共查询到20条相似文献,搜索用时 11 毫秒
1.
Simultaneous X‐ray fluorescence and scanning X‐ray diffraction microscopy at the Australian Synchrotron XFM beamline 下载免费PDF全文
Michael W. M. Jones Nicholas W. Phillips Grant A. van Riessen Brian Abbey David J. Vine Youssef S. G. Nashed Stephen T. Mudie Nader Afshar Robin Kirkham Bo Chen Eugeniu Balaur Martin D. de Jonge 《Journal of synchrotron radiation》2016,23(5):1151-1157
Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X‐ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X‐ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super‐resolved ultra‐structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step‐ and fly‐scanning modes, robust, simultaneous XFM‐SXDM is demonstrated. 相似文献
2.
Gema Martínez‐Criado Rémi Tucoulou Peter Cloetens Pierre Bleuet Sylvain Bohic Jean Cauzid Isabelle Kieffer Ewelina Kosior Sylvain Labouré Sylvain Petitgirard Alexander Rack Juan Angel Sans Jaime Segura‐Ruiz Heikki Suhonen Jean Susini Julie Villanova 《Journal of synchrotron radiation》2012,19(1):10-18
The ESRF synchrotron beamline ID22, dedicated to hard X‐ray microanalysis and consisting of the combination of X‐ray fluorescence, X‐ray absorption spectroscopy, diffraction and 2D/3D X‐ray imaging techniques, is one of the most versatile instruments in hard X‐ray microscopy science. This paper describes the present beamline characteristics, recent technical developments, as well as a few scientific examples from recent years of the beamline operation. The upgrade plans to adapt the beamline to the growing needs of the user community are briefly discussed. 相似文献
3.
B. Hornberger M. D. De Jonge M. Feser P. Holl C. Holzner C. Jacobsen D. Legnini D. Paterson P. Rehak L. Strüder S. Vogt 《Journal of synchrotron radiation》2008,15(4):355-362
Scanning X‐ray microprobes are unique tools for the nanoscale investigation of specimens from the life, environmental, materials and other fields of sciences. Typically they utilize absorption and fluorescence as contrast mechanisms. Phase contrast is a complementary technique that can provide strong contrast with reduced radiation dose for weakly absorbing structures in the multi‐keV range. In this paper the development of a segmented charge‐integrating silicon detector which provides simultaneous absorption and differential phase contrast is reported. The detector can be used together with a fluorescence detector for the simultaneous acquisition of transmission and fluorescence data. It can be used over a wide range of photon energies, photon rates and exposure times at third‐generation synchrotron radiation sources, and is currently operating at two beamlines at the Advanced Photon Source. Images obtained at around 2 keV and 10 keV demonstrate the superiority of phase contrast over absorption for specimens composed of light elements. 相似文献
4.
Yan Xi Binquan Kou Haohua Sun Juncheng Qi Jianqi Sun Jürgen Mohr Martin Börner Jun Zhao Lisa X. Xu Tiqiao Xiao Yujie Wang 《Journal of synchrotron radiation》2012,19(5):821-826
An X‐ray grating interferometer was installed at the BL13W beamline of Shanghai Synchrotron Radiation Facility (SSRF) for biomedical imaging applications. Compared with imaging results from conventional absorption‐based micro‐computed tomography, this set‐up has shown much better soft tissue imaging capability. In particular, using the set‐up, the carotid artery and the carotid vein in a formalin‐fixed mouse can be visualized in situ without contrast agents, paving the way for future applications in cancer angiography studies. The overall results have demonstrated the broad prospects of the existing set‐up for biomedical imaging applications at SSRF. 相似文献
5.
Young Pyo Hong Sophie‐Charlotte Gleber Thomas V. O'Halloran Emily L. Que Reiner Bleher Stefan Vogt Teresa K. Woodruff Chris Jacobsen 《Journal of synchrotron radiation》2014,21(1):229-234
X‐ray fluorescence nanotomography provides unprecedented sensitivity for studies of trace metal distributions in whole biological cells. Dose fractionation, in which one acquires very low dose individual projections and then obtains high statistics reconstructions as signal from a voxel is brought together (Hegerl & Hoppe, 1976), requires accurate alignment of these individual projections so as to correct for rotation stage runout. It is shown here that differential phase contrast at 10.2 keV beam energy offers the potential for accurate cross‐correlation alignment of successive projections, by demonstrating that successive low dose, 3 ms per pixel, images acquired at the same specimen position and rotation angle have a narrower and smoother cross‐correlation function (1.5 pixels FWHM at 300 nm pixel size) than that obtained from zinc fluorescence images (25 pixels FWHM). The differential phase contrast alignment resolution is thus well below the 700 nm × 500 nm beam spot size used in this demonstration, so that dose fractionation should be possible for reduced‐dose, more rapidly acquired, fluorescence nanotomography experiments. 相似文献
6.
Simone Schleede Martin Bech Klaus Achterhold Guillaume Potdevin Martin Gifford Rod Loewen Cecile Limborg Ronald Ruth Franz Pfeiffer 《Journal of synchrotron radiation》2012,19(4):525-529
The Compact Light Source is a miniature synchrotron producing X‐rays at the interaction point of a counter‐propagating laser pulse and electron bunch through the process of inverse Compton scattering. The small transverse size of the luminous region yields a highly coherent beam with an angular divergence of a few milliradians. The intrinsic monochromaticity and coherence of the produced X‐rays can be exploited in high‐sensitivity differential phase‐contrast imaging with a grating‐based interferometer. Here, the first multimodal X‐ray imaging experiments at the Compact Light Source at a clinically compatible X‐ray energy of 21 keV are reported. Dose‐compatible measurements of a mammography phantom clearly demonstrate an increase in contrast attainable through differential phase and dark‐field imaging over conventional attenuation‐based projections. 相似文献
7.
M. K. Tiwari P. Gupta A. K. Sinha S. R. Kane A. K. Singh S. R. Garg C. K. Garg G. S. Lodha S. K. Deb 《Journal of synchrotron radiation》2013,20(2):386-389
A microfocus X‐ray fluorescence spectroscopy beamline (BL‐16) at the Indian synchrotron radiation facility Indus‐2 has been constructed with an experimental emphasis on environmental, archaeological, biomedical and material science applications involving heavy metal speciation and their localization. The beamline offers a combination of different analytical probes, e.g. X‐ray fluorescence mapping, X‐ray microspectroscopy and total‐external‐reflection fluorescence characterization. The beamline is installed on a bending‐magnet source with a working X‐ray energy range of 4–20 keV, enabling it to excite K‐edges of all elements from S to Nb and L‐edges from Ag to U. The optics of the beamline comprises of a double‐crystal monochromator with Si(111) symmetric and asymmetric crystals and a pair of Kirkpatrick–Baez focusing mirrors. This paper describes the performance of the beamline and its capabilities with examples of measured results. 相似文献
8.
G. Mitrea J. Thieme P. Guttmann S. Heim S. Gleber 《Journal of synchrotron radiation》2008,15(1):26-35
Using the scanning transmission X‐ray microscope at BESSY II, colloidal structures from a Chernozem soil have been studied with a spatial resolution around 60 nm and a spectral resolution of 1700 at the K‐absorption edge of carbon. Elemental mapping has been used to determine the distribution of organic matter within the colloidal structures. Spectra have been extracted from image stacks to obtain information about the chemical state. For the analysis of the latter, principal component analysis and cluster analysis have been applied. It was possible, for example, to discriminate clay particles against organic components. 相似文献
9.
A. Rack T. Weitkamp M. Riotte D. Grigoriev T. Rack L. Helfen T. Baumbach R. Dietsch T. Holz M. Kr?mer F. Siewert M. Meduňa P. Cloetens E. Ziegler 《Journal of synchrotron radiation》2010,17(4):496-510
A systematic study is presented in which multilayers of different composition (W/Si, Mo/Si, Pd/B4C), periodicity (from 2.5 to 5.5 nm) and number of layers have been characterized. In particular, the intrinsic quality (roughness and reflectivity) as well as the performance (homogeneity and coherence of the outgoing beam) as a monochromator for synchrotron radiation hard X‐ray micro‐imaging are investigated. The results indicate that the material composition is the dominating factor for the performance. By helping scientists and engineers specify the design parameters of multilayer monochromators, these results can contribute to a better exploitation of the advantages of multilayer monochromators over crystal‐based devices; i.e. larger spectral bandwidth and high photon flux density, which are particularly useful for synchrotron‐based micro‐radiography and ‐tomography. 相似文献
10.
Current status of the TwinMic beamline at Elettra: a soft X‐ray transmission and emission microscopy station 下载免费PDF全文
Alessandra Gianoncelli George Kourousias Lucia Merolle Matteo Altissimo Anna Bianco 《Journal of synchrotron radiation》2016,23(6):1526-1537
The current status of the TwinMic beamline at Elettra synchrotron light source, that hosts the European twin X‐ray microscopy station, is reported. The X‐ray source, provided by a short hybrid undulator with source size and divergence intermediate between bending magnets and conventional undulators, is energy‐tailored using a collimated plane‐grating monochromator. The TwinMic spectromicroscopy experimental station combines scanning and full‐field imaging in a single instrument, with contrast modes such as absorption, differential phase, interference and darkfield. The implementation of coherent diffractive imaging modalities and ptychography is ongoing. Typically, scanning transmission X‐ray microscopy images are simultaneously collected in transmission and differential phase contrast and can be complemented by chemical and elemental analysis using across‐absorption‐edge imaging, X‐ray absorption near‐edge structure or low‐energy X‐ray fluorescence. The lateral resolutions depend on the particular imaging and contrast mode chosen. The TwinMic range of applications covers diverse research fields such as biology, biochemistry, medicine, pharmacology, environment, geochemistry, food, agriculture and materials science. They will be illustrated in the paper with representative results. 相似文献
11.
Andrew W. Stevenson Sheridan C. Mayo Daniel H?usermann Anton Maksimenko Richard F. Garrett Christopher J. Hall Stephen W. Wilkins Robert A. Lewis Damian E. Myers 《Journal of synchrotron radiation》2010,17(1):75-80
The Imaging and Medical beamline at the Australian Synchrotron achieved `first light' in December 2008. Here, the first experiments performed on the beamline are reported, which involved both X‐ray imaging and tomography studies for a range of samples. The use of a plastic‐edge phantom for quantitative measurements of contrast and resolution proved to be very instructive and helped to confirm certain parameter values such as the effective horizontal source size, detector resolution and average X‐ray energy for the polychromatic beam. 相似文献
12.
J. Segura‐Ruiz G. Martinez‐Criado J. A. Sans R. Tucoulou P. Cloetens I. Snigireva C. Denker J. Malindretos A. Rizzi M. Gomez‐Gomez N. Garro A. Cantarero 《固体物理学:研究快报》2011,5(3):95-97
Using synchrotron radiation nanoprobe, this work reports on the elemental distribution in single Inx Ga1–xN nanowires (NWs) grown by molecular beam epitaxy directly on Si(111) substrates. Single NWs dispersed on Al covered sapphire were characterized by nano‐X‐ray fluorescence, Raman scattering and photoluminescence spectroscopy. Both Ga and In maps reveal an inhomogeneous axial distribution inside sin‐ gle NWs. The analysis of NWs from the same sample but with different dimensions suggests a decrease of In segregation with the reduction of NW diameter, while Ga distribution seems to remain unaltered. Photoluminescence and Raman scattering measurements carried out on ensembles of NWs exhibit relevant signatures of the compositional disorder. (© 2011 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim) 相似文献
13.
Chunlei Li Andrew M. Kiss Douglas G. Van Campen Alex Garachtchenko Yuriy Kolotovsky Kevin Stone Yahong Xu Wenjun Zhang Jeff Corbett 《Journal of synchrotron radiation》2016,23(4):909-918
Typical X‐ray diffraction measurements are made by moving a detector to discrete positions in space and then measuring the signal at each stationary position. This step‐scanning method can be time‐consuming, and may induce vibrations in the measurement system when the motors are accelerated and decelerated at each position. Furthermore, diffraction information between the data points may be missed unless a fine step‐scanning is used, which further increases the total measurement time. To utilize beam time efficiently, the motor acceleration and deceleration time should be minimized, and the signal‐to‐noise ratio should be maximized. To accomplish this, an integrated continuous‐scan system was developed at the Stanford Synchrotron Radiation Lightsource (SSRL). The continuous‐scan system uses an in‐house integrated motor controller system and counter/timer electronics. SPEC software is used to control both the hardware and data acquisition systems. The time efficiency and repeatability of the continuous‐scan system were tested using X‐ray diffraction from a ZnO powder and compared with the step‐scan technique. Advantages and limitations of the continuous‐scan system and a demonstration of variable‐velocity continuous scan are discussed. 相似文献
14.
R. A. Barrea D. Gore N. Kujala C. Karanfil S. Kozyrenko R. Heurich M. Vukonich R. Huang T. Paunesku G. Woloschak T. C. Irving 《Journal of synchrotron radiation》2010,17(4):522-529
There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X‐ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast‐scanning high‐flux X‐ray microprobe, built around a recently commissioned pair of 200 mm‐long Rh‐coated silicon Kirkpatrick–Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 × 1012 photons s?1 into a minimum focal spot size of ~3–5 µm FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X‐ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on‐the‐fly with minimal overhead time (<20 ms per pixel). Together, the high‐flux X‐ray microbeam and the rapid‐scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X‐ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples. 相似文献
15.
Hard X‐ray phase‐contrast tomography of non‐homogeneous specimens: grating interferometry versus propagation‐based imaging 下载免费PDF全文
Maite Ruiz-Yaniz Irene Zanette Adrian Sarapata Lorenz Birnbacher Mathias Marschner Michael Chabior Margie Olbinado Franz Pfeiffer Alexander Rack 《Journal of synchrotron radiation》2016,23(5):1202-1209
X‐ray phase‐contrast imaging is an effective approach to drastically increase the contrast and sensitivity of microtomographic techniques. Numerous approaches to depict the real part of the complex‐valued refractive index of a specimen are nowadays available. A comparative study using experimental data from grating‐based interferometry and propagation‐based phase contrast combined with single‐distance phase retrieval applied to a non‐homogeneous sample is presented (acquired at beamline ID19‐ESRF). It is shown that grating‐based interferometry can handle density gradients in a superior manner. The study underlines the complementarity of the two techniques for practical applications. 相似文献
16.
Keiichi Hirano Yumiko Takahashi Kazuyuki Hyodo Masao Kimura 《Journal of synchrotron radiation》2016,23(6):1484-1489
X‐ray analyzer‐based phase‐contrast imaging is combined with computed laminography for imaging regions of interest in laterally extended flat specimens of weak absorption contrast. The optics discussed here consist of an asymmetrically cut collimator crystal and a symmetrically cut analyzer crystal arranged in a nondispersive (+, ?) diffraction geometry. A generalized algorithm is given for calculating multi‐contrast (absorption, refraction and phase contrast) images of a sample. Basic formulae are also presented for laminographic reconstruction. The feasibility of the method discussed was verified at the vertical wiggler beamline BL‐14B of the Photon Factory. At a wavelength of 0.0733 nm, phase‐contrast sectional images of plastic beads were successfully obtained. Owing to strong circular artifacts caused by a sample holder, the field of view was limited to about 6 mm in diameter. 相似文献
17.
D. Lützenkirchen‐Hecht R. Wagner S. Szillat A. K. Hüsecken K. Istomin U. Pietsch Ronald Frahm 《Journal of synchrotron radiation》2014,21(4):819-826
The layout and the characteristics of the hard X‐ray beamline BL10 at the superconducting asymmetric wiggler at the 1.5 GeV Dortmund Electron Accelerator DELTA are described. This beamline is equipped with a Si(111) channel‐cut monochromator and is dedicated to X‐ray studies in the spectral range from ~4 keV to ~16 keV photon energy. There are two different endstations available. While X‐ray absorption studies in different detection modes (transmission, fluorescence, reflectivity) can be performed on a designated table, a six‐axis kappa diffractometer is installed for X‐ray scattering and reflectivity experiments. Different detector set‐ups are integrated into the beamline control software, i.e. gas‐filled ionization chambers, different photodiodes, as well as a Pilatus 2D‐detector are permanently available. The performance of the beamline is illustrated by high‐quality X‐ray absorption spectra from several reference compounds. First applications include temperature‐dependent EXAFS experiments from liquid‐nitrogen temperature in a bath cryostat up to ~660 K by using a dedicated furnace. Besides transmission measurements, fluorescence detection for dilute sample systems as well as surface‐sensitive reflection‐mode experiments are presented. 相似文献
18.
The contrast mechanism for imaging molecular‐scale features on solid surfaces is described for X‐ray reflection interface microscopy (XRIM) through comparison of experimental images with model calculations and simulated measurements. Images of elementary steps show that image contrast is controlled by changes in the incident angle of the X‐ray beam with respect to the sample surface. Systematic changes in the magnitude and sign of image contrast are asymmetric for angular deviations of the sample from the specular reflection condition. No changes in image contrast are observed when defocusing the condenser or objective lenses. These data are explained with model structure‐factor calculations that reproduce all of the qualitative features observed in the experimental data. These results provide new insights into the image contrast mechanism, including contrast reversal as a function of incident angle, the sensitivity of image contrast to step direction (i.e. up versus down), and the ability to maximize image contrast at almost any scattering condition defined by the vertical momentum transfer, Qz. The full surface topography can then, in principle, be recovered by a series of images as a function of incident angle at fixed momentum transfer. Inclusion of relevant experimental details shows that the image contrast magnitude is controlled by the intersection of the reciprocal‐space resolution function (i.e. controlled by numerical aperture of the condenser and objective lenses) and the spatially resolved interfacial structure factor of the object being imaged. Together these factors reduce the nominal contrast for a step near the specular reflection condition to a value similar to that observed experimentally. This formalism demonstrates that the XRIM images derive from limited aperture contrast, and explains how non‐zero image contrast can be obtained when imaging a pure phase object corresponding to the interfacial topography. 相似文献
19.
Heng Chen Zhili Wang Kun Gao Qiyue Hou Dajiang Wang Ziyu Wu 《Journal of synchrotron radiation》2015,22(4):1056-1061
In recent years, increasing attention has been devoted to X‐ray phase contrast imaging, since it can provide high‐contrast images by using phase variations. Among the different existing techniques, Zernike phase contrast microscopy is one of the most popular phase‐sensitive techniques for investigating the fine structure of the sample at high spatial resolution. In X‐ray Zernike phase contrast microscopy, the image contrast is indeed a mixture of absorption and phase contrast. Therefore, this technique just provides qualitative information on the object, which makes the interpretation of the image difficult. In this contribution, an approach is proposed for quantitative phase retrieval in X‐ray Zernike phase contrast microscopy. By shifting the phase of the direct light by π/2 and 3π/2, two images of the same object are measured successively. The phase information of the object can then be quantitatively retrieved by a proper combination of the measured images. Numerical experiments were carried out and the results confirmed the feasibility of the proposed method. It is expected that the proposed method will find widespread applications in biology, materials science and so on. 相似文献
20.
Martin Bech Oliver Bunk Christian David Ronald Ruth Jeff Rifkin Rod Loewen Robert Feidenhans'l Franz Pfeiffer 《Journal of synchrotron radiation》2009,16(1):43-47
The first imaging results obtained from a small‐size synchrotron are reported. The newly developed Compact Light Source produces inverse Compton X‐rays at the intersection point of the counter propagating laser and electron beam. The small size of the intersection point gives a highly coherent cone beam with a few milliradian angular divergence and a few percent energy spread. These specifications make the Compact Light Source ideal for a recently developed grating‐based differential phase‐contrast imaging method. 相似文献