1.
Means to allow for the application of a dipolar DC pulse to the end-cap electrodes of a three-dimensional (3-D) quadrupole ion trap for as short as a millisecond to as long as hundreds of milliseconds are described. The implementation of dipolar DC does not compromise the ability to apply AC waveforms to the end-cap electrodes at other times in the experiment. Dipolar DC provides a nonresonant means for ion acceleration by displacing ions from the center of the ion trap where they experience stronger rf electric fields, which increases the extent of micro-motion. The evolution of the product ion spectrum to higher generation products with time, as shown using protonated leucine enkephalin as a model protonated peptide, illustrates the broad-band nature of the activation. Dipolar DC activation is also shown to be effective as an ion heating approach in mimicking high amplitude short time excitation (HASTE)/pulsed Q dissociation (PQD) resonance excitation experiments that are intended to enhance the likelihood for observing low m/z products in ion trap tandem mass spectrometry.  相似文献   

2.
A two-dimensional quadrupole ion trap mass spectrometer   总被引:8,自引:0,他引:8  
The use of a linear or two-dimensional (2-D) quadrupole ion trap as a high performance mass spectrometer is demonstrated. Mass analysis is performed by ejecting ions out a slot in one of the rods using the mass selective instability mode of operation. Resonance ejection and excitation are utilized to enhance mass analysis and to allow isolation and activation of ions for MS(n) capability. Improved trapping efficiency and increased ion capacity are observed relative to a three-dimensional (3-D) ion trap with similar mass range. Mass resolution comparable to 3-D traps is readily achieved, including high resolution at slower scan rates, although adequate mechanical tolerance of the trap structure is a requirement. Additional advantages of 2-D over 3-D ion traps are also discussed and demonstrated.  相似文献   

3.
In a digital ion trap (DIT), the quadrupole trapping and excitation waveforms are generated by the rapid switching between discrete d.c. voltage levels. As the timing of the switch can be controlled precisely by digital circuitry, the approach provides an opportunity to generate mass spectra by means of a frequency scan in contrast to the conventional voltage scan, thus providing a wider mass range of analysis. An instrument has been constructed which employs a 'non-stretched' ion trap and the field fault around the aperture of the end-cap electrode can be corrected electronically using a field-adjusting electrode. The ion trap was coupled with electrospray ionization (ESI) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) sources to demonstrate the capability of the digital method. AP-MALDI mass spectra of singly charged ions with mass-to-charge ratios upto 17 000 Th were generated using a trapping voltage of only 1000 V. Forward and reverse mass scans at resolutions up to 19 000 and precursor ion isolation at resolutions up to 3500 with subsequent tandem mass spectrometric analysis were demonstrated. The method of generating the digital waveforms and period scan is described. Discussion of the issues of mass range, scan speed, ion trapping efficiency and collision-induced dissociation efficiency are also provided.  相似文献   

4.
The mass-selective manipulation of ions at elevated pressure, including mass analysis, ion isolation, or excitation, is of great interest for the development of mass spectrometry instrumentation, particularly for systems in which ion traps are employed as mass analyzers or storage devices. While experimental exploration of high-pressure mass analysis is limited by various difficulties, such as ion detection or electrical discharge at high-pressure, theoretical methods have been developed in this work to study ion/neutral collision effects within quadrupole ion traps and to explore their performance at pressures up to 1 Torr. Ion trapping, isolation, excitation, and resonance ejection were investigated over a wide pressure range. The theoretically calculated data were compared with available experimental data for pressures up to 50 mTorr, allowing the prediction of ion trap performance at pressures more than 10 times higher.  相似文献   

5.
Applying dipolar DC (DDC) to the end-cap electrodes of a 3-D ion trap operated with a bath gas at roughly 1 mTorr gives rise to ‘rf-heating’ and can result in collision-induced dissociation (CID). This approach to ion trap CID differs from the conventional single-frequency resonance excitation approach in that it does not rely on tuning a supplementary frequency to coincide with the fundamental secular frequeny of the precursor ion of interest. Simulations using the program ITSIM 5.0 indicate that application of DDC physically displaces ions solely in the axial (inter end-cap) dimension whereupon ion acceleration occurs via power absorption from the drive rf. Experimental data shows that the degree of rf-heating in a stretched 3-D ion trap is not dependent solely on the ratio of the dipolar DC voltage/radio frequency (rf) amplitude, as a model based on a pure quadrupole field suggests. Rather, ion temperatures are shown to increase as the absolute values of the dipolar DC and rf amplitude both decrease. Simulations indicate that the presence of higher order multi-pole fields underlies this unexpected behavior. These findings have important implications for the use of DDC as a broad-band activation approach in multi-pole traps.  相似文献   

6.
A simulation study is described of the behaviour of ions confined in a quadrupole ion trap during each of two separate operations of a tandem mass spectrometric experiment. The two operations are those of mass-selective ion isolation and mass-selective resonance excitation to the point of ion ejection from the ion trap. The method of mass-selective ion isolation simulated is that of consecutive ion isolation. Simulation data indicate that the collisional history of the ions prior to the isolation process can greatly influence the degree to which ions survive this process. Simulation data for mass-selective resonance ejection are compared with experimental data obtained with a Finnigan-MAT ion trap mass spectrometer. In each operation, the facility with which ions absorb energy from the field within the ion trap, whether this field is derived from the R.F. drive potential or a supplementary potential, can determine the extent to which ions are retained within the ion trap during the two mass-selective operations described.  相似文献   

7.
A mesh-electrode linear ion trap (ME-LIT) mass analyzer was developed and its performance was primarily characterized. In conventional linear ion trap mass analyzers, the trapped ions are mass-selected and then ejected in a radial direction by a slot on a trap electrode. The presence of slots can strongly affect the electric field distribution in the ion trapping region and distort the mass analysis performance. To compensate for detrimental electric field effects, the slot is usually designed and fabricated to be as small as possible, and also has very high mechanical accuracy and symmetry. A ME-LIT with several mesh electrodes was built to compensate for the effects caused by slots. Each mesh electrode was fabricated from a plate electrode with a relatively large slot and the slot was covered with a conductive mesh. Our preliminary experimental results show that the ME-LIT could considerably diminish the detrimental electric field effects caused by slots, and increase the mass resolving power and ion detection efficiency. Even with 4-mm-wide slots, a mass resolution in excess of 600 was obtained using the ME-LIT. Mass resolution could be remarkably improved using mesh electrodes in ion traps with asymmetric electrodes. The stability diagram of the ME-LIT was mapped, and highly efficient tandem mass spectrometry was demonstrated. The ME-LIT was qualified as a LIT mass analyzer. The ME-LIT can improve the mass resolution and decrease the requirements of mechanical accuracy and symmetry of slots, so it shows potential for a wide range of practical uses.
Figure
?  相似文献   

8.
A novel linear ion trap mass analyzer was developed using just four elongated planar electrodes, mounted in parallel, and employing an RF potential for ion trapping in the radial and axial directions. Mass analysis was achieved using the mass-selective instability scan with ion ejection in the radial direction. The performance of this new device was characterized in comparison with the 6-electrode rectilinear ion trap (RIT) from which it is derived. The 4-electrode trap gives optimum performance in an asymmetric geometry, just like the original optimized 6-electrode RIT. The strong RF fringing fields at the ends of the RF rods account for axial ion trapping without use of extra electrodes or an axial DC voltage. Field calculations and simulations have been carried out to study the trapping potential inside RITs with various configurations. Demonstrated capabilities include analysis of externally injected ions with mass resolution in excess of 1000 and a mass/charge range of 650 Th as well as tandem mass spectrometry capabilities. The geometric simplicity and performance characteristics of the 4-electrode RIT make it particularly attractive in the development of next generation miniaturized mass spectrometers.  相似文献   

9.
An open-ended cylindrical cell with a single annular trap electrode located at the center of the excitation and detection region is demonstrated for Fourier transform ion cyclotron resonance mass spectrometry. A trapping well is created by applying a static potential to the trap electrode of polarity opposite the charge of the ion to be trapped, after which conventional dipolar excitation and detection are performed. The annular trap electrode is axially narrow to allow the creation of a potential well without excessively shielding excitation and detection. Trapping is limited to the region of homogeneous excitation at the cell centerline without the use of capacitive coupling. Perfluorotributylamine excitation profiles demonstrate negligible axial ejection throughout the entire excitation voltage range even at an effective centerline potential of only ?0.009 V. High mass resolving power in the single-trap electrode cell is demonstrated by achievement of mass resolving power of 1.45 × 106 for benzene during an experiment in which ions created in a high pressure source cubic cell are transferred to the low pressure analyzer single-trap electrode cell for detection. Such high performance is attributed to the negligible radius dependent radial electric field for ions cooled to the center of the potential well and accelerated to less than 60% of the cell radius. An important distinction of the single-trap electrode geometry from all previous open and closed cell arrangements is exhibition of combined gated and accumulated trapping. Because there is no potential barrier, all ions penetrate into the trapping region regardless of their translational energy as in gated trapping, but additional ions may accumulate over time, as in accumulated trapping. Ions of low translational kinetic energy are demonstrated to be preferentially trapped in the single-trap electrode cell. In a further demonstration of the minimal radial electric field of the single-trap electrode cell, positive voltages can be applied to the annular trap electrode as well as the source cell trap electrode to achieve highly efficient transfer of ions between cells.  相似文献   

10.
印刷线路板分压离子阱的离子单向出射性能研究   总被引:3,自引:0,他引:3  
印刷线路板(Printed-Circuit-Board,PCB)分压离子阱是一种新型质量分析器,其突出优点在于内部电场可通过调节射频分压比进行优化.本实验在PCB分压离子阱离子出射方向的两组离散电极上配置了非对称的射频分压,以引入奇次阶场成分,使得射频电场的场中心(即离子运动中心)发生偏移,从而实现离子单向出射.通过数值计算软件SIMION和AXSIM分析了射频分压比差值与其内部电场分布的关系,并模拟离子运动轨迹,得到离子出射情况和模拟质谱峰.模拟结果表明,当两组离散电极的射频分压比差值为20%时,在合适的AC频率条件下,对于m/z=609 Th的离子,PCB分压离子阱的离子单向出射率可达90%以上,且质量分辨率大于2500.本研究可使PCB分压离子阱在基本不损失质量分辨率和使用单检测器模式下,大幅提高离子检测效率,因而在小型化质谱仪应用中具有显著优势.  相似文献   

11.
Using an axial focusing miniature linear ion trap with tubular end cap lenses (MLIT) we have investigated spatial focusing on ion ejection using low kinetic energy pulsed extraction methods. Ion packet widths focused to ca. 1 mm (in both the radial and axial planes) are produced following collisional cooling with helium buffer gas in an MLIT. Small axial and radial packet widths as well as application of DC extraction voltages allow different ion focusing techniques to be used on batch ion extraction. In particular, controlling the position of the space focus plane (commonly used in time-of-flight mass spectrometry) following low kinetic energy ( approximately 10 eV) ion ejection from an MLIT through the application of DC extraction voltages is illustrated. Prior to simultaneous ion ejection, induced axial ion oscillation through a change in the DC potential well shape is also shown to be useful for separating and controlling different mass/charge ion packet spatial distributions in the region of an orthogonal time-of-flight (o-TOF) push pulse.  相似文献   

12.
The use of a Q-q-Q(linear ion trap) instrument to obtain product ion spectra is described. The instrument is based on the ion path of a triple quadrupole mass spectrometer with Q3 operable as either a conventional RF/DC quadrupole mass filter or a linear ion trap mass spectrometer with axial ion ejection. This unique ion optical arrangement allows de-coupling of precursor ion isolation and fragmentation from the ion trap itself. The result is a high sensitivity tandem mass spectrometer with triple quadrupole fragmentation patterns and no inherent low mass cut-off. The use of the entrance RF-only section of the instrument as accumulation ion trap while the linear ion trap mass spectrometer is scanning enhances duty cycles and results in increased sensitivities by as much as a factor of 20. The instrument is also capable of all of the triple quadrupole scans including multiple-reaction monitoring (MRM) as well as precursor and constant neutral loss scanning. The high product ion scanning sensitivity allows the recording of useful product ion spectra near the MRM limit of quantitation.  相似文献   

13.
Some ions exhibit "ion fragility" in quadrupole ion trap mass spectrometry (QIT-MS) during mass analysis with resonance ejection. In many cases, different ions generated from the same compound exhibit different degrees of ion fragility, with some ions (e.g., the [M+H](+) ion) stable and other ions (e.g., the [M+Na](+) ion) fragile. The ion fragility for quadrupole ion trap (QIT) mass spectrometry (MS) for protonated and sodiated ions of three phospholipids, 1,2-dipalmitoyl-sn-glycero-3-phosphocholine, PC (16:0/16:0), 1,2-dipalmitoyl-sn-glycero-3-phophoethanolamine, PE (16:0/16:0), and N-palmitoyl-D-erythro-sphingosylphosphorylcholine, SM (d18:1/16:0), was determined using three previously developed experiments: 1) the peak width using a slow scan speed, 2) the width of the isolation window for efficient isolation, and 3) the energy required for collision-induced dissociation. In addition, ion fragility studies were designed and performed to explore a correlation between ion fragility in QIT mass analysis and ion fragility during transport between the ion source and the ion trap. These experiments were: 1) evaluating the amount of thermal-induced dissociation as a function of heated capillary temperature, and 2) determining the extent of fragmentation occurring with increasing tube lens voltage. All phospholipid species studied exhibited greater ion fragility as protonated species in ion trap mass analysis than as sodiated species. In addition, the protonated species of both SM (d18:0/16:0) and PC (16:0/16:0) exhibited greater tendencies to fragment at higher heated capillary temperatures and high tube lens voltages, whereas the PE (16:0/16:0) ions did not appear to exhibit fragility during ion transport.  相似文献   

14.
The design of a novel multipass optical arrangement for use with infrared multiple photon dissociation (IRMPD) in the quadrupole ion trap is presented. This design circumvents previous problems of limited IR laser power, small IR absorption cross sections for many molecules, and the limited ion statistics of trapping and detection of ions for IRMPD in the quadrupole ion trap. In contrast to previous designs that utilized the quadrupole ion store, the quadrupole ion trap was operated in the mass selective instability mode with concurrent resonance ejection. The instrumental design consisted of a modified ring electrode with three spherical concave mirrors mounted on the inner surface of the ring. This modified design allowed for eight laser passes across the radial plane of the ring electrode. IRMPD of protonated bis(2-methoxyethyl)ether (diglyme) was used to characterize the performance of the multipass ring electrode. Two consecutive reactions for the IRMPD of protonated diglyme were observed with a lower energy channel predominant at less than 0.6 J (irradiation times from 1 to 30 ms) and a second channel predominant at energies greater than 0.6 J (irradiation times > 30 ms). Other studies presented include a discussion of the dissociation kinetics of protonated diglyme, the use of a pulsed valve for increased trapping efficiency of parent ion populations, and the effects of laser wavelength and of ion residence time in the radial plane of the ring electrode on photodissociation efficiency.  相似文献   

15.
The discontinuous atmospheric pressure interface (DAPI) has been developed to allow a direct transfer of ions from atmosphere into an ion trap mass spectrometer with minimum pumping capability. Air is introduced into the trap with ions and used as a buffer gas for the ion trap operation. In this study, a method of introducing helium as a second buffer gas was developed for a miniature mass spectrometer using a dual DAPI configuration. The buffer gas effects on the performance of a linear ion trap (LIT) with hyperbolic electrodes were characterized for ion isolation, fragmentation and a mass-selective instability scan. Significant improvement was obtained with helium for resolutions of mass analysis and ion isolation, while moderate advantage was gained with air for collision-induced dissociation. The buffer gas can be switched between air and helium for different steps within a single scan, which allows further optimization of the instrument performance for tandem mass spectrometry.  相似文献   

16.
It is well known that superimposition of some positive octopole field will benefit the performance of ion trap mass analyzer. In the radial‐ejection linear ion trap (LIT), adding some octopole field component to the main quadrupole field is usually accomplished by stretching the ejection rod pair. In this study, the effect of octopole potential and some other higher order potential on the performance of LIT mass analyzer is investigated. A simple and effective method, which is to add some octopole component by building a LIT with a pair of rectangular electrodes and a pair of semi‐circular electrodes, is reported. Its properties were studied by numerical simulations and experiments. The results showed that a certain amount of positive octopole component could be produced by simply adjusting the position and width of the rectangular electrodes. A resolution of over 1200 at m/z 609 (~1600 Da/s) was observed in this type of LIT. They also performed tandem mass spectrometry well. The device with optimum geometry for ion ejection from rectangular electrodes provided comparable performance to that for ion ejection from semi‐circular electrodes. This type of LIT design is easy for fabrication and assembly. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
P W Crozier  J B Plomley  L Matchuk 《The Analyst》2001,126(11):1974-1979
Ontario Provincial Water Quality Objectives for polycyclic aromatic hydrocarbons (PAHs) in surface waters require low parts per trillion (ng L(-1))/high parts per quadrillion (pg L(-1)) detection limits. To meet these monitoring requirements, a solid phase extraction-gas chromatography-ion trap mass spectrometry (SPE-GC-ITMS) method was developed. Seventeen priority PAHs commonly monitored in surface and drinking waters were examined using an external ionization ion trap mass spectrometer operated in selected ion monitoring (SIM) mode. Under 70 eV electron ionization (El) conditions, both the quantitative [M]+* ion and confirmatory [M - 2H]+* ion were formed in classical abundance ratios. Each of these ion species was isolated in the ion trap using a specific scan function. However, to overcome poor levels of confirmatory ion abundance which otherwise restrict PAH method detection limits (MDLs), the abundance of [M - 2H]+* ions was augmented during isolation by causing the dissociation of [M]+* with the broad-band waveform used for high mass ion ejection. Augmenting the [M - 2H]+* signal intensity facilitated the achievement of MDLs of approximately 1 ng L(-1). PAHs in surface water samples that were not detected by current Ontario Ministry of the Environment high-performance liquid chromatography (HPLC)-fluorescence and GC-single-stage quadrupole mass spectrometry methods were detected and quantified using the ion trap mass spectrometry SIM method. The data produced by all three methods on natural water samples fortified at sub-parts per billion (ppb) levels were comparable. When applied to Standards Council of Canada/Canadian Association for Environmental Analytical Laboratories (SCC/CAEAL, www.CAEAL.ca) accreditation audit samples, the SPE-GC-ITMS method results met all performance evaluation criteria.  相似文献   

18.
Suspended trapping is used to eject electrons in negative-ion Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometric experiments. In contrast to electron ejection by resonant excitation of the trapping motion, suspended trapping involves allowing the electrons to escape along the z-axis (perpendicular to the trap plates) while the trapping potential is briefly removed. The duration of this event is sufficiently short (~10 μs) so that ion losses are negligible; the overall effect is that of a ‘high-pass mass filter’. Suspended trapping is simpler to implement and more generally applicable to various cell geometries than resonant electron ejection. The effectiveness of the suspended trapping technique is not compromised by the anharmonicity of the potential well in ‘elongated’ ICR traps, but depends simply on the time it takes the electrons to escape the cell. Finally, a small, positive offset potential (~+0.25 V) applied to the trap plates during the suspended trapping event increases the efficiency of the ejection.  相似文献   

19.
An ion guide, consisting of three rods carrying three alternating current (AC) voltages symmetrically delayed, called a tripole, was used as a linear ion trap (LIT) and studied by computer simulations. Radial containment of ions was also demonstrated with the pseudopotential which was calculated by approximating the tripole electric potential to the multipoles expansion. This work found a new analyte concentrator, which performs effective ion ejection, and is suitable for use with time-of-flight mass spectrometry. The efficiency of the overall process from the trapping until the ejection was higher than 90%, although some degree of ion spatial and kinetic energy spread which can be corrected with a reflectron was obtained. The reason for the ejection of this tripole linear ion trap (tLIT) lies in the high space available between the rods. The ejection is optimized with the application of focusing voltages, especially suitable for a tripole symmetry (one electrode has a pulse offset voltage and the other two have a fraction of that pulse). The beam is finally well parallelized with a rectangular Einzel lens.  相似文献   

20.
We have developed a new mass‐selective axial ejection method from a linear ion trap (LIT). In this method, a set consisting of a trap wire lens and an extraction wire lens positioned orthogonally to each other was placed between quadrupole rods. The trap wire lens confines the ions inside the trap, and the extraction wire axially extracts ions from the trap. Ions introduced into the LIT are trapped between the inlet lens and the trap wire lens. In addition to the wire lenses, a set of excitation lenses, which are aligned orthogonally to the trap wire lens, are inserted between rods. The ions are resonantly excited in the direction perpendicular to the trap wire lens by applying a supplemental alternating current (AC) to the excitation lenses. Excited ions with a large motion pass over the trap wire lens, while unexcited ions remain trapped inside. Ions that have passed over the trap wire lens are then extracted by the extraction wire lens. The characteristics of the mass‐selective ejection with a direct current (DC) extraction field were investigated by both simulation and experiment. A mass resolving power of m/Δm = 1300 was achieved at a scan rate of 500 Th/s. The dependence of the ejection efficiency on trap wire lens bias was measured, and an ejection efficiency of 20% at a scan rate of 500 Th/s was achieved by optimizing the DC bias on the trap wire lens. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   