1.
Influenza A is viral disease, which is a cause of yearly epidemics and, potentially, pandemics. The conventional techniques used today are equipment-demanding, time-consuming and laborious. Recently, we have confirmed that the capillary isoelectric focusing is a suitable fast alternative for the verifying of virus purity. In the wide pH gradient of pH range 2.0-7.5 the isoelectric points for subtypes of equine (H3N8) and swine (H1N2) influenza A viruses were determined approximately as 6.6 and 6.5, respectively. In this contribution we have verified these findings using different isolates of different viral subtypes of swine influenza, H1N1, H1N2, and of equine influenza, H3N8, H7N7, which were separated by capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF) in the narrow pH gradient pH range from 6.0 to 7.0. It was found that the isoelectric points of different isolates and subtypes of equine and swine influenza are almost independent of their origin. The electromigration velocities of subtypes of equine or swine influenza viruses were dependent on the antigenic subtypes of their surface glycoproteins. The detection sensitivity of the influenza viruses labeled by the fluorescent non-ionogenic tenside based on poly(ethylene glycol)pyrenebutanoate for fluorometric detection was increased and down to ten labeled viruses were detected. The isoelectric points of the native and labeled equine and swine influenza A viruses and their subtypes do not differ. According to our experiments these methods appear to be useful for the fast preliminary differentiation of influenza viruses in future.  相似文献   

2.
本文提出毛细管电泳-间接激光光热干涉检测新方法。采用吸收系数大、吸收波长与泵浦激光(He-Ne)波长匹配性能较好的亚甲蓝溶液为背景电解质溶液,加入乙醇减少了毛细管壁对亚甲蓝的吸附作用。并将间接光热干涉检测法用于氨基酸毛细管电泳分离检测,对赖氨酸检测限达5×10-6mol/L(S/N=2).  相似文献   

3.
A method of nonaqueous capillary zone electrophoresis (CZE) has been developed to characterize block (co)polymers of poly(ethylene oxide) and poly(styrene) containing metallo bis(terpyridine) complexes as bridging units. Specific CZE separation conditions had to be applied, with barium perchlorate dissolved in N-methylformamide (NMF) as background electrolyte and OV-1701-OH deactivated capillaries. For detection UV absorption was measured at a wavelength of 316 nm. Metallo diblock polymers with molecular weights up to 30,000 Da could be analyzed by the proposed nonaqueous CZE method. Experiments performed with polymeric compounds containing Fe, Ni or Ru as central metal ions showed that their electrophoretic mobilities were independent of the type of metal ion. Therefore, the data on the size of the polymeric compounds could be obtained using just one set of calibration standards. Polydispersities of the samples calculated from the experimental results were in correlation with the polydispersities of the polymers used in the synthesis of the metallo diblock polymers. Several polymeric samples contained metallo mono(terpyridine) complexes as impurities. These by-products could be separated from the main product. With symmetrical diblock polymers only one by-product was detected, while with an asymmetric diblock polymer two types of mono-complexes were found. The amount of the mono-complexes present as impurities was dependent on the type of central metal ion (Ni > Fe >> Ru).  相似文献   

4.
A new sensitive method has been developed for the determination of haloalkane dehalogenase activity. The enzymatic reactions were carried out directly in thermostatted autosampler vials and the formation of product - bromide or chloride ions - was monitored by sequential capillary zone electrophoresis runs. The determinations were performed in a 75 microm fused-silica capillary using 5 mM chromate, 0.5 mM tetradecyltrimethylammonium bromide (pH 8.4) as a background electrolyte, separation voltage 15 kV (negative polarity) and indirect detection at sample wavelength 315 nm, reference wavelength 375 nm for brominated and chlorinated substrates, respectively 0.1 M beta-alanine-HCl (pH 3.50) as a background electrolyte, separation voltage 18 kV (negative polarity) and direct detection at 200 nm for brominated substrates. The temperature of capillary was in both cases 25 degrees C. The method is rapid, can be automated, and requires only small amount of enzyme preparation and substrate.  相似文献   

5.
Liu AL  He FY  Hu YL  Xia XH 《Talanta》2006,68(4):1303-1308
Rapid separation and determination of acetaminophen and its hydrolysate with end-channel electrochemical (EC) detection integrated on a plastified poly(ethylene terephthalate) (PET)-toner microchip capillary electrophoresis (CE) system was investigated. In this separation and detection system, a Pt ultramicroelectrode integrated on a three-dimensional adjustor was used as working electrode. Factors influencing the separation and detection were investigated and optimized. Results show that acetaminophen and p-aminophenol can be well separated within 84 s with R.S.D. < 1% for migration time and R.S.D. < 3.6% for detection current for both analytes. Detection limits for both analytes are determined to be 5.0 μM (S/N = 3). This method has been successfully applied to the detection of trace p-aminophenol in paracetamol tablets. The results demonstrate that the PET-toner microchips can obtain better performance than PDMS microfluidic devices but at much lower cost.  相似文献   

6.
The means of the preconcentration and preseparation of selected species or pathovars of bacteria directly from the plant tissue suspension by free flow isoelectric focusing are introduced here. After the focusing, the resulting fraction of microorganisms, native or dynamically modified by the non-ionogenic tenside on the basis of pyrenebutanoate, was separated by capillary isoelectric focusing and/or cultivated and positively identified by gas chromatographic analysis of fatty acid methyl esters. Simultaneously, capillary isoelectric focusing with UV and fluorometric detection was used for the rapid estimation of unknown isoelectric points of the examined plant pathogenic species of genus Clavibacter, Xanthomonas and Pseudomonas prior to the preconcentration and preseparation. The microorganisms were of different origin, native and/or dynamically modified by the non-ionogenic tenside.  相似文献   

7.
Wei F  Fan Y  Zhang M  Feng YQ 《Electrophoresis》2005,26(16):3141-3150
A method based on in-tube solid-phase microextraction and capillary zone electrophoresis (CZE) was proposed for simultaneously determining four amphetamines (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine) in urine. A poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column, which can provide sufficient extraction efficiency, was introduced for the extraction of amphetamines from urine samples. The hydrophobic main chains and acidic pendant groups of the monolithic column make it a superior material for extraction of basic analytes from aqueous matrix. After extraction, the samples were analyzed by CZE. The best separation was achieved using a buffer composed of 0.1 M disodium hydrogen phosphate (adjusted to pH 4.5 with 1 M hydrochloric acid) and 20% methanol v/v, with a temperature and voltage of 25 degrees C and 20 kV, respectively. By applying electrokinetic injection with field-amplified sample stacking, detection limits of 25-34 microg/L were achieved. Excellent method of reproducibility was found over a linear range of 0.1-5 mg/L. Determination of these analytes from abusers' urine sample was also demonstrated.  相似文献   

8.
Yang X  Hu X  Li F  Wang X  Cao Q 《色谱》2012,30(5):501-506
在系统优化了电解质溶液的pH、组成、浓度及仪器条件的基础上,建立了一种测定不同来源血竭中龙血素A和龙血素B的毛细管区带电泳(CZE)方法。采用20 kV的分离电压,25 ℃的毛细管柱温,211 nm的检测波长以及5 s的压力(3447 Pa)进样时间,在20 mmol/L的Na2B4O7缓冲溶液(用NaOH调节pH到9.98,含有10%(v/v,下同)乙腈、5.0%乙二醇和1.0%正丁醇)中,龙血素A和龙血素B在15 min内得到了有效分离与检测。方法的线性范围对于龙血素A和龙血素B分别为1.0~100.0 mg/L和0.5~100.0 mg/L。将该方法用于天然血竭及人工诱导血竭中龙血素A和龙血素B的测定,相对标准偏差在0.6%~3.8%之间,加标回收率在95.1%~105.8%之间。方法具有简单、快速、重现性较好和准确度较高的优点,可以用于血竭样品中龙血素A和龙血素B的测定。  相似文献   

9.
A sensitive high-performance capillary zone electrophoresis (CZE) with head-column field-amplified sample stacking (FASS) in binary system has been developed for the simultaneous determination of zotepine and its active metabolite, norzotepine, in human plasma. The separation of zotepine and norzotepine was performed using a background electrolyte consisting of 50% ethylene glycol-borate buffer (20mM, pH 8.0) solution with 20% methanol as the running buffer and on-column detection at 200 nm. Under the optimal FASS-CZE condition, good separation with high efficiency and short analysis time is achieved. Several parameters affecting the separation and sensitivity of the drug were studied, including sample matrix, pH and concentrations of the borate buffer, ethylene glycol and methanol. Using clozapine as an internal standard, the linear ranges of the method for the determination of zotepine and norzotepine in human plasma were over 3-100 ng/mL; the detection limits of zotepine and norzotepine in plasma were 2 and 1 ng/mL, respectively. A sample pretreatment by means of solid-phase extraction (SPE) with subsequent quantitation by FASS-CZE was used. The application of the proposed method for determination of zotepine and norzotepine in plasma collected after oral administration of 125 mg zotepine in one schizophrenic patient was demonstrated.  相似文献   

10.
复方丹参滴丸的毛细管电泳指纹图谱   总被引:2,自引:0,他引:2  
孙国祥  宋宇晴 《色谱》2009,27(4):494-498
采用毛细管区带电泳法建立了复方丹参滴丸(Compound Danshen Dropping Pill,CDDP)的指纹图谱。以50 mmol/L硼砂-200 mmol/L硼酸(体积比为1:1,含1.1%(体积分数)三乙胺)为背景电解质溶液,采用未涂层石英毛细管(75 cm×75 μm,有效分离长度63 cm),运行电压18 kV,紫外检测波长290 nm,以原儿茶醛(protocatechualdehyde,PAH)峰为参照物峰确定8个共有峰,建立了CDDP的毛细管电泳指纹图谱(capillary electrophoresis fingerprint,CEFP)。用系统指纹定量法评价CEFP所反映的CDDP质量,依据系统指纹定量法划分10批CDDP的质量级别,仅有1批含量偏低。系统指纹定量法可以对中药及其制剂进行较好的全质量控制,所建立的CEFP具有较好的精密度和重现性,为CDDP的质量控制提供了新的参考。  相似文献   

11.
In this report, a graphene/poly(ethylene‐co‐vinyl acetate) composite electrode was fabricated by melt compounding for the amperometric detection of capillary electrophoresis. The composite electrode was fabricated by packing a mixture of graphene and melted poly(ethylene‐co‐vinyl acetate) in a piece of fused silica capillary under heat. The structure of the composite was investigated by scanning electron microscopy and Fourier transform infrared spectroscopy. The results indicated that graphene sheets were well dispersed in the composite to form an interconnected conducting network. The performance of this unique graphene‐based detector has been demonstrated by separating and detecting rutin, quercitrin, kaempferol, and quercetin in Cacumen platycladi in combination with capillary electrophoresis. The four flavones have been well separated within 9 min in a 50‐cm‐long capillary at a separation voltage of 12 kV using a 50 mM sodium borate buffer (pH 9.2). The graphene‐based detector offered significantly lower operating potentials, substantially enhanced signal‐to‐noise characteristics, lower expense of operation, high resistance to surface fouling, and enhanced stability. It showed long‐term stability and repeatability with relative standard deviations of <5% for the peak current (n = 15).  相似文献   

12.
A brush-like copolymer consisting of poly(ethylene glycol) methyl ether methacrylate and N,N-dimethylacrylamide (PEGMA-DMA) was synthesized and used as a novel static physically adsorbed coating for protein separation by capillary electrophoresis for the first time, in order to stabilize electroosmotic flow (EOF) and suppress adsorption of proteins onto the capillary wall. Very stable and low EOF was obtained in PEGMA-DMA-coated capillary at pH 2.2-7.8. The effects of molar ratio of PEGMA to DMA, copolymer molecular mass, and pH on the separation of basic proteins were discussed. A comparative study of bare capillary with PEGMA-DMA-coated capillary for protein separation was also performed. The basic proteins could be well separated in PEGMA-DMA-coated capillary over the investigated pH range of 2.8-6.8 with good repeatability and high separation efficiency because the copolymer coating combines good protein-resistant property of PEG side chains with excellent coating ability of PDMA-contained backbone. Finally, the coating was successfully applied to the fast separation of other protein samples, such as protein mixture and egg white, which reveals that it is a potential coating for further proteomics analysis.  相似文献   

13.
建立了毛细管电泳-紫外检测法测定水产品中己烷雌酚(HXS)、己烯雌酚(DES)及双烯雌酚(DIES)残留的新方法。研究了缓冲体系的酸度、浓度、添加剂、分离电压、进样时间及温度等对组分分离的影响。在检测波长为200 nm,分离电压为20 kV,运行缓冲液为50 mmol/L硼砂-25 mmol/L氢氧化纳(pH12.3,含30%的N,N-二甲基甲酰胺)的条件下,3种目标组分在14 min内达到基线分离。HXS、DES与DIES的质量浓度与峰面积分别在2.0~120、1.0~100、1.0~100 mg/L范围内呈良好线性,相关系数(r2)分别为0.9998、0.9992、0.9994,检出限为0.3~0.9 mg/L。将该方法用于鲫鱼中3种雌酚类激素的检测,结果令人满意。  相似文献   

14.
To stabilize electroosmotic flow (EOF) and suppress protein adsorption onto the silica capillary inner wall, a cationic hydroxyethylcellulose-graft-poly (poly(ethylene glycol) methyl ether methacrylate) (cat-HEC-g-PPEGMA) graft copolymer composed of cationic backbone and bottle brush-like side chains was synthesized for the first time and used as a novel physically adsorbed coating for protein separation by capillary electrophoresis. Reversed (anodal) and very stable EOF was obtained in cat-HEC-g-PPEGMA-coated capillary at pH 2.2-7.8. The effects of degree of cationization, PEGMA grafting ratio, PEGMA molecular mass, and buffer pH on the separation of basic proteins were investigated. A systematic comparative study of protein separation in bare and HEC-coated capillaries and in cat-HEC-g-PPEGMA-coated capillary was also performed. The basic proteins can be well separated in cat-HEC-g-PPEGMA-coated capillary over the pH range of 2.8-6.8 with good repeatability and high separation efficiency, because the coating combines good protein-resistant property of bottle brush-like PPEGMA side chains with excellent coating ability of cat-HEC backbone. Besides its success in separation of basic proteins, the cat-HEC-g-PPEGMA coating was also superior in the fast separation of other protein samples, such as protein mixture, egg white, and saliva, which indicates that it is a promising coating for further proteomics analysis.  相似文献   

15.
Analytical capabilities of capillary zone electrophoresis (CZE) with on-line coupled capillary isotachophoresis (ITP) sample pretreatment in the column-coupling capillary electrophoresis equipment to separate and determine enantiomers present in multicomponent ionic matrices were studied. Tryptophan was used as a model analyte in the ITP-capillary zone electrophoresis experiments performed in this context while a 90-component model mixture of UV-light absorbing organic anions and urine served as multicomponent sample matrices. Various working modes in which the on-line coupled capillary isotachophoresis-capillary zone electrophoresis combination in the column-coupling separation system can operate were employed in the anionic regime of the separation with direct injections of the samples. Advantages and limitations of these working modes in the separations of enantiomers present in model and urine matrices were assessed. Experiments with model mixtures of tryptophan enantiomers revealed that the two were resolved in the capillary zone electrophoresis stage with the aid of alpha-cyclodextrin also when their concentration ratio in the sample was 1:200 while the concentration of L(-)-tryptophan was 25 nmol/l. The limits of detection for the enantiomers were at approximately 10 nmol/l (approximately 1.5 ng/ml) concentrations for a 220 nm detection wavelength of the UV detector employed in the capillary zone electrophoresis stage and for a 30 microliters sample load. A high sample load capacity of the on-line coupled capillary isotachophoresis stage was effective in separating the samples corresponding to 3-6 microliters volumes of undiluted urine. The results from the runs with urine samples showed that only the capillary isotachophoresis-capillary zone electrophoresis combination with a post-column on-line coupled capillary isotachophoresis sample clean-up (responsible for a removal of more than 99% of the sample anionic constituents migrating in the on-line coupled capillary isotachophoresis stack and detectable in the capillary zone electrophoresis stage) provided a universal alternative for the detection and quantitation of the model analyte (L(-)-tryptophan).  相似文献   

16.
Capillary zone electrophoresis was used to show the coupling between NH2-terminated poly(ethylene oxide) and oligomers of lactic acid activated by transforming carboxyl chain ends to acyl chloride ones. The demonstration was based on the use of fused-silica capillary physically modified by pre-adsorption of polycations in the reversed polarity mode. As poly(ethylene oxide) macromolecules are UV transparent, indirect UV detection was used. A creatinine solution at pH 4.8 was selected as background electrolyte. Commercially available polycations with different structures were tested. It was shown that the reversed electroosmosis could be modulated according to the structure of the polycation. The method was then applied to analyse a commercial alpha,omega-diamino poly(ethylene oxide), namely Jeffamine ED 600 characterised by a broad mass dispersion. Data showed that the method can detect and separate amino poly(ethylene oxide) of different structures. When applied to analyse post coupling products, no free NH2-terminated poly(ethylene oxide) segments were detected. Moreover, the method allowed detection of water-soluble oligomers generated by partial degradation of lactic segments during the reaction.  相似文献   

17.
Monolithic stationary phases based on poly(ethylene glycol) diacrylates for capillary electrochromatography were developed. Several poly(ethylene glycol) diacrylates (Mn 250, 575, and 700) were used as single monomers and the resulting columns were carefully compared. Methanol and ethyl ether were selected as porogenic solvents, and in all cases ultraviolet radiation was selected as initiation method to prepare polymeric monoliths. The influence of the monomer chain length and ratio monomer/porogen on the morphological and electrochromatographic properties of the resulting monoliths was investigated. Several families of compounds with different polarity (alkyl benzenes, organophosphorous pesticides, benzoic acid derivatives, and sulfonamides) were selected to evaluate the performance of the fabricated monolithic columns. The best results were obtained for poly(ethylene glycol) diacrylate 700 monoliths affording efficiencies of 144 000 plates/m for retained polar aromatic small molecules and excellent reproducibility in column preparation (RSD values below 2.5%).  相似文献   

18.
The aim of the present study was to verify the analytical performances of high-performance liquid chromatography (HPLC) and micellar electrokinetic capillary chromatography (MEKC) for the separation and qualitative determination of a selected group of organic components of smokeless gunpowders. The HPLC method was based on a gradient reversed-phase elution with a mobile phase composed of 0.17 M H(3)PO(4)/methanol; detection was performed by UV absorption at the wavelengths of 220, 254, and 270 nm. The MEKC experiments were carried out by using uncoated fused-silica capillaries (50 microm inside diameter, 50 cm effective length) and a running buffer composed of 10 mM sodium tetraborate at pH 9.24 added with 25 mM sodium dodecyl sulfate (SDS); the applied voltage was 25 kV; detection was either at a fixed wavelength UV of 214 nm or with a diode-array detector operating in the wavelength range from 190 to 350 nm. Both reversed-phase HPLC and MEKC techniques succeeded in resolving the tested standard mixtures of organic components of smokeless powders. Although the sequence of elution of the different analytes was slightly different between HPLC and MEKC, a statistical analysis based on the Spearman's rank correlation test showed that the two separation patterns were highly correlated. HPLC and MEKC were comparable in terms of elution/migration time precision, whereas MEKC showed higher reproducibility of peak areas. The interfacing of capillary electrophoresis with diode array UV detection provided distinct UV spectra of the individual analytes, thus improving, on the detection side, the analytical selectivity and identification power of capillary electrophoresis.  相似文献   

19.
A new method using capillary zone electrophoresis was developed for the rapid quantification of two common uronic acids, galacturonic acid and glucuronic acid, based on utilization of an alkaline background electrolyte with reversed electroosmotic flow (EOF) within 16 min. The method relies on in‐capillary reaction and direct UV detection at the wavelength 270 nm. The optimum electrolyte solution was prepared of 130 mm sodium hydroxide, 36 mm disodium hydrogen phosphate dihydrate and 0.5 mm cetyltrimethylammonium bromide. EOF was reversed to detect uronic acids and to improve the separation of neutral sugars. The established method was validated and the results showed good linearity, high precision and satisfactory sensitivity. The newly developed method was successfully applied to analyze galacturonic acid and glucuronic acid content in Forsythia suspensa polysaccharides. The method is fast since only sample hydrolysis and dilution are required in the sample preparation. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
根际土壤溶液中磷的毛细管电泳分析   总被引:1,自引:0,他引:1  
应用毛细管区带电泳间接紫外吸收法,对测定根际土壤溶液中PO43-的检测波长、电泳温度、分离电压和电解液组成等参数进行了选择,发展了根际土壤溶液中PO34-浓度的毛细管电泳分析法。选择后的电泳条件为:电解液为32mmol/L三羟甲基氨基甲烷+4mmol/L1,2,4-苯三酸+0.3mmol/L十六烷基三甲基溴化铵(pH=8.5);检测波长为205nm,分离电压为-20kV,温度为25℃。本方法有效地屏蔽了土壤溶液中Cl-,SO42-和NO3-等离子对PO43-测定的影响,对根际土壤溶液中PO43-的检出限为0.68mg/L(S/N=3);回收率为87.2%~99.4%,适于测定微量根际土壤溶液样品中PO34-的浓度。  相似文献   