首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A major disadvantage of gradient elution in terms of speed results from the need to adequately re-equilibrate the column. This work distinguishes two states of re-equilibration: (1) run-to-run repeatability and (2) full equilibration. We find that excellent repeatability (+/-0.002 min in retention time) is achieved with at most 2 column volumes of re-equilibration whereas full equilibration can require considerably more than 20 column volumes. We have investigated the effects of adding ancillary solvents (e.g. n-propanol, n-butanol) to the eluent and changing the particle pore size, initial eluent composition and type, column temperature and flow rate on the speed of full equilibration. Full equilibration seems to be more thermodynamically limited than kinetically controlled. Also, we show that the main limitation to reducing the full equilibration time is related to instrument design issues; a novel approach to overcome these instrumental issues is described.  相似文献   

2.
The fundamental equations and conditions for linear and stepwise gradient elution in reversed-phase liquid chromatography are applied to a mixture of amino acids in their underivatized form in aqueous mobile phases modified by 2-propanol, acetonitrile or methanol for examining column equilibration effects. It was found in all cases systematic deviations between experimental and calculated retention times, which are prominent in 2-propanol, reduced in acetonitrile and practically negligible in methanol. These deviations appear within a chromatogram just after the first change in the composition of the mobile phase reaches the detector and last ca. 5 min, where the magnitude of errors reduces exponentially with time. Based on these observations we propose a simple way to correct the calculated from the gradient elution theory retention times of sample solutes. The origin of the discrepancies between theory and experiment as well as their impact on the resolution is also discussed.  相似文献   

3.
An optimisation technique of reversed-phase liquid chromatographic separations based on gradient elution with a stepwise variation pattern of the volume fraction phi of the organic modifier in the water-organic mobile phase is presented. It uses a non-linear least-squares programme with a Monte-Carlo search for initial estimates in order to determine the best variation pattern that leads to the optimum separation of a mixture of solutes. The validity of the above methodology was tested by separating eight catechol-related solutes with mobile phases modified by methanol or acetonitrile and variation patterns of two, three or four steps in the psi values. It was found in all cases a very satisfactory accuracy of the predicted gradient elution times, which is of the same order with the accuracy of the retention times predicted under isocratic or linear gradient conditions. In addition, it was shown that the proposed optimisation technique is both effective and flexible but well-shaped chromatograms are obtained under electrochemical detection only if steps with increasing psi are used and the change in psi is programmed to occur at the intermediate of the predicted peaks.  相似文献   

4.
5.
The treatment presented in a recent paper [P. Nikitas, A. Pappa-Louisi, J. Chromatogr. A, 1068 (2005) 279] is extended to multilinear gradients, i.e. continuous gradients consisting of a certain number of linear portions. Thus, the experimental lnk versus phi curve, where k is the retention factor of a sample solute under isocratic conditions and phi is the volume fraction of the organic modifier in the water-organic mobile phase, is subdivided into a finite number of linear portions resulting in simple analytical expressions for the solute gradient retention time. These expressions of the retention time are directly used in an optimisation technique based on genetic algorithms. This technique involves first the determination of the theoretical dependence of k upon phi by means of gradient measurements, which in turn is used by the genetic algorithm for the prediction of the best gradient profile. The validity of the analytical expressions and the effectiveness of the optimisation technique were tested using fifteen underivatized amino acids and related compounds with mobile phases modified by acetonitrile. It was found that the adopted methodology exhibits significant advantages and it can lead to high quality predictions of the gradient retention times and optimisation results.  相似文献   

6.
One- and multi-variable retention models proposed for isocratic and/or gradient elution in reversed-phase liquid chromatography are critically reviewed. The thermodynamic, exo-thermodynamic or empirical arguments adopted for their derivation are presented and discussed. Their connection to the retention mechanism is also indicated and the assumptions and approximations involved in their derivation are stressed. Special attention is devoted to the fitting performance of the various models and its impact on the final predicted error between experimental and calculated retention times. The possibility of using exo-thermodynamic retention models for prediction under gradient elution is considered from a practical point of view. Finally, the use of statistical weights in the fitting procedure of a retention model and its effect on the calculated elution times as well as the transferability of retention data among isocratic and gradient elution modes are also examined and discussed.  相似文献   

7.
Summary Equations describing multi-step gradient elution with a mobile phase of constant composition in each step were derived. These equations useful for calculating the retention volumes in both gradient HPLC and TLC were derived on the basis of the relationship between the isocratic capacity factor and the volume fraction of the organic modifier. The validity of the equations was experimentally verified in a LiChrosorbRP-18-water/methanol system for 11 methyl- and chlorobenzenes and phenols. A satisfactory agreement between the theoretical and experimental k′ values was found.  相似文献   

8.
Elution time shifts between 33 different peptides and their corresponding phosphopeptides ranging from 4 amino acid residues to 35 amino acids in length were systematically investigated using high-resolution reversed-phase liquid chromatography (RPLC)-tandem mass spectrometry (MS/MS) analysis with trifluoroacetic acid as the ion pairing agent. Observed peptide elution time shifts for a single phosphorylation ranged from -5.28 min (for pYVPML) to +0.59 min (for HRDpSGLLDSLGR). Peptides containing a phosphotyrosine residue displayed a significant decrease in elution time following phosphorylation compared to their similar-sized peptides with phosphoserine or phosphothreonine residues. While peptide phosphorylation generally led to a decrease in the observed elution time, five peptides displayed increased elution times as a result of phosphorylation. For large peptides (> or =18 amino acids), the elution time shifts due to single phosphorylation were limited (ranging between -0.48 and +0.03 min), while the elution time shifts for small peptides (<18 amino acids) were characterized by a larger deviation (ranging between -5.28 and +0.59 min). The predictive capability for the observed RPLC elution time change due to phosphorylation has been suggested, which will aid in assigning confident phosphopeptide identifications and their subsequent confirmation.  相似文献   

9.
A new mathematical treatment concerning the gradient elution in reversed-phase liquid chromatography when the volume fraction psi of an organic modifier in the water-organic mobile phase varies linearly with time is presented. The experimental ln k versus psi curve, where k is the retention factor under isocratic conditions in a binary mobile phase, is subdivided into a finite number of linear portions and the solute gradient retention time tR is calculated by means of an analytical expression arising from the fundamental equation of gradient elution. The validity of the proposed analytical expression and the methodology followed for the calculation of tR was tested using eight catechol-related solutes with mobile phases modified by methanol or acetonitrile. It was found that in all cases the accuracy of the predicted gradient retention times is very satisfactory because it is the same with the accuracy of the retention times predicted under isocratic conditions. Finally, the above method for estimating gradient retention times was used in an optimisation algorithm, which determines the best variation pattern of psi that leads to the optimum separation of a mixture of solutes at different values of the total elution time.  相似文献   

10.
Typical refractive index (RI) detectors for liquid chromatography (LC) are not well suited to application with mobile phase gradient elution, due to the difficulty in correcting for the detected baseline shift during the gradient. We report a sensitive, highly reproducible, microfabricated refractive index gradient (micro-RIG) detector that performs well with mobile phase gradient elution LC. Since the micro-RIG signal remains on-scale throughout the mobile phase gradient, one can apply a baseline correction procedure. We demonstrate that by collecting two mobile phase gradient blanks and subtracting one of them from the other, a reproducible, flat baseline is achieved. Therefore, subtracting a blank from a separation provides a baseline corrected chromatogram with reasonably high signal-to-noise ratio for eluting analytes. The micro-RIG detector uses a collimated diode laser beam to optically probe a RIG formed perpendicular to the laminar flow direction within a microfabricated borosilicate glass chip. The chip-based design of the detector is suitable for either traditional bench-top or LC-on-a-chip technologies. We report reversed phase high performance liquid chromatography (RP-HPLC) separations of proteins and polymers, over mobile phase gradient conditions of 67% A:33% B to 3% A:97% B by volume, where A is 96% methanol:3.9% water:0.1% trifluoroacetic acid (TFA), and B is 3.9% methanol:96% water:0.1% TFA. The separations were performed on a Jupiter 5 mu C4 300 A 150 mm x 1.0 mm Phenomenex column at a flow rate of 20 microl/min. Viscosity changes during the mobile phase gradient separation are found to shift the on-chip merge position of the detected concentration gradient (i.e., RIG), in a reproducible fashion. However, this viscosity effect makes detection sensitivity vary throughout the mobile phase gradient, due to moving the optimized position of the probe beam in relation to the analyte concentration gradient being probed. None-the-less, consistent limits of detection (LODs) were achieved. The 3-sigma deflection angle LOD was 16 microrad for micro-RIG detection, corresponding to an injected concentration LOD of 7 ppm (mass/mass) for cytochrome c.  相似文献   

11.
The Reversed-phase (RP) gradient elution chromatography of nociceptin/orphanin FQ (N/OFQ), a neuropeptide with many biological effects, has been modeled under linear and non-linear conditions. In order to do this, the chromatographic behavior has been studied under both linear and nonliner conditions under isocratic mode at different mobile phase compositions--ranging from 16 to 19% (v/v) acetonitrile (ACN) in aqueous trifluoracetic acid (TFA) 0.1% (v/v)-on a C-8 column. Although the range of mobile phase compositions investigated was quite narrow, the retention factor of this relatively small polypeptide (N/OFQ is a heptadecapeptide) has been found to change by more than 400%. In these conditions, gradient operation resulted thus to be the optimum approach for non-linear elution. As the available amount of N/OFQ was extremely reduced (only a few milligrams), the adsorption isotherms of the peptide, at the different mobile phase compositions examined, have been measured through the so-called inverse method (IM) on a 5 cm long column. The adsorption data at different mobile phase compositions have been fitted to several models of adsorption. The dependence of the isotherm parameters on the mobile phase composition was modeled by using the linear solvent strength (LSS) model and a generalized Langmuir isotherm that includes the mobile phase composition dependence. The overloaded gradient separation of N/OFQ has been modeled by numerically solving the equilibrium-dispersive (ED) model of chromatography under a selected gradient elution mode, on the basis of the previously determined generalized Langmuir isotherm. The agreement between theoretical calculations and experimental overloaded band profiles appeared reasonably accurate.  相似文献   

12.
The theory of the multilinear gradient elution in reversed-phase liquid chromatography (RP-HPLC) presented in [P. Nikitas, A. Pappa-Louisi, P. Agrafiotou, J. Chromatogr. A 1120 (2006) 299] is modified to increase its flexibility. In addition, it is embodied to simple algorithms for fitting gradient data and especially for resolution optimisation under multilinear gradient conditions. In particular, two new algorithms for fitting and one for optimisation are tested and compared with conventional algorithms. Their performance was examined using 13 o-phthalaldehyde (OPA) derivatives of amino acids with mobile phases modified by acetonitrile. It was found that the new proposed algorithms, a repeated application of the Levenberg-Marquardt (LM) method for fitting (R_LM) and a modified descent algorithm for optimisation (RND_D), in combination with the modified theory of the multilinear gradient elution can lead to high quality predictions of the retention times and optimisation results.  相似文献   

13.
Previous reports suggest that peak widths in linear gradient elution are consistently larger than predicted by theory; however, if gradient compression is ignored, experiment and theory are in reasonable agreement. This suggests that gradient compression might represent an incorrect or poorly understood concept. In the present study, an experimental program was carried out to better understand the role of gradient compression and the reason for past differences between experiment and theory. It is concluded that the concept of gradient compression is correct.  相似文献   

14.
A new approach to high speed, comprehensive online dual gradient elution 2DLC (LCxLC) based on the use of ultra-fast, high temperature gradient elution reversed phase chromatography is described. Entirely conventional gradient elution instrumentation and columns are assembled in a system which develops a total peak capacity of about 900 in 25 min; this is equivalent to roughly one peak/2 s. Each second dimension gradient is done in a cycle time of 21 s and the peak retention times measured for a set of twenty six indole-3-acetic acid (IAA) derivatives are reproducible to 0.2 s. Each peak eluting from the first dimension column is sampled at least twice across its width, as the corresponding peaks on the second dimension column appear in two or three consecutive second dimension chromatograms, clearly indicating that there is little loss in the resolution gained in the first dimension separation. Application to the separation of the low molecular weight components of wild-type and mutant maize seedlings indicates the presence of about 100 peaks on a timescale of 25 min. Compelling illustrations of the analytical potential of fast, high temperature 2DLC are evident in the clear presence of nine distinct peaks in a single second dimension chromatogram from a single quite narrow first dimension peak, and the great power of 2DLC to solve the "analytic dynamic range" problem inherent in the measurement of small peaks that are neighbors to a gigantic peak.  相似文献   

15.
The effect of mobile phase modifier and temperature on gradient reequilibration is examined using three different stationary phases. The stationary phases studied are a traditional C18 phase, a polar endcapped C18 phase, and an alkyl phase with a polar embedded group. It was observed that both temperature and choice of mobile phase organic modifier had an effect on gradient reequilibration volume on both the traditional C18 stationary phase and the polar endcapped phase. On both these phases, at any given temperature, the reequilibration volume was generally smaller when methanol was used as the mobile phase modifier as compared to acetonitrile. As the temperature is increased from 10 to 50 degrees C, significant reductions in reequilibration volume were observed with both mobile phase modifiers. In contrast, neither temperature nor choice of modifier appeared to have much effect on reequilibration volume when the polar embedded group stationary phase was considered.  相似文献   

16.
The performance of 5 and 15 cm long columns packed with shell particles (Halo, AMT) is compared in gradient elution separations of the tryptic digests of myoglobin and bovine serum albumin. The influences of the temperature and the mobile phase flow rate on the column efficiency for two peptides are discussed. The influences of this flow rate, of the temperature, and of the gradient slopes on the peak capacities are also considered. Peak capacities in excess of 400 were achieved in 6h with the longer column. Peak capacities of 200 could be achieved in 30 min with the shorter column.  相似文献   

17.
The concept of limiting peak purity was applied to quantify the degree of completion of the separation capability of a chromatographic system using multi-linear gradients. The objective was to check whether the complexity of a gradient program deserves be increased to enhance resolution by inserting more linear segments, or on the contrary, no significant improvements can be expected under more complex gradients. A set of 19 isoindole derivatives of primary amino acids was selected to test the performance of isocratic, single linear and multi-linear gradients. Accurate simulated chromatograms were obtained via numerical integration of the general equation of gradient elution, using pre-established start and end conditions of the gradient program. The overall peak purity was selected as objective function. Good--although not baseline--resolution was achieved with an optimal trilinear gradient. Excellent agreement between experimental and predicted optimal chromatograms was found. With the proposed approach, a degree of completion of the separation capability of the chromatographic system of 21.2, 49.7, 81.5 and 88.5% was accomplished with optimal gradients with one, two, three and four segments, respectively. More complex gradients did not enhance the latter figure significantly. Also, multi-linear gradients gave rise to more benefits than complementary gradients.  相似文献   

18.
郝卫强  刘丽娟  沈巧银 《色谱》2021,39(1):10-14
谱带压缩效应是梯度洗脱区别于等度洗脱的重要特征。经典的范德姆特(van Deemter)理论塔板高度方程基于等度洗脱推导得到,因此不能对谱带压缩效应进行描述。在梯度洗脱中,保留因子(k)会随流动相组成(φ)的改变而发生变化,这就使得对梯度洗脱机理的研究要比等度洗脱复杂许多。该文对近10年来谱带压缩效应的研究进展,特别是溶剂强度模型(即描述ln kφ关系的数学表达式)的非线性特征对谱带压缩因子(G)的影响进行了述评,指出为了更好地认识谱带压缩效应需要将这种非线性因素考虑在内。  相似文献   

19.
20.
Gradient elution is widely applied in analytical chromatography to reduce the separation time and/or to improve the selectivity. Increasingly the potential of modulating the solvent strength during gradient operation is exploited in preparative liquid chromatography. The purpose of this paper is to investigate theoretically the effect of optimizing free parameters available in gradient chromatography (extents and shapes of gradients) on the productivity of isolating a target component in a multicomponent mixture. An equilibrium stage model was used to quantify and compare different modes of operation (isocratic and various variants of gradient elution). By combining experimental design and artificial neural network concepts, optimal conditions were identified for the production of the second eluting component in a ternary mixture. The strong impact of the shape of gradients on process performance is elucidated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号