首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A novel, sensitive and specific method for the quantification of alpha-tocopherol in two infant foods (milk and cereals) using liquid chromatography on-line with positive atmospheric pressure chemical ionisation mass spectrometry detection (LC/APCI-MS) has been developed. The samples were first saponified in order to eliminate fats and to transform tocopherol esters into free tocopherol, followed up by a liquid-liquid extraction of the analyte in petroleum benzine/diisopropyl ether (75:25, v/v) prior to injection onto the LC system. For the quantification, deuterium-labelled tocopherol was used as internal standard and the samples were monitored in selected ion monitoring (SIM) mode. Calibration curves between 1-40 microg/mL of alpha-tocopherol showed a good linear correlation (r(2) = 0.99994), and the detection limit was determined to be 2.5 ng/mL. The within-day and between-day precision were determined for several dietetic infant formulae and certified reference samples, and found to be below 3.5%. The accuracy determined on a Nestlé reference sample (milk powder) was calculated to be 115.2 +/- 1.2%, which confirms the robustness of the proposed method. This study shows that single quadrupole LC/MS can be applied for the quantification of vitamins in food and the method offers better sensitivity and selectivity than traditional method such as LC-UV. This would simplify the preparation of the food samples and consequently enhance the vitamin analysis throughput in the food area.  相似文献   

2.
Bacteriohopanepolyols (BHPs) fragment via characteristic pathways during atmospheric pressure chemical ionisation liquid chromatography/ion trap mass spectrometry (APCI-LC/MS(n)). Comparison of the MS(2) spectra of bacteriohopane-32,33,34,35-tetrol (BHT) and 2 beta-methylbacteriohopane-32,33,34,35-tetrol has confirmed the previously proposed ring-C cleavage occurring between C-9 and 11 and C-8 and 14. This fragmentation, diagnostic of all hopanoids, also occurs in BHPs containing an amino group (-NH(2)) at C-35 although the higher relative stability of the ion limits this fragmentation to a minor process after protonation of the basic nitrogen function. Studies of a number of cell cultures including a prochlorophyte (Prochlorothrix hollandica) and a cyanobacterium (Chlorogloeopsis LA) demonstrate the power of this technique to detect composite BHPs with a complex biological functionality at C-35. We also report the first observation of intact pentafunctionalised bacteriohopanepolyols using this method.  相似文献   

3.
Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry (APCI-LC/MS) has been used for identification of the epimers of hydroxy, methoxy and methoxylactone allomers of chlorophyll a (13(2)-HO-chl a, 13(2)-MeO-chl a and 15(1)-MeO-lact-chl a), the hydroxy allomer of bacteriochlorophyll a (13(2)-HO-bchl a) and the hydroxy and methoxylactone allomers of bacterioviridin a (13(2)-HO-bvir a and 15(1)-MeO-lact-bvir a). The APCI mass spectra show that facile fragmentations involve the methoxyl or hydroxyl groups at the C-13(2) or C-15(1) chiral centres. Losses involving the C-13(2) or C-15(1) hydroxyl or methoxyl groups occur more easily from the S-epimer than from the R-epimer due to the greater relief of the steric strain associated with interaction with the bulky C-17 substituent. The differences in mass spectrometric fragmentation can be used as a diagnostic tool for the assignment of the stereochemical configuration at the C-13(2) or C-15(1) chiral centres.  相似文献   

4.
Humic substances were analysed by atmospheric pressure chemical ionisation (APCI) and electrospray ionisation (ESI) mass spectrometry in positive and negative modes. Using APCI the average m/z range of humic substances was reduced 5-fold compared to ESI. High-resolution time-of-flight mass spectrometry revealed the formation of multiply charged molecules in the ESI mode. Moreover, it was possible to obtain daughter ion mass spectra of humic substances by nanospray tandem mass spectrometry. The size-exclusion chromatography elution profile of humic substances was highly influenced by the pH of the analyte solution. By contrast, the pH had no significant influence on the observed mass spectra of humic substances.  相似文献   

5.
Differences in the ionisation efficiency of chlorophylls and their phaeophytin counterparts result in lower sensitivity for atmospheric pressure chemical ionisation mass spectrometric detection of the former. Improvement in the sensitivity of detection of chlorophyll of around an order of magnitude at a concentration of 1 x 10(-6)mol L(-1) has been achieved using post-column addition of methanoic acid during analysis by liquid chromatography/mass spectrometry (LC/MS). The method gives linear response and is a simple strategy to improve sensitivity both for LC/MS and LC/MS/MS without loss of information relating to the precise nature of the tetrapyrrole distributions. Detection levels achieved exceed those obtained by absorbance detection.  相似文献   

6.
Car lubricant additives are added to mineral or synthetic base stocks to improve viscosity and resistance to oxidation of the lubricant and to limit wear of engines. As they belong to various chemical classes and are added to a very complex medium, the base stock, their detailed chromatographic analysis is very difficult and time consuming. In a previous paper, it was demonstrated that supercritical fluid chromatography (SFC) allows the elution of common low-molecular-weight additives. Since their total resolution could not be achieved owing to the limited peak capacity of packed columns, the hyphenation of selective and informative detection methods such as atomic emission detection (AED) was required. Further to results obtained in SFC-AED, this work describes the hyphenation of SFC to atmospheric pressure chemical ionisation ion trap mass spectrometry (MS). SFC–MS hyphenation is detailed: temperature, flow rates of gas and mobile phase introduced in the source, position of the restrictor, ionisation additives and conditions of autotune are studied. Car lubricant monitoring requires negative and positive ionisation modes with or without the addition of ionisation auxiliary solvent according to the nature of additives. Moreover, when sensitivity is of major concern for a selected additive, the autotuning routine of the MS has to be performed in conditions as close as possible to analytical conditions, i.e. under subcritical conditions. Unambiguous identification and structure elucidation of several additives in formulated car lubricants are also presented.  相似文献   

7.
In-source 'on-the-fly' hydrogen/deuterium (H/D) exchange liquid chromatography mass spectrometry (LC/MS) has been investigated. The work was performed using a dual-sprayer source. The analyte was introduced through an electrospray ionisation sprayer and D2O was introduced through an atmospheric pressure chemical ionisation sprayer. To achieve H/D exchange sufficient to determine the number of exchangeable H atoms of a compound, a saturated 'steady-state' D2O atmosphere had to be created in the ion source by having a 2:1 or higher D2O-to-analyte flow rate ratio. Under these conditions H/D exchange levels of 32-90% were achieved. In most cases the H/D exchange was sufficient to measure the number of exchangeable H atoms in some antiulcerative and anthelmintic pharmaceuticals. The concept of in-source 'on-the-fly' H/D exchange by introducing the deuterating agent via a second sprayer has been shown. It allows the integrity of the chromatographic separation to be kept, since the H/D exchange takes place post-separation.  相似文献   

8.
The desorption of an analyte by a continuous wave diode laser from a porous surface of a thin-layer plate covered with a graphite suspension is presented. The thermally desorbed analyte molecules are ionized in the gas phase by a corona discharge at atmospheric pressure. Therefore, both essential processes--the desorption and the ionization of analyte molecules, which are often performed in one step--are separated. The target preparation is easy and fast since no additional extraction process is required. The mass spectrometric background signal was mostly limited to the low mass range showing no interference with typical compounds of interest. In this study, the calmative and antihypertensive drug reserpine was chosen as model analyte, which is often used for specification of mass spectrometers. No fragmentation was observed because of efficient collisional cooling under atmospheric pressure. The influence of diode laser power and the composition of the graphite suspension were investigated, and a primary optimization was performed.  相似文献   

9.
High chromatographic resolution of wax esters (WEs) was achieved by non-aqueous reversed-phase liquid chromatography on a Nova-Pak C18 column by optimising the acetonitrile/ethyl acetate mobile phase gradient. The retention behaviour of WEs was studied in this chromatographic system. The WEs eluted according to their equivalent carbon number (ECN) values; within the group of WEs with the identical ECN, the most unsaturated species tended to elute first. The isobaric WEs with different positions of the ester moiety were separated from each other whenever the lengths of the chains were sufficiently different. The methyl-branched esters eluted at shorter retention times than the straight-chained analogues, and the resolution among methyl-branched WEs depended on the position of the branching. The analytes were detected by atmospheric pressure chemical ionisation mass spectrometry (APCI-MS) using data-dependent scanning. WEs provided simple full-scan spectra with abundant protonated molecules and low-intensity fragments. Collision-induced dissociation (CID) promoted identification of the WE molecular species. The responses of WEs were found to be dependent on the number of double bonds and on the alkyl-chain length; the limits of the detection ranged from 20 μmol/L to 200 nmol/L. The HPLC/APCI-MS was applied for the analysis of the WEs isolated from honeycomb beeswax, jojoba oil and human hair. Good agreement between reported results and the literature data was achieved, with several novel polyunsaturated WEs also being found.  相似文献   

10.
The production of bacteriohopanepolyols (BHPs) is widespread in many different groups of prokaryotes; however, unsaturated components are less common except amongst the acetic acid bacteria. Here we describe the characterisation of mono- (Delta(6) or Delta(11)) and diunsaturated (Delta(6,11)) bacteriohopanetetrols isolated from the acetic acid bacterium Gluconacetobacter xylinus (formerly Acetobacter aceti ssp. xylinum) by atmospheric pressure chemical ionisation ion trap mass spectrometry (APCI-MS(n)). APCI-MS(2) spectra are compared with equivalent electron ionisation (EI) spectra and differences in fragmentation pathways are discussed. Having established characteristic spectral features for a range of unsaturated BHPs we now have the ability to rapidly detect the presence of unsaturated BHPs in both natural environmental samples (soils, sediments, water columns) as well as in microbial cultures.  相似文献   

11.
An analytical method is presented for the determination of chlorantraniliprole residues in crops. Chlorantraniliprole residues were extracted from crop matrixes with acetonitrile after a water soak. The extracts were passed through a strong anion-exchange (SAX) SPE cartridge stacked on top of a reversed-phase (RP) polymer cartridge. After both cartridges were rinsed and vacuum-dried, the SAX cartridge was removed, and chlorantraniliprole was eluted from the RP polymer cartridge with acetonitrile. The acetonitrile eluate was evaporated to dryness, reconstituted, and analyzed using an LC/MS/MS instrument equipped with an atmospheric pressure chemical ionization source. The method was successfully validated at 0.010, 0.10, and 10 mg/kg for the following crop matrixes: potatoes, sugar beets (tops), lettuce, broccoli, soybeans, soybean forage, tomatoes, cucumbers, oranges, apples, pears, peaches, almonds (nutmeat), rice grain, wheat grain, wheat hay, corn stover, alfalfa forage, cottonseed, grapes, and corn grain. The average recoveries from all crop samples fortified at the method LOQ ranged from 91 to 108%, with an overall average recovery of 97%. The average recoveries from all crop samples fortified at 10 times the method LOQ ranged from 89 to 115%, with an overall average recovery of 101%. For all of the fortified control samples analyzed in this study, the overall average recovery was 99%.  相似文献   

12.
Bacteriohopanepolyols (BHPs) are membrane lipids produced by a wide range of eubacteria. Their use, however, as molecular markers of bacterial populations and processes has until recently been hampered by the lack of a suitable rapid method for fingerprinting their composition in complex environmental matrices. New analytical procedures employing ion trap mass spectrometry now allow us to investigate the occurrence of BHPs in diverse biological and environmental samples including bacterial cultures, soils, and recent and ancient sediments. Here, we describe the structural characterisation using atmospheric pressure chemical ionisation liquid chromatography/ion trap mass spectrometry (APCI-LC/MS(n)) of a number of previously identified but less commonly occurring BHPs such as adenosylhopane and ribonylhopane. Many of the structures described here have previously only been reported in one or just a small number of cultured organisms having been isolated from large amounts of cellular mass (4-26 g) and identified by nuclear magnetic resonance (NMR) techniques after purification of individual compounds. Now, having established characteristic APCI fragmentation patterns, it is possible to rapidly screen many more bacterial cultures using only small amounts of material (<50 mg) as well as environmental samples for these atypical structures and a rapidly growing suite of novel structures.  相似文献   

13.
Atmospheric pressure chemical ionisation liquid chromatography/multistage mass spectrometry (APCI-LC/MSn) provides a rapid, on-line method for the assignment of individual bacteriophaeophorbide c and d methyl esters (BPMEs) in complex mixtures. The MS2 spectrum for each component is diagnostic of the type of BPME (c or d), and characteristic losses in MS5 and MS6 permit assignment of the alkyl substituents at positions C-8 and C-12 of the macrocycle. MS5 mass chromatograms permit the deconvolution of coeluting isobaric BPMEs, revealing the true profiles of the individual components. The distributions are different in lake sediments from la Salada de Chiprana (Spain) and Kirisjes Pond (Antarctica), and a novel BPME c with a neo-pentyl substituent has been observed in the Kirisjes Pond sediment.  相似文献   

14.
Using the high performance liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (HPLC/APCI-MS/MS) technique, together with established trends from the literature, the structures of metabolites and impurities of amiodarone, an anti-arrhythmic drug, have been assigned. By comparing analyses of products of incubation with rat liver microsomes with controls in which glucose 6-phosphate dehydrogenase was omitted, metabolites could be distinguished from impurities. Structures for the two proposed metabolites and four impurities are proposed.  相似文献   

15.
The present work describes the development and application of an on-line atmospheric pressure ionisation (APCI) LC-MS interface for the simultaneous determination of seven toxicologically relevant cholesterol oxides (7alpha-hydroxycholesterol, 7beta-hydroxycholesterol, 25-hydroxycholesterol, 7-ketocholesterol, 5,6alpha-, 5,6beta-epoxycholesterol and cholestan-3beta,5alpha,6beta-triol). The HPLC method has been optimised to reach better separation of all tested compounds. The influences of APCI parameters (nebulising temperature, cone voltage, source temperature) on signal intensity and fragmentation pattern were investigated for all tested cholesterol oxides compounds. This is the first report on optimisation and determination of two compounds 7alpha-hydroxycholesterol and 5,6beta-epoxycholesterol in processed food using LC-MS. After extraction with hexane, clean-up was carried out using solid-phase extraction on a silica column. For the chromatographic separation of cholesterol oxides an Aquasil C18 column was used with acetonitrile-methanol (60:40) as mobile phase. For the first time we report the use of such a C18 column with a relatively hydrophilic nature for the separation of cholesterol oxides. APCI-MS detection was then applied in selected ion monitoring and positive ion modes by using the molecular ions and the main fragments. The developed method shows good linearity, high repeatability and good recovery for all tested cholesterol oxides. The method was applied for determination of seven selected cholesterol oxidation products in different foodstuffs such as butter, butteroil, lard and egg powder.  相似文献   

16.
The narrow gap between essentiality and toxicity of selenium requires detailed investigations on selenium metabolism in order to find suitable indicators for the selenium status in the human body. Current methods for quantitative selenium speciation in human urine are based on separation by high-performance liquid chromatography (HPLC) coupled online with elemental mass spectrometry (MS), and the potential of molecular MS detection techniques for the reliable identification and quantification of selenosugars in crude human urine has not been utilized. Now we report the development of an HPLC tandem mass spectrometric (MS/MS) method for the reliable determination in crude human urine of three significant selenium urinary metabolites, collectively termed selenosugars, namely methyl 2-acetamido-2-deoxy-1-seleno-beta-D-galactopyranoside (SeGalNAc), methyl 2-acetamido-2-deoxy-1-seleno-beta-D-glucopyranoside (SeGluNAc) and methyl 2-amino-2-deoxy-1-seleno-beta-D-galactopyranoside (SeGalNH2). Reversed-phase HPLC, with and without cation-exchange guard columns, was applied for the separation of the selenosugars, and atmospheric pressure chemical ionization (APCI) and selected reaction monitoring (SRM) were used for selective and sensitive detection. The collision-induced dissociation behaviour of the selenosugars was studied in detail using APCI triple quadrupole MS/MS and electrospray ion trap MS. The developed method was applied to urine samples collected prior to and after selenium supplementation for the quantification of SeGalNAc using both external calibration and the method of standard additions. Additionally, SeGalNH2 was detected in urine samples after Se supplementation. Finally, neutral loss scanning was explored as a possible method for the detection of unknown methyl-selenosugars.  相似文献   

17.
Atmospheric pressure chemical ionisation liquid chromatography/multi-stage ion trap mass spectrometry (APCI-LC/MS(n)) has been applied to the study of intact bacteriohopanepolyols. Spectral characterisation of bacteriohopanepolyols of known structure present in bacterial extracts (Zymomonas mobilis and a fermenter containing methanotrophs including Methylococcus capsulatus) has revealed greater structural detail than previous liquid chromatography/mass spectrometry (LC/MS) methods and identified characteristic fragmentations indicative of numerous biohopanoid structures. Analysis of a Recent sedimentary extract from Lake Druzhby (Antarctica) has demonstrated the power of this technique to detect biohopanoids in complex samples including at least partial characterisation of previously unknown composite structures.  相似文献   

18.
An atmospheric pressure proximal probe thermal desorption sampling method coupled with secondary ionization by electrospray or atmospheric pressure chemical ionization was demonstrated for the mass spectrometric analysis of a diverse set of compounds (dyestuffs, pharmaceuticals, explosives and pesticides) separated on various high‐performance thin‐layer chromatography plates. Line scans along or through development lanes on the plates were carried out by moving the plate relative to a stationary heated probe positioned close to or just touching the stationary phase surface. Vapors of the compounds thermally desorbed from the surface were drawn into the ionization region of a combined electrospray ionization/atmospheric pressure chemical ionization source where they merged with reagent ions and/or charged droplets from a corona discharge or an electrospray emitter and were ionized. The ionized components were then drawn through the atmospheric pressure sampling orifice into the vacuum region of a triple quadrupole mass spectrometer and detected using full scan, single ion monitoring, or selected reaction monitoring mode. Studies of variable parameters and performance metrics including the proximal probe temperature, gas flow rate into the ionization region, surface scan speed, read‐out resolution, detection limits, and surface type are discussed. Published in 2010 by John Wiley & Sons, Ltd.  相似文献   

19.
A determination method for steroid 5alpha-reductase activity using liquid chromatography/atmospheric pressure chemical ionization-mass spectrometry (LC/APCI-MS) in the positive-ion mode has been developed. The rat prostatic enzyme source was used and the enzymatically formed 5alpha-dihydrotestosterone and 5a-androstane-3alpha,17beta-diol were determined by LC/APCI-MS using absolute calibration curve method. The sum of the formed products was used as a measurement of the enzyme activity. This method was applied to kinetic study of this enzyme and inhibitory experiments using Finasteride as a model inhibitor.  相似文献   

20.
A simple liquid chromatography/mass spectrometry (LC/MS) approach for the determination of widely used representatives of polar/thermolabile pesticides in fruits was developed and validated. The group of pesticides comprised benzimidazoles and azoles (carbendazim, thiabendazole, imazalil, propiconazole, prochloraz, epoxiconazole, flusilazole, tebuconazole, bitertanol); N-methylcarbamates (carbaryl, carbofuran, methiocarb); and phenylureas and benzoylphenylureas (linuron, diflubenzuron, triflumuron, teflubenzuron, flufenoxuron). Matrixes (apple, apricot) were extracted with acetonitrile and crude extracts were cleaned up by solid-phase extraction (SPE) using either mixed cation exchange or hydrophilic lipophilic balance cartridges. LC separation of pesticides was performed on a reversed-phase column, Discovery C18. Electrospray ionization and ion trap MS/MS detection were applied. For most pesticides, overall recoveries ranged from 75 to 122%, and repeatability (as relative standard deviation) from 5 repetitive determinations of recovery ranged from 3 to 21%. Carbofuran was the only compound for which recovery was not satisfactory due to its loss in the SPE cleanup step. Limits of detection were 0.1-3 microg/kg for benzimidazole and azole fungicides and carbamate insecticides. For urea insecticides, detection limits were slightly higher (3-10 microg/kg).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号