首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A picosecond‐resolving hard‐X‐ray streak camera has been in operation for several years at Sector 7 of the Advanced Photon Source (APS). Several upgrades have been implemented over the past few years to optimize integration into the beamline, reduce the timing jitter, and improve the signal‐to‐noise ratio. These include the development of X‐ray optics for focusing the X‐rays into the sample and the entrance slit of the streak camera, and measures to minimize the amount of laser light needed to generate the deflection‐voltage ramp. For the latter, the photoconductive switch generating the deflection ramp was replaced with microwave power electronics. With these, the streak camera operates routinely at 88 MHz repetition rate, thus making it compatible with all of the APS fill patterns including use of all the X‐rays in the 324‐bunch mode. Sample data are shown to demonstrate the performance.  相似文献   

2.
A commercial fuel cell has been successfully modified to carry out X‐ray absorption spectroscopy (XAS) measurements under optimized in operando conditions. The design is conceived for the performance of XAS experiments in transmission mode over a wide range of X‐ray energies above 6 keV, owing to the reduced absorption of the cell. The wide angular aperture allows the collection of XAS in fluorescence mode and of X‐ray diffraction patterns when needed. Details of the design of the cell and its performances are given. The quality of the extended X‐ray absorption fine‐structure spectra under working conditions has been verified at the ESRF and ELETTRA synchrotron radiation facilities, showing that relatively fast and low‐noise transmission measurements on electrodes over a wide range of catalyst concentrations and energies are feasible.  相似文献   

3.
The molecular structure of lubricating motor oils is investigated by X‐ray absorption fine structure spectroscopy measurements. Both fresh and used oils are studied. Although the Zn K‐edge spectra gave information about the degradation of the antiwear/antioxidant zinc dialkyl dithiophosphate (ZDDP) additives within the oil, Fe K‐edge spectra are representatives for iron species dispersed in the oil during operation at elevated temperatures and pressures in the engine. The detailed analysis of the measured data shows that substantial differences are detectable in the spectra of the fresh and used oil. Our results show that the Zn–S bonds of the ZDDP are decomposed during the operation, resulting in Zn–O bonds instead. Furthermore, sixfold Fe–O bonds similar to those in Fe2O3 are found within the used oil, suggesting the presence of debris from the antiwear film of lubricated motor parts in the used oil. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
Full‐field X‐ray absorption spectroscopy experiments allow the acquisition of millions of spectra within minutes. However, the construction of the hyperspectral image requires an image alignment procedure with sub‐pixel precision. While the image correlation algorithm has originally been used for image re‐alignment using translations, the Scale Invariant Feature Transform (SIFT) algorithm (which is by design robust versus rotation, illumination change, translation and scaling) presents an additional advantage: the alignment can be limited to a region of interest of any arbitrary shape. In this context, a Python module, named SIFT_PyOCL, has been developed. It implements a parallel version of the SIFT algorithm in OpenCL, providing high‐speed image registration and alignment both on processors and graphics cards. The performance of the algorithm allows online processing of large datasets.  相似文献   

5.
In the past seven years the size of the known protein sequence universe has been rapidly expanding. At present, more then five million entries are included in the UniProtKB/TrEMBL protein database. In this context, a retrospective evaluation of recent X‐ray absorption studies is undertaken to assess its potential role in metalloproteomics. Metalloproteomics is the structural and functional characterization of metal‐binding proteins. This is a new area of active research which has particular relevance to biology and for which X‐ray absorption spectroscopy is ideally suited. In the last three years, biological X‐ray absorption spectroscopy (BioXAS) has been included among the techniques used in post‐genomics initiatives for metalloprotein characterization. The emphasis of this review is on the progress in BioXAS that has emerged from recent meetings in 2007–2008. Developments required to enable BioXAS studies to better contribute to metalloproteomics throughput are also discussed. Overall, this paper suggests that X‐ray absorption spectroscopy could have a higher impact on metalloproteomics, contributing significantly to the understanding of metal site structures and of reaction mechanisms for metalloproteins.  相似文献   

6.
X‐ray reflectivity studies of the structure of liquid–vapour and liquid–liquid interfaces at modern sources, such as free‐electron lasers, are currently impeded by the lack of dedicated liquid surface diffractometers. It is shown that this obstacle can be overcome by an alternative experimental approach that uses the natural curvature of a liquid drop for variation of the angle of incidence. Two modes of operation are shown: (i) sequential reflectivity measurements by a nanometre beam and (ii) parallel acquisition of large ranges of a reflectivity curve by micrometre beams. The feasibility of the two methods is demonstrated by studies of the Hg/vapour, H2O/vapour and Hg/0.1 M NaF interface. The obtained reflectivity curves match the data obtained by conventional techniques up to 5αc in micro‐beam mode and up to 35αc in nano‐beam mode, allowing observation of the Hg layering peak.  相似文献   

7.
The crystal and local atomic structure of monoclinic ReO2 (α‐ReO2) under hydrostatic pressure up to 1.2 GPa was investigated for the first time using both X‐ray absorption spectroscopy and high‐resolution synchrotron X‐ray powder diffraction and a home‐built B4C anvil pressure cell developed for this purpose. Extended X‐ray absorption fine‐structure (EXAFS) data analysis at pressures from ambient up to 1.2 GPa indicates that there are two distinct Re—Re distances and a distorted ReO6 octahedron in the α‐ReO2 structure. X‐ray diffraction analysis at ambient pressure revealed an unambiguous solution for the crystal structure of the α‐phase, demonstrating a modulation of the Re—Re distances. The relatively small portion of the diffraction pattern accessed in the pressure‐dependent measurements does not allow for a detailed study of the crystal structure of α‐ReO2 under pressure. Nonetheless, a shift and reduction in the (011) Bragg peak intensity between 0.4 and 1.2 GPa is observed, with correlation to a decrease in Re—Re distance modulation, as confirmed by EXAFS analysis in the same pressure range. This behavior reveals that α‐ReO2 is a possible inner pressure gauge for future experiments up to 1.2 GPa.  相似文献   

8.
The first application of a pnCCD detector for X‐ray scattering experiments using white synchrotron radiation at BESSY II is presented. A Cd arachidate multilayer was investigated in reflection geometry within the energy range 7 keV < E < 35 keV. At fixed angle of incidence the two‐dimensional diffraction pattern containing several multilayer Bragg peaks and respective diffuse‐resonant Bragg sheets were observed. Since every pixel of the detector is able to determine the energy of every incoming photon with a resolution ΔE/E? 10?2, a three‐dimensional dataset is finally obtained. In order to achieve this energy resolution the detector was operated in the so‐called single‐photon‐counting mode. A full dataset was evaluated taking into account all photons recorded within 105 detector frames at a readout rate of 200 Hz. By representing the data in reciprocal‐space coordinates, it becomes obvious that this experiment with the pnCCD detector provides the same information as that obtained by combining a large number of monochromatic scattering experiments using conventional area detectors.  相似文献   

9.
Combined X‐ray photon correlation spectroscopy (XPCS) and diffracted X‐ray tracking (DXT) measurements of carbon‐black nanocrystals embedded in styrene–butadiene rubber were performed. From the intensity fluctuation of speckle patterns in a small‐angle scattering region (XPCS), dynamical information relating to the translational motion can be obtained, and the rotational motion is observed through the changes in the positions of DXT diffraction spots. Graphitized carbon‐black nanocrystals in unvulcanized styrene–butadiene rubber showed an apparent discrepancy between their translational and rotational motions; this result seems to support a stress‐relaxation model for the origin of super‐diffusive particle motion that is widely observed in nanocolloidal systems. Combined measurements using these two techniques will give new insights into nanoscopic dynamics, and will be useful as a microrheology technique.  相似文献   

10.
A bent‐crystal spectrometer based on the Rowland circle geometry has been installed and tested on the BM30b/FAME beamline at the European Synchrotron Radiation Facility to improve its performances. The energy resolution of the spectrometer allows different kinds of measurements to be performed, including X‐ray absorption spectroscopy, resonant inelastic X‐ray scattering and X‐ray Raman scattering experiments. The simplicity of the experimental device makes it easily implemented on a classical X‐ray absorption beamline. This improvement in the fluorescence detection is of particular importance when the probed element is embedded in a complex and/or heavy matrix, for example in environmental sciences.  相似文献   

11.
12.
An X‐ray fluorescence flow cytometer that can determine the total metal content of single cells has been developed. Capillary action or pressure was used to load cells into hydrophilic or hydrophobic capillaries, respectively. Once loaded, the cells were transported at a fixed vertical velocity past a focused X‐ray beam. X‐ray fluorescence was then used to determine the mass of metal in each cell. By making single‐cell measurements, the population heterogeneity for metals in the µM to mM concentration range on fL sample volumes can be directly measured, a measurement that is difficult using most analytical methods. This approach has been used to determine the metal composition of 936 individual bovine red blood cells (bRBC), 31 individual 3T3 mouse fibroblasts (NIH3T3) and 18 Saccharomyces cerevisiae (yeast) cells with an average measurement frequency of ~4 cells min?1. These data show evidence for surprisingly broad metal distributions. Details of the device design, data analysis and opportunities for further sensitivity improvement are described.  相似文献   

13.
The SUT‐NANOTEC‐SLRI beamline was constructed in 2012 as the flagship of the SUT‐NANOTEC‐SLRI Joint Research Facility for Synchrotron Utilization, co‐established by Suranaree University of Technology (SUT), National Nanotechnology Center (NANOTEC) and Synchrotron Light Research Institute (SLRI). It is an intermediate‐energy X‐ray absorption spectroscopy (XAS) beamline at SLRI. The beamline delivers an unfocused monochromatic X‐ray beam of tunable photon energy (1.25–10 keV). The maximum normal incident beam size is 13 mm (width) × 1 mm (height) with a photon flux of 3 × 108 to 2 × 1010 photons s?1 (100 mA)?1 varying across photon energies. Details of the beamline and XAS instrumentation are described. To demonstrate the beamline performance, K‐edge XANES spectra of MgO, Al2O3, S8, FeS, FeSO4, Cu, Cu2O and CuO, and EXAFS spectra of Cu and CuO are presented.  相似文献   

14.
A specimen containing nanograms of Sb, rare earth elements, Pb, and Bi and a specimen containing a few nanograms each of As and Pb were measured using a portable total reflection X‐ray fluorescence spectrometer. Nanograms of Sb, rare earth elements, Pb, and Bi were detected. Although the As Kα line (10.54 keV) overlapped with the Pb Lα line (10.55 keV) in a spectrum of the specimen containing nanograms of As and Pb, the Pb Lβ line was detected. Therefore, the net intensity of the As Kα line was calculated using the Pb Lα/Lβ intensity ratio in a spectrum of a Pb standard solution and the net intensity of the Pb Lβ line in the spectrum of the specimen containing As and Pb. This result indicates that these two elements can be quantified by using the portable spectrometer. Commercially available bottled drinking water was also measured. The portable spectrometer detected several tens of ppb of V in the drinking water sample. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
A new program called miXAFS for the analysis of X‐ray absorption fine‐structure (XAFS) data is presented. miXAFS can analyze the XAFS functions simultaneously for all measured X‐ray absorption edges of the constituent elements in a sample under the constraints for the structural parameters over the edges. The program provides a surface plot of the R‐factor as a function of two structural parameters, which is useful to validate the optimized structural parameters. The structural parameters can be obtained from the XAFS data in a few steps using the setting file and batch process. The program, which is coded in MATLAB and freely available, runs on Macintosh and Windows operating systems. It has a graphical user interface and loads experimental data and XAFS functions in a variety of ASCII data formats.  相似文献   

16.
Spray deposition of thin films and coatings is a widely used manufacturing process owing to its low cost, versatility and simple implementation. The objective of the presented experiments was to investigate whether X‐ray absorption measurements on solutes carried by aerosols are possible, and what count rates can be achieved depending on solution flow through and the resulting mass density in the interrogation volume. The investigated prototypical spray aerosol was InCl3 dissolved in water or ethanol dispersed via an ultrasonic nebulizer. InCl3 spray is essential for the ion layer gas reaction process used for the deposition of In2S3 buffer layers for highly efficient chalcopyrite solar cells. The discussed experiments demonstrate that measurements are possible, but that the achievement of good signal‐to‐noise ratios requires extended sampling times and concentrated solutions.  相似文献   

17.
A new theoretical approach and computational package, FDMX, for general calculations of X‐ray absorption fine structure (XAFS) over an extended energy range within a full‐potential model is presented. The final‐state photoelectron wavefunction is calculated over an energy‐dependent spatial mesh, allowing for a complete representation of all scattering paths. The electronic potentials and corresponding wavefunctions are subject to constraints based on physicality and self‐consistency, allowing for accurate absorption cross sections in the near‐edge region, while higher‐energy results are enabled by the implementation of effective Debye–Waller damping and new implementations of second‐order lifetime broadening. These include inelastic photoelectron scattering and, for the first time, plasmon excitation coupling. This is the first full‐potential package available that can calculate accurate XAFS spectra across a complete energy range within a single framework and without fitted parameters. Example spectra are provided for elemental Sn, rutile TiO2 and the FeO6 octahedron.  相似文献   

18.
《X射线光谱测定》2006,35(2):101-105
Titanium oxide grafted on to the surfaces of chromatographic silica was investigated by x‐ray fluorescence (XRF) and x‐ray absorption (XAS) spectroscopy and the latter used before and after the extensive use of this material as a support for reversed‐phase high‐performance liquid chromatography (RP‐HPLC). XRF indicated the formation of a complete 2:1 monolayer whereas XAS suggested the presence of more than one titanium oxide structure. These structures show some slight modification after immobilization of PMOS and use in HPLC. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

19.
Suitability of polychromatic X‐rays has been assessed for the total reflection X‐ray fluorescence (TXRF) trace elemental determinations in aqueous solutions as well as uranium oxide certified reference materials. The method involves total reflection of X‐rays below a certain energy level on the TXRF sample support and exciting the analytes present in ng amount on these supports, measuring the TXRF spectra, processing the spectra, and finally determining the elemental concentrations. For uranium‐based samples, the samples were dissolved, main matrix uranium was separated from these solutions using solvent extraction, and trace elements were determined using aqueous phase following above approach. The method is simple and easier to implement compared with the monochromatic excitation but has similar or in some cases better detection limits compared with those obtained using monochromatic excitation. The details of the methodology, quality of analytical results, and detection limits are described and compared with those obtained using monochromatic excitation. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

20.
A two‐dimensional imaging system of X‐ray absorption fine structure (XAFS) has been developed at beamline BL‐4 of the Synchrotron Radiation Center of Ritsumeikan University. The system mainly consists of an ionization chamber for I0 measurement, a sample stage, and a two‐dimensional complementary metal oxide semiconductor (CMOS) image sensor for measuring the transmitted X‐ray intensity. The X‐ray energy shift in the vertical direction, which originates from the vertical divergence of the X‐ray beam on the monochromator surface, is corrected by considering the geometrical configuration of the monochromator. This energy correction improves the energy resolution of the XAFS spectrum because each pixel in the CMOS detector has a very small vertical acceptance of ~0.5 µrad. A data analysis system has also been developed to automatically determine the energy of the absorption edge. This allows the chemical species to be mapped based on the XANES feature over a wide area of 4.8 mm (H) × 3.6 mm (V) with a resolution of 10 µm × 10 µm. The system has been applied to the chemical state mapping of the Mn species in a LiMn2O4 cathode. The heterogeneous distribution of the Mn oxidation state is demonstrated and is considered to relate to the slow delocalization of Li+‐defect sites in the spinel crystal structure. The two‐dimensional‐imaging XAFS system is expected to be a powerful tool for analyzing the spatial distributions of chemical species in many heterogeneous materials such as battery electrodes.  相似文献   