In this study, liquid chromatography time-of-flight mass spectrometry (HPLC/TOF-MS) is applied to qualitation and quantitation of 18 synthetic preservatives in beverage. The identification by HPLC/TOF-MS is accomplished with the accurate mass (the subsequent generated empirical formula) of the protonated molecules [M + H]+ or the deprotonated molecules [M − H]−, along with the accurate mass of their main fragment ions. In order to obtain sufficient sensitivity for quantitation purposes (using the protonated or deprotonated molecule) and additional qualitative mass spectrum information provided by the fragments ions, segment program of fragmentor voltages is designed in positive and negative ion mode, respectively. Accurate mass measurements are highly useful in the complex sample analyses since they allow us to achieve a high degree of specificity, often needed when other interferents are present in the matrix. The mass accuracy typically obtained is routinely better than 3 ppm. The 18 compounds behave linearly in the 0.005-5.0 mg·kg−1 concentration range, with correlation coefficient >0.996. The recoveries at the tested concentrations of 1.0 mg·kg−1-100 mg·kg−1 are 81-106%, with coefficients of variation <7.5%. Limits of detection (LODs) range from 0.0005 to 0.05 mg·kg−1, which are far below the required maximum residue level (MRL) for these preservatives in foodstuff. The method is suitable for routine quantitative and qualitative analyses of synthetic preservatives in foodstuff.  相似文献   

2.
The authors' laboratory at one time employed four liquid chromatography/mass spectrometric (LC/MS) methods for the detection of a large variety of drugs in equine urine. Drug classes covered by these methods included anti-diabetics, anti-ulcers, cyclooxygenase-2 (COX-2) inhibitors, sedatives, corticosteroids, anabolic steroids, sulfur diuretics, xanthines, etc. With the objective to reduce labour and instrumental workload, a new ultra performance liquid chromatography/tandem mass spectrometric (UPLC/MS/MS) method has been developed, which encompasses all target analytes detected by the original four LC/MS methods. The new method has better detection limits than the superseded methods. In addition, it covers new target analytes that could not be adequately detected by the four LC/MS methods. The new method involves solid-phase extraction (SPE) of two aliquots of equine urine using two Abs Elut Nexus cartridges. One aliquot of the urine sample is treated with β-glucuronidase before subjecting to SPE. A second aliquot of the same urine sample is processed directly using another SPE cartridge, so that drugs that are prone to decomposition during enzyme hydrolysis can be preserved. The combined eluate is analysed by UPLC/MS/MS using alternating positive and negative electrospray ionisation in the selected-reaction-monitoring mode. Exceptional chromatographic separation is achieved using an UPLC system equipped with a UPLC(?) BEH C18 column (10 cm L×2.1 mm ID with 1.7 μm particles). With this newly developed UPLC/MS/MS method, the simultaneous detection of 140 drugs at ppb to sub-ppb levels in equine urine can be achieved in less than 13 min inclusive of post-run equilibration. Matrix interference for the selected transitions at the expected retention times is minimised by the excellent UPLC chromatographic separation. The method has been validated for recovery and precision, and is being used regularly in the authors' laboratory as an important component of the array of screening methods for doping control analyses of equine urine samples.  相似文献   

3.
A general screening method based on solid phase extraction (SPE) and liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) was developed and investigated with 124 different doping agents, including stimulants, -blockers, narcotics, -adrenergic agonists, agents with anti-estrogenic activity, diuretics and cannabinoids. Mixed mode cation exchange/C8 cartridges were applied to SPE, and chromatography was based on gradient elution on a C18 column. Ionization of the analytes was achieved with electrospray ionization in the positive mode. Identification by LC/TOFMS was based on retention time, accurate mass and isotopic pattern. Validation of the method consisted of analysis of specificity, analytical recovery, limit of detection and repeatability. The minimum required performance limit (MRPL), established by World Anti-Doping Agency (WADA), was attained to 97 doping agents. The extraction recoveries varied between 33 and 98% and the median was 58%. Mass accuracy was always better than 5 ppm, corresponding to a maximum mass error of 0.7 mDa. The repeatability of the method for spiked urine samples, expressed as median of relative standard deviations (RSD%) at concentrations of MRPL and 10 times MRPL, were 14% and 9%, respectively. The suitability of the LC/TOFMS method for doping control was demonstrated with authentic urine samples.  相似文献   

4.
The last 2 years multi-compound methods are gaining ground as screening methods. In this study a high-resolution liquid chromatography combined with time-of-flight mass spectrometry (HRLC–ToF-MS) is tested for the screening of about 100 veterinary drugs in three matrices, meat, fish and egg. While the results are satisfactory for 70–90% of the veterinary drugs, a more efficient sample preparation or extract purification is required for quantitative analysis of all analytes in more difficult matrices like egg. The average mass measurement error of the ToF-MS for the veterinary drugs spiked at concentrations ranging from 4 to 400 μg/kg, is 3.0 ppm (median 2.5 ppm) with little difference between the three matrices, but slightly decreases with increasing concentration. The SigmaFit value, a new feature for isotope pattern matching, also decreases with increasing concentration and, in addition, shows an increase with increasing matrix complexity. While the average SigmaFit value is 0.04, the median is 0.01 indicating some high individual deviations. As with the mass measurement error, the highest deviations are found in those regions of the chromatogram where most compounds elute from the column, be it analytes or matrix compounds. The median repeatability of the method ranges from 8% to 15%, decreasing with increasing concentration, while the median reproducibility ranges from 15% to 20% with little difference between matrices and concentrations. The median accuracy is in between 70% and 100% with a few compounds showing higher values due to matrix interference. The squared regression coefficient is >0.99 for 92% of the compounds showing a good overall linearity for most compounds. The detection capability, CCβ, is within 2 times the associated validation level for >90% of the compounds studied. By changing a few conditions in the analyses protocol and analysing a number of blank samples, it was determined that the method is robust as well as specific. Finally, an alternative validation strategy is proposed and tested for screening methods. While the results calculated for repeatability, within-lab reproducibility and CCβ show a good comparison for the matrices meat and fish, and a reasonable comparison for the matrix egg, only 27 analyses are required to obtain these results versus 63 analysis in the traditional, 2002/657/EC, approach. This alternative is suggested as a cost-effective validation procedure for screening methods.  相似文献   

5.
An efficient method was developed for toxicological drug screening in urine by liquid chromatography coupled with electrospray ionization time-of-flight mass spectrometry. The method relies on a large target database of exact monoisotopic masses representing the elemental formulae of reference drugs and their metabolites. Mass spectral identification is based on matching measured accurate mass and isotopic pattern (SigmaFit) of a sample component with those in the database. Data post-processing software was developed for automated reporting of findings in an easily interpretable form. The mean and median of SigmaFit for true-positive findings were 0.0066 and 0.0051, respectively. The mean and median of mass error absolute values for true-positive findings were 2.51 and 2.17 ppm, respectively, corresponding to 0.65 and 0.60 mTh. For routine screening practice, a SigmaFit tolerance of 0.03 and a mass tolerance of 10 ppm were chosen. Ion abundance differences from urine extracts did not affect the accuracy of the automatically acquired SigmaFit or mass values. The results show that isotopic pattern matching by SigmaFit is a powerful means of identification in addition to accurate mass measurement.  相似文献   

6.
A unification of doping-control screening procedures of prohibited small molecule substances—including stimulants, narcotics, steroids, β2-agonists and diuretics—is highly urgent in order to free resources for new classes such as banned proteins. Conceptually this may be achieved by the use of a combination of one gas chromatography–time-of-flight mass spectrometry method and one liquid chromatography–time-of-flight mass spectrometry method. In this work a quantitative screening method using high-resolution liquid chromatography in combination with accurate-mass time-of-flight mass spectrometry was developed and validated for determination of glucocorticosteroids, β2-agonists, thiazide diuretics, and narcotics and stimulants in urine. To enable the simultaneous isolation of all the compounds of interest and the necessary purification of the resulting extracts, a generic extraction and hydrolysis procedure was combined with a solid-phase extraction modified for these groups of compounds. All 56 compounds are determined using positive electrospray ionisation with the exception of the thiazide diuretics for which the best sensitivity was obtained by using negative electrospray ionisation. The results show that, with the exception of clenhexyl, procaterol, and reproterol, all compounds can be detected below the respective minimum required performance level and the results for linearity, repeatability, within-lab reproducibility, and accuracy show that the method can be used for quantitative screening. If qualitative screening is sufficient the instrumental analysis may be limited to positive ionisation, because all analytes including the thiazides can be detected at the respective minimum required levels in the positive mode. The results show that the application of accurate-mass time-of-flight mass spectrometry in combination with generic extraction and purification procedures is suitable for unification and expansion of the window of screening methods of doping laboratories. Moreover, the full-scan accurate-mass data sets obtained still allow retrospective examination for emerging doping agents, without re-analyzing the samples.  相似文献   

7.
李上富  向丽  蔡宗苇 《色谱》2017,35(1):80-85
建立了一种基于母离子扫描模式的超高效液相色谱-三重四极杆质谱检测尿液中酰基肉碱的分析方法。对酰基肉碱类化合物所共有的m/z为60、85和144的碎片离子进行选择性检测,结合化合物母离子扫描的结果及其对应的保留时间,选取一致性较好的化合物进行筛选,再利用高分辨质谱确认,最终检测到37种酰基肉碱化合物,其中有14种尚未被HMDB和LIPID MAPS数据库收录。该方法可应用于其他生物样本(如血液、组织)中酰基肉碱的定性、定量分析,可作为检测酰基肉碱化合物的新选择。  相似文献   

8.
The present study describes a novel approach for utilizing liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) in qualitative screening analysis. An LC/TOFMS method was developed for screening toxicologically relevant substances in urine samples. After solid phase extraction and LC separation, the method included full spectrum acquisition followed by automatic internal calibration, searching against a target library, and reporting positive identifications. The target library, containing 433 toxicologically relevant substances in the mass range of 105-734 Da, was created simply by entering the elemental formulas of substances into the instrument software for the calculation of their respective monoisotopic masses. In addition to parent drugs, the library contained selected urinary drug metabolites, based on their structures available in the literature. Identification was based on the exact masses of the compounds. The LC/TOFMS method provided 5-10 ppm mass accuracy for a majority of identified compounds in authentic urine samples. Compared with established thin-layer and gas chromatographic methods, the LC/TOFMS method produced similar findings in urine with the additional advantage of metabolite identification without actual reference substances.  相似文献   

9.
The urinary steroid profile is constituted by anabolic androgenic steroids, including testosterone and its relatives, that are extensively metabolized into phase II sulfated or glucuronidated steroids. The use of liquid chromatography coupled to mass spectrometry (LC-MS) is an issue for the direct analysis of conjugated steroids, which can be used as urinary markers of exogenous steroid administration in doping analysis, without hydrolysis of the conjugated moiety. In this study, a sensitive and selective ultra high-pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometer (UHPLC-QTOF-MS) method was developed to quantify major urinary metabolites simultaneously after testosterone intake. The sample preparation of the urine (1 mL) was performed by solid-phase extraction on Oasis HLB sorbent using a 96-well plate format. The conjugated steroids were analyzed by UHPLC-QTOF-MSE with a single-gradient elution of 36 min (including re-equilibration time) in the negative electrospray ionization mode. MSE analysis involved parallel alternating acquisitions of both low- and high-collision energy functions. The method was validated and applied to samples collected from a clinical study performed with a group of healthy human volunteers who had taken testosterone, which were compared with samples from a placebo group. Quantitative results were also compared to GC-MS and LC-MS/MS measurements, and the correlations between data were found appropriate. The acquisition of full mass spectra over the entire mass range with QTOF mass analyzers gives promise of the opportunity to extend the steroid profile to a higher number of conjugated steroids.  相似文献   

10.
Thyreostatic drugs, illegally administrated to livestock for fattening purposes, are banned in the European Union since 1981 (Council Directive 81/602/EC). For monitoring their illegal use, sensitive and specific analytical methods are required. In this study an UHPLC-MS/MS method was described for quantitative analysis of eight thyreostatic drugs in urine, this without a derivatisation step. The sample pretreatment involved a reduction step with dithiothreitol under denaturating conditions at 65 °C, followed by liquid-liquid extraction with ethyl acetate. This analytical procedure was subsequently validated according to the EU criteria (2002/657/EC Decision), resulting in decision limits and detection capabilities ranging between 1.1 and 5.5 μg L−1 and 1.7 and 7.5 μg L−1, respectively. The method obtained for all, xenobiotic thyreostats, a precision (relative standard deviation) lower than 15.5%, and the linearity ranged between 0.982 and 0.999. The performance characteristics fulfill not only the requirements of the EU regarding the provisional minimum required performance limit (100 μg L−1), but also the recommended concentration fixed at 10 μg L−1 in urine set by the Community of Reference Laboratories. Future experiments applying this method should provide the answer to the alleged endogenous status of thiouracil.  相似文献   

11.
Withdrawal of the support for the REMEDi HS drug profiling system has necessitated its replacement within our laboratories with an alternative broad toxicological screening technique. To this end, a novel method, based on ultra-performance liquid chromatography (UPLC) and time-of-flight (TOF) mass spectrometry, was developed for the routine analysis of urine samples. Identification was achieved by comparison of acquired data to libraries containing more than 300 common drugs and metabolites, and was based on a combination of retention time, exact mass and fragmentation patterns. Validation data for the method is presented and comprised an evaluation of the following parameters: precision; transferability of the methodology between the six collaborating laboratories; specificity; extraction recovery and stability of processed samples; matrix effects and sensitivity.This paper presents the benefits of supplementary fragmentation data with particular regard to increasing specificity and confidence of identification and its usefulness with overdosed samples. The utility of the method was assessed by the parallel analysis of 30 authentic urine samples using the REMEDi HS and UPLC-TOF. The latter provided enhanced detection, leading to the identification of twice as many drugs. Furthermore it did not miss any compounds that were identified by REMEDi HS. The UPLC-TOF findings were further verified by a combination of data from three other conventional screening techniques, i.e., GC-MS, HPLC-DAD and UPLC-MS/MS.  相似文献   

12.
陈溪  吴慈  王龙祥  王悦  宁兴爽  许传鹏  李旺  褚莹倩 《色谱》2018,36(11):1147-1157
采用超高效液相色谱-三重四极杆/静电场轨道阱高分辨质谱法(UHPLC-Q-Orbitrap MS),建立了水中112种药品和个人护理用品类污染物(PPCPs)的快速筛查及定量分析方法。水样分别在酸性及碱性条件下提取,分别经SPE柱净化,以UHPLC-Q-Orbitrap MS进行分离检测,采用全扫描/数据依赖二级扫描(Full MS/dd-MS2)模式进行扫描,实现了水中112种PPCPs的定性筛查,并基于一级母离子峰面积对其含量进行了定量检测。112种PPCPs的定量限为0.002~0.8 μg/L,在各自的线性范围内均呈良好的线性关系(r2≥0.9901); 3个水平(0.2、0.4、0.8 μg/L)下的添加回收率为60.1%~129.5%,相对标准偏差为1.1%~17.8%(n=6)。将所建立的方法用于来自大连市7个区的水样中PPCPs的筛查,共筛查出16种污染物,并对其进行了定量分析。本方法简单快速,灵敏度高,筛查范围广,为水质的管理和环境风险监测提供了一种有力的技术手段。  相似文献   

13.
As a suitable way for routine screening of pesticides and control of other organic contaminants in water, the combination of liquid chromatography triple quadrupole tandem mass spectrometry (LC–QqQ-MS/MS) and liquid chromatography–hybrid quadrupole time-of-flight mass spectrometry (LC–QTOF-MS) has been applied to the analysis of 63 surface and waste water samples after conventional solid-phase extraction (SPE). The extracts were screened for 43 pesticides or degradation products by LC–QqQ-MS/MS achieving limits of detection (LOD) ranged from 0.04 to 2 ng L−1. Of the 43 selected pesticides, 33 were detected in water samples. The ESI–QTOF MS instrument was run using two simultaneous acquisition functions with low and high collision energy (MSE approach) and acquiring the full mass spectra. A home-made database containing more than 1100 organic pollutants was used for substance identification. Around 250 of these compounds were available at the laboratory as reference standards. Five pesticides and 3 of their degradation products, different to those selected in the QqQ method, were detected by QqTOF-MS. Thirteen pharmaceuticals and two drugs of abuse were also identified in the samples. In practice, the sample preparation proved to be suitable for both techniques and for a wide variety of substances with different polarity. Mutual confirmation and evidence of co-occurrence of several other organic contaminants were the main advantages of the combination of both techniques.  相似文献   

14.
Zhao Y  Yang M  Zhang F  Feng F  Chu X  Dong Y 《色谱》2011,29(7):631-636
建立了奶酪样品中29种禁用和限用合成色素的液相色谱/四极杆-飞行时间质谱(LC/Q-TOF MS)筛查方法。样品经正己烷-水(3:1, v/v)振荡提取,得到正己烷层、水层和残渣3部分。正己烷层经旋转蒸发浓缩后,用乙酸乙酯-环己烷(1:1, v/v)溶解,经过凝胶渗透色谱(GPC)净化去除油脂。水层经乙腈振荡提取,得到乙腈-水提取液。残渣经氨水-甲醇(1:99, v/v)溶液振荡提取,得到氨水-甲醇提取液。乙腈-水提取液和氨水-甲醇提取液不需净化直接分析。结果表明: 29种不同极性范围的合成色素化合物分别得到了有效的提取,提取回收率为70%~95%。而Q-TOF MS提供的精确质量数定性功能可以将不同种类的合成色素化合物筛查出来,各化合物与精确质量质谱库中化合物的匹配度为59.66~99.47。通过Target MS/MS扫描方式进行定量,得到8种苏丹类化合物的方法检出限为0.4~2.5 μg/kg, 21种水溶性合成色素及染料化合物的检出限为20~80 μg/kg。该方法对禁用和限用合成色素的筛查范围广泛,对含有蛋白质、脂肪等基质的食品具有较好的适用性。  相似文献   

15.
An approach for the identification of multiple components in traditional Chinese medicine injections (TCMIs) using a combination of hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) coupled with time-of-flight mass spectrometry (TOFMS) was developed for the quality control of Guanxinning injection (GXNI), a widely used TCMI, composed of Salvia miltiorrhiza and Ligusticum Chuanxiong. A total of 50 compounds from five compound classes, including saccharides, amino acids, organic acids, phenolic acids and phthalides, were identified or tentatively characterized on the basis of accurate mass measurements and subsequent TOFMS product ions. Six groups of isomers of phenolic acids and saccharides were tentatively distinguished. It was observed that the ESI-TOFMS fragmentation behavior of phthalides was different in negative and positive ion mode, and the fragmentation pathways were tentatively elucidated using structurally-relevant product ions. Several highly polar constituents were characterized for the first time from GXNI by HILIC/TOFMS. In addition, all the constituents identified from GXNI were further assigned in the two individual crude drugs. The integrated strategy has provided a powerful approach for the separation and identification of the multiple components in GXNI, and it has also assisted in the establishment of methods for the comprehensive safety and quality evaluation of TCMIs.  相似文献   

16.
Analysis of the major drugs of abuse in meconium has been established in clinical practice for detecting fetal exposure to illicit drugs, particularly for the ready availability of the sample and ease of collection from diapers, compared with neonatal hair and urine. Very little is known about the occurrence and detection possibilities of therapeutic and licit drugs in meconium. Meconium specimens (n = 209) were collected in delivery hospitals, from infants of mothers who were suspected to be drug abusers. A targeted analysis method by liquid chromatography–triple quadrupole mass spectrometry (LC-MS/MS) was developed for abused drugs: amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, morphine, codeine, 6-monoacetylmorphine, oxycodone, methadone, tramadol, buprenorphine, and norbuprenorphine. A separate LC-MS/MS method was developed for 11-nor-∆9-tetrahydrocannabinol-9-carboxylic acid. A screening method based on LC coupled to time-of-flight MS was applied to a broad spectrum of drugs. As a result, a total of 77 different compounds were found. The main drug findings in meconium were as follows: local anesthetics 82.5% (n = 172), nicotine or its metabolites 61.5% (n = 129), opioids 48.5% (n = 101), stimulants 21.0% (n = 44), hypnotics and sedatives 19.0% (n = 40), antidepressants 18.0% (n = 38), antipsychotics 5.5% (n = 11), and cannabis 3.0% (n = 5). By revealing drugs and metabolites beyond the ordinary scope, the present procedure helps the pediatrician in cases where maternal denial is strong but the infant seems to suffer from typical drug-withdrawal symptoms. Intrapartum drug administration cannot be differentiated from gestational drug use by meconium analysis, which affects the interpretation of oxycodone, tramadol, fentanyl, pethidine, and ephedrine findings.  相似文献   

17.
A liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) method was developed using the latest high-resolution LC column technology, the ultra performance liquid chromatography (UPLC), and electrospray ionization (ESI) in the positive ion mode. Gradient UPLC separation conditions were optimized for a group of 22 analytes comprising 17 glucocorticosteroids, specific designer steroids such as tetrahydrogestrinone (THG) and specific beta2-agonists such as formoterol. The UPLC/TOFMS separation obtained required 5.5 min only for all the substances tested. Even the critical pair of dexamethasone and betamethasone isomers was almost completely resolved. Thanks to the over 10,000 full-width at half maximum (FWHM) mass resolution and high mass accuracy features of TOFMS 50 mDa window accurate mass chromatograms could be reconstructed for the individual analytes. Sensitive screening in human and calf urine samples fortified at the glucocorticosteroids minimum required performance limit (MRPL) of 30 microg L(-1) (human urine, sports doping) and 2 microg L(-1) (calf urine, veterinary control) could be obtained. The potential of UPLC/TOFMS for confirmatory analysis was shown by determining the accurate mass of all compounds and fragment ions upon in-source collision-induced dissociation (CID) at different energies. The exact mass measurement errors for all glucocorticosteroids were found to be within 6 ppm. Considering veterinary control, limits of detection (LOD) and limits of quantification (LOQ) were determined for most of the analytes in calf urine and found to range from 0.1 to 3.3 and from 0.4 to 4.4 microg L(-1), respectively. The method can be easily extended with other banned substances of interest, as demonstrated by the addition of 21 beta2-agonists to the original analyte mixture in urine, without causing any interferences.  相似文献   

18.
A method was developed for the extraction of stanozolol, taleranol, zeranol, hexestrol, dienestrol, ethynylestradiol, diethylstilbestrol, and trenbolone from animal urine. The analytes were extracted from the matrix by enzymatic hydrolysis, solid-phase extraction, and liquid-liquid extraction. Detection and quantitation were performed on a high-performance liquid chromatography system coupled to a triple quadrupole mass spectrometer. The identification criteria met the European Union regulations. Validation of this method established a decision limit between 0.2 and 0.9 microg/L and a detection capability between 0.3 and 1.0 microg/L, depending on the analyte.  相似文献   

19.
Gestrinone was studied by high performance liquid chromatography (HPLC) for screening and by gas chromatography/mass spectrometry (GC/MS) for confirmation. When the chromatograms of blank, spiked urine and dosed urine were compared by HPLC, two unknown metabolites were found and these were excreted as the conjugated forms. Metabolites 1 and 2 were tested by LC/MS and LC/MS/MS and both had parent ions at m/z 325. The fragment ion of metabolite 1 was at m/z 263 and ions for metabolite 2 were m/z 307 [MH - H(2)O](+), 289, 279 and 241. LC/MS/MS of m/z 263 as the parent ion of metabolite 1 gave fragment ions at m/z 245 and 217, which were assumed to be [263 - H(2)O](+) and [235 - H(2)O](+), respectively. The trimethylsilyl (TMS)-enol-TMS ether derivative of gestrinone displayed three peaks in its GC/MS chromatogram, formed by tautomerism.  相似文献   

20.
The resource investment required to characterise the metabolic fate of a compound is relatively large, meaning that within a drug discovery environment relatively few compounds are characterised in depth. Rate-limiting steps include the setting up of a complex array of mass spectrometry experiments and the subsequent analysis of the large data sets produced. We describe here a strategy for the evaluation of metabolic routes using full-scan high-resolution liquid chromatography/quadrupole time-of-flight mass spectrometry (LC/QToFMS) with automated data analysis using Metabolynx, a commercially available software package. Data from several structurally diverse compounds taken from the literature illustrate that, with careful setting of key parameters, this approach is able to indicate the presence of a wide range of metabolites with only a limited requirement for manual intervention.  相似文献   