首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
It is shown that toxicant MX can be reliably identified and determined quantitatively by ion-trap tandem mass spectrometry with an accuracy as high as that for high-resolution mass spectrometry.  相似文献   

2.
The organometallic ions V+-(benzene) and V+-(benzene)2 are produced by laser vaporization in a pulsed nozzle source. They are trapped and mass selected in an ion-trap/time-of-flight mass spectrometer, and their infrared spectra are measured with resonance-enhanced multiphoton photodissociation (IR-REMPD) spectroscopy with a tunable free-electron laser. Vibrational bands in the 600-1800 cm-1 region are characteristic of the benzene molecular moiety perturbed by the metal cation bonding. Experimental data are compared to the IR spectra derived from density functional calculations. Vibrational patterns in V+-(C6H6) indicate that the metal is bound in an eta6 pi-bonding configuration, while V+-(C6H6)2 is a sandwich. Trapped-ion IR-REMPD is a general method to access the vibrational spectroscopy of organometallic ions and their clusters.  相似文献   

3.
As an effective DPP-IV inhibitor, 2-(4-((2-(2S,5R)-2-Cyano-5-ethynyl-1-pyrrolidinyl)-2-oxoethylamino)-4-methyl-1-piperidinyl)-4-pyridinecarboxylic acid (ABT-279), is an investigational drug candidate under development at Abbott Laboratories for potential treatment of type 2 diabetes. In order to support the development of ABT-279, multiple analytical methods for an accurate, precise and selective concentration determination of ABT-279 in different matrices were developed and validated in accordance with the US Food and Drug Administration Guidance on Bioanalytical Method Validation. The analytical method for ABT-279 in dog plasma was validated in parallel to other validations for ABT-279 determination in different matrices. In order to shorten the sample preparation time and increase method precision, an automated multi-channel liquid handler was used to perform high-throughput protein precipitation and all other liquid transfers. The separation was performed through a Waters YMC ODS-AQ column (2.0 x 150 mm, 5 microm, 120 A) with a mobile phase of 20 mm ammonium acetate in 20% acetonitrile at a flow rate of 0.3 mL/min. Data collection started at 2.2 min and continued for 2.0 min. The validated linear dynamic range in dog plasma was between 3.05 and 2033.64 ng/mL using a 50 microL sample volume. The achieved r(2) coefficient of determination from three consecutive runs was between 0.998625 and 0.999085. The mean bias was between -4.1 and 4.3% for all calibration standards including lower limit of quantitation. The mean bias was between -8.0 and 0.4% for the quality control samples. The precision, expressed as a coefficient of variation (CV), was < or =4.1% for all levels of quality control samples. The validation results demonstrated that the high-throughput method was accurate, precise and selective for the determination of ABT-279 in dog plasma. The validated method was also employed to support two toxicology studies. The passing rate was 100% for all 49 runs from one validation study and two toxicology studies.  相似文献   

4.
A new sensitive and highly selective method is described for the spectrophotometric determination of microgram amounts of vanadium(V). First, vanadium is isolated by extraction withN-benzoyl-N-phenylhydroxylamine (BPHA) in chloroform from about 4M hydrochloric acid medium. Then, chloroform is evaporated and the residue mineralized with mixture of cone. perchloric and nitric acid. Finally, a colour reaction of vanadium(V) separated with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) in an acetate buffer (pH 4.5) gives a molar absorptivity of 5.48×104l·mol–1·cm–1 at 585 nm. The proposed method was applied for the determination of traces of vanadium in aluminium samples. The results obtained show a good precision and accuracy of the method.  相似文献   

5.
Tsai JL  Wu WS  Lee HH 《Electrophoresis》2000,21(8):1580-1586
A rapid, sensitive method for the determination of morphine and amphetamine was developed using capillary zone electrophoresis coupled with electrospray interface (ESI), ion-trap tandem mass spectrometry (CE-ESI-MS2). Morphine and amphetamine were separated in 20 mM ammonium acetate buffer (pH 6.6) and detected by ion-trap mass detector in different analytical time segments (0-6.25 min for amphetamine and 6.25-12.0 min for morphine) in which the tune file for each compound was used separately. Molecular ions of morphine (m/z 286) and amphetamine (m/z 136) were detected at 5.77 and 6.83 min, respectively, while product ions of MS2 for each compound (m/z 229, 201 for morphine and m/z 119 for amphetamine) were detected almost exactly at the same time with their parent compounds. The limits of detection (LOD) for MS2 determination were 30 and 50 ng/mL for amphetamine and morphine, respectively, with an S/N ratio of 3. For more sensitive detection of morphine, the sample was injected for a longer time (i.e., 80 s) and hydrodynamically transported into a CE capillary for MS detection. Morphine and its product ion appear at 0.36 and 0.39 min on the ion chromatogram, respectively, with a five-fold increase of detection sensitivity (LOD, 10 ng/mL). The CE-MS system thus established was further applied for forensic urine samples screened as morphine-positive by fluorescence polarization immunoassay (FPIA). These results indicated the feasibility of CE-ESI-MS2 for confirmative testing of morphine in urine sample.  相似文献   

6.
Summary An ion-trap mass spectrometer for determination of quaternary ammonium herbicides in water samples is evaluated. Implementation of the method previously optimized in a quadrupole mass spectrometer (VG Platform II) in an ion-trap (LCQ) required modifications to the sample inlet of the electrospray source. Quality parameters were established and detection limits, after trace enrichment, range 5–50 ng L−1. Good reproducibilities (day-to-day and run-to-run) <12% were obtained. The method was applied to analysis of spiked samples and the results were comparable with those determined using a quadrupole mass spectrometer.  相似文献   

7.
A selective and sensitive analytical method was developed for enantiomeric separation and determination of N‐methyl‐DL‐aspartic acid (NMA). The method involved the conversion of each enantiomer into N‐ethoxycarbonylated (S)‐(+)‐2‐octyl ester derivative for the direct separation by gas chromatography–mass spectrometry (GC‐MS). The diastereomeric derivatives showed characteristic mass spectral properties for analysis by selected ion monitoring mode (SIM) and enabling enantioseparation on an achiral capillary column. Two enantiomers were baseline separated, and the detection limits for N‐methyl‐L‐aspartic acid (NMLA) and N‐methyl‐D‐aspartic acid (NMDA) were 0.07 and 0.03 ng/g, respectively. When applied to rat brain tissues for absolute configuration of NMA, only NMDA was determined, while NMLA was monitored as lower than the limit of detection. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
The abuse of nortestosterone in sport is an important problem in doping-control analysis. In order to detect the main urinary metabolite of nortestosterone, norandrosterone (NA), sensitive and specific methodology is necessary. In this context the use of a low-cost mass spectrometric detector such as the Finnigan MAT ion-trap detector (ITD) was studied. The electron ionization (EI) and positive-ion chemical ionization (PICI) mass spectra of the methoxime-trimethylsilyl, trimethylsilyl-enol trimethylsilyl ether and pentafluoropropionic ester derivatives of NA are described. The limits of detection of these derivatives are compared with those obtained by the Hewlett-Packard mass selective detector (MSD), another low-cost mass spectrometric detector and operating only in the EI mode. For the derivatives of the reference standard of NA the ITD has in the EI mode the same limit of detection, in the range of 0.5 to 1 ng injected on the column, as the MSD. However, under these conditions the ITD provides more spectrometric information, because it gives full scan data. Moreover, with the same or even improved limits of detection the ITD can operate in the PICI mode. On the other hand, for the analysis of NA isolated from urine samples, the performance of the MSD was better than that of the ITD. The ion trapping technique is probably limited when the chemical background is high.  相似文献   

9.
Multiresidue analysis for organophosphates in organic oranges grown in Calabria (Italy) is performed by the combined use of a pulsed flame photometric detector and an ion-trap mass spectrometer simultaneously coupled to a gas chromatograph through a double-hole ferrule. The method provides the retention times (RTs) of the phosphorus-containing analytes only. The extracted ion chromatograms at the previously determined RTs are used for full identification of the species through a mass spectra library search and for quantitative evaluation of each species in the natural matrix. The banned pesticide ronnel was used as an internal standard because of its chemical structure, which is perfectly suited to the performance of both detectors.  相似文献   

10.
Selected tandem mass spectrometry (MS/MS) ion monitoring (SMIM) is the most suitable scanning mode to detect known peptides in complex samples when an ion-trap mass spectrometer is the instrument used for the analysis. In this mode, the MS detector is programmed to perform continuous MS/MS scans on one or more selected precursors, either during a selected time interval, or along the whole chromatographic run. MS/MS spectra are recorded, so virtual multiple reaction monitoring chromatogram traces for the different fragment ions can be plotted. In this work, a shotgun proteomics approach was applied to the detection of previously characterized species-specific peptides from different seafood species. The proposed methodology makes use of high intensity focused ultrasound-assisted trypsin digestion for ultra fast sample preparation, peptide separation and identification by reverse phase capillary LC coupled to an ion-trap working in the SMIM scanning mode. This methodology was applied to the differential classification of seven commercial, closely related, species of Decapoda shrimps proving to be an excellent tool for seafood product authentication, which may be used by fisheries and manufacturers to provide a fast and effective identification of the specimens, guaranteeing the quality and safety of foodstuffs to consumers.  相似文献   

11.
Deethylatrazine (DEA), an atrazine degradation product, has been added to the US Environmental Protection Agency's Drinking Water Contaminant Candidate List (CCL). In its gas chromatographic analysis, DEA can coelute with deisopropylatrazine (DIA), another degradation product. The present work demonstrates that the coelution of DEA and DIA can induce a significant (up to approximately 50%) positive bias in the DEA determination, when using an ion-trap mass spectrometer as the detector. The DIA determination is unaffected by the coelution within experimental error. This may be explained in terms of gas-phase ion fragment populations. A correction factor to the observed DEA concentration may be developed based on the measured DIA concentration.  相似文献   

12.
Irinotecan or 7-ethyl-10-[4-(1-piperidino)-1-piperidino]carbonyloxycamptothecin (CPT-11) is an anticancer pro-drug used in the treatment of many types of cancer. We describe here the validation of an analytical method for CPT-11 and its metabolites, including an active metabolite, 7-ethyl-10-hydroxycamptothecin (SN-38), its glucuronidated form, SN-38G, and several cytochrome P450 3A-mediated products such as 7-ethyl-10-[4-N-(5-aminopentanoic acid)-1-piperidino]carbonyloxycamptothecin (APC) using a high-performance liquid chromatography connected to parallel fluorescence and mass spectrometry detection systems. This method is characterized as follows: (1) simple extraction of the analytes from biomaterials with perchloric acid/methanol; (2) sensitive quantitation of major metabolites (SN-38G, SN-38 and APC) with a fluorescence detector (FLD), where the limits of quantitation by FLD were 2.5 ng/mL for SN-38G and APC, 5 ng/mL for CPT-11 and 1 ng/mL for SN-38, respectively; (3) parallel selective monitoring of the metabolites including minor metabolites with a mass selected detector (MSD). There was no observed interference by other drugs expected to be co-administered. This method showed its usefulness by identifying a novel metabolite produced in human hepatic microsomes. The results indicate that this combination of FLD and MSD enables a highly selective analysis of CPT-11 and its metabolites, and is useful for studies both in vivo and in vitro.  相似文献   

13.
Tannins from sorghum grains with high and low tannin content, from grape skins and seeds and from apple pomace were analysed by pyrolysis/gas chromatography/ion-trap detector mass spectrometry. Pyrolysis at 600°C produced catechol as a characteristic fragment of condensed tannins, and other phenolic compounds related to the lignified tissues. Catechol was also the main fragment in the pyrogram of catechin, a monomeric constituent of condensed tannins. Mass spectral data and relative quantifications of the pyrograms of several samples are provided. Quantitative data are discussed in terms of reproducibility and linearity of response and are compared with the results of a spectrophotometric assay for tannins.  相似文献   

14.
施介华  徐秀珠 《分析化学》1998,26(12):1481-1484
采用在硅胶柱(ZORBAX SIL)上,以正己烷:乙酸=70:30:2.5为流动相及UV检测器(254nm)的高效液相色谱法分离和测定2-(4-羟基苯氧基)丙酸。在选定的色谱操作条例上,2-(4-羟基苯氧基)丙酸与杂质对苯二酚等之间具有良好的分离效果。该方法具有较好的重现性和准确性。  相似文献   

15.
Fu-Sheng W  Pei-Hua Q  Nai-Kui S  Fang Y 《Talanta》1981,28(3):189-191
A simple, selective and highly sensitive procedure for spectrophotometric determination of nickel has been developed. At pH 5.5, nickel reacts with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol in water-ethanol medium to form a red-violet complex which has two absorption maxima, at 520 and 56Onm. The molar absorptivity at 56Onm is 1.26 x 10(5) l.mole(-1).cm(-1). Beer's law is obeyed for 0-15 mug of nickel. Nickel in aluminium alloys and electroplating waste-water has been determined by this method.  相似文献   

16.
A specific and sensitive procedure for the determination of prenazone at therapeutic levels in human plasma has been developed. The method involves extraction of the drug from acidified plasma into chloroform. After further purification by back extraction the residue is examined on a gas-liquid chromatograph fitted with a flame ionisation detector. Tetraphenylethylene is used as an internal standard for quantitation by the relative peak height technique. Plasma levels encountered after oral ingestion of therapeutic doses are reported.  相似文献   

17.
Inasearchfornewsensitiveandselectiveorganicreagents,athoroughstudyofsomeofthequinolylazo,pyridylazocompoundshasbeenreported'-'.Buttriazolylazocompoundshavenotbeenstudied.Inthispapef,2-(l,3,4-triazolylazo)-5-diethyIaminophenol(TZAPN)and2-(5-carboxy-l,3,4-triazoiylazo)-diethyIaminophenoI(CTZAPN)wereprepared,theconditionsofthisreactionwithcobaltwerestudied.Itwasfoundthatthereagentshadhighsensitivityandselectivityinthedeterminationofmicrogramamountsofcobaltundertheconditionsestablished.Thest…  相似文献   

18.
An analytical method has been developed for the determination of residues of ethephon (2-chloroethyl phosphonic acid) in drinking and surface water. The procedure is based on de-ionisation with an anion/cation-exchange resin, solid phase extraction by means of anion-exchange polystyrene-divinylbenzene extraction disks, elution with a mixture of methanol and 10 M hydrochloric acid (98/2, v/v), redisolution into acetonitrile after evaporation and silylation with N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA). Quantification is performed by gas chromatography with ion-trap cubic mass spectrometric detection in the electron impact mode (GC-EI-MS3). Method validation was conducted using samples of mineral, tap, and river water that were fortified with ethephon at concentration levels ranging from 0.1 to 1.0 microg/L. The mean recovery from all the fortified samples (n = 36) amounted to 88% with a relative standard deviation of 17%. The method, therefore, was shown to allow accurate determination of ethephon residues in drinking and surface water with a limit of quantification of 0.1 microg/L.  相似文献   

19.
A simple method for the determination of uranium in process- and waste-stream samples at a nuclear fuel reprocessing facility that can be applied entirely in a remote environment is described. The method is both sensitive and selective enough to be applicable for almost any uranium determination. Uranium in aqueous samples is extracted as a nitrate complex into 4-methylpentan-2-one (hexone) from an acid-deficient aluminium nitrate salting solution. An aliquot of the hexone extract is then mixed with a solution containing methanol, pyridine and 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Br-PADAP). The absorbance of the U(VI)-Br- PADAP complex is measured at 580 nm. The detection limit for uranium is 0.8 μg with the linear range extending to 80 μg. Interference studies, modifications for organic samples and solid-containing samples and process laboratory data are presented.  相似文献   

20.
A method for the assay of 1,3,3,5,5-pentakis-(azaridino)-lambda 6,2,4,6,3 lambda 5,5 lambda 5-thiatriazadiphosphorine-1-oxide (SOAz), a new anticancer drug of which the clinical trials are in progress, is described. This method is based on capillary gas chromatography using a thermionic detector. The lower detection limit was 100 pg per injection and a coefficient of variation smaller than 5% could be obtained when parathion was used as external standard. The method is suitable for biological samples and therefore has been proposed for clinical pharmacokinetic studies as well as for the determination of patterns of SOAz distribution in several organs of the mouse. A preliminary clinical study showed that the serum decay curves of SOAz could be fitted to an open two-compartment model for drug disappearance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号