首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
This study focused on the detection and quantification of organic micelle-type nanoparticles (NPs) with polysorbate components (polysorbate 20 and polysorbate 80) in their micelle shells that could be used to load biologically active compounds into fruit juice. Several advanced analytical techniques were applied in the stepwise method development strategy used. In the first phase, a system consisting of ultrahigh-performance liquid chromatography employing a size exclusion column coupled with an evaporative light scattering detector (UHPLC-SEC-ELSD) was used for the fractionation of micelle assemblies from other, lower molecular weight sample components. The limit of detection (LoD) of these polysorbate micelles in spiked apple juice was 500 μg mL?1. After this screening step, mass spectrometric (MS) detection was utilized to confirm the presence of polysorbates in the detected micelles. Two alternative MS techniques were tested: (i) ambient high-resolution mass spectrometry employing a direct analysis in real time ion source coupled with an Orbitrap MS analyzer (DART-Orbitrap MS) enabled fast and simple detection of the polysorbates present in the samples, with a lowest calibration level (LCL) of 1000 μg mL?1; (ii) ultrahigh-performance reversed-phase liquid chromatography coupled with high-resolution time-of-flight mass spectrometry (UHPLC-HRTOF-MS) provided highly selective and sensitive detection and quantification of polysorbates with an LCL of 0.5 μg mL?1.  相似文献   

2.
A validated ultrahigh-performance liquid chromatography method using 1.7 μm core–shell particles is presented for the identification and quantification of β-carotene (BC) and related cleavage products (CPs) in primary cell culture media. Besides BC, apo-4′-, apo-8′-, apo-10′-, and apo-12′-carotenals, as well as 5,6-epoxy-β-carotene, were selected as target analytes. Detection was performed via an 80-Hz diode array detector and an electrospray ionization–linear quadrupole ion trap–Orbitrap XL mass spectrometer, both hyphenated in series. Total analysis time was below 6 min with peak widths <12 s. Addition of trifluoroacetic acid and tetrahydrofuran to the mobile phase allowed for the mass spectrometric detection of BC and related CPs and reduced peak tailing due to improved solubility of hydrophobic analytes. Intra-day and inter-day precision for UV and mass spectrometric detection were ≤1.5 % for retention times and ≤5.1 % for peak areas. Instrumental linearity was confirmed by Mandel’s fitting test between 0.25 (or 1.00 μg/mL) and 5.00 μg/mL for UV detection. The higher sensitivity of mass spectrometric detection allowed for the coverage of three concentration domains between 0.025 and 5.00 μg/mL in linearity testing. Homoscedasticity was confirmed between 0.10 and 5.00 μg/mL for Orbitrap XL MS. The limits of quantification were between 52.6 and 889.4 ng/mL for UV detection and between 19.3 and 102.4 ng/L for mass spectrometric detection. Offline solid-phase extraction from culture media fortified with BC and CPs provided intra- and inter-day recoveries between 65.8 and 102.4 % with coefficients of variation ≤6.2 %. Primary rat hepatocyte cultures treated with BC and subjected to different oxidative stress conditions contained 5,6-epoxy-BC and apo-4′-carotenal besides residual BC. Apparently, 5,6-epoxy-BC was formed in the medium via autoxidation of BC by ambient oxygen.  相似文献   

3.
《Analytical letters》2012,45(3):408-423
A solid phase derivative extraction method using acetic anhydride was developed for the determination of chlorophenols and alkylphenols in water and fruit juice by gas chromatography–mass spectrometry (GC–MS). The quantitative extraction was performed by passing 100 mL of sample prepared in 0.1 mol L?1 sodium hydroxide through a column packed with 500 mg of a strong anion-exchange resin at a flow rate of 0.75 mL min?1. The retained phenols were quantitatively derivatized in the column by the introduction of 0.25 mL of acetic anhydride. The derivatized phenols were eluted with 3.0 mL of hexane and the effluent was dried under nitrogen. The final volume was diluted to fifty microliters with hexane and analyzed by GC–MS. Under the optimum conditions, preconcentration factors of 2000, limits of detection between 0.005 and 1.796 µg L?1, and relative standard deviations of 2.1% to 6.7% were obtained. The method was successfully applied to wastewater and fruit juice and the recoveries of phenols were between 76% and 111%.  相似文献   

4.
A GC-MS method with HP-5MS capillary column was developed for the simultaneous determination of underivatized flunitrazepam, clonazepam, alprazolam, diazepam and ketamine from drinks by extraction with chloroform: isopropanol 1:1 (v/v). All linearity ranges were between 50 and 1,000 μg mL?1 for all compounds both in beer and in peach juice. Limit of detection was between 1.3 and 34.2 μg mL?1, limit of quantification was between 3.9 and 103.8 μg mL?1, the range of recoveries was 73.0 and 112.6% for all drugs in both beverages. The reported method was sensitive, rapid, and suitable for the analysis of the spiked drinks as evidence of sexual assault and robbery phenomena.  相似文献   

5.
Nitraria sibirica is a traditional Uighur medicine. This study was undertaken to investigate the bioactivity of N. sibirica fruit extract and to evaluate their chemical compositions. The ethyl acetate extract from N. sibirica fruits exhibited the potential antioxidant activity (SC50 = 30.17 ± 0.06 μg/mL) and protein tyrosine phosphatase 1B inhibitory activity (IC50 = 7.15 ± 0.03 μg/mL) in vitro. In order to investigate the active constituents in this extract, a LC-QTOF-MS/MS method was developed and established. A total of 28 compounds including seven cinnamic acids, nine benzoic acids and 12 flavonoids were identified or partially characterised according to the accurate mass and the characteristic fragment ions at low and high collision energy. Most of them were reported for the first time in this plant. Phytochemical profiles of the active extract will help the development and utilisation of N. sibirica in food and medicine.  相似文献   

6.
A rapid, simple and sensitive, liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for simultaneous determination of bergenin, chlorogenic acid and four flavonoids in a QingGanSanJie preparation in rat plasma. Puerarin was selected as the internal standard (IS). Plasma samples were precipitated with methanol and separated with a reverse phase Agilent Poroshell 120 EC‐C18 column using a gradient mobile phase of methanol–water containing 0.1% formic acid (v/v). A triple quadruple mass spectrometer was used for quantification (limit of detection 0.36–5.55 ng/mL). Intra‐day and inter‐day precisions were within 15% and the average extraction recoveries ranged from 85 to 115% for each analyte. The method allowed simultaneous quantification for the first time of the pharmacokinetics of bergenin, chlorogenic acid and four flavonoids after intragastric administration of a QingGanSanJie extract in Sprague–Dawley rats. It was found that bergenin and chlorogenic acid had typical extravascular administration concentration–time curves; flavonoids had a bimodal distribution improving bioavailability and extending the pharmacodynamics period. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
A fast and effective preconcentration method for extraction of organochlorine pesticides (OCPs) was developed using a homogeneous liquid–liquid extraction based on phase separation phenomenon in a ternary solvent (water/methanol/chloroform) system. The phase separation phenomenon occurred by salt addition. After centrifugation, the extraction solvent was sedimented in the bottom of the conical test tube. The OCPs were transferred into the sedimented phase during the phase separation step. The extracted OCPs were determined using gas chromatography–electron capture detector. Several factors influencing the extraction efficiency were investigated and optimized. Optimal results were obtained at the following conditions: volume of the consolute solvent (methanol), 1.0 mL; volume of the extraction solvent (chloroform), 55 μL; volume of the sample, 5 mL; and concentration of NaCl, 5 % (w/v). Under optimal conditions, the preconcentration factors in the range of 486–1,090, the dynamic linear range of 0.01–100 μg L?1, and the limits of detection of 0.001–0.03 μg L?1 were obtained for the OCPs. Using internal standard, the relative standard deviations for 1 μg L?1 of the OCPs in the water samples were obtained in the range of 4.9–8.6 % (n = 5). Finally, the proposed method was successfully applied for extraction and determination of the OCPs in water and fruit samples.  相似文献   

8.
Ecgonine is suggested to be a promising marker of cocaine (COC) ingestion. A combined mass spectrometry (MS) and tandem MS (MS/MS) method was developed to simultaneously determine ecgonine and seven other metabolites of cocaine in human urine and whole blood with ultra-high-pressure liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. The compounds were extracted from as little as 100 μL of sample by solid-phase extraction with a 96-well μElution solid-phase extraction plate. The protonated molecules or fragment ions at accurate mass acquired in MS mode were used to quantify specific analytes, following by dedicated MS/MS identification. The assay was linear in the range from 5 to 50-100 ng/mL for urine samples, except for ecgonine methyl ester (10-200 ng/mL) and ecgonine (40-400 ng/mL), and was linear from 1-2 to 50 ng/mL for whole blood samples, except for ecgonine methyl ester (20-1,000 ng/mL) and ecgonine (40-2,000 ng/mL). The correlation coefficients were all greater than 0.99. The limits of detection ranged from 0.2 to 16 ng/mL, and the lower limits of quantification ranged from 1 to 40 ng/mL. The repeatability and intermediate precision were 18.1 % or less. The accuracy was in the range from 80.0 to 122.9 %, process efficiencies were in the range from 8.6 to 177.4 %, matrix effects were in the range from 28.7 to 171.0 %, and extraction recoveries were in the range from 41.0 to 114.3 %, except for ecgonine (12.8 % and 9.3 % at low and high concentrations, respectively). This method was highly sensitive in comparison with previously published methods. The validated method was successfully applied to the analysis of real samples derived from forensic cases, and the results verified that, on the basis of data from four positive samples, ecgonine is a promising marker of cocaine ingestion.
Figure
Procedure for the determination of ecgonine and seven other cocaine metabolites in human urine and whole blood using a combined mass spectrometry and tandem MS method aIer the solid‐phase extraction of the anaytes  相似文献   

9.
A simple, rapid and efficient method termed dispersive liquid–liquid microextraction combined with liquid chromatography-fluorescence detection, has been developed for the extraction and determination of polycyclic aromatic hydrocarbons (PAHs) in water and fruit juice samples. Parameters such as the kind and volume of extraction solvent and dispersive solvent, extraction time and salt effect were optimized. Under optimum conditions, the enrichment factors ranged from 296 to 462. The linear range was 0.01–100 μg L?1 and limits of detection were 0.001–0.01 μg L?1. The relative standard deviations (RSDs, for 5 μg L?1 of PAHs) varied from 1.0 to 11.5% (n = 3). The relative recoveries of PAHs from tap, river, well and sea water samples at spiking level of 5 μg L?1 were 82.6–117.1, 74.9–113.9, 77.0–122.4 and 86.1–119.3%, respectively. The relative recoveries of PAHs from grape and apple juice samples at spiking levels of 2.5 and 5 μg L?1 were 80.8–114.7 and 88.9–123.0%, respectively. It is concluded that the proposed method can be successfully applied for determination of PAHs in water and fruit juice samples.  相似文献   

10.
Yang  Qin-Feng  Wu  Yin-Liang 《Chromatographia》2012,75(17):1075-1080

A fast analytical method for the simultaneous determination of fumonisin B1 (FB1) and fumonisin B2 (FB2) in corn using a novel QuEChERS method and LC–MS–MS was developed and validated. Samples were extracted with methanol–water (3:1 v/v) by means of ultrasonic extraction. The extract was purified with a novel modified QuEChERS method. Firstly, FB1 and FB2 in the extract were retained with primary secondary amine (PSA). Then, FB1 and FB2 were released from PSA with 1.0 % formic acid in methanol. The final eluate was diluted with water, and analyzed by LC–MS–MS on a Waters Acquity BEH C18 column with 0.1 % formic acid in water/methanol as mobile phase with gradient elution. Mean recoveries of 83.5–102.4 % with CVs of 3.6–10.5 % were obtained at fortification levels of 2, 50 and 1,000 μg kg−1. The limit of quantification was 2.0 μg kg−1.

  相似文献   

11.
A new method has been developed for the simultaneous determination of 13 tropane alkaloids in tea and herbal teas using high‐performance liquid chromatography coupled to an Exactive‐Orbitrap analyzer. A mixture of methanol, water, and formic acid was used for the extraction of the target compounds followed by a solid‐phase extraction step. The validated method provided recoveries from 75 to 128% with intra‐ and interday precision lower than or equal to 24% (except for apoatropine). Limits of quantification ranged from 5 to 20 μg/kg. Eleven tea and herbal tea samples and two contaminated samples with Datura stramonium seeds were analyzed. Tropane alkaloids were detected in six samples with concentrations from 5 (apoatropine) to 4340 μg/kg (sum of physoperuvine, pseudotropine, and tropine), whereas concentrations from 5 (apoatropine) to 1725 μg/kg (sum of physoperuvine, pseudotropine, and tropine) were found in the contaminated samples.  相似文献   

12.
A rapid, convenient and reliable method for microextraction in packed syringe (MEPS) of the loop diuretic furosemide (FUR) in urine along with high-performance liquid chromatography (HPLC) was developed. A nanocomposite based on silver nanoparticles/polyaniline (Ag-NPs/PANI) was synthesized and used as the MEPS packing material. This nanocomposite was prepared conveniently using interfacial polymerization without the need for any templates or functional dopants. The feasibility of the synthesized nanocomposites was examined by isolation of FUR from diluted urine samples. After extraction, the analyte was desorbed by 200 μL of methanol. It was then dried and the residue was dissolved in 30 μL of methanol and an aliquot of 25 μL was, finally, injected into the HPLC system. Important parameters influencing the extraction and desorption processes were optimized and 25 cycles of draw–eject gave maximum peak area, when desorption was performed. The linearity was studied by preconcentration of 5 mL of diluted urine sample spiked with a standard solution of FUR in the concentration range of 15–750 μg L?1. The coefficient of determination was satisfactory (r 2 > 0.99) and the relative standard deviation (RSD %) value under the optimized condition was 8.8 %. The limit of detection and limit of quantification were 7 and 15 μg L?1, respectively.  相似文献   

13.
Laboratories intending to work as official laboratories for food control have to be accredited according to ISO/IEC 17025. This necessitates the use of validated analytical methods. In this study, we present validation results of the recently commercialized “JuiceScreener” based on nuclear magnetic resonance (NMR) spectroscopy with apple juice as application example. The quantitative analysis included 29 compounds such as major sugars, amino acids, organic acids, as well as acetoin, arbutin, benzaldehyde, hydroxymethylfurfural, acetaldehyde, methanol, and ethanol. Limit of detection (LOD), limit of quantification (LOQ), coefficients of variation (CV) for replicated measurements, repeatability, linear range, and recoveries were determined. The LOD and LOQ values varied in the 0.48–16 mg/L and in the 1.9–122 mg/L ranges with the lowest values for shikimic acid and highest for the principal sugars. The 1H NMR assays were linear in broad concentration ranges (R > 0.99), encompassed typical concentration in apple juices, and are sufficient to control the requirements of the code of practice of the European fruit juice association. Recoveries between 92 and 109 % on average for five separate standard additions were obtained. The average CVs were found to be 3.0 % (intraday) and 3.6 % (interday) excluding sample preparation (by measuring five time one solution) and 5.5 % (intraday) and 6.2 % (interday) including sample preparation (by preparing and analyzing five separate samples). The NMR method was judged as suitable for the simultaneous quantification of compounds in apple juice for official food control purposes. Our results show that multiparameter NMR methods can be successfully validated with standard instrumentarium and that they are fit for the purpose of official food control.  相似文献   

14.
We have developed a simple and sensitive method for the simultaneous determination of testosterone (TES), cortisol (CRT), and dehydroepiandrosterone (DHEA) in saliva by automated online in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS) using a Discovery HS F5 column. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample at a flow rate of 200 μL/min using a Supel-Q PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. The in-tube SPME LC–MS/MS method showed good linearity with correlation coefficients r?≥?0.9998 for TES, CRT, and DHEA using their respective stable isotope-labeled internal standards. The intra-day and inter-day precisions (relative standard deviations) were below 4.9 and 8.5 % (n?=?5), respectively. This method was successfully utilized to analyze TES, CRT, and DHEA in saliva samples without any other pretreatment or interference peaks, and the quantification limits (S/N?=?10) of TES, CRT and DHEA were about 0.01, 0.03 and 0.29 ng/mL saliva, respectively. The recoveries of these compounds spiked into saliva samples were each above 94 %. This method was applied to analyze changes in salivary TES, CRT, and DHEA levels resulting from stress and fatigue load.  相似文献   

15.
In this study, a generic extraction protocol and full-scan high-resolution Orbitrap-mass spectrometry (MS) detection method were developed, enabling the metabolomic screening for carotenoids in tomato fruit tissue. To this end, the carotenoids lutein, zeaxanthin, α-carotene, β-carotene, and lycopene (representing both xanthofylls and carotenes) were considered. The extraction procedure was optimized by means of a D-optimal design and consisted of a liquid–liquid extraction with methanol/tert-butyl methyl ether (1:1, v/v). The considered compounds were detected by a single-stage ExactiveTM mass spectrometer, operating at a mass resolution of 100,000 full width at half maximum. The validation study demonstrated excellent performance in terms of linearity (R 2?>?0.99), repeatability (CV?≤?10.6 %), within-laboratory reproducibility (CV?≤?12.2 %), and mean corrected recovery (ranging from 85 to 106 %). Additionally, a comparative evaluation towards well-established detection techniques, i.e., tandem mass spectrometry (MS/MS) and ultraviolet-visible spectroscopy (UV–VIS) photodiode array, indicated superior performance of high-resolution Orbitrap-MS with regard to specificity/selectivity and sensitivity (with limits of detection ranging from 1.0 to 3.8 pg μL?1). As a result, it may be concluded that high-resolution Orbitrap-MS is a suited alternative for UV–VIS or MS/MS in analyzing carotenoids and may offer significant value in carotenoid research because of the metabolomic screening possibilities.
Figure
Development and validation of a full-scan high-resolution Orbitrap-MS method for the analysis of carotenoids in tomato fruit tissue. Validation enclosed comparison with MS/MS and UV-VIS PDA  相似文献   

16.
Extracts from leaves and stems of Chenopodium hybridum were characterised for the presence and quantity of flavonoids and phenolic acids by LC-ESI-MS/MS. Five flavonoids and eight phenolic acids were detected for the first time in aerial parts of this plant species, the most abundant compounds being rutin (2.80 μg/g DW), 3-kaempferol rutinoside (2.91 μg/g DW), 4-OH-benzoic (1.86 μg/g DW) and syringic acids (2.31 μg/g DW). Extracts were tested for anti-inflammatory/antiarthritic, antihyaluronidase and cytotoxic activities against human prostate cancer (Du145, PC3) and melanoma cell lines (A375, HTB140 and WM793) of different malignancy. None of the extracts protected bovine serum albumin from heat-induced denaturation. Antihyaluronidase effect at the tested concentration was higher than standard naringenin. Cytotoxic activity was generally low with an exception of the extract from the leaves, which was found most effective against prostate Du145 cell line with 98.28 ± 1.13% of dead cells at 100 μg/mL.  相似文献   

17.
Two different rapid sample pretreatment strategies, dried spot cards, and microelution solid-phase extraction plates (μSPE), with ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) have been developed and validated for the determination of hydroxytyrosol and its metabolites in spiked human urine samples. Hydroxytyrosol, hydroxytyrosol-3′-O-glucuronide, hydroxytyrosol-4′-O-glucuronide, hydroxytyrosol-3-O-sulphate, and homovanillic alcohol-4′-O-glucuronide were used as the target compounds. Using the FTA DMPK-A dried urine spot card under optimum conditions, with 5 μL of preconcentrated urine volume and 100 μL of methanol/water (50/50, v/v) as the elution solvent, the extraction recovery (%R) of the compounds studied was higher than 80 %, and the matrix effect (%ME) was less than 8 %. The stability of these cards and punching at the centre or side of the card were also studied, obtaining an excellent stability after 7 days of storage and complete homogeneity across the surface of the dried drop. The different μSPE parameters that affect the efficiency were also studied, and under optimum conditions, the %R and the %ME were higher than 70 % and lower than 17 %, respectively. The linearity range in dried urine spot cards was 2.5-20 μM for all the metabolites, with the exception of hydroxytyrosol-3-O-sulphate and hydroxytyrosol, which were 0.3-70 μM and 2.5-50 μM respectively. With regards to μSPE, the linearity range was 0.5-5 μM for all the studied compounds, except for hydroxytyrosol-3-O-sulphate, which was 0.08-5 μM. The quantification limits (LOQs) were 0.3-2.5 μM and 0.08-0.5 μM in dried spot cards and in μSPE, respectively. The two developed methods were then applied and compared for determining hydroxytyrosol and its metabolites in human 24 h-urine samples after a sustained consumption (21 days) of a phenol-enriched virgin olive oil. The metabolites identified were hydroxytyrosol in its glucuronide and sulphate forms, homovanillic alcohol in its glucuronide and sulphate forms, homovanillic acid sulphate and hydroxytyrosol acetate sulphate.  相似文献   

18.
A simple and sensitive method for the determination of patulin in fruit juice and dried fruit samples was developed using a fully automated method consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–mass spectrometry (LC–MS). Patulin was separated within 5 min by high-performance liquid chromatography using a Synergi MAX-RP 80A column and water/acetonitrile (80/20, v/v) as the mobile phase. Electrospray ionization conditions in the negative ion mode were optimized for MS detection of patulin. The pseudo-molecular ion [M−H] was used to detect patulin in selected ion monitoring (SIM) mode. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample using a Carboxen 1006 PLOT capillary column as an extraction device. The extracted patulin was readily desorbed from the capillary by passage of the mobile phase, and no carry-over was observed. Using the in-tube SPME LC–MS with SIM method, good linearity of the calibration curve (r = 0.9996) was obtained in the concentration range of 0.5–20 ng/mL using 13C3-patulin as an internal standard, and the detection limit (S/N = 3) of patulin was 23.5 pg/mL. The in-tube SPME method showed >83-fold higher sensitivity than the direct injection method (10 μL injection volume). The within-day and between-day precision (relative standard deviations) were below 0.8% and 5.0% (n = 6), respectively. This method was applied successfully for the analysis of fruit juice and dried fruit samples without interference peaks. The recoveries of patulin spiked into apple juice were >92%, and the relative standard deviations were <4.5%. Patulin was detected at ng/mL levels in various commercial apple juice samples.  相似文献   

19.
An ultra performance liquid chromatography electrospray tandem mass spectrometry (UPLC/MS/MS) method was developed and validated for the determination of 17 antibiotics in natural waters in one single extraction and chromatographic procedure. Gradient separation conditions were optimised for 17 compounds belonging to five different antibiotic groups: quinolones (oxolinic acid, nalidixic acid, pipemidic acid, flumequine), fluoroquinolones (enoxacin, ciprofloxacin, norfloxacin, ofloxacin, enrofloxacin, sarafloxacin, danofloxacin, difloxacin, lomefloxacin), sulphonamides (sulphamethoxazole, sulphamethazine), nitro-imidazole (ornidazole) and diaminopyrimidine (trimethoprim). The separation of all compounds, obtained using a 1.7 μm particle size column (100 mm?×?2.1 mm), was achieved within 10 min time. Water samples were adjusted to pH 7 and extracted using Oasis hydrophilic–lipophilic balance (HLB) solid phase extraction cartridges. After elution with methanol and concentration, extracts were injected in a C18 column (Acquity UPLC BEH C18) and detected by tandem mass spectrometry. Average recovery from 100 ng L?1 fortified samples was higher than 70% for most of the compounds, with relative standard deviations below 20%. Performances of the method (recoveries, detection limit, quantification limit and relative standard deviation) and matrix effects were studied, and results obtained showed that method was suitable for routine analysis of antibiotics in surface water. Samples analysis from Seine River (France) confirmed the interest of antibiotic contamination evaluation in that area.
Fig. a
UPLC/MS/MS extracted ion chromatograms of a standard solution containing 17 analytes  相似文献   

20.
ABSTRACT

A method for the simultaneous determination of 30 pesticides residues in soil was developed and validated. Among the studied agrochemicals, there are herbicides (auxines, sulfonylureas, fops, imidazolinones), fungicides (azoles) and insecticides (organophosphorus) widely used in extensive agricultural activities in Uruguay. Five methods with different extraction times, type and amount of solvent, as well as the possibility of a clean-up step were compared in terms of percentage of recovery and repeatability. The final method was based on the extraction of the pesticides’ residues from soil using two successive solvent extraction steps. First, the soil was extracted with methanol in an orbital shaker for 4 h. Secondly, the solid residue was re-extracted overnight with ultrapure water. The methanolic extract was concentrated under vacuum, whereas the aqueous solution was passed through an OASIS HLB® cartridge, eluted with an appropriate solvent and concentrated under nitrogen stream. Both extracts were finally combined and analysed by LC-QQQ-MS/MS using the Document SANTE/11,945/2015 criteria. Recovery percentages at 1 and 10 μg kg?1 for the studied compounds were in the range 70106% with relative standard deviations below 19 %. The quantification was performed using matrix-matched calibration curves as some compounds presented very strong signal suppression. Residuals of the matrix-matched calibration curves were below 20% for all the validated analytes. The quantification limit was1 μg kg?1. The method also allows the screening of 11 pesticides in soil. Sixty-five real samples collected from regions where the use of pesticides is intensive were analysed. Quinclorac, tebuconazole, penoxsulam and clomazone were the most frequently pesticides detected.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏