首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Third‐generation synchrotron radiation sources pose difficult challenges for energy‐dispersive detectors for XAFS because of their count rate limitations. One solution to this problem is the bent crystal Laue analyzer (BCLA), which removes most of the undesired scatter and fluorescence before it reaches the detector, effectively eliminating detector saturation due to background. In this paper experimental measurements of BCLA performance in conjunction with a 13‐element germanium detector, and a quantitative analysis of the signal‐to‐noise improvement of BCLAs are presented. The performance of BCLAs are compared with filters and slits.  相似文献   

2.
An end‐station for X‐ray Raman scattering spectroscopy at beamline ID20 of the European Synchrotron Radiation Facility is described. This end‐station is dedicated to the study of shallow core electronic excitations using non‐resonant inelastic X‐ray scattering. The spectrometer has 72 spherically bent analyzer crystals arranged in six modular groups of 12 analyzer crystals each for a combined maximum flexibility and large solid angle of detection. Each of the six analyzer modules houses one pixelated area detector allowing for X‐ray Raman scattering based imaging and efficient separation of the desired signal from the sample and spurious scattering from the often used complicated sample environments. This new end‐station provides an unprecedented instrument for X‐ray Raman scattering, which is a spectroscopic tool of great interest for the study of low‐energy X‐ray absorption spectra in materials under in situ conditions, such as in operando batteries and fuel cells, in situ catalytic reactions, and extreme pressure and temperature conditions.  相似文献   

3.
A bent‐crystal spectrometer based on the Rowland circle geometry has been installed and tested on the BM30b/FAME beamline at the European Synchrotron Radiation Facility to improve its performances. The energy resolution of the spectrometer allows different kinds of measurements to be performed, including X‐ray absorption spectroscopy, resonant inelastic X‐ray scattering and X‐ray Raman scattering experiments. The simplicity of the experimental device makes it easily implemented on a classical X‐ray absorption beamline. This improvement in the fluorescence detection is of particular importance when the probed element is embedded in a complex and/or heavy matrix, for example in environmental sciences.  相似文献   

4.
The design and commissioning of an inelastic X‐ray scattering instrument at CMC‐XOR at the Advanced Photon Source is reported. The instrument features a 2 m vertical‐scattering arm with a novel counterweight design to reduce the twisting moment as the arm is moved in the scattering plane. A Ge(733) spherical analyzer was fabricated and an overall resolution of 118 meV (FWHM) was obtained with a Si(444) monochromator and a Si(111) pre‐monochromator. Early results from a representative cuprate, La2CuO4, are reported.  相似文献   

5.
The development of medium‐energy inelastic X‐ray scattering optics with meV and sub‐meV resolution has attracted considerable efforts in recent years. Meanwhile, there are also concerns or debates about the fundamental and feasibility of the involved schemes. Here the central optical component, the back‐reflection angular‐dispersion monochromator or analyzer, is analyzed. The results show that the multiple‐beam diffraction effect together with transmission‐induced absorption can noticeably reduce the diffraction efficiency, although it may not be a fatal threat. In order to improve the efficiency, a simple four‐bounce analyzer is proposed that completely avoids these two adverse effects. The new scheme is illustrated to be a feasible alternative approach for developing meV‐ to sub‐meV‐resolution inelastic X‐ray scattering spectroscopy.  相似文献   

6.
A multiple‐analyser‐crystal spectrometer for non‐resonant inelastic X‐ray scattering spectroscopy installed at beamline ID16 of the European Synchrotron Radiation Facility is presented. Nine analyser crystals with bending radii R = 1 m measure spectra for five different momentum transfer values simultaneously. Using a two‐dimensional detector, the spectra given by all analysers can be treated individually. The spectrometer is based on a Rowland circle design with fixed Bragg angles of about 88°. The energy resolution can be chosen between 30–2000 meV with typical incident‐photon energies of 6–13 keV. The spectrometer is optimized for studies of valence and core electron excitations resolving both energy and momentum transfer.  相似文献   

7.
X‐ray Raman scattering (XRS) provides a bulk‐sensitive method of measuring the extended X‐ray absorption fine structure (EXAFS) of soft X‐ray absorption edges. Accurate measurements and data analysis procedures for the determination of XRS‐EXAFS of polycrystalline diamond are described. The contributions of various angular‐momentum components beyond the dipole limit to the atomic background and the EXAFS oscillations are incorporated using self‐consistent real‐space multiple‐scattering calculations. The properly extracted XRS‐EXAFS oscillations are in good agreement with calculations and earlier soft X‐ray EXAFS results. It is shown, however, that under certain conditions multiple‐scattering contributions to XRS‐EXAFS deviate from those in standard EXAFS, leading to noticeable changes in the real‐space signal at higher momentum transfers owing to non‐dipole contributions. These results pave the way for the accurate application of XRS‐EXAFS to previously inaccessible light‐element systems.  相似文献   

8.
The X‐ray optics group at the Swiss Light Source in co‐operation with RIT (Rigaku Innovative Technologies) have investigated seven different multilayer samples. The goal was to find an ideal multilayer structure for the energy range between 6 keV and 20 keV in terms of energy resolution and reflectivity. Such multilayer structures deposited on substrates can be used as X‐ray monochromators or reflecting synchrotron mirrors. The measured reflectivities agree with the simulated ones. They cover a reflectivity range from 45% to 80% for energies between 6 keV and 10 keV, and 80% to 90% for energies between 10 keV and 20 keV. The experimentally measured energy resolution of the samples lies between 0.3% and 3.5%.  相似文献   

9.
Inelastic X‐ray scattering instruments in operation at third‐generation synchrotron radiation facilities are based on backreflections from perfect silicon crystals. This concept reaches back to the very beginnings of high‐energy‐resolution X‐ray spectroscopy and has several advantages but also some inherent drawbacks. In this paper an alternate path is investigated using a different concept, the `M4 instrument'. It consists of a combination of two in‐line high‐resolution monochromators, focusing mirrors and collimating mirrors. Design choices and performance estimates in comparison with existing conventional inelastic X‐ray scattering instruments are presented.  相似文献   

10.
An end‐station for resonant inelastic X‐ray scattering and (resonant) X‐ray emission spectroscopy at beamline ID20 of ESRF – The European Synchrotron is presented. The spectrometer hosts five crystal analysers in Rowland geometry for large solid angle collection and is mounted on a rotatable arm for scattering in both the horizontal and vertical planes. The spectrometer is optimized for high‐energy‐resolution applications, including partial fluorescence yield or high‐energy‐resolution fluorescence detected X‐ray absorption spectroscopy and the study of elementary electronic excitations in solids. In addition, it can be used for non‐resonant inelastic X‐ray scattering measurements of valence electron excitations.  相似文献   

11.
The design, construction and commissioning of a beamline and spectrometer for inelastic soft X‐ray scattering at high resolution in a highly efficient system are presented. Based on the energy‐compensation principle of grating dispersion, the design of the monochromator–spectrometer system greatly enhances the efficiency of measurement of inelastic soft X‐rays scattering. Comprising two bendable gratings, the set‐up effectively diminishes the defocus and coma aberrations. At commissioning, this system showed results of spin‐flip, dd and charge‐transfer excitations of NiO. These results are consistent with published results but exhibit improved spectral resolution and increased efficiency of measurement. The best energy resolution of the set‐up in terms of full width at half‐maximum is 108 meV at an incident photon energy tuned about the Ni L3‐edge.  相似文献   

12.
A spectrometer for resonant inelastic X‐ray scattering (RIXS) is proposed where imaging and dispersion actions in two orthogonal planes are combined to deliver a full two‐dimensional map of RIXS intensity in one shot with parallel detection at incoming hvin and outgoing hvout photon energies. Preliminary ray‐tracing simulations with a typical undulator beamline demonstrate a resolving power well above 11000 with both hvin and hvout near 930 eV, with a vast potential for improvement. Combining this instrument – nicknamed hv2 spectrometer – with an X‐ray free‐electron laser source simplifies its technical implementation and enables efficient time‐resolved RIXS experiments.  相似文献   

13.
Transmission X‐ray mirrors have been fabricated from 300–400 nm‐thick low‐stress silicon nitride windows of size 0.6 mm × 85 mm. The windows act as a high‐pass energy filter at grazing incidence in an X‐ray beam for the beam transmitted through the window. The energy cut‐off can be selected by adjusting the incidence angle of the transmission mirror, because the energy cut‐off is a function of the angle of the window with respect to the beam. With the transmission mirror at the target angle of 0.22°, a 0.3 mm × 0.3 mm X‐ray beam was allowed to pass through the mirror with a cut‐off energy of 10 keV at the Cornell High Energy Synchrotron Source. The energy cut‐off can be adjusted from 8 to 12 keV at an angle of 0.26° to 0.18°, respectively. The observed mirror transmittance was above 80% for a 300 nm‐thick film.  相似文献   

14.
The crystal and local atomic structure of monoclinic ReO2 (α‐ReO2) under hydrostatic pressure up to 1.2 GPa was investigated for the first time using both X‐ray absorption spectroscopy and high‐resolution synchrotron X‐ray powder diffraction and a home‐built B4C anvil pressure cell developed for this purpose. Extended X‐ray absorption fine‐structure (EXAFS) data analysis at pressures from ambient up to 1.2 GPa indicates that there are two distinct Re—Re distances and a distorted ReO6 octahedron in the α‐ReO2 structure. X‐ray diffraction analysis at ambient pressure revealed an unambiguous solution for the crystal structure of the α‐phase, demonstrating a modulation of the Re—Re distances. The relatively small portion of the diffraction pattern accessed in the pressure‐dependent measurements does not allow for a detailed study of the crystal structure of α‐ReO2 under pressure. Nonetheless, a shift and reduction in the (011) Bragg peak intensity between 0.4 and 1.2 GPa is observed, with correlation to a decrease in Re—Re distance modulation, as confirmed by EXAFS analysis in the same pressure range. This behavior reveals that α‐ReO2 is a possible inner pressure gauge for future experiments up to 1.2 GPa.  相似文献   

15.
16.
Non‐resonant inelastic X‐ray scattering of core electrons is a prominent tool for studying site‐selective, i.e. momentum‐transfer‐dependent, shallow absorption edges of liquids and samples under extreme conditions. A bottleneck of the analysis of such spectra is the appropriate subtraction of the underlying background owing to valence and core electron excitations. This background exhibits a strong momentum‐transfer dependence ranging from plasmon and particle–hole pair excitations to Compton scattering of core and valence electrons. In this work an algorithm to extract the absorption edges of interest from the superimposed background for a wide range of momentum transfers is presented and discussed for two examples, silicon and the compound silicondioxide.  相似文献   

17.
An algorithm to simultaneously increase the spatial and statistical accuracy of X‐ray Raman scattering (XRS) based tomographic images is presented. Tomography that utilizes XRS spectroscopy signals as a contrast for the images is a new and promising tool for investigating local atomic structure and chemistry in heterogeneous samples. The algorithm enables the spatial resolution to be increased based on a deconvolution of the optical response function of the spectrometer and, most importantly, it allows for the combination of data collected from multiple analyzers and thus enhances the statistical accuracy of the measured images.  相似文献   

18.
X‐ray absorption and scattering spectroscopies involving the 3d transition‐metal K‐ and L‐edges have a long history in studying inorganic and bioinorganic molecules. However, there have been very few studies using the M‐edges, which are below 100 eV. Synchrotron‐based X‐ray sources can have higher energy resolution at M‐edges. M‐edge X‐ray absorption spectroscopy (XAS) and resonant inelastic X‐ray scattering (RIXS) could therefore provide complementary information to K‐ and L‐edge spectroscopies. In this study, M2,3‐edge XAS on several Co, Ni and Cu complexes are measured and their spectral information, such as chemical shifts and covalency effects, are analyzed and discussed. In addition, M2,3‐edge RIXS on NiO, NiF2 and two other covalent complexes have been performed and different dd transition patterns have been observed. Although still preliminary, this work on 3d metal complexes demonstrates the potential to use M‐edge XAS and RIXS on more complicated 3d metal complexes in the future. The potential for using high‐sensitivity and high‐resolution superconducting tunnel junction X‐ray detectors below 100 eV is also illustrated and discussed.  相似文献   

19.
A quantitative analysis of the crucial characteristics of currently used and promising materials for X‐ray refractive optics is performed in the extended energy range 8–100 keV. According to the examined parameters, beryllium is the material of choice for X‐ray compound refractive lenses (CRLs) in the energy range 8–25 keV. At higher energies the use of CRLs made of diamond and the cubic phase of boron nitride (c‐BN) is beneficial. It was demonstrated that the presence of the elements of the fourth (or higher) period has a fatal effect on the functional X‐ray properties even if low‐Z elements dominate in the compound, like in YB66. Macroscopic properties are discussed: much higher melting points and thermal conductivities of C and c‐BN enable them to be used at the new generation of synchrotron radiation sources and X‐ray free‐electron lasers. The role of crystal and internal structure is discussed: materials with high density are preferable for refractive applications while less dense phases are suitable for X‐ray windows. Single‐crystal or amorphous glass‐like materials based on Li, Be, B or C that are free of diffuse scattering from grain boundaries, voids and inclusions are the best candidates for applications of highly coherent X‐ray beams.  相似文献   

20.
Advances in resonant inelastic X‐ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the Ir L3‐edge stands at ~25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid‐angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the Ir L3‐absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X‐ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27‐ID at the Advanced Photon Source. X‐rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X‐ray measurements, ray‐tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high‐resolution RIXS multi‐crystal analyzer system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号