapping): the API distribution within the industrial drug reservoirs was found to be homogeneous while API aggregates were detected in laboratory scale samples manufactured with a non optimal mixing process. Second, the crosslinking process of the reservoirs was monitored at different temperatures with NIR spectroscopy. Conformity tests and Principal Component Analysis (PCA) were performed on the collected data to find out the relation between the temperature and the time necessary to reach the crosslinking endpoints. An agreement was found between the conformity test results and the PCA results. Compared to the conformity test method, PCA had the advantage to discriminate the heating effect from the crosslinking effect occurring together during the monitored process. Therefore the 2 approaches were found to be complementary. Third, based on the HPLC reference method, a NIR model able to quantify the API in the drug reservoir was developed and thoroughly validated. Partial Least Squares (PLS) regression on the calibration set was performed to build prediction models of which the ability to quantify accurately was tested with the external validation set. The 1.2% Root Mean Squared Error of Prediction (RMSEP) of the NIR model indicated the global accuracy of the model. The accuracy profile based on tolerance intervals was used to generate a complete validation report. The 95% tolerance interval calculated on the validation results indicated that each future result will have a relative error below ±5% with a probability of at least 95%. In conclusion, 3 critical quality attributes of silicone-based drug reservoirs were quickly and efficiently evaluated by NIR and Raman spectroscopy.  相似文献   

3.
Near-infrared imaging systems simultaneously record spectral and spatial information. Each measurement generates a data cube containing several thousand spectra. Chemometric methods are therefore required to extract qualitative and quantitative information. The aim of this study was to determine the feasibility of quantifying active pharmaceutical ingredient (API) and excipient content in pharmaceutical formulations using hyperspectral imaging.Two kinds of tablets with a range of API content were analysed: a binary mixture of API and cellulose, and a pharmaceutical formulation with seven different compounds. Two pixel sizes, 10 μm/pixel and 40 μm/pixel, were compared, together with two types of spectral pretreatment: standard normal variate (SNV) normalization and Savitzky-Golay smoothing. Two methods of extracting concentrations were compared: the partial least squares 2 (PLS2) algorithm, which predicts the content of several compounds simultaneously, and the multivariate classical least squares (CLS) algorithm based on pure compound reference spectra without calibration.Best content predictions were achieved using 40 μm/pixel resolution and the PLS2 method with SNV normalized spectra. However, the CLS method extracted distribution maps with higher contrast and was less sensitive to noisy spectra and outliers; its API predictions were also highly correlated to real content, indicating the feasibility of predicting API content using hyperspectral imaging without calibration.  相似文献   

4.
We demonstrate the potential of Raman spectroscopy to detect cocaine concealed inside transparent glass bottles containing alcoholic beverages. A clear Raman signature of cocaine with good signal-to-noise was obtained from a ∼300 g solution of adulterated cocaine (purity 75%) in a 0.7 L authentic brown bottle of rum with 1 s acquisition time. The detection limit was estimated to be of the order of 9 g of pure cocaine per 0.7 L (∼0.04 moles L−1) with 1 s acquisition time. The technique holds great promise for the fast, non-invasive, detection of concealed illicit compounds inside beverages using portable Raman instruments, thus permitting drug trafficking to be combated more effectively.  相似文献   

5.
The aim of the present study was to examine the possibilities/advantages of using recently introduced in-line spectroscopic process analyzers (Raman, NIR and plasma emission spectroscopy), within well-designed experiments, for the optimization of a pharmaceutical formulation and its freeze-drying process. The formulation under investigation was a mannitol (crystalline bulking agent)-sucrose (lyo- and cryoprotector) excipient system. The effects of two formulation variables (mannitol/sucrose ratio and amount of NaCl) and three process variables (freezing rate, annealing temperature and secondary drying temperature) upon several critical process and product responses (onset and duration of ice crystallization, onset and duration of mannitol crystallization, duration of primary drying, residual moisture content and amount of mannitol hemi-hydrate in end product) were examined using a design of experiments (DOE) methodology. A 2-level fractional factorial design (25−1 = 16 experiments + 3 center points = 19 experiments) was employed. All experiments were monitored in-line using Raman, NIR and plasma emission spectroscopy, which supply continuous process and product information during freeze-drying. Off-line X-ray powder diffraction analysis and Karl-Fisher titration were performed to determine the morphology and residual moisture content of the end product, respectively.In first instance, the results showed that - besides the previous described findings in De Beer et al., Anal. Chem. 81 (2009) 7639-7649 - Raman and NIR spectroscopy are able to monitor the product behavior throughout the complete annealing step during freeze-drying. The DOE approach allowed predicting the optimum combination of process and formulation parameters leading to the desired responses. Applying a mannitol/sucrose ratio of 4, without adding NaCl and processing the formulation without an annealing step, using a freezing rate of 0.9 °C/min and a secondary drying temperature of 40 °C resulted in efficient freeze-drying supplying end products with a residual moisture content below 2% and a mannitol hemi-hydrate content below 20%. Finally, using Monte Carlo simulations it became possible to determine how varying the factor settings around their optimum still leads to fulfilled response criteria, herewith having an idea about the probability to exceed the acceptable response limits. This multi-dimensional combination and interaction of input variables (factor ranges) leading to acceptable response criteria with an acceptable probability reflects the process design space.  相似文献   

6.
The active pharmaceutical ingredient (ambroxol) in an intact capsule formulation has been non-destructively quantified using Raman spectroscopy. To improve the problem of insufficient representive sampling inherent in Raman measurements, we have employed a wide area illumination (WAI) scheme that enables much improved sample coverage through a circular excitation laser spot with a 6 mm diameter. One of the anticipated sources of variation for this measurement was variation in the capsule shells. However, the WAI scheme significantly decreased the spectral variation among empty capsules compared to a measurement with a traditional small-spot excitation. Therefore, measurement variations emanating from the capsule shell did not significantly influence the accuracy of the determination of ambroxol concentrations. The resulting standard error of prediction (SEP) using the WAI scheme was comparable to that from previous Raman measurements which used a conventional small-spot excitation and employed a sampling scheme that involved rotation of an ambroxol pellet. It is further noteworthy that the SEP was also similar to that obtained from the use of transmission NIR spectroscopy, which was achieved by collection of spectra of the powdered capsule contents removed from the shell. The proposed Raman measurement using the WAI scheme in this case was sufficient to achieve the quantitative measurement of the active pharmaceutical ingredient (API) content of capsules non-destructively.  相似文献   

7.
Raman spectroscopy was applied for the direct non-destructive analysis of amiodarone hydrochloride (ADH), the active ingredient of the liquid formulation Angoron®. The FT-Raman spectra were obtained through the un-broken as-received ampoules of Angoron®. Using the most intense vibration of the active pharmaceutical ingredient (API) at 1568 cm−1, a calibration model, based on solutions with known concentrations, was developed. The model was applied to the Raman spectra recorded from three as-purchased commercial formulations of Angoron® having nominal strength of 50 mg ml−1 ADH. The average value of the API in these samples was found to be 48.56 ± 0.64 mg ml−1 while the detection limit of the proposed technique was found to be 2.11 mg ml−1. The results were compared to those obtained from the application of HPLC using the methodology described in the European Pharmacopoeia and found to be in excellent agreement. The proposed analytical methodology was also validated by evaluating the linearity of the calibration line as well as its accuracy and precision. The main advantage of Raman spectroscopy over HPLC method during routine analysis is that it is considerably faster and no solvent consuming. Furthermore, Raman spectroscopy is non-destructive for the sample. However, the detection limit for Raman spectroscopy is much higher than the corresponding for the HPLC methodology.  相似文献   

8.
The concentration of acetaminophen in a turbid pharmaceutical suspension has been measured successfully using Raman spectroscopy. The spectrometer was equipped with a large spot probe which enabled the coverage of a representative area during sampling. This wide area illumination (WAI) scheme (coverage area 28.3 mm2) for Raman data collection proved to be more reliable for the compositional determination of these pharmaceutical suspensions, especially when the samples were turbid. The reproducibility of measurement using the WAI scheme was compared to that of using a conventional small-spot scheme which employed a much smaller illumination area (about 100 μm spot size). A layer of isobutyric anhydride was placed in front of the sample vials to correct the variation in the Raman intensity due to the fluctuation of laser power. Corrections were accomplished using the isolated carbonyl band of isobutyric anhydride. The acetaminophen concentrations of prediction samples were accurately estimated using a partial least squares (PLS) calibration model. The prediction accuracy was maintained even with changes in laser power. It was noted that the prediction performance was somewhat degraded for turbid suspensions with high acetaminophen contents. When comparing the results of reproducibility obtained with the WAI scheme and those obtained using the conventional scheme, it was concluded that the quantitative determination of the active pharmaceutical ingredient (API) in turbid suspensions is much improved when employing a larger laser coverage area. This is presumably due to the improvement in representative sampling.  相似文献   

9.
Kim J  Kim Y  Chung H 《Talanta》2011,83(3):879-884
We demonstrated an on-line Raman measurement of polyethylene (PE) pellet density when it is flying in a sample line. While in flight, pellets are sparsely populated at spectral collection, a spectral collection strategy covering a large spatial volume (larger number of pellets simultaneously) is necessary to acquire reasonable Raman intensity. In addition, the Raman measurement must be less sensitive to pellet position, because position and distribution are uncontrollable in a flying condition. To fulfill these requirements, a wide area illumination (WAI) scheme capable of covering a large sample volume (illumination volume: 0.7 cm3) was used when the pellets were flying in a 2.5-cm-diameter sample line. In addition, a long focal length (250 mm) was used so that minor changes in pellet position would not significantly affect the resulting Raman spectral feature. Although Raman intensity substantially decreased due to the large void space among flying pellets, a correct spectral feature representing PE was successfully obtained without any significant spectral distortion. Using partial least squares (PLS) regression, the prediction error under flying conditions was 0.0009 g cm−3, which was comparable to that acquired when the pellets were packed (0.0008 g cm−3). When a conventional Raman scheme covering a smaller sample volume with a short focal length was used, the PE intensity decreased dramatically, and the resulting signal-to-noise ratio was not proper for quantitative analysis.  相似文献   

10.
This work describes a general framework for assessing the active pharmaceutical ingredient (API) and excipient concentrations simultaneously in pharmaceutical dosage forms based on laboratory-scale measurements. The work explores the comprehensive development of a near infrared (NIR) analytical protocol for the quantification of the API and excipients of a pharmaceutical formulation. The samples were based on a paracetamol (API) formulation with three excipients: microcrystalline cellulose, talc, and magnesium stearate. The developed method was based on laboratory-scale samples as calibration samples and pilot-scale samples (powders and tablets) as model test samples. Both types of samples were produced according to an experimental design. The samples were measured in reflectance mode in a Fourier-transform NIR spectrometer. Additionally, a new method for determining the minimum number of calibration samples was proposed. It was concluded that the use of laboratory-scale samples to construct the calibration set is an effective way to ensure the concentration variability in the development of calibration models for industrial applications. With this method, both API and excipients can be determined in high-throughput applications in the pharmaceutical industry.  相似文献   

11.
Raman spectra of intramolecular vibration mode for each guest species in the methane + tetrafluoromethane (CF4) mixed-gas hydrate crystal have been measured at 291.1 K. Both of pure guest species generate the structure-I hydrate in the present pressure ranges. Isothermal phase-equilibrium curve exhibits two discontinuous points around the equilibrium methane compositions (water-free) in the gas phase of 0.3 and 0.8. At the above points, the Raman spectra of both guest molecules have been drastically changed. One of the most important findings is that the crystal of methane + tetrafluoromethane mixed-gas hydrate shows the structural phase-transition (from the structure-I to the structure-II and back to the structure-I) caused by composition changes.  相似文献   

12.
This work evaluates the use of near-infrared (NIR) overtone regions to determine biodiesel content, as well potential adulteration with vegetable oil, in diesel/biodiesel blends. For this purpose, NIR spectra (12,000–6300 cm−1) were obtained using three different optical path lengths: 10 mm, 20 mm and 50 mm. Two strategies of regression with variable selection were evaluated: partial least squares (PLS) with significant regression coefficients selected by Jack-Knife algorithm (PLS/JK) and multiple linear regression (MLR) with wavenumber selection by successive projections algorithm (MLR/SPA). For comparison, the results obtained by using PLS full-spectrum models are also presented. In addition, the performance of models using NIR (1.0 mm optical path length, 9000–4000 cm−1) and MIR (UATR – universal attenuated total reflectance, 4000–650 cm−1) spectral regions was also investigated. The results demonstrated the potential of overtone regions with MLR/SPA regression strategy to determine biodiesel content in diesel/biodiesel blends, considering the possible presence of raw oil as a contaminant. This strategy is simple, fast and uses a fewer number of spectral variables. Considering this, the overtone regions can be useful to develop low cost instruments for quality control of diesel/biodiesel blends, considering the lower cost of optical components for this spectral region.  相似文献   

13.
Near-infrared calibration models were developed for the determination of content uniformity of pharmaceutical tablets containing 29.4% drug load for two dosage strengths (X and Y). Both dosage strengths have a circular geometry and the only difference is the size and weight. Strength X samples weigh approximately 425 mg with a diameter of 12 mm while strength Y samples, weigh approximately 1700 mg with a diameter of 20 mm. Data used in this study were acquired from five NIR instruments manufactured by two different vendors. One of these spectrometers is a dispersive-based NIR system while the other four were Fourier transform (FT) based. The transferability of the optimized partial least-squares (PLS) calibration models developed on the primary instrument (A) located in a research facility was evaluated using spectral data acquired from secondary instruments B, C, D and E. Instruments B and E were located in the same research facility as spectrometer A while instruments C and D were located in a production facility 35 miles away. The same set of tablet samples were used to acquire spectral data from all instruments. This scenario mimics the conventional pharmaceutical technology transfer from research and development to production. Direct cross-instrument prediction without standardization was performed between the primary and each secondary instrument to evaluate the robustness of the primary instrument calibration model. For the strength Y samples, this approach was successful for data acquired on instruments B, C, and D producing root mean square error of prediction (RMSEP) of 1.05, 1.05, and 1.22%, respectively. However for instrument E data, this approach was not successful producing an RMSEP value of 3.40%. A similar deterioration was observed for the strength X samples, with RMSEP values of 2.78, 5.54, 3.40, and 5.78% corresponding to spectral data acquired on instruments B, C, D, and E, respectively. To minimize the effect of instrument variability, calibration transfer techniques such as piecewise direct standardization (PDS) and wavelet hybrid direct standardization (WHDS) were used. The PDS approach, the RMSEP values for strength X samples were lowered to 1.22, 1.12, 1.19, and 1.08% for instruments B, C, D, and E, respectively. Similar improvements were obtained using the WHDS approach with RMSEP values of 1.36, 1.42, 1.36, and 0.98% corresponding to instruments B, C, D, and E, respectively.  相似文献   

14.
The assessment of active pharmaceutical ingredient (API) particle size and morphology is of great importance for the pharmaceutical industry since it is expected to significantly affect physicochemical properties. However, very few methods are published for the determination of API morphology and particle size of film-coated (FC) tablets. In the current study we provide a methodology for the measurement of API particle size and morphology which could be applied in several final products. Bismuth Oxide 120 mg FC Tabs were used for our method development, which contain bismuth oxide (as tripotassium dicitratobismuthate (bismuth subcitrate)) as the active substance. The sample preparation consists of partial excipient dissolution in different solvents. Following this procedure, the API particles were successfully extracted from the granules. Particle size and morphology identification in Bismuth Oxide 120 mg FC Tabs was conducted using micro-Raman mapping spectroscopy and ImageJ software. The proposed methodology was repeated for the raw API material and against a reference listed drug (RLD) for comparative purposes. The API particle size was found to have decreased compared to the raw API, while the API morphology was also affected from the formulation manufacturing process. Comparison with the RLD product also revealed differences, mainly in the API particle size and secondarily in the crystal morphology.  相似文献   

15.
Tear fluid is a complex aqueous solution containing proteins, metabolites, electrolytes and lipids. This study uses Raman spectroscopy to analyse the composition of human tear fluid from three healthy volunteers. Two different methods are used to obtain Raman spectra from the 3 μL tear samples: (i) solution-phase Raman spectroscopy, and (ii) drop coating deposition Raman spectroscopy (DCDRS). Tear samples were either basal fluid, or yawn reflex secreted fluid. Calibration of the solution technique with standard protein solutions (5-15 mg mL−1) showed that this method could predict the protein concentration (cross-validation) with an error of less than 1 mg mL−1. The Raman signals from the tear fluid were very weak but signals due to protein and urea were clearly observable in all samples. The drop coating deposition technique was shown to produce very high signal-to-noise spectra for relatively short acquisition times, and small sample volumes. Raman point mapping combined with principal components analysis showed that the protein, urea, bicarbonate and lipid could all be detected in the tear samples and that the distribution of these components was inhomogeneous. Their position within the drying pattern was shown to depend on their relative solubilities. The results of this study suggest that solution Raman measurements may be calibrated to give the total tear protein concentration and DCDRS could be used to give a fingerprint of the tear protein (and lipid) composition.  相似文献   

16.
A visible light induced photoelectrochemical biosensing platform based on oxygen-sensitive near-infrared quantum dots (NIR QDs) was developed for detection of glucose. The NIR QDs were synthesized in an aqueous solution, and characterized with scanning electron microscopy and X-ray photoelectron spectroscopy. The as-prepared NIR QDs were employed to construct oxygen-sensitive photoelectrochemical biosensor on a fluorine-doped tin oxide (FTO) electrode. The oxygen dependency of the photocurrent was investigated at as-prepared electrode, which demonstrated the signal of photocurrent is suppressed with the decreasing of oxygen. Coupling with the consumption of oxygen during enzymatic reaction, a photoelectrochemical strategy was proposed for the detection of substrate. Using glucose oxidase (GOx) as a model enzyme, that is, GOx was covalently attached to the surface of CdTe QDs, the resulting biosensor showed the sensitive response to glucose. Under the irradiation of visible light of a wavelength at 505 nm, the proposed photoelectrochemical method could detect glucose ranging from 0.1 mM to 11 mM with a detection limit of 0.04 mM. The photoelectrochemical biosensor showed a good performance with high upper detection limit, acceptable stability and accuracy, providing an alternative method for monitoring biomolecules and extending the application of near-infrared QDs.  相似文献   

17.
The present study focuses on the development of a new route for the synthesis of pure nickel borate nanoparticles using reverse micellar route. Nickel borate nanoparticles (25 nm) were synthesized from a precursor (obtained by reverse micellar route) containing both nickel and boron (nickel nitrate and sodium borohydride as starting materials). Decomposition of the precursor at a temperature of ∼800 °C yielded pure nickel borate nanoparticles. This was confirmed by powder X-ray diffraction and transmission electron microscopy. These nanoparticles show an antiferromagnetic ordering with N?el temperature of 47 K.  相似文献   

18.
Many studies have reported the use of near infrared (NIR) spectroscopy to characterize wines or to predict wine chemical composition. However, little is known about the effect of variation in temperature on the NIR spectrum of wine and the subsequent effect on the performance of calibrations used to measure chemical composition. Several parameters influence the spectra of organic molecules in the NIR region, with temperature being one of the most important factors affecting the vibration intensity and frequency of molecular bonds. Wine is a complex mixture of chemical components (e.g. water, sugars, organic acids, and ethanol), and a simple ethanol and water model solution cannot be used to study the possible effects of temperature variations in the NIR spectrum of wine. Ten red and 10 white wines were scanned in triplicate at six different temperatures (25 °C, 30 °C, 35 °C, 40 °C, 45 °C and 50 °C) in the visible (vis) and NIR regions (400-2500 nm) in a monochromator instrument in transmission mode (1 mm path length). Principal component analysis (PCA) and partial least squares (PLS) regression models were developed using full cross validation (leave-one-out). These models were used to interpret the spectra and to develop calibrations for alcohol, sugars (glucose + fructose) and pH at different temperatures. The results showed that differences in the spectra around 970 nm and 1400 nm, related to OH bonding were observed for both varieties. Additionally an effect of temperature on the vis region of red wine spectra was observed. The standard error of cross validation (SECV) achieved for the PLS calibration models tended to inverse as the temperature increased. The practical implication of this study it is recommended that the temperature of scanning for wine analysis using a 1 mm path length cuvette should be between 30 °C and 35 °C.  相似文献   

19.

Alogliptin (ALG) is a hypoglycemic drug used in diabetes which inhibits the enzyme dipeptidyl peptidase-4 (DPP-4), preventing the degradation of incretins, stimulating insulin secretion. The physicochemical characteristics of ALG were evaluated by differential scanning calorimetry (DSC), thermogravimetry (TG) and scanning electron microscopy equipped with energy-dispersive X-ray spectrometer (SEM/EDS). The compatibility studies were carried out between ALG and excipients (physical mixtures, 1:1) using DSC, TG, diffuse reflectance Fourier transform infrared spectroscopy (FTIR), X-ray powder diffraction (XRPD) and hot-stage microscopy. ALG presented purity near to 99%, melted in the range of 179.4–187.2 °C, followed by decomposition which started in 198.0 °C. SEM/EMS analysis of ALG presented irregular crystals and traces of impurities as copper and lead. DSC investigations obtained by physical mixtures showed minor alterations in the melting ranges of ALG with mannitol, magnesium stearate and commercial tablets. Solubilization of ALG in the fused excipient was observed by hot-stage microscopy between mannitol and ALG, and in tablets. The interaction observed in the mixture with magnesium stearate is due to the melting of the excipient and drug separately, first the excipient and then the drug. FTIR showed additional bands related to the excipients. XRPD proved that ALG has a crystal form and no alterations in the ALG profile were observed after the mixtures. ALG was compatible with all excipients tested. These results were important to understand the characteristics, stability and compatibility of the drug, and proved to be useful in preformulation studies.

  相似文献   

20.
A new type of tryptophan-functionalized graphene nanocomposite (Trp-GR) was synthesized by utilizing a facile ultrasonic method via ππ conjugate action between graphene (GR) and tryptophan (Trp) molecule. The material as prepared had well dispersivity in water and better conductivity than pure GR. The surface morphology of Trp-GR was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Raman spectroscopy. The electrochemical behaviors of ascorbic acid (AA), dopamine (DA), and uric acid (UA) were investigated by cyclic voltammetry (CV) on the surface of Trp-GR. The separation of the oxidation peak potentials for AA–DA, DA–UA and UA–AA was about 182 mV, 125 mV and 307 mV, which allowed simultaneously determining AA, DA, and UA. Differential pulse voltammetery (DPV) was used for the determination of AA, DA, and UA in their mixture. Under optimum conditions, the linear response ranges for the determination of AA, DA, and UA were 0.2–12.9 mM, 0.5–110 μM, and 10–1000 μM, with the detection limits (S/N = 3) of 10.09 μM, 0.29 μM and 1.24 μM, respectively. Furthermore, the modified electrode was investigated for real sample analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号