首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Capillary electrophoresis-mass spectrometry (CE-MS) is a powerful separation and analytical technique in the field of analytical chemistry. This review provides an update of instrumentation developments in the methodology of CE-MS systems. A selection of relevant articles covers the literatures published from Jan. 2013 to Feb. 2017. Special attentions were paid to the sample injection and ionization processes. Applications of these CE-MS systems were also introduced through representative examples. General conclusions and perspectives were given at the last.  相似文献   

2.
Nonaqueous background electrolytes broaden the application of capillary electrophoresis displaying altered separation selectivity and interactions between analytes and buffer additives compared to aqueous background electrolytes. In addition, nonaqueous capillary electrophoresis (NACE) appears to be ideally suited for online coupling with mass spectrometry due to the high volatility and low surface tension of many organic solvents. Despite these advantages and an increasing use of nonaqueous background electrolytes in CE, coupling of NACE to mass spectrometry has not yet been applied very often to date. The present review summarizes the applications of online NACE-MS with regard to the analysis of drugs, stereoisomers, peptides, alkaloids, polymers and others. A brief discussion of solvent effects in NACE and pH of nonaqueous background electrolyte systems is also presented.  相似文献   

3.
CE-MS has evolved into a strong alternative to LC-MS. Most of CE-MS applications deal with characterization and identification. However, quantitative aspects have gained importance in, e.g., pharmaceutical and biotechnological applications. Here we summarize and evaluate various methodological aspects in order to achieve sensitive and reproducible results. Similar to LC-MS, aspects of matrix influence on the electrospray process need to be carefully addressed when quantitative results are intended by CE-MS. Due to a more complicated coupling special emphasis needs to be put on the CE-MS interface. Generally linearity over more than three orders of magnitude can be achieved by CE-ESI-MS. Furthermore, a literature survey has been performed in order to give an overview over quantitative measurements performed by CE-MS. The precision can be doubled when changing from a structural related to an isotopically labeled internal standard. Thus a level of precision better than 5% RSD can be achieved.  相似文献   

4.
5.
毛细管电泳-质谱联用技术的新进展   总被引:1,自引:0,他引:1  
周志贵  李珉  白玉  刘虎威 《色谱》2009,27(5):598-608
毛细管电泳-质谱(CE-MS)联用技术综合了CE的高效分离能力、广泛的样品适应性和MS的高灵敏度、可提供结构信息等优势,已发展成为一种重要的分离分析手段。本文对近几年来CE-MS联用接口技术的发展作一简单介绍,并对CE-MS在生命分析、食品药品分析等领域的一些应用进展予以综述。  相似文献   

6.
The utility of the combination of separations techniques, such as liquid chromatography and capillary zone electrophoresis, with mass spectrometry in applications involving protein analysis is discussed. The use of continuous-flow fast atom bombardment and electrospray ionization mass spectrometry is compared for the analysis of tryptic digests. For liquid chromatography, both microbore and slurry-packed capillary bore columns were used to separate peptides from proteolytic digests.  相似文献   

7.
Metabolome analysis by capillary electrophoresis-mass spectrometry   总被引:1,自引:0,他引:1  
Monton MR  Soga T 《Journal of chromatography. A》2007,1168(1-2):237-46; discussion 236
Capillary electrophoresis (CE)-mass spectrometry (MS), as an analytical platform, has made significant contributions in advancing metabolomics research, if still limited up to this time. This review, covering reports published between 1998 and 2006, describes how CE-MS has been used thus far in this field, with the majority of the works dealing with targeted metabolite analyses and only a small fraction using it in the comprehensive context. It also discusses how some of the key features of CE-MS were exploited in selected metabolomic applications.  相似文献   

8.
Shamsi SA 《Electrophoresis》2002,23(22-23):4036-4051
A review is presented to highlight several approaches for coupling capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS) for analysis of chiral compounds. A short discussion of commercially available CE-MS instruments and interface design is followed by a detail review on various modes of chiral CE-MS. In general, for each CE-MS mode, the capabilities, applications and limitations for chiral analysis have been pointed out. The first mode, chiral capillary zone electrophoresis-mass spectrometry (CZE-MS) in which neutral derivatized cyclodextrins (CDs) are used is possible using either column coupling with voltage switching or a partial-filling technique (PFT). However, some applications of direct coupling of CZE-MS mode are also reported. The second mode is a chiral electrokinetic chromatography-mass spectrometry (EKC-MS) in which a charged chiral selector such as a sulfated beta-CD or a vancomycin could be conveniently employed. This is because these chiral selectors have a significantly higher countercurrent electrophoretic mobility which prevents the entrance of these selectors into the mass spectrometer. The combination of counter-migration and PFT demonstrates that this synergism could be successfully applied to chiral analysis of a broader range of compounds. It is well-known that the on-line coupling of micellar electrokinetic chromatography to mass spectrometry (MEKC-MS) is problematic because the high surface activity and nonvolatile nature of conventional surfactant molecules lower the electrospray ionization efficiency. However, a recent report demonstrates that this hyphenation is now possible with the use of molecular micelles. Various MEKC-ESI-MS parameters that can be used to optimize both chiral resolution and ESI response are discussed. Finally, two recent examples that demonstrate the feasibility of using either open-tubular or packed chiral CEC with MS are reviewed. This survey will attempt to cover the state-of-the-art on various modes of CE-MS from 1998 up to 2002.  相似文献   

9.
10.
Sample preparation is a crucial part of chemical analysis and in most cases can become the bottleneck of the whole analytical process. Its adequacy is a key factor in determining the success of the analysis and, therefore, careful selection and optimization of the parameters controlling sample treatment should be carried out. This work revises the different strategies that have been developed for sample preparation prior to capillary electrophoresis-mass spectrometry (CE-MS). Namely the present work presents an exhaustive and critical revision of the different samples treatments used together with on-line CE-MS including works published from January 2000 to July 2006.  相似文献   

11.
Chao BF  Chen CJ  Li FA  Her GR 《Electrophoresis》2006,27(11):2083-2090
A sheathless interface has been developed for coupling CE with electrospray IT mass spectrometer. This interface utilized a pulsed ESI source. The use of a pulsed electrospray source allows the use of a sprayer with larger orifice, and thus alleviates the problem of column clogging during conductive coating and CE analysis. A pulsed ESI source operated at 20 Hz and 20% duty cycle was found to produce the optimal signals. For better signals, the maximum ion injection time in the IT mass spectrometer has to be set to a value close to the actual spraying time (10 ms). Using a sprayer with 50 microm od, more stable and enhanced signals were obtained in comparison with continuous CE-ESI-MS under the same flow rate (150 nL/min). The utility of this design is demonstrated with the analysis of synthetic drugs by CE-MS.  相似文献   

12.
Simó C  Rizzi A  Barbas C  Cifuentes A 《Electrophoresis》2005,26(7-8):1432-1441
In this work, the development of a new chiral capillary electrophoresis-mass spectrometry (CE-MS) method to separate D- and L-amino acids is shown. On-line coupling between CE and MS is established through an electrospray-coaxial sheath flow interface. Enantiomer separation is achieved by using a cheap, nonvolatile, chiral selector as beta-cyclodextrin in the background electrolyte (BGE) together with a physically coated capillary that is aimed to prevent contamination of the electrospray. The capillary coating is simple and easy to obtain as it only requires flushing of the capillary with a polymer aqueous solution for 3 min. Optimization of CE parameters (pH of BGE, type and concentration of chiral selector, and capillary inner diameter) and electrospray-MS parameters (nature and flow rate of the sheath liquid, nebulizer pressure) is carried out. Two different derivatization protocols of amino acids using dansyl chloride (DNS) and fluorescein isothiocyanate (FITC) are compared in terms of MS sensitivity and chiral resolution. Under optimum CE-MS conditions it is observed that the MS sensitivity obtained for FITC- and DNS-amino acids is similar (with limit of detection (LOD) in the microM range, corresponding to amounts injected in the fmol range) while chiral resolution is better for FITC-amino acids. The optimized method is demonstrated to provide the simultaneous analysis of 15 selected amino acids (i.e., FITC-D/L-Asp, -Glu, -Ser, -Asn, -Ala, -Pro, -Arg, and FITC-gamma-aminobutyric acid (GABA) in a single chiral CE-MS run, corresponding to the main amino acids that can be found in orange. Moreover, as a result of the high resolution achieved, it is possible to detect down to 2% of D-Asp in the presence of 98% of L-Asp. The good possibilities of chiral CE-MS in food analysis are corroborated through the detection of the main amino acids in a commercial orange juice (i.e., FITC-L-Asp, -Glu, -Ser, -Asn, -Pro, -Arg, and the nonchiral FITC-GABA) as well as the determination of the fraudulent addition of synthetic amino acids (containing D- and L-forms) to a fresh orange juice.  相似文献   

13.
An array detection system based on position- and time-resolved ion counting was evaluated for capillary electrophoresis-mass spectrometry using continuous-flow fast atom bombardment and a liquid-junction coupling. Peptides with molecular masses up to 3200 were measured. A 100-1000-fold improvement over conventional detection was demonstrated by applying the array detector in scanning and static modes. Absolute detection limits in the range 1-5 fmol are achievable.  相似文献   

14.
王芳  王松  丛海林  于冰 《色谱》2020,38(9):1013-1021
毛细管电泳-质谱(CE-MS)联用技术具有高灵敏度、高分析效率、低样品损耗等优点,在强极性和带电荷的物质分析中具有明显优势,已广泛应用于生命科学、医学、药学等多个领域。在过去的十几年,影响其应用的主要因素包括系统的稳定性、实验的可重复性、数据的准确性等。为解决现有问题,进一步拓展其应用,研究人员在技术设计和改进等方面做了大量工作。医学和分析化学领域的相关研究证明了CE-MS在代谢组学和蛋白质组学中的实用性。这篇文章综述了2015年以来,CE-MS在技术和应用方面的最新进展,为未来的技术发展及应用提供借鉴。为提高CE-MS的分析效率和数据可比性,该文对多个方面的研究进行了讨论,包括涂层与样品的相互作用、接口技术、运行参数和数据处理方法。文中关于复杂样品(组织、细胞、体液等)代谢组学/蛋白质组学的综述研究,使癌症病理分析、药物开发和疾病监测等分析数据更加可视化,为CE-MS临床分析应用提供借鉴。除了对CE-MS的最新发展进行综合评述外,还提出未来应加强3个方面的研究:(i)从样品前处理和分离技术方面优化分析方法;(ii)从毛细管涂层和接口技术方面调整分析技术;(iii)从临床研究和数据分析...  相似文献   

15.
16.
Propolis is a resinous hive product rich in antioxidant compounds. Capillary electrophoresis coupled to mass spectrometric detection can provide selective information about the analytes present in complex extracts of propolis and has turned out to be an attractive alternative to HPLC methods. Therefore, a CE-ESI-MS method has been developed for the analysis of antioxidant compounds obtained from propolis. For this purpose, different electrophoretic parameters such as the nature, pH, and concentration of the separation buffer, as well as electrospray parameters (dry gas temperature and flow, nebulising gas pressure, and make-up flow) have been carefully optimised. Different phenolic compounds (e.g. pinobanksin 3-acetate, naringenin, pinocembrin, chrysin, daidzein, quercetin 3',7-dimethyl ether, apigenin, and kaempferid) could be detected. To confirm the identity of the phenolic compounds in propolis extracts, accurate mass data of the molecular ions were obtained by TOF MS. Limits of detection ranging from 6 mg/100 g of raw propolis for chrysin to 58 mg/ 100 g of raw propolis for luteolin, were obtained.  相似文献   

17.
Mass spectrometry (MS) has become a key tool for the characterization of biologically relevant molecules in the last decade. Due to the complexity of most biological samples an upstream separation is essential. Capillary electrophoresis (CE) has gained much interest due to its high separation efficiency, speed, and often complementary selectivity to liquid chromatography. We describe the state-of-the-art of on-line CE-MS for the analysis of molecules of biological origin. The characterization of peptides, including the study of post-translational modifications, intact proteins, oligonucleotides, and related interaction studies are reviewed. Relevant publications are summarized in tables, including some important method parameters. Key applications are discussed with respect to the advantages and limitations of CE-MS. Coupling interfaces, preconcentration techniques, capillary coatings, and the different CE techniques, e.g., capillary zone electrophoresis, capillary isoelectric focusing, capillary gel electrophoresis, etc. are briefly discussed against the background of their bioanalytical applications.  相似文献   

18.
CE hyphenated to ESI-MS (CE-ESI-MS) is a well-established technique to analyze charged analytes in complex samples. Although various interfaces for CE-MS coupling are commercially available, the development of alternatives which combine sensitivity, simplicity, and robustness remains a topic of research. In this work, a nanoflow sheath liquid CE-MS interface with two movable capillaries inside a glass emitter is described. The setup enables a separation mode and a conditioning mode to guide the separation capillary effluent either into the electrospray or to the waste, respectively. This enables to exclude parts of the analysis from MS detection and unwanted matrix components reaching the mass spectrometer, comparable to divert valves in LC-MS coupling. Also, this function improves the overall robustness of the system by reduction of particles blocking the emitter. Preconditioning with electrospray interfering substances and even the application of coating materials for every analysis is enabled, even while the separation capillary is built into the interface with running electrospray. The functionality is demonstrated by analyses of heavy matrix bioreactor samples. Overall, this innovation offers a more convenient installation of the interface, improved handling with an extended lifetime of the emitter tips and additional functions compared to previous approaches, while keeping the higher sensitivity of nanoflow CE-MS-coupling.  相似文献   

19.
The effect of the electrospray ionization (ESI) needle voltage on the electroosmotic flow (EOF) in capillary electrophoresis (CE)-mass spectrometry (MS) was investigated. The radial electric field that penetrates across the CE capillary wall imposed by the ESI needle voltage modifies the typical EOF. This effect was investigated for buffers commonly used in CE-MS. Variations as high as ±30% were observed.  相似文献   

20.
To simplify capillary electrophoresis-mass spectrometry (CE-MS) operation, a background electrolyte (BGE) containing a polymer additive is introduced that allows the analysis of peptides and protein mixtures in underivatized fused-silica capillaries without any pretreatment, thereby increasing throughput. The most important characteristic of these polymer additives is that they do not significantly suppress the signals of the proteins and peptides under electrospray ionization, thereby allowing them to be used as an additive to common BGEs that are used for CE-MS analysis of peptide and protein mixtures. In addition, because the fused-silica capillary inner wall is continuously coated with the polymer additive, migration irreproducibility, due to the degradation of the capillary inner wall coating, under CE-MS is minimized. High sensitivity of detection, migration reproducibility, and ease of fabrication allow CE-MS analyses that require long analysis time, such as (CE-MS/MS)n, to be performed with ease. The utility of this background electrolyte has been demonstrated for the analysis of complex protein digests and intact proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号