首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
New enrichment protocols are described for use with a DNA hybridization (DNAH) method for detection of Salmonella spp. in select foods. GeneQuence Salmonella, in its original version, utilized a 3-stage enrichment of minimum 42 h duration. New 2-stage procedures of 24-28 h duration are described for raw poultry, raw beef, pasteurized egg products, milk chocolate, and dry pet food. In the validation study described here, a total of 345 samples were tested by the abbreviated DNAH method in parallel with either the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM) or U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedures. Results showed an overall sensitivity for the DNAH method of 97.1% (false-negative rate 2.9%). There were no false-positive results by the DNAH method; therefore the specificity was 100%. Overall agreement between the DNAH and reference culture methods was 98.5%. There were no significant differences in performance between the DNAH and reference methods for any of the foods tested as determined by Chi-square analysis. It is recommended that the DNAH method be subjected to AOAC collaborative study.  相似文献   

2.
Singlepath Salmonella is an immunochromatographic (lateral flow) assay for the presumptive qualitative detection of Salmonella spp. in food. The AOAC Performance-Tested Method study evaluated Singlepath Salmonella as an effective method for the detection of Salmonella spp. in the following selected foods: dried skimmed milk, black pepper, dried pet food, desiccated coconut, cooked peeled frozen prawns, raw ground beef, and raw ground turkey. When the foods were inoculated with Salmonella spp. at levels ranging from low [0.23-1.08 colony forming units (CFU)/25 g] to high (2.3-6.0 CFU/25 g), a Chi-square value of 0.9 indicated that there was no significant difference between Singlepath Salmonella and the ISO 6579:2002 reference method. Singlepath Salmonella gave a false-positive rate of 7.3% and a false-negative rate of 2.5%. For the inclusivity study, all 105 Salmonella serovars reacted with Singlepath Salmonella. For the exclusivity study, 58 non-Salmonella spp. were tested. There were no cross-reactions with Singlepath Salmonella from these strains.  相似文献   

3.
A collaborative study was conducted to compare the VIDAS Salmonella (SLM) with Rappaport-Vassiliadis (RV) method for detection of Salmonella in foods to the current standard method presented in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) and the culture method presented in AOAC's Official Methods of Analysis. The VIDAS SLM with RV method uses tetrathionate broth in combination with RV medium in place of selenite cystine broth for selective enrichment, thereby eliminating the hazardous waste issue for laboratories. Twenty five laboratories participated in the evaluation, each testing one or more of 8 test products: nonfat dry milk, dried egg, soy flour, lactic casein, milk chocolate, raw ground pork, raw ground turkey, and raw peeled shrimp. Results of the study showed no significant differences in the numbers of confirmed positive samples with the VIDAS SLM with RV procedure and the BAM/AOAC culture procedure. The VIDAS SLM with RV method was effective for rapid detection of Salmonella in foods. It is recommended that AOAC INTERNATIONAL modify the VIDAS Salmonella SLM procedure to include the RV method.  相似文献   

4.
A collaborative study was conducted to compare a new enrichment procedure for the TECRA Salmonella Visual Immunoassay with the reference method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM 7th Ed.). Three food types (milk powder, black pepper, and soy flour) were analyzed in Australia, and 3 food types (milk chocolate, dried egg, and raw turkey) were analyzed in the United States. Thirty-eight collaborators participated in the study. No significant differences (p > 0.05) were observed for the pairwise comparison of the proportion of positive samples for the TECRA method with that for the reference method. The new enrichment procedure for the TECRA method has been adopted First Action by AOAC INTERNATIONAL.  相似文献   

5.
Reveal Salmonella 2.0 is an improved version of the original Reveal Salmonella lateral flow immunoassay and is applicable to the detection of Salmonella enterica serogroups A-E in a variety of food and environmental samples. A Performance Tested Method validation study was conducted to compare performance of the Reveal 2.0 method with that of the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods for detection of Salmonella spp. in chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, raw shrimp, a ready-to-eat meal product, dry pet food, ice cream, spinach, cantaloupe, peanut butter, stainless steel surface, and sprout irrigation water. In a total of 17 trials performed internally and four trials performed in an independent laboratory, there were no statistically significant differences in performance of the Reveal 2.0 and reference culture procedures as determined by Chi-square analysis, with the exception of one trial with stainless steel surface and one trial with sprout irrigation water where there were significantly more positive results by the Reveal 2.0 method. Considering all data generated in testing food samples using enrichment procedures specifically designed for the Reveal method, overall sensitivity of the Reveal method relative to the reference culture methods was 99%. In testing environmental samples, sensitivity of the Reveal method relative to the reference culture method was 164%. For select foods, use of the Reveal test in conjunction with reference method enrichment resulted in overall sensitivity of 92%. There were no unconfirmed positive results on uninoculated control samples in any trials for specificity of 100%. In inclusivity testing, 102 different Salmonella serovars belonging to serogroups A-E were tested and 99 were consistently positive in the Reveal test. In exclusivity testing of 33 strains of non-salmonellae representing 14 genera, 32 were negative when tested with Reveal following nonselective enrichment, and the remaining strain was found to be substantially inhibited by the enrichment media used with the Reveal method. Results of ruggedness testing showed that the Reveal test produces accurate results even with substantial deviation in sample volume or device development time.  相似文献   

6.
Real-time PCR methods for detecting foodborne pathogens offer the advantages of simplicity and quick time-to-results compared to traditional culture methods. In this study, the MicroSEQ real-time PCR system was evaluated for detection of Salmonella spp. in 10 different food matrixes following the AOAC Research Institute's Performance Tested Method validation program. In addition, the performance of the MicroSEQ system was evaluated for the detection of Salmonella in peanut butter as a part of the Emergency Response Validation Program sponsored by the AOAC Research Institute. The system was compared to the ISO 6579 reference method using a paired-study design for detecting Salmonella spp. in raw ground beef, raw chicken, raw shrimp, Brie cheese, shell eggs, cantaloupe, chocolate, black pepper, dry infant formula, and dry pet food. For the peanut butter study, the system was compared to the U.S. Food and Drug Administration's Bacteriological Analytical Manual procedures using an unpaired-study design. No significant difference in performance was observed between the MicroSEQ Salmonella spp. detection system and the corresponding reference methods for all 11 food matrixes. The MicroSEQ system detected all Salmonella strains tested, while showing good discrimination against detection of an exclusivity panel of 30 strains, with high accuracy.  相似文献   

7.
The VIDAS Immuno-concentration Salmonella ICS)/VIDAS Salmonella (SLM) immunoassay method for the detection of Salmonella was compared to the Bacteriological Analytical Manual (BAM)/AOAC culture method in a collaborative study. Thirty-two laboratories participated in the evaluation. Each laboratory tested one or more of the 6 test products: milk chocolate, nonfat dry milk, dried whole egg, soy flour, ground black pepper, and ground raw turkey. The 2 methods were in agreement for 1,266 of the 1,440 samples. Of the 174 samples not in agreement, 69 were VIDAS CS/SLM-positive and BAM/AOAC-negative and 105 were VIDAS ICS/SLM-negative and BAM/AOAC-positive.  相似文献   

8.
The VIDAS Immuno-concentration Salmonella (ICS) plus selective plate method (Hektoen enteric, bismuth sulfite, Salmonella identification) method for the detection of Salmonella was compared to the Bacteriological Analytical Manual (BAM)/AOAC culture method in a collaborative study. Thirty-two laboratories participated in the evaluation. Each laboratory tested one or more of the 6 test products: milk chocolate, nonfat dry milk, dried whole egg, soy flour, ground black pepper, and ground raw turkey. The 2 methods were in agreement for 1,283 of the 1,440 test samples. Of the 157 test samples not in agreement, 82 were VIDAS ICS plus selective plate-positive and BAM/AOAC-negative, and 75 were VIDAS ICS plus selective plate-negative and BAM/AOAC-positive.  相似文献   

9.
The VIDAS Immuno-concentration Salmonella (ICS) plus selective plate method (Hektoen enteric, xylose lysine desoxycholate, bismuth sulfite) method for the detection of Salmonella was compared to the Bacteriological Analytical Manual (BAM)/AOAC culture method in a collaborative study. Thirty-two laboratories participated in the evaluation. Each laboratory tested one or more of the 6 test products: milk chocolate, nonfat dry milk, dried whole egg, soy flour, ground black pepper, and ground raw turkey. The 2 methods were in agreement for 1,297 of the 1,455 samples. Of the 158 samples not in agreement, 82 were VIDAS ICS plus selective plate-positive and BAM/AOAC-negative, and 76 were VIDAS ICS plus selective plate-negative and BAM/AOAC-positive.  相似文献   

10.
A collaborative study was conducted to compare a new enrichment procedure for the TECRA Salmonella Visual Immunoassay (TSVIA) with the reference method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (7th Ed.). Three food types (milk powder, pepper, and soy flour) were analyzed in Australia and 3 food types (milk chocolate, dried egg, and raw turkey) were analyzed in the United States. Thirty-eight collaborators participated in the study. The TECRA method was evaluated using both Rappaport-Vassiliadis R10 (RV(R10)) and tetrathionate (TT) broths for selective enrichment. M broth cultures arising from each of the 2 selective enrichment broths were tested in the TSVIA using 2 individual wells, one for each selective broth, and a single well to test the pooled selective enrichment broths. The results for the pooled enrichment broths were reported elsewhere. This study presents the results for the use of single enrichment broths, i.e., RV(R10) only or TT only, with the TSVIA. No significant differences (p > 0.05) were observed for the pairwise comparison of the proportion of positive samples for either RV(R10) or TT used as a single enrichment broth for the TSVIA with that for the reference method.  相似文献   

11.
A rehydratable dry-film plating method for Staphylococcus aureus in foods, the 3M Petrifilm Rapid S. aureus Count Plate method, was compared with AOAC Official Method 975.55 (Staphylococcus aureus in Foods). Nine foods-instant nonfat dried milk, dry seasoned vegetable coating, frozen hash browns, frozen cooked chicken patty, frozen ground raw pork, shredded cheddar cheese, fresh green beans, pasta filled with beef and cheese, and egg custard-were analyzed for S. aureus by 13 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample and 3 levels of inoculated test sample, each in duplicate. The mean log counts for the methods were comparable for pasta filled with beef and cheese; frozen hash browns; cooked chicken patty; egg custard; frozen ground raw pork; and instant nonfat dried milk. The repeatability and reproducibility variances of the Petrifilm Rapid S. aureus Count Plate method were similar to those of the standard method.  相似文献   

12.
The TECRA Unique Salmonella test uses the principle of immunoenrichment to allow rapid detection of Salmonellae in food. A collaborative study was conducted to compare the TECRA Salmonella Unique test with the reference culture method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual. Three food types (milk powder, pepper, and soy flour) were analyzed in Australia and 2 food types (milk chocolate and dried egg) were analyzed in the United States. Forty-one collaborators participated in the study. For each of the 5 foods at each of the 3 levels, a comparison showed no significant differences (p > or = 0.05) in the proportion of positive test samples for Unique and that for the reference method using the Chi-square test for independence with continuity correction.  相似文献   

13.
A collaborative study was conducted to validate new enrichment methods for the TECRA Listeria Visual Immunoassay (TLVIA). These new methods incorporate a newly formulated medium, TECRA Listeria Enrichrment Broth, which does not contain the highly toxic antifungal agent, cycloheximide. The new procedures will provide an alternative to the enrichment procedures described in AOAC Method 995.22. Three food types (raw ground beef, lettuce, and ice cream) were analyzed in the United States, and 2 food types (cooked turkey and cooked fish fillets) were analyzed in Australasia. Thirty collaborators participated in the study, 16 in Australasia and 14 in the United States. With the exception of one batch of ground beef, comparison of the proportion of positive test portions (p > or = 0.05) showed no significant difference between the TLVIA and the reference method for the 5 foods at 3 inoculation levels. For the one batch of naturally contaminated raw ground beef, the TLVIA gave significantly more confirmed positive results than the reference method.  相似文献   

14.
RAPID'E. coli 2 agar (Bio-Rad Laboratories, Hercules, CA) is a chromogenic medium for differentiation and enumeration of E. coli and non-E. coli coliform bacteria in food. The principle of RAPID'E. coli 2 medium relies on simultaneous detection of 2 enzymatic activities, P-D-glucuronidase (GLUC) and beta-D-galactosidase (GAL). Coliforms, other than E. coli (GAL+/GLUC-), form blue to green colonies, whereas, specifically, E. coli (GAL+/GLUC+) form violet colonies. Eleven foods (raw ground beef, raw boneless pork, fermented sausage, processed ham, processed turkey, frozen turkey breast, raw ground chicken, cottage cheese, ricotta cheese, raw milk, and dry infant formula) were validated, comparing the performance of RAPID'E. coli 2 agar to the reference method AOAC 966.24. Two sample incubation temperatures were evaluated, 37 and 44 degrees C, testing a mixture of naturally and artificially contaminated foods. If naturally contaminated food was not available, the matrix was artificially inoculated with one E. coli strain and one non-E. coli coliform strain. Method comparison studies demonstrated some statistical differences between the 2 methods, which are expected when a plating method is compared to a most probable number method. Inclusivity and exclusivity rates of the medium were 99 and 94%, respectively. The RAPID'E. coli 2 method was shown to be stable when minor variations were introduced.  相似文献   

15.
In a multilaboratory study, the effectiveness of an alternative method for rapid screening of Listeria species compared to traditional reference methods was demonstrated in a variety of food products. A collaborative study was conducted to compare the VIDAS Listeria species Xpress (LSX) method and the standard cultural methods for the detection of Listeria species in foods. Six food types were tested: vanilla ice cream, cheddar cheese, raw ground beef, frozen green beans, deli turkey, and cooked shrimp. Each food, inoculated with a different Listeria strain at two levels and uninoculated test portions, was analyzed by each method. A total of 15 laboratories representing government and industry participated. In this study 1134 tests were analyzed in the statistical analysis. There were 490 positives by the VIDAS LSX method using the sample boiling step, 483 positives by the VIDAS LSX method using the Heat and Go system, and 439 positives by the standard culture methods. Overall, the Chi-square result for the VIDAS LSX method with boiling for all foods was 7.25, indicating a significant statistical difference between the VIDAS method and the standard methods at the 5% confidence. For the VIDAS LSX method with the Heat and Go system, the Chi-square result for all foods was 5.37, indicating a significant statistical difference between the VIDAS LSX assay with the Heat and Go system and the standard methods at the 5% level of significance. In both cases, the VIDAS method was more sensitive than the standard methods. The LSX method detects Listeria species in foods with negative or presumptive positive results in a minimum of 30 h compared to at least 5 days for the cultural methods. Based on the results of this collaborative study, it is recommended that the VIDAS LSX method be adopted as an AOAC Official Method for the detection of Listeria species in dairy products, vegetables, seafood, raw meats and poultry, and processed meats and poultry.  相似文献   

16.
The VIDAS Salmonella (SLM) Easy Salmonella method is a specific enzyme-linked fluorescent immunoassay performed in the automated VIDAS instrument. The VIDAS Easy Salmonella method is a simple 2-step enrichment procedure, using pre-enrichment followed by selective enrichment in a newly formulated broth, SX2 broth. This new method was compared in a multilaboratory collaborative study to the U.S. Food and Drug Administration's Bacteriological Analytical Manual, Chapter 5 method for five food matrixes (liquid egg, vanilla ice cream, spinach, raw shrimp, and peanut butter) and the U.S. Department of Agriculture's Microbiology Laboratory Guidebook 4.04 method for deli turkey. Each food type was artificially contaminated with Salmonella at three inoculation levels. A total of 15 laboratories representing government, academia, and industry, throughout the United States, participated. In this study, 1583 samples were analyzed, of which 792 were paired replicates and 791 were unpaired replicates. Of the 792 paired replicates, 285 were positive by both the VIDAS and reference methods. Of the 791 unpaired replicates, 341 were positive by the VIDAS method and 325 were positive by the cultural reference method. A Chi-square analysis of each of the six food types was performed at the three inoculation levels tested. For all foods evaluated, the VIDAS Easy SLM method demonstrated results comparable to those of the reference methods for the detection of Salmonella.  相似文献   

17.
A multilaboratory study was conducted to compare the automated BAX System to the standard cultural methods for detection of Salmonella in selected foods. Five food types--frankfurters, raw ground beef, mozzarella cheese, raw frozen tilapia fish, and orange juice--at 3 inoculation levels, were analyzed by each method. A sixth food type, raw ground chicken, was tested using 3 naturally contaminated lots. A total of 16 laboratories representing government and industry participated. In this study, 1386 samples were analyzed, of which 1188 were paired samples and 198 were unpaired samples. Of the 1188 paired samples, 461 were positive by both methods and 404 were negative by both methods. Thirty-seven samples were positive by the BAX System but negative by the standard reference method, and 11 samples were positive by standard cultural method and negative by the BAX System. Of the 198 unpaired samples, 106 were positive by the BAX System and 60 were positive by the standard cultural method. A Chi square analysis of each of the 6 food types, at the 3 inoculation levels tested, was performed. For all foods, the BAX System demonstrated results comparable to those of the standard reference methods based on the Chi square results.  相似文献   

18.
Egg is one of the 5 major allergenic foods that are responsible for more than 3/4 of food allergies in children. Food-allergic responses can be controlled by avoidance of the offending foods. The applicability of a commercial enzyme-linked immunosorbent assay (ELISA) kit for the detection of egg in food products such as cookies, crackers, pretzels, salad dressings, and raw and cooked noodles was evaluated. A preliminary evaluation of an antibody-based biosensor was also performed. A National Institute of Standards and Technology (NIST) whole dried egg powder reference material, SRM 8415, was used as a standard. A homogeneous and stable aqueous egg suspension was prepared for the evaluation of the performance of the Veratox for Egg Allergen Test (Neogen Corp., Lansing, MI). This test does not detect egg yolk proteins. Each gram of the aqueous dried egg suspension contained 643 microg whole dried egg, 0.5 mg thimerosal, and 2.5 mg bovine serum albumin. When cookies, crackers, salad dressings, noodles, and ice cream were spiked at a level of 24 mg/kg SRM 8415, recoveries for whole egg averaged about 28%. All foods containing egg as indicated on the ingredient label were found positive by the Veratox test. No false positives occurred in samples that did not contain eggs. Similar results were obtained using the Naval Research Laboratory (NRL) array biosensor, an evanescent wave fluoroimmunosensor. Results for cooked noodles showed that they contained <1% of the egg found in uncooked noodles. A comparison of extracts from cooked and uncooked noodles by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) revealed differences in protein profiles. The boiling of the noodles could have reduced the immunoreactivity of the egg proteins to the antibodies used in the kit or rendered the egg proteins nonextractable.  相似文献   

19.
Six foods representative of a wide variety of processed, dried powder processed, and raw food types were analyzed by the Visual Immunoprecipitate Assay (VIP) for Salmonella and AOAC INTERNATIONAL culture method. Paired samples of each food type were simultaneously analyzed; one sample by the VIP method and one by the AOAC culture method. A total of 24 laboratories representing federal government agencies and private industry, in the United States and Canada, participated in this collaborative study. Food types were inoculated with species of Salmonella with the exception of raw ground chicken, which was naturally contaminated. No statistical differences (p < 0.05) were observed between VIP for Salmonella interpretation and the AOAC culture method for any inoculation level of any food type or naturally contaminated food. The method was adopted Official First Action status by AOAC INTERNATIONAL.  相似文献   

20.
The Sanita-kun Coliforms consists of a transparent cover film, an adhesive sheet, a layer of nonwoven fabric, and a water-soluble compound film, including a culture medium formula for the detection of coliforms. The medium sheet was validated with 26 food types belonging to 9 food categories (meat, poultry, fish and seafood, fruits and vegetable, dairy, chocolate or bakery, animal feeds, pasta, and miscellaneous) using violet red bile (VRB) agar method in the U.S. Food and Drug Administration's Bacteriological Analytical Manual as a reference according to the AOAC guideline. The medium sheet showed 100% inclusivity and exclusivity. Ruggedness study suggested allowances in the incubation temperature and time as 33-35 degrees C and 24 +/- 4 h, respectively. The performance of 3 different lots of the medium sheets was equivalent and suggested no change of the performance at least for 3 years. In the comparative recovery study, many samples (84.6%), which were inoculated with a coliform strain, showed no significant difference between the 2 methods. The linear correlation coefficient (r2) to the VRB agar was calculated as 0.94. In the repeatability study, the average relative standard deviation of total foods was 0.10 in the medium sheet. In the independent study, the medium sheet detected significantly more colonies than VRB plates in the frozen raw milk sample, while there was no significant difference between the 2 methods in raw ground beef sample. Comparative recovery study on foods, inoculated and then frozen, showed the medium sheet detected injured cells with better recovery than VRB agar. The analysts in the independent study wrote that the medium sheet was easy to use and read overall. The Sanita-kun sheet provides an alternative method to coliform count agar.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号