首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
ABT-869 is a novel ATP-competitive inhibitor for all the vascular endothelial growth factor (VEGF) and platelet-derived growth factor (PDGF) receptor tyrosine kinases (RTKs). It is one of the oncology drugs in development at Abbott Laboratories and has great potential for enhanced anti-tumor efficacy as well as activity in a broad range of human cancers. We report here an accurate, precise and rugged liquid chromatography/mass spectrometry (LC/MS/MS) assay for the quantitative measurement of ABT-869 and its acid metabolite A-849529. A fully automated 96-well liquid/liquid extraction method was achieved utilizing a Hamilton liquid handler. The only manual intervention required prior to LC/MS/MS injection is to transfer the 96-well plate to a drying rack to dry the extracts then transfer the plate back to the Hamilton for robotic reconstitution. The linear dynamic ranges were from 1.1 to 598.8 ng/mL for ABT-869 and from 1.1 to 605.8 ng/mL for A-849529. The coefficient of determination (r2) for all analytes was greater than 0.9995. For the drug ABT-869, the intra-assay coefficient of variance (CV) was between 0.4% and 3.7% and the inter-assay CV was between 0.9% and 2.8%. The inter-assay mean accuracy, expressed as percent of theoretical, was between 96.8% and 102.2%. For the metabolite A-849529, the intra-assay CV was between 0.5% and 5.1% and the inter-assay CV was between 0.8% and 4.9%. The inter-assay mean accuracy, expressed as percent of theoretical, was between 96.9% and 100.6%.  相似文献   

2.
Isoniazid and ethambutol are commonly used in various combination treatments for tuberculosis, and for this reason a rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of these two drugs in human plasma. After a simple protein precipitation using methanol, the analytes and the internal standard metformin were chromatographed on a C18 column and detected by MS/MS. An atmospheric pressure chemical ionization interface was chosen to reduce ion suppression from sample matrix components and provide high sensitivity. The LC retention times for isoniazid and ethambutol were 2.46 and 2.27 min, respectively. The method was linear in the concentration range of 10.0-5000 ng/mL for each analyte using 100 microL plasma. The intra- and inter-day precisions, expressed as the relative standard deviation (RSD), were less than 5.7 and 6.4%, determined from QC samples for isoniazid and ethambutol, and the accuracies were within +/-2.1% and +/-4.5% in terms of relative error, respectively. The method was successfully employed in a pharmacokinetic study after oral administration of a multicomponent formulation containing 150 mg isoniazid, 500 mg ethambutol, 150 mg rifampicin and 250 mg pyrazinamide.  相似文献   

3.
High-performance liquid chromatography/mass spectrometry (HPLC/MS) is increasingly perceived to be an essential tool in drug discovery at many key steps, like drug screening, lead identification, ADME profiling, and drug metabolism and pharmacology studies. High-throughput screenings in the early phase for metabolic stability, protein binding, permeability (ADME) and bioavailability are widely used to weed out compounds that do not exhibit the necessary characteristics. For such high-throughput LC/MS studies, a generic LC/MS method that can be used for a variety of compounds is desired. In this study, we used a small set of compounds with a wide range of properties to guide method development, and achieved a sample throughput of 1.7 min/sample. Here, we present a generic fast method that achieves good peak separation and peak shape on conventional HPLC systems using a column-switching mechanism for on-line solid-phase extraction (SPE)-HPLC/MS analysis. The method has a linear response range from 1 to 500 nM for the tested compounds. When a larger set of 658 randomly picked small molecules were analyzed using this method, 612 were observed with good signal intensity and HPLC peak shapes. This generic fast SPE-LC/MS method has been used to screen more than 1.5 million compounds repetitively against over 200 protein targets for hit confirmation and semi-quantitation of binding constants from biological assays. Over 7000 different compounds for a variety of protein-binding assays have been studied using this method for quantitative analysis as well.  相似文献   

4.
A method with parallel extraction columns and parallel analytical columns (PEC-PAC) for on-line high-flow liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for simultaneous quantification of a drug candidate and its six metabolites in dog plasma. Two on-line extraction columns were used in parallel for sample extraction and two analytical columns were used in parallel for separation and analysis. The plasma samples, after addition of an internal standard solution, were directly injected onto the PEC-PAC system for purification and analysis. This method allowed the use of one of the extraction columns for analyte purification while the other was being equilibrated. Similarly, one of the analytical columns was employed to separate the analytes while the other was undergoing equilibration. Therefore, the time needed for re-conditioning both extraction and analytical columns was not added to the total analysis time, which resulted in a shorter run time and higher throughput. Moreover, the on-line column extraction LC/MS/MS method made it possible to extract and analyze all seven analytes simultaneously with good precision and accuracy despite their chemical class diversity that included primary, secondary and tertiary amines, an alcohol, an aldehyde and a carboxylic acid. The method was validated with the standard curve ranging from 5.00 to 5000 ng/mL. The intra- and inter-day precision was no more than 8% CV and the assay accuracy was between 95 and 107%.  相似文献   

5.
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections.  相似文献   

6.
A liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed for determining dihydrostreptomycin, gentamicin C1, and neomycin in veal kidney, liver, and muscle. The extraction prior to injection on the automated cleanup/analysis system is very simple, permitting preparation of 24 veal samples for analysis in half a day of work. The extracts are purified online on a reversed-phase column, with the help of an ion-pairing agent, and the analytes are separated on a Nucleosil C18 column prior to analyses by electrospray MS/MS. The cleanup is sufficient to minimize ion suppression/enhancement phenomena and permits quantification of the analytes extracted from veal tissues. Four secondary ions were measured for every analyte, which gives unambiguous identification of the compounds under analysis. Calibration curves were linear for all analytes between 50 and 5000 ppb, and recoveries in kidney were 76, 57, and 51%, respectively, for dihydrostreptomycin, gentamicin C1, and neomycin. Estimated limits of detection for kidney were, respectively, 0.1, 0.1, and 0.4 ppb. When compared to an LC method with fluorescence detection, the method gave equivalent results for kidneys incurred with neomycin. This rugged method has been applied to the analysis of more than 1000 veal samples over a 1-year period.  相似文献   

7.
A high-throughput bioanalytical method for simultaneous quantitation of pravastatin and its metabolite (M1) in human serum was developed and validated using on-line extraction following liquid chromatography tandem mass spectrometry (LC-MS/MS). The on-line extraction was accomplished by the direct injection of a 50 microL serum sample, mixed 4:1 with an aqueous internal standard solution, into one of the extraction columns with aqueous 1 mm formic acid at flow rate of 3 mL/min. The separation and analysis were achieved by back-eluting the analytes from the extraction column and the analytical column to the mass spectrometer with an isocratic mobile phase consisting of 62% aqueous 1 mm formic acid and 38% acetonitrile at a flow rate of 0.8 mL/min. The second extraction column was being equilibrated while the first column was being used for analysis, and vice versa. The standard curve range was 0.500-100 ng/mL for pravastatin and M1. The lower limit of quantitation, 0.500 ng/mL for all the analytes, was achieved when 50 microL of human serum was used. The intra- and inter-day precisions were within 7.4%, and the accuracy was between 95 and 103%. The on-line extraction was finished in 0.5 min and total analysis time was 2.5 min per sample.  相似文献   

8.
Diazepam and its major metabolites, nordazepam, temazepam and oxazepam, in human urine samples, were analyzed by liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using a hydrophilic polymer column (MSpak GF-310 4B), which enables direct injection of crude biological samples. Matrix compounds in urine were eluted first from the column, while the target compounds were retained on the polymer stationary phase. The analytes retained on the column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. All compounds showed base-peak ions due to [M+H]+ ions on LC/MS with positive ion electrospray ionization, and product ions were produced from each [M+H]+ ion by LC/MS/MS. Quantification was performed by selected reaction monitoring. All compounds spiked into urine showed method recoveries of 50.1-82.0%. The regression equations for all compounds showed excellent linearity in the range of 0.5-500 ng/mL of urine. The limits of detection and quantification for each compound were 0.1 and 0.5 ng/mL of urine, respectively. The intra- and inter-day coefficients of variation for all compounds in urine were not greater than 9.6%. The data obtained from actual determination of diazepam and its three metabolites, oxazepam, nordazepam and temazepam, in human urine after oral administration of diazepam, are also presented.  相似文献   

9.
A method for the simultaneous quantification of 20 cocaine, amphetamine, opiate, and nicotine analytes in meconium, the first neonatal feces, by liquid chromatography tandem mass spectrometry was developed and validated. Specimen preparation included methanol homogenization and solid phase extraction. Two injections were required to achieve sufficient sensitivity and linear dynamic range. Linearity ranged from 0.5–25 up to 500 ng/g (250 ng/g p-hydroxymethamphetamine), and correlation coefficients were >0.996. Imprecision was <10.0% CV, analytical recovery 85.5–123.1%, and extraction efficiencies >46.7% at three concentrations across the linear range. Despite significant matrix effects of −305.7–40.7%, effects were similar for native and deuterated analytes. No carryover, endogenous or exogenous interferences were observed, with analyte stability at room temperature, 4 °C, and −20 °C and on the autosampler >70%, except for 6-acetylmorphine, hydrocodone, oxycodone, and morphine. Method applicability was demonstrated by analyzing meconium from drug-exposed neonates.  相似文献   

10.
A sensitive hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry method was developed and validated for the simultaneous detection and quantification of etilefrine and oxilofrine in equine blood plasma and urine. The method is highly sensitive and specific with good precision and accuracy. In plasma the limit of detection and limit of quantification are 0.03 and 0.1 ng/mL, respectively, for both analytes. In urine the limit of detection and limit of quantification are 0.3 and 1 ng/mL, respectively, for both analytes. The suitability of the method for doping control analysis in equine species is demonstrated by analyzing postadministration samples collected after a single intravenous administration of 50 mg etilefrine to a standardbred mare. Etilefrine was detected up to 120 h in urine and up to 48 h in plasma. Etilefrine is highly conjugated in equine urine whereas it exists in the free form in equine plasma. Therefore, enzyme hydrolysis prior to sample preparation is recommended for the detection and quantification of etilefrine and oxilofrine in equine urine.  相似文献   

11.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for simultaneous quantification of risperidone (RSP) and its active metabolite 9-hydroxyrisperidone (9-OH-RSP) in human plasma. The analytes were extracted from human plasma by using the protein precipitation extraction technique. Methyl risperidone was used as internal standard for RSP and 9-OH-RSP. A Betasil C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 411.28 --> 191.15 for RSP and m/z 427.30 --> 207.10 for 9-OH-RSP. The method involves a simple extraction, isocratic chromatography conditions and mass spectrometric detection that enable detection at sub-nanogram levels. The proposed method has been validated with a linear range of 0.10-15.0 ng/mL for RSP and 9-OH-RSP. The intrarun and interrun precision and accuracy values were within 15%. The overall recoveries for RSP and 9-OH-RSP were 82.1% and 83.2%, respectively. The total analysis time was as low as 3.0 min only. The developed method was applied for the determination of the pharmacokinetic parameters of RSP and 9-OH-RSP following a single oral administration of a 1 mg RSP tablet in 24 healthy male volunteers.  相似文献   

12.
A sensitive high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (MS/MS) method was developed and validated for the simultaneous quantification of trandolapril and its metabolite trandolaprilat in human plasma using ramipril as an internal standard. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M-H]- ions, m/z 429/168 for trandolapril, m/z 401/168 for trandolaprilat and m/z 415/166 for the internal standard. The method exhibited a linear dynamic range of 20-10,000 pg/mL for both trandolapril and trandolaprilat in human plasma. The lower limit of quantification was 20 pg/mL for both trandolapril and its metabolite. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

13.
A sensitive, accurate and reproducible procedure has been developed for the quantitative determination of gemcitabine (2',2'-difluorodeoxycytidine, dFdC) and its metabolite 2',2'-difluorodeoxyuridine (2dFdU) in human urine. The samples (2 mL) were extracted by solid-phase extraction (SPE) and analyzed by reversed-phase high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC/MS/MS), operating in multiple reaction monitoring (MRM mode). This procedure was validated using 2'-deoxycytidine as internal standard (IS). The urine assay was linear over the range 0-50 microg/L, with a limit of quantification (LLOQ) of 0.2 microg/L for gemcitabine and 1.0 microg/L for the metabolite. The respective limits of detection (LODs) for dFdC and 2dFdU were 0.05 and 0.3 microg/L. The precision and accuracy of the assay were determined on three different days. The within-series precision was found to be always less than 8.5 and 12.7% for gemcitabine and 2dFdU, respectively. The overall precision expressed as relative standard deviation (CVr) was always less than 7.1% for both analytes. The recovery of gemcitabine was always greater than 90% with a CVr <6.3%. The measurement uncertainty determined from the validation data assessed the possibility of determining this drug and its metabolite at trace levels in urine, considering that the combined uncertainty of the whole procedure was always less than 30%.  相似文献   

14.
A simple, rapid, sensitive and selective liquid chromatography/electrospray tandem mass spectrometry method was developed and validated for the simultaneous quantification of cilostazol and its primary metabolite 3,4-dehydrocilostazol in human plasma using mosapride as an internal standard. The method involves a simple one-step liquid-liquid extraction with a diethyl ether and dichloromethane mixture (7:3). The analytes were chromatographed using an isocratic mobile phase on a reversed-phase C18 column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 370/288 for cilostazol, m/z 368/286 for 3,4-dehydrocilostazol and m/z 422/198 for the internal standard. The assay exhibited a linear dynamic range of 5–2,000 ng/mL for cilostazol and 5–400 ng/mL for 3,4-dehydrocilostazol in human plasma. The lower limit of quantitation was 5 ng/mL for both cilostazol and its metabolite. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetics, bioavailability or bioequivalence studies.   相似文献   

15.
An ultrafast bioanalytical method using monolithic column high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) was evaluated for the simultaneous determination of a drug discovery compound and its metabolite in plasma. Baseline separation of the two compounds was achieved with run times of 24 or 30 s under isocratic or gradient conditions, respectively. The monolithic column HPLC/MS/MS system offers shorter chromatographic run times by increasing flow rate without sacrificing separation power for the drug candidate and its biotransformation product (metabolite). In this work, the necessity for adequate chromatographic resolution was demonstrated because the quantitative determination of the drug-related metabolism product was otherwise hampered by interference from the dosed drug compound. The chromatographic performance of a monolithic silica rod column as a function of HPLC flow rates was investigated with a mixture of the drug component and its synthetic metabolite. The assay reliability of the monolithic column HPLC/MS/MS system was checked for matrix ionization suppression using the post-column infusion technique. The proposed methods were successfully applied to the analysis of study rat plasma samples for the simultaneous quantitation of both the dosed drug and its metabolite. The analytical results obtained by the proposed monolithic column methods and the 'standard' silica particle-packed HPLC column method were in good agreement, within 10% error.  相似文献   

16.
A simple, sensitive, and selective liquid chromatography tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the simultaneous quantification of olanzapine (OLZ) and its metabolite N‐desmethylolanzapine (DMO) in human plasma for therapeutic drug monitoring. Sample preparation was performed by one‐step protein precipitation with methanol. The analytes were chromatographed on a reversed‐phase YMC‐ODS‐AQ C18 Column (2.0 × 100 mm,3 µm) by a gradient program at a flow rate of 0.30 mL/min. Quantification was performed on a triple quadrupole tandem mass spectrometer via electrospray ionization in positive ion mode. The method was validated for selectivity, linearity, accuracy, precision, matrix effect, recovery and stability. The calibration curve was linear over the concentration range 0.2–120 ng/mL for OLZ and 0.5–50 ng/mL for DMO. Intra‐ and interday precisions for OLZ and DMO were <11.29%, and the accuracy ranged from 95.23 to 113.16%. The developed method was subsequently applied to therapeutic drug monitoring for psychiatric patients receiving therapy of OLZ tablets. The method seems to be suitable for therapeutic drug monitoring of patients undergoing therapy with OLZ and might contribute to prediction of the risk of adverse reactions. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
With the ever-increasing workload from a variety of in vitro and in vivo screening procedures, new analytical methodologies to perform bioanalysis in an accurate and high-throughput manner are in great demand. In this work, monolithic columns were used instead of conventional particulate HPLC columns to perform chromatographic separations. Because the pressure drop on a monolithic column was considerably lower than that on a particulate column, a high flow rate (6 mL/min) was used for a 4.6 x 50 mm monolithic column with a total backpressure of about 61 bar measured using acetonitrile/water (50:50). The capability of using a regular column length at high flow rates, combined with the extremely small dependency of separation efficiency on linear flow velocity, allowed for the generation of sufficient chromatographic resolving power in a significantly reduced runtime. As demonstrated in this work, a plasma extract of a mixture of tempazepam, tamoxifen, fenfluramine, and alprozolam were baseline separated within a total analysis time of one minute. An average peak width at half maximum of approximately one second was noted using a generic broad gradient. It was also found that the separation efficiency and signal/noise (S/N) ratios for this separation remained almost constant at flow rates of 1, 3, and 6 mL/min, respectively. The ruggedness of the separation was evaluated by injecting 600 plasma extracts containing the replicates of a standard curve of the above mixture during an overnight run. The chromatographic retention time, separation quality, peak response and sensitivity were highly reproducible throughout the run. This high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) system has been used routinely in the authors' laboratory to support drug discovery programs.  相似文献   

18.
Chemically reactive metabolites may cause hepatotoxicity and as a result liver failure or other adverse side reactions. Therefore, this is a vital topic of interest because early reactive metabolite screening may prevent compound failure at a later stage. In order to address this issue, a screening assay has been developed to detect the formation of reactive metabolites by using glutathione as a trapping reagent, which will allow us to search for phase I metabolites and also glutathiones during in vitro metabolite screening using liquid chromatography/tandem mass spectrometry (LC/MS/MS) with exact mass. Glutathione conjugations when fragmented by the mass spectrometer give a common loss corresponding to the pyroglutamic acid moiety, which can be monitored. Until recently, this work has been carried out with triple quadrupole technology using nominal mass. The advantage of the hybrid quadrupole time-of-flight mass spectrometer is the selectivity and sensitivity that can be achieved. Exact neutral loss detection is achieved via sequential low- and high-energy MS acquisitions. After detection of the loss of the pyroglutamic acid moiety, using a window of +/-20 mDa on the high-energy scan, MS/MS is carried out on the parent mass of interest to confirm the common neutral loss.  相似文献   

19.
An HILIC-PI APCI MS/MS method is developed for the determination of seven biogenic amines (cadaverine, histamine, putrescine, spermidine, spermine, tryptamine and tyramine) in cheese. Their presence and relative amounts give useful information about freshness, level of maturing, quality of storage and cheese typicization. The major drawback in the analysis is represented by the relevant matrix effect and the general unbalanced concentrations of the different amines in cheese. The method proposed represents an improvement with respect to an HPLC-MS/MS method already developed in this laboratory. The new method permits better sensitivities it makes use of a Waters Atlantis HILIC (150.0 mm x 2.1 mm i.d., 3 microm) stationary phase and of a mobile phase of acetonitrile and ammonium formate 50.0 mM in ultrapure water brought to pH 4.00 for formic acid, flowing under gradient conditions. The chromatographic system is interfaced with a 3200QTrap LC-MS/MS system (Applied Biosystem, Foster City, CA, USA) by a Turbo V interface equipped with Heated Nebuliser (APCI) and Turbo Ion Spray (TIS) probes. LOQ values lower than 10 microg L(-1) are obtained. The method is applied in the analysis of Castelmagno cheese.  相似文献   

20.
Organophosphorus pesticides are commonly used in both agricultural and residential settings. The widespread use of these chemicals makes it almost impossible for humans to avoid exposure. In order to determine background human exposure, there is a need for fast, reliable, and sensitive analytical methods. We have developed a sensitive method to quantify specific biomarkers of the organophosphorus pesticides acephate, azinphos, chlorpyrifos, coumaphos, diazinon, isazofos, malathion, methamidophos, parathion and pirimiphos or their O,O-dimethyl analogues in human urine, as their selective metabolites or as the intact pesticide. Isotopically labeled internal standards were used for eight of the analytes. The use of labeled internal standards in combination with high-performance liquid chromatography electrospray ionization–tandem mass spectrometry provided a high degree of specificity. Repeated analysis of urine samples fortified with high and low concentrations of the analytes gave relative standard deviations (RSD) of less than 10% for the analytes with an isotopically labeled standard. Analytes without isotopically labeled standards had higher RSD. For all compounds except methamidophos and acephate, the recoveries were greater than 70%. The limits of quantification for most of the analytes were in the range of 0.1 to 1 ng/mL. We detected concentrations of most of these pesticides and/or their metabolites in urine samples from non-occupationally exposed persons using our method. Our frequencies of detection for the analytes measured ranged from 1% to 98%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏