首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
Proton-transfer-reaction mass spectrometry (PTR-MS) is a powerful technique for the real time trace gas analysis of volatile organic compounds (VOCs). However, quadrupole mass spectrometer (MS) used in PTR-MS has a relatively low mass resolution and is therefore not suitable for differentiating isobars. Furthermore, because of the lack of chemical separation before analysis, isomers can not be identified, either. In the present study, by varying the reduced-field E/N in the reaction chamber with a range of 50–180 Td in PTR-MS, we studied the product ion distribution (PID) of three sets of isobars/isomers, i.e. n-propanol/iso-propanol/acetic acid, propanal/acetone and four structural isomers of butyl alcohol. The profiles of the reduced-field dependence (PFD) of the PID under the chosen E/N-values show obvious differences which can be used to discriminate between these isobars/isomers thus enabling the titled method. Noticeably, we have observed that even the isomers, in the case of four structural isomers of butyl alcohol, which show little difference with each other at high reduced-field, can be discriminated easily at low reduced-field. Finally, two examples for the application of this method are discussed: (1) cyclohexanone was identified to be a major compound in the headspace of medical infusion sets; and (2) the differentiation and quantification of propanal and acetone in three synthetic mixtures with different ratios. This study presents a potential method to distinguish and quantify isobars/isomers conveniently in practical applications of PTR-MS analysis without additional instrumental configurations.  相似文献   

2.
Four new 3-alkyl pyridinium alkaloids, the viscosalines?B(1) (1?a), B(2) (1?b), E(1) (2?a), and E(2) (2?b), were isolated from the Arctic sponge Haliclona viscosa. The structure elucidation of these isomeric compounds was challenging due to ambiguous fragments that derive during "standard" mass spectrometric fragmentation experiments. The final structure elucidation relied on the use of a combination of synthesis, liquid chromatography, and mass spectrometry. Three different mass spectrometers were used to differentiate between the synthetic structural isomers: a time-of-flight (TOF) mass spectrometer and two ion-trap mass spectrometers with different ion-transfer technologies (i.e., skimmer versus funnel optics). Although at first none of the spectrometers returned spectra that permitted structure elucidation, all three mass spectrometers provided analysis that successfully differentiated between the isomers after thorough method optimization. The use of in-source collision-induced dissociation (CID) with the ion trap and TOF instrument returned the most interesting results. The mode of fragmentation of the viscosalines under different experimental conditions is described herein. After successful optimization of the mass spectrometric method applied, the chromatographic method was improved to distinguish the previously inseparable isomers. Finally, both the liquid chromatography and mass spectrometric methods were applied to the natural products and the results compared to those from the synthetic compounds.  相似文献   

3.
An electrospray ionization tandem mass spectrometry (ESI-MS/MS) library which contains over 5,600 spectra of 1,253 compounds relevant in clinical and forensic toxicology has been developed using a hybrid tandem mass spectrometer with a linear ion trap. Pure compound solutions—in some cases solutions made of tablets—were prepared and 1 to 2,000 ng of each compound were injected into the system using standard reversed-phase analytical columns with gradient elution. To obtain maximum mass spectral information enhanced product ion spectra were acquired with positive and/or negative ionization at low, medium, and high collision energies and additionally applying collision energy spread. In this mode, all product ions generated by the different collision energies are trapped in the linear ion trap prior to their detection. The applicability of the library for other types of hybrid tandem mass spectrometers with a linear ion trap of the same manufacturer as well as a standard triple-quadrupole tandem mass spectrometer has been investigated with a selection of compounds. The spectra of the developed library can be used to create methods for target analysis, either screening methods or quantitative procedures by generating transitions for multiple reaction monitoring. For those procedures, suitable transitions and convenient collision energies are selected from the library. It also has been utilized to identify compounds with a multi target screening approach for clinical and forensic toxicology with a standardized and automated system. The novel aspects compared to our former library produced with a standard triple-quadrupole mass spectrometer are the enlargement of the ESI-MS/MS library and the additional acquisition of spectra with collision energy spread.  相似文献   

4.
气相色谱/离子阱质谱中组分图谱提取的主成分分析方法   总被引:2,自引:0,他引:2  
苏越  廖远熹  郭寅龙 《化学学报》2007,65(14):1377-1380
由于离子阱质谱中容易发生分子-离子反应, 致使质谱图发生改变, 影响与主要由四极质谱建立的参照图谱的匹配效果. 本文采用主成分分析方法对气相色谱/离子阱质谱中组成色谱峰的所有全扫描质谱进行提取, 提取后的质谱图能够有效克服分子-离子反应和基线干扰的影响, 应用不同的匹配算法均能很好地和参照图谱匹配, 和传统方法相比匹配度显著提高, 对目标化合物定性准确.  相似文献   

5.
Four new 3‐alkyl pyridinium alkaloids, the viscosalines B1 ( 1 a ), B2 ( 1 b ), E1 ( 2 a ), and E2 ( 2 b ), were isolated from the Arctic sponge Haliclona viscosa. The structure elucidation of these isomeric compounds was challenging due to ambiguous fragments that derive during “standard” mass spectrometric fragmentation experiments. The final structure elucidation relied on the use of a combination of synthesis, liquid chromatography, and mass spectrometry. Three different mass spectrometers were used to differentiate between the synthetic structural isomers: a time‐of‐flight (TOF) mass spectrometer and two ion‐trap mass spectrometers with different ion‐transfer technologies (i.e., skimmer versus funnel optics). Although at first none of the spectrometers returned spectra that permitted structure elucidation, all three mass spectrometers provided analysis that successfully differentiated between the isomers after thorough method optimization. The use of in‐source collision‐induced dissociation (CID) with the ion trap and TOF instrument returned the most interesting results. The mode of fragmentation of the viscosalines under different experimental conditions is described herein. After successful optimization of the mass spectrometric method applied, the chromatographic method was improved to distinguish the previously inseparable isomers. Finally, both the liquid chromatography and mass spectrometric methods were applied to the natural products and the results compared to those from the synthetic compounds.  相似文献   

6.
在常规质谱中,各种同分异构的稠环芳香烃基本上无法分辨。但在本文报道的以近红外脉冲激光所产生的等离子体质谱中,所分析的四个四稠环芳香烃尽管分子量相同,其负离子质谱却有十分明显的差异,显示了这一研究方法的结构鉴别能力。  相似文献   

7.
Two major metabolites and one minor metabolite of sulfadiazine were found in pig manure, using a special combination of different MS techniques like parent and product ion scans, H/D exchange, accurate mass measurement, and MS/MS experiments with substructures. N4-acetylsulfadiazine and 4-hydroxysulfadiazine were identified as major metabolites. N4-acetylsulfadiazine could be verified by H/D exchange and comparison with product ion spectra of a synthetic reference compound. In the case of 4-hydroxysulfadiazine, the majority of possible isomers could be discounted after H/D exchange. Substructure-specific MS/MS experiments with fragment ions and comparison with product ion spectra of two references revealed the presence of 4-hydroxysulfadiazine. The minor metabolite was characterized to some degree using H/D exchange and tandem mass spectrometry in combination with a high-resolution time of flight mass spectrometer. The aminopyrimidine moiety contained an additional modification with a likely elemental composition of C2H4O and no further acidic hydrogen.  相似文献   

8.
The application of low-temperature pyrolysis mass spectrometry to the identification of some commercial and synthetic polymers using a direct insertion probe and electron ionization has been studied. The polymers were analyzed directly in the solid probe of a mass spectrometer within the ion source at 70 eV electron impact. The quadrupole mass spectrometer, equipped with a gas chromatogram software and library of low molecular weight compounds, was used to characterize the polymers by measuring the chemical structure of the repeat units and the end groups, and to examine the thermal degradation pathways. The polymers investigated show different degradation pathways. Investigation of sequences and determination of composition of copolymers were studied. Total ion pyrogram and spectrum subtractions were used to separate and measure spectra of pyrolysis steps at distinctly different temperatures.  相似文献   

9.
The ion kinetic energy (IKE) spectra of the isomeric di-and trichlorobenzenes have been examined and the data for the latter compounds suggested that there was incomplete chlorine randomization in their molecular ions in the first field-free region of the mass spectrometer. Previous studies on the mass spectra and [metastable ion]/[daughter ion] ratios of the di-, tetra- and hexachlorobiphenyls (PCB's) indicated chlorine randomization in the molecular ions of those isomers containing less than two chlorine groups ortho to the Ph-Ph ring junction. In contrast the IKE spectra of the isomers are different and the results indicate incomplete chlorine randomization in the first field-free region of the mass spectrometer. These spectral differences may be of some use in PCB analysis.  相似文献   

10.
This paper describes a way of differentiating between the three isomers of estriol glucuronide by the use of chemical derivatization and liquid chromatography/electrospray tandem mass spectrometry (MS/MS). In their native form, these isomers gave rise to almost identical product ion spectra, involving the neutral loss of 176 Da (i.e. monodehydrated glucuronic acid), which made it impossible to determine the position of conjugation by MS/MS alone. In order to change the fragmentation pathways, positive charges were introduced into the analytes by chemical derivatization. The following reagents were tested: 2-chloro-1-methylpyridinium iodide, 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and 2-picolylamine. Interestingly, derivatization using a combination of all three reagents gave a selective fragmentation pattern that could differentiate between the isomers estriol-16-glucuronide and estriol-17-glucuronide. Estriol-3-glucuronide, which lacks a free phenolic group, could be differentiated through a different type of reaction product when exposed to 2-chloro-1-methylpyridinium iodide. Furthermore, in order to assist structural assignment of the fragments, their accurate masses were determined using a hybrid quadrupole time-of-flight mass spectrometer and fragmentation pathways were elucidated by the use of MS3 on an ion trap mass spectrometer.  相似文献   

11.
The content of 24 12-membered heptapeptide libraries was investigated using capillary liquid chromatography coupled with an electrospray ionization quadrupole orthogonal acceleration time-of-flight mass spectrometer. Adjustment of the chromatographic parameters led to the separation of most of the components. Extraction of the [M + 2H]2+ ions allowed us to demonstrate the presence of all expected species in the library and to evaluate their relative abundance in the mixture. Rapid sequence confirmation was achieved by subtraction of product ion spectra, a way to eliminate common ions and to simplify the spectra for interpretation. This technique can also easily be applied to other libraries consisting of components with a common core.  相似文献   

12.
Oil-sand naphthenic acids (NAs) are organic wastes produced during the oil-sand digestion and extraction processes and are very difficult to separate and analyze as individual components due to their complex compositions. A comprehensive two-dimensional gas chromatography/time of flight mass spectrometry (GC x GC/TOF-MS) system was applied for the characterization of two commercial mixtures of naphthenic acids (Fluka and Acros) and a naphthenic acid sample extracted from the Syncrude tailings. Contour plots of chromatographic distributions of different Z homologous series of the Fluka, Acros and Syncrude NAs were constructed using fragment ions that were characteristic of the NA's molecular structures. Well-ordered patterns were observed for NAs of Z= 0 and -2 which corresponded to acyclic acids and monocyclic acids, respectively. For NAs of Z= -4, -6, and -8, specific zones were observed which would allow the pattern recognition of these NAs obtained from different origins. As expected, gas chromatographic retention times increase with the number of the carbons and the number of rings in the molecules. Little signal was obtained for NAs with Z numbers of -10, or lower. Deconvoluted mass spectra of various NA isomers were derived from the reconstructed GC x GC chromatogram, permitting detailed structural elucidations for NAs in the future. The current study demonstrated that the combination of GC x GC and the TOF-MS is a powerful to identify origins of the NAs in an effective manner. GC x GC/TOF-MS alone, however, may not be enough to characterize each individual isomer in a complex mixture such as NAs. The use of mass deconvolution software followed by library search have thus become necessary to separate and study the mass spectrum of each individual NA component, allowing a detailed identification of the toxic components within the NAs mixture.  相似文献   

13.
Approximately 300,000 compounds from selected libraries were screened against a subdomain of a hepatitis C viral (HCV) RNA using a high throughput flow injection mass spectrometry (FIA-MS) method with automated data storage and analysis. Samples contained 2 microM RNA target and 10 microM of each of up to ten ligands. Preliminary studies to optimize operational parameters used the binding of aminoglycosides to the A44 subdomain of bacterial RNA. Binding (confirmed by titration) and sensitivity were maximized within the constraints of the library and throughput. The mobile phase of 5 mM ammonium acetate in 50% isopropanol maintained the noncovalent complexes and provided good detection by electrospray mass spectrometry. Additionally, this composition maximized general solubility of the various classes of compounds including the oligonucleotide and organic library molecules. Cation adduction was insignificant in this screen although some solute and target dependent acetate adduction was observed. The ion trap mass spectrometer provided sufficient mass resolution to identify complexes of RNA with known components of the library. Converted mass spectral data (netCDF) were subjected to two types of statistical evaluation based on binding. The first algorithm identified noncovalent complexes that correlated with the molecular weights of the injected compounds. The second yielded the largest peak in the noncovalent complex region of the spectrum; this spectrum may or may not correlate with expected well components. Sixty-three compounds were confirmed to bind by more stringent secondary testing. Titrations, which were carried out with selected binding compounds, yielded a range of dissociation constants. Biological activity was observed for eleven confirmed binders.  相似文献   

14.
A nine-channel multiplexed electrospray (MUX) liquid chromatography ultraviolet time-of-flight mass spectrometry (LC/UV/TOFMS) system has been used to simultaneously measure accurate masses of eluting components from eight parallel gradient LC columns. Accuracies better than 5 and 10 ppm were achieved for 50 and 80% of samples, respectively, from a single batch analysis of ten plates (960 samples) of a Fmoc-Asp(OtBu)-OH and reserpine mixture. Combinatorial library compounds were analyzed using this parallel high-throughput system in both positive and negative modes to rigorously verify expected products and identify side products. A mass accuracy of 10 ppm root mean square (RMS) is routinely obtained for combinatorial library samples from this high-throughput accurate mass LC/MS system followed by automated data processing. This mass accuracy is critical in revealing combinatorial synthesis problems that would be missed by unit mass measurement.  相似文献   

15.
A compound library consisting of 144 pyrazole carboxylic acids and six sublibraries consisting of 24 components was analysed using electrospray ionisation Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS). The library was synthesised by the split-mix method and investigated by direct infusion analysis by which 134 compounds were detected. FTICR-MS is predestined for the direct characterisation of complex compound libraries because of its outstanding mass resolution and mass accuracy. However, discrimination within the electrospray ionisation process sometimes leads to signal suppression and thus to misinterpretation of the synthetic results. Using micro-HPLC/MS we were able to assign all 144 compounds including all pairs of isobaric pyrazoles. We also show that, due to partial separation, FTICR-MS is indispensable for proper detection of co-eluting compounds.  相似文献   

16.
In this paper the application of on-line HPLC-UV-APCI (atmospheric pressure chemical ionization) mass spectrometry (MS) coupling for the separation and determination of different carotenoids as well as cis/trans isomers of beta-carotene is reported. All HPLC separations were carried out under RP conditions on self-synthesized polymeric C30 phases. The analysis of a carotenoid mixture containing astaxanthin, canthaxanthin, zeaxanthin, echinenone and beta-carotene by HPLC-APCI-MS was achieved by scanning the mass range from m/z 200 to 700. For the characterization of a sample containing cis/trans isomers of beta-carotene as well as their oxidation products, a photodiode-array UV-visible absorbance detector was used in addition between the column and the mass spectrometer for structural elucidation of the geometrical isomers. The detection limit for beta-carotene in positive-ion APCI-MS was determined to be 1 pmol. In addition, an extract of non-polar substances in vegetable juice has been analyzed by HPLC-APCI-MS. The included carotenoids could be identified by their masses and their retention times.  相似文献   

17.
《Analytical letters》2012,45(2):290-307
Abstract

Distinguishing chemicals and improvement on analytical methods has a direct impact on modern chemical analysis. In this work, the dissociative ionization of xylene isomers was investigated using a femtosecond laser mass spectrometry (FLMS) method with a custom-built linear time-of-flight (TOF) instrument. Laser beams at 800?nm and 400?nm were used and intensity-dependent analysis of the obtained mass spectra was performed using principal component analysis (PCA) to distinguish the xylene isomers, which give identical mass spectra in appearance that cannot be distinguished using normal mass spectrometry methods. The results show that there is a statistically highly significant difference between the xylene isomers for two principal components (1 ? α?>?99.99%) and minimal information loss (<5%) took place during the PCA procedure. Also, the use of the k-medoid clustering method showed that the isomers may be distinguished in real-time for a wide range of ionization laser pulse powers with approximately 99% accuracy. The results suggest that real-time isomer analysis by the FLMS method is suitable for mass spectral identification applications. The FLMS method has been shown to be an important alternative to other mass spectrometric methods that use different ionization mechanisms.  相似文献   

18.
The recently developed technique of desorption electrospray ionization (DESI) has been applied to the rapid analysis of controlled substances. Experiments have been performed using a commercial ThermoFinnigan LCQ Advantage MAX ion-trap mass spectrometer with limited modifications. Results from the ambient sampling of licit and illicit tablets demonstrate the ability of the DESI technique to detect the main active ingredient(s) or controlled substance(s), even in the presence of other higher-concentration components. Full-scan mass spectrometry data provide preliminary identification by molecular weight determination, while rapid analysis using the tandem mass spectrometry (MS/MS) mode provides fragmentation data which, when compared to the laboratory-generated ESI-MS/MS spectral library, provide structural information and final identification of the active ingredient(s). The consecutive analysis of tablets containing different active components indicates there is no cross-contamination or interference from tablet to tablet, demonstrating the reliability of the DESI technique for rapid sampling (one tablet/min or better). Active ingredients have been detected for tablets in which the active component represents less than 1% of the total tablet weight, demonstrating the sensitivity of the technique. The real-time sampling of cannabis plant material is also presented.  相似文献   

19.
An extract fraction fruits of Arbutus unedo, L., was cleaned-up by column chromatography and shown by NMR to be a mixture of isomers that resists further attempts at separation by conventional chromatographic methods. High resolution gas chromatography-mass spectrometry (HRGC-MS) confirms the presence of triter-penoid isomers but does not allow separation of all the components. This can be improved by trimethylsilylation but the absence of molecular ions and the complex spectra are difficult to interpret. Complete separation can be achieved by high pressure liquid chro-matography (HPLC) coupled to a mass spectrometer by means of a particle beam interface (HPLC-PBMS). Four triterpene com-pounds are identified through analysis of the corresponding mass spectra: α-amyrin, β-amyrin, and Lupeol, have for the first time been identified in Arbutus unedo, L. Fruits. A new natural triterpene tentatively identified as olean-12-en-3β, 23-diol is described for the first time.  相似文献   

20.
A technique using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOFMS) is applied to a qualitative analysis of three sample extracts from hair suspected of containing various drug compounds. The samples were also subjected to a quantitative target analysis for codeine, morphine, 6-monoacetylmorphine (6-MAM), amphetamine, methamphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethylamphetamine (MDMA), methadone, and benzylpiperazine (BZP) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). GC × GC/TOFMS provided a non-specific procedure that identified various drugs, metabolites, and impurities not included in the target analysis. They included cocaine, diazepam, and methaqualone (quaalude). Comprehensive GC × GC separation was achieved using twin-stage cryo-modulation to focus eluant from a DB-5ms (5% phenyl) to a BPX50 (50% phenyl) GC column. The TOF mass spectrometer provided unit mass resolution in the mass range m/z 5–1000 and rapid spectral acquisition (≤500 spectra/s). Clean mass spectra of the individual components were obtained using mass spectral deconvolution software. The ‘unknown’ components were identified by comparison with mass spectra stored in a library database.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号