首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Improved detection of toxic chemicals using bioluminescent bacteria   总被引:1,自引:0,他引:1  
A sensitive, rapid and simple bioluminescent (BL) assay using bioluminescent bacteria to detect the toxic activity of several chemicals is described. This assay is based on the measurement of inhibition of light production of a bioluminescent bacterial strain, isolated from seawater, in the presence of different toxins like heavy metals, organic chemicals, such as benzene, toluene, ethylbenzene, xylene (BTEX) and a wide range of pesticides in environmental samples. The improvement with respect to other commercial and non-commercial bioluminescent assays consists of the possibility to work at room temperature without the need to thermostat, thus allowing the use of simpler and low cost instruments, or to improve the assay using a microplate format, which makes it possible to analyse several samples also continuously for several hours. Using lyophilised bacteria, the assay is performed in less than an hour, without any bacterial cultivation, which makes the test suitable for rapid and sensitive evaluation of chemical pollutants in environmental samples.  相似文献   

2.
Chen G  Lin Y  Wang J 《Talanta》2006,68(3):497-503
During the past decade, significant progress in the development of miniaturized microfluidic systems has occurred due to the numerous advantages of microchip analysis. This review focuses on recent advances and the key strategies in microchip capillary electrophoresis (CE) with electrochemical detection (ECD) for separating and detecting a variety of environmental pollutants. The subjects covered include the fabrication of microfluidic chips, ECD, typical applications of microchip CE with ECD in environmental analysis, and future prospects. It is expected that microchip CE-ECD will become a powerful tool in the environmental field and will lead to the creation of truly portable devices.  相似文献   

3.
The extractability of some typical environmental pollutants in ionic liquids (ILs) was screened by using a simple one-step liquid phase microextraction procedure. It was demonstrated that 1-alkyl-3-methylimidazolium hexafluorophosphate ([CnMIM][PF6], n = 4, 8), two typical ILs, could effectively extract a set of 45 typical environmental pollutants including BTEX (benzene, toluene, ethylbenzene, and xylene), polycyclic aromatic hydrocarbons, phthalates, phenols, aromatic amines, herbicides, organotin, and organomecury. Analytes in 10 mL sample solution held in a 15 mL vial were extracted by a 5 microL drop of ILs suspended on the needle of a high-performance liquid chromatography (HPLC) microsyringe; this was followed by HPLC, atomic absorption spectrometry, or cold-vapor atomic fluorescence spectrometry determination. The enrichment factors determined were in the range of 5-168 for 15 min extraction by [C4MIM][PF6] and 4-178 for 30 min extraction by [C8MIM][PF6], respectively, which indicates that ILs might be considered as potential environmentally benign alternative recyclable solvents for the enrichment of environmental pollutants.  相似文献   

4.
An integrated gas chromatography/Fourier transform infrared spectrometry (GC/FT-IR) system developed for the analysis of environmental pollutants is described. The versatility of the system allows the utilization of many different techniques of sample introduction and manipulation during analysis. The sample can be introduced by direct injection or thermal desorption from an adsorbent cartridge, and can then be separated on one of two capillary columns and detected by FT-IR or an FID. Cold traps and collection cartridges incorporated in the system permit recovery and additional fractionation of samples. Recovered sample and sample fractions can then be re-analyzed by GC/FT-IR or subsequently analyzed by GC/MS or other methods.  相似文献   

5.
The field of environmental forensics emerged in the 1980s as a consequence of legislative frameworks enacted to enable parties, either states or individuals, to seek compensation with regard to contamination or injury due to damage to the environment. This legal environment requires stringent record keeping and defendable data therefore analysis can sometimes be confined to data to be obtained from certified laboratories using a standard accredited analytical method. Many of these methods were developed to target specific compounds for risk assessment purposes and not for environmental forensics applications such as source identification or age dating which often require larger data sets. The determination of persistent organic pollutants (POPs) for environmental forensic applications requires methods that are selective but also cover a wide range of target analytes which can be identified and quantified without bias. POPs are used in a wide variety of applications such as flame retardants, fire suppressants, heat transfer agents, surfactants and pesticides mainly because of their chemical inertness and stability. They also include compounds such as dioxins that can be unintentionally produced from industrial activities. POPs are persistent in the environment, bioaccumulative and/or toxic and therefore require analytical methods that are sensitive enough to meet the low detection limits needed for the protection of the environment and human health. A variety of techniques, procedures and instruments can be used which are well suited for different scenarios. Optimised methods are important to ensure that analytes are quantitatively extracted, matrix coextractables and interferences are removed and instruments are used most effectively and efficiently. This can require deviation from standard methods which can open the data up to further scrutiny in the courtroom. However, when argued effectively and strict QA/QC procedures are followed the development and optimization of methods based on investigation specific scenarios has the potential to generate better quality and more useful data.  相似文献   

6.
Chiu KH  Yak HK  Wai CM  Lang Q 《Talanta》2005,65(1):149-154
Packed in a high-pressure vessel and under calculated conditions, dry ice can be used as a source of carbon dioxide for supercritical CO2 extraction or liquid CO2 of organic compounds from environmental samples. Coupled with a fluid modifier such as toluene, dry ice-originated supercritical CO2 (Sc CO2) achieves quantitative extraction of many volatile organic compounds (VOCs) and semivolatile organic compounds (SOCs) including polycyclic aromatic hydrocarbons (PAHs), n-alkanes, and polychlorinated biphenyls (PCBs) from solid matrices. Compared to contemporary manual or automated supercritical fluid extraction (SFE) technologies, this novel technique simplifies SFE to a minimum requirement by eliminating the need of a high-pressure pump and any electrical peripherals associated with it. This technique is highly suitable to analytical areas where sample preservation is essential but difficult in the sampling field, or where sample collection, sample preparation, and analysis are to be done in the field.  相似文献   

7.
Summary Some of the most commonly employed carbon blacks (Carbograph 1,2,4,5 from Lara and Carbopack X form Supelco), were evaluated by the BET surface characterization method for pore size distribution, porosity and specific surface. This information is often incomplete as furnished by manufacturers and is needed for a deeper understanding of carbon adsorption properties in chromatography. The data on surface characterization were obtained before and after graphitisation treatment (except for Carbopack X which could not be obtained in non-graphitized form). The nature of the active sites present on these carbons was investigated by BET analysis, atomic absorption and FT-IR. Dedicated to the memory of F. Bruner and G. Crescentini, pioneers in the study of graphitized carbon blacks for the sampling and analysis of environmental pollutants [1–4].  相似文献   

8.
Potentially toxic organic and inorganic compounds have been released into the environment by different sources. Due to this detrimental problem, the modern analytical chemistry has increasingly acted in the interface of knowledge in terms of developing methods which are robust, efficient, sensitive, inexpensive, and aim at meeting green chemistry principles. From an electroanalytical standpoint, the application of polysaccharides derived from natural sources in the development of chemically modified electrodes has increased in the last decades. Chitosan, cellulose and other polysaccharides have been widely used in the development of modified electrodes due to their high mechanical strength, relatively low cost, and green features. Several studies have reported in the past few years that chemically modified electrodes elaborated with these polysaccharides usually present superior analytical properties as compared to the conventional electrodes. This review describes the general aspects of these polysaccharides, extraction sources, characterization methods, derivatives and crosslinking processes as well as a comprehensive overview of their several applications in the development of new sensors applied to environmental samples.  相似文献   

9.
It is known that environmental pollution, which is the result of human-induced industrial, domestic, and agricultural practices, poses a threat to our planet. The increasing human population caused several problems such as water and air pollution, which have reached levels threatening human health. There are many different hazardous chemical and biological environmental pollutants in soil, air, and wastewater. It is extremely important to evaluate these health risks and detect these pollutants. The use of electrochemical methods for the detection of environmental pollutants comes to the forefront recently with advantages such as sensitivity, fast response, low cost, and practical use by miniaturization. The molecular imprinting technique is a popular method used for substance analysis by creating a cavity specific to the substance to be analyzed with the polymer used. The use of molecularly imprinted polymer in electrochemical methods and its modification with various nanomaterials bring advantages such as high selectivity, robustness, and sensitivity to electrochemical sensors. Here, the sensitive determination of environmental pollutants with different nanomaterial-modified molecularly imprinted polymer-based electrochemical sensors, the use of different polymerization techniques, and nano-sized modification agents in sensors are evaluated by reviewing recent studies in the literature.  相似文献   

10.
Environmental pollution and its drastic effects on human and animal health have urged governments to implement strict policies to minimize damage. The first step in applying such policies is to find reliable methods to detect pollution in various media, including water, food, soil, and air. In this regard, various approaches such as spectrophotometric, chromatographic, and electrochemical techniques have been proposed. To overcome the limitations associated with conventional analytical methods, microfluidic devices have emerged as sensitive technologies capable of generating high content information during the past few years. The passage of contaminant samples through the microfluidic channels provides essential details about the whole environment after detection by the detector. In the meantime, artificial intelligence is an ideal means to identify, classify, characterize, and even predict the data obtained from microfluidic systems. The development of microfluidic devices with integrated machine learning and artificial intelligence is promising for the development of next-generation monitoring systems. Combination of the two systems ensures time efficient setups with easy operation. This review article is dedicated to the recent developments in microfluidic chips coupled with artificial intelligence technology for the evolution of more convenient pollution monitoring systems.  相似文献   

11.
A novel method for the retention of arsenate [As(V)] combining time-controlled solid-phase extraction with living bacterial biomass is presented. As(V) retention was carried out by exposing the extractant, consisting of a living double-mutant of Corynebacterium glutamicum strain ArsC1-C2, to the sample for a retention time of 1-7 min, before the arsenic distribution equilibrium between the sample solution and the extractant was established. The amount of As(V) retained in the biomass was measured by inductively coupled plasma-mass spectrometry (ICP-MS) after the sample had been treated with nitric acid. A theoretical model of the retention process was developed to describe the experimental retention-time profiles obtained with the bacterial cells. This relationship provided a feasible quantification of the retention process before steady-state was reached, providing that the agitation conditions and the retention time had been controlled. An analytical procedure for the retention/quantification of As(V) was then developed; the detection limit was 0.1 ng As(V) mL−1 and the relative standard deviation 2.4-3.0%. The maximum effective retention capacity for As(V) was about 12.5 mg As (g biomass)−1. The developed procedure was applied to the determination of total arsenic in coal fly ash, using a sample that had undergone oxidative pre-treatment.  相似文献   

12.
Advances in passive sampling in environmental studies   总被引:2,自引:0,他引:2  
Passive sampling is based on the phenomenon of mass transport due to the difference between chemical potentials of analytes in a given environmental compartment and the collection medium inside a dosimeter. The subsequent laboratory procedure (i.e. extraction, identification and determination of analytes) is the same as in the case of classic sampling techniques.Passive sampling techniques are characterized by simplicity with regard to the dosimeter's construction as well as its maintenance. Therefore, they find ever increasing application in the field of environmental research and analytics. When choosing a passive sampling method, one should not forget that some passive samplers require the time-consuming calibration step before being used in the field.Novel solutions and modifications of existing sampler designs have been presented. Practical application of passive dosimetry in environmental analytics, including sampling of water, soil, air and other atypical media are discussed. Some aspects of calibration methods in passive dosimetry are also described. The latest trends in the application of passive sampling are highlighted.  相似文献   

13.
This review presents the strengths and weaknesses of monolithic materials for the enrichment of inorganic and organic contaminants in environmental waters. We describe the most common materials (silica, organic, and hybrid organic silica) and strategies for constructing monoliths in different moulds and shapes (tubes, cartridges, stir bars, fibers) published since 2015. The functionalization of the pore surfaces enhances their affinity towards different classes of pollutants. For instance, the incorporation of chelating groups enables the enrichment of potentially toxic metals and semi-metals in aquatic environments before the analyses by spectrometric techniques. Monolithic materials for extracting emerging pollutants, diverse classes of herbicides, and fungicides were proposed recently. Incorporation of carbon-based and magnetic nanoparticles, metal-organic frameworks, and ionic liquids enhanced their adsorption capacity by either increasing the surface area or providing multiple retention mechanisms. Monoliths with molecular recognition properties for highly selective extractions have been synthesized, including boronic functionalities and molecularly imprinted cavities. The final part describes the hybrid organic silica monoliths, emphasizing metal ions and speciation analysis hyphenated with ICP-MS. In the outlook section, we point to some fields we believe monoliths will benefit, such as their 3-D technologies preparation. We also pointed their potential applicability in portable chromatographic systems, restricted access materials, and enhanced use to preconcentrate viruses from aquatic environments.  相似文献   

14.
This review highlights the analytical chemistry, environmental occurrence, and environmental fate of individual stereoisomers of chiral emerging pollutants, which are modern current-use chemicals of growing environmental concern due to their presence in the environment and potential for deleterious effects. Comparatively little is known about individual stereoisomers of pollutants, which can have differential toxicological effects and can be tracers of biochemical weathering in the environment. Stereoisomers are resolved by gas chromatography (GC), high-performance liquid chromatography (HPLC), and capillary electrophoresis (CE). Separation techniques in environmental analysis are typically coupled to mass spectrometry (MS) and tandem mass spectrometry (MS/MS), as these provide the sensitivity and selectivity needed. The enantiomer composition of phenoxyalkanoic and acetamide herbicides, organophosphorus and pyrethroid pesticides, chiral polychlorinated biphenyl metabolites, synthetic musks, hexabromocyclododecane, and pharmaceuticals in the environment show species-dependent enantioselectivity from biotransformation and other biologically mediated processes affecting enantiomers differentially. These enantiomer compositions are useful in detecting biologically mediated environmental reactions, apportioning sources of pollutants, and gaining insight into the biochemical fate of chiral pollutants in the environment, which are needed for accurate risk assessment of such chemicals.  相似文献   

15.
This paper reports the preconcentration of some dissolved organic phosphorous and chlorinated acaricides in water by porous polyether based polyurethane foam. Preliminary screening tests on the retention of the tested compounds, i.e., dicofol and bromopropylate, by polyether foams indicated that a very high percent removal of the tested species was obtained. The retention rate was found fast and reaches equilibrium in a few minutes. The various parameters, e.g., pH, extraction media, shaking time, salt effect, temperature and sample volumes affecting the preconcentration of the tested species by the unloaded foam, trioctylamine and trimethylphosphate treated foam have been optimized via batch modes of separation. The unloaded foams were employed in column modes for the retention and recovery of the tested species. The sorption efficiency and recovery of the compounds by the unloaded foams column were found to be up to 97.5%. The height equivalent to a theoretical plate (HETP) obtained by the unloaded foam was found to be in the range 1.1-1.3 ± 0.2 mm. The sorption mechanism of the tested compounds by the foams was discussed.  相似文献   

16.
A toxicity biomonitoring system using freeze-dried recombinant bioluminescent bacteria was implemented to diagnose the biotreatment of 2,4,5-trichlorophenol and its degradation byproducts of using a cell-free culture broth of Phanerochaete chrysosporium. The cellular toxicity was measured by the bioluminescence of constitutive bioluminescent bacteria, such as Photobacterium phosphoreum and GC2, while information on the toxicity caused by unknown byproducts was obtained using the specific bioluminescent responses of stress-inducible bioluminescent bacteria, which included DPD2540 (membrane-damage sensitive), TV1061 (protein-damage sensitive), DPD2794 (DNA-damage sensitive), and DPD2511 (oxidative-damage sensitive) strains. An overall decrease in the cellular toxicity was observed as the treatment progressed, i.e. as 2,4,5-trichlorophenol disappeared. On the other hand, bioluminescent responses from DPD2511, DPD2540, and TV1061 increased as degradation progressed, most probably due to the formation of byproducts causing oxidative-, membrane-, and protein-damage. In conclusion, this toxicity biomonitoring method may be applied to evaluate the toxicities of degradation byproducts of the other environmental processes to provide more information about the mode of the byproducts’ toxicity.  相似文献   

17.
The rapidly growing existence of a number of contaminants (i.e. heavy metals, dye compounds, explosives and pesticides etc.) in environment is an alarming concern not only due to their harmful impacts for the environment bur also due to their potential high risk for human health. Thus, the careful and sensitive detection of these environmental contaminants is ver crucial. Electrochemical sensors combined with molecularly imprinted polymers (MIPs) become an attractive area for environmental monitoring. Benefiting from their great features such as high chemical and physical stability, cheap preparation process, excellent selectivity, sensitivity and fast response towards the target compound/s.This review paper aims to present and highlight the latest progresses in the design and development of novel electrochemical sensor systems composed of MIPs and carbon paste electrodes (CPEs) for the sensitive detection of pollutants in environmental samples.  相似文献   

18.
A number of density functionals was utilized for the calculation of electron attachment free energy for nitrocompounds, quinones and azacyclic compounds. Different solvation models have been tested on the calculation of difference in free energies of solvation of oxidized and reduced forms of nitrocompounds in aqueous solution, quinones in acetonitrile, and azacyclic compounds in dimethylformamide. Gas‐phase free energies evaluated at the mPWB1K/tzvp level and solvation energies obtained using SMD model to compute solvation energies of neutral oxidized forms and PCM(Pauling) to compute solvation energies of anion‐radical reduced forms provide reasonable accuracy of the prediction of electron attachment free energy, difference in free solvation energies of oxidized and reduced forms, and as consequence yield reduction potentials in good agreement with experimental data (mean absolute deviation is 0.15 V). It was also found that SMD/M05‐2X/tzvp method provides reduction potentials with deviation of 0.12 V from the experimental values but in cases of nitrocompounds and quinones this accuracy is achieved due to the cancelation of errors. To predict reduction ability of naturally occurred iron containing species with respect to organic pollutants we exploited experimental data within the framework of Pourbaix (Eh ? pH) diagrams. We conclude that surface‐bound Fe(II) as well as certain forms of aqueous Fe(II)aq are capable of reducing a variety of nitroaromatic compounds, quinones and novel high energy materials under basic conditions (pH > 8). At the same time, zero‐valent iron is expected to be active under neutral and acidic conditions. © 2011 Wiley Periodicals, Inc. J Comput Chem, 2011  相似文献   

19.
Atmospheric pressure chemical ionization (APCI) was primarily applied as the ion source for liquid chromatography-mass spectrometry (LC–MS). While APCI started to be used in gas chromatography-mass spectrometry (GC–MS) in 1970s, GC-APCI-MS was not widely used until recently. As a soft ionization technique, APCI provides highly diagnostic molecular ions, which is favored for the wide-scope screening. With the capability of tandem mass spectrometry (MS/MS), GC-APCI-MS methods with high sensitivity and selectivity have been developed and applied in the analysis of persistent organic pollutants (POPs) in environment and biological samples at trace levels. The present review introduces the history of the APCI source, with emphasis on mechanisms of ionization processes under the positive and negative ionization modes. Comparison between GC-APCI-MS and GC–MS with traditional electron ionization (EI) and chemical ionization (CI) are provided and discussed for selectivity, sensitivity and stability for the analyses of POPs. Previous studies found that the GC-APCI-MS methods provided limits of detection (LODs) around 10–100 times lower than other methods. An overview of GC-APCI-MS applications is given with the discussions on the advantages and drawbacks of various analytical methods applied for the analyses of POPs.  相似文献   

20.
Online preconcentration using electrokinetic supercharging (EKS) was proposed to enhance the sensitivity of separation for endocrine disrupting chemical (methylparaben (MP)) and phenolic pollutants (2‐nitrophenol (NP) and 4‐chlorophenol (CP)) in water sample. Important EKS and separation conditions such as the concentration of BGE; the choice of terminating electrolyte (TE); and the injection time of leading electrolyte (LE), sample, and TE were optimized. The optimum EKS‐CE conditions were as follows: BGE comprising of 12 mM sodium tetraborate pH 10.1, 100 mM sodium chloride as LE hydrodynamically injected at 50 mbar for 30 s, electrokinetic injection (EKI) of sample at –3 kV for 200 s, and 100 mM CHES as TE hydrodynamically injected at 50 mbar for 40 s. The separation was conducted at negative polarity mode and UV detection at 214 nm. Under these conditions, the sensitivity of analytes was enhanced from 100‐ to 737‐fold as compared to normal CZE with hydrodynamic injection, giving LOD of 4.89, 5.29, and 53 μg/L for MP, NP and CP, respectively. The LODs were adequate for the analysis of NP and CP in environmental water sample having concentration at or lower than their maximum admissible concentration limit (240 and 2000 μg/L for NP and CP). The LOD of MP can be suitable for the analysis of MP exists at mid‐microgram per liter level, even though the LOD was slightly higher than the concentration usually found in water samples (from ng/L to 1 μg/L). The method repeatabilities (%RSD) were in the range of 1.07–2.39% (migration time) and 8.28–14.0% (peak area).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号