首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the routine determination of 5'-mononucleotides (uridine 5'-monophosphate, inosine 5'-monophosphate, adenosine 5'-monophosphate, guanosine 5'-monophosphate, and cytidine 5'-monophosphate) in infant formula and adult nutritionals is described. After sample dissolution and addition of internal standard, potential interferences were removed by anion-exchange SPE followed by HPLC-UV analysis. Single-laboratory validation performance parameters include recovery (92-101%) and repeatability (1.0-2.3% RSD). The method was approved for Official First Action status by an AOAC expert review panel.  相似文献   

2.
Ultra-performance liquid chromatography (UPLC)/MS/MS was applied to measure vitamin D in various foods and nutritional supplements. The run-time of the chromatographic separation was cut from 20 min in HPLC/MS/MS to 10 min in UPLC/MS/MS, while equal or better separation efficiency was achieved to deal with complex food matrixes. Under the optimized conditions, all the previtamins of vitamin D3, D2, and isotope-labeled vitamin D3 were baseline-separated from their corresponding vitamins. It was also demonstrated that many sterol isomers in complex food matrixes that interfere in the analysis could be well-separated from the analytes. Accuracy of this method was evaluated by analysis of NIST SRM 1849 infant formula reference material. With eight replicates, the average vitamin D3 concentration was 0.251 +/- 0.012 mg/kg, an excellent agreement with the certified value of 0.251 +/- 0.027 mg/kg. In addition, spike recovery from a commercial infant formula matrix was in the range of 100 to 108% for both vitamins D3 and D2 at three spike concentration levels. The spike recovery for an even more complex matrix, pet food, was 101-105%. LOQ values were 0.026 and 0.033 IU/g, or 0.086 and 0.11 IU/mL in solution, for vitamins D3 and D2, respectively. The dynamic range had three orders of magnitude, which made the method flexible and useful to deal with the wide concentration range of vitamin D in various samples. The method was robust based on the results of changing the parameters of LC separation and MS measurement. This accurate and reliable vitamin D method increased instrument efficiency and analysis productivity significantly.  相似文献   

3.
The method for the "Determination of Vitamins D2 and D3 in Infant Formula and Adult Nutritionals by Ultra-Pressure Liquid Chromatography with Tandem Mass Spectrometry Detection (UPLC-MS/MS)" was adopted as AOAC Official First Action during the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting" held June 29, 2011. During the meeting, an Expert Review Panel (ERP) evaluated the available validation information against standard method performance requirements (SMPRs) articulated by stakeholders. The method, approved by the ERP, is applicable for the determination of vitamin D (total vitamins D2 and D3). A range of products had been tested during a single-laboratory validation study. The products included butter, National Institute of Standards and Technology SRM 1849, eggs, cheese, yogurt, ready-to-eat cereal, bread, mushrooms, and tuna. The testing of the method established linearity in the range of 0.005-50 microg/mL. The recovery range was 93.4-100.9% for vitamin D2 and 102.4-106.2% for vitamin D3. The LOD and LOQ for vitamin D2 were reported as 0.20 and 0.61 microgl100 g, respectively; for vitamin D3, the reported values were 0.47 and 1.44 microg/100 g, respectively. The method met the SMPRs set by the Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN). It was, therefore, decided that the method was appropriate for Official First Action Method status.  相似文献   

4.
An inductively coupled plasma/MS method was developed for the simultaneous determination of Cr, Se, and Mo in infant formula and other nutritional products. All samples were digested using a closed vessel microwave oven system, together with Ni and Te internal standards. The practical quantitation limits for Cr, Se, and Mo were 0.4, 0.2, and 0.4 ng/mL, respectively; dilution factors were 250 for powders and 50 for liquids. The Cr, Se, and Mo concentrations in 10 nutritional products were within specification limits; within-day and day-to-day (6 independent days) precision values were <5% RSD. For two control samples, the observed precision was < or = 2% RSD over 10 independent days. Cr, Se, and Mo results were within the certified limits in three National Institute of Standards and Technology standard reference materials. The average sample spike recoveries for 10 nutritional products ranged from 93 to 107%. Robustness studies showed a minimal effect from concomitant easily ionized element concentrations. However, the choice of internal standard and matrix-matching carbon content were critical to obtaining accurate Se results. All indications are that this method would be a suitable candidate as a global reference method for the determination of these trace elements in infant formula, adult nutritionals, and other nutritional  相似文献   

5.
建立了婴幼儿配方奶粉中维生素D的液相色谱-大气压化学电离串联质谱(LC-APCI-MS/MS)分析方法。样品经正己烷和甲基叔丁基醚混合溶液提取,ProElut VDC固相萃取柱净化,Kinetex C_(18)色谱柱分离,采用大气压化学电离(APCI)源、正离子扫描和多反应监测(MRM)模式对维生素D_2和维生素D_3进行检测,内标法定量。结果表明维生素D_2和维生素D_3在5~5 000μg/L范围内均具有良好的线性关系,检出限为2μg/kg,定量限为5μg/kg。在5、10和100μg/kg添加水平下,维生素D_2和维生素D_3的回收率为85.2%~105.3%,相对标准偏差为4.7%~8.1%。该方法简便准确,灵敏度高,适用于婴幼儿奶粉中维生素D的测定。  相似文献   

6.
7.
After a review of data from a single-laboratory validation (SLV) study published in the International Dairy Journal 21, 783-789 (2011), a method for folate in infant formula and adult/pediatric nutritional formula was submitted for consideration of adoption by AOAC as an automated assay that is rapid and simple. The method uses an optical biosensor assay to quantitate total folate content in milk and milk-based pediatric and adult nutritional products. The assay uses folate binding protein and a functionalized sensor surface. The SLV showed an instrumental LOD of 0.1 ng/mL (equivalent to 2.5 microg/100 g for a typical infant formula). The method detection limit was 6.5 microg/100 g with a repeatability of 3.48% and an intermediate reproducibility of 4.63% RSD.  相似文献   

8.
A liquid chromatographic/tandem mass spectrometric method using pneumatically assisted electrospray ionization (LC-ESI-MS/MS) was developed for determination of N-acetylneuramic acid and N-glycolylneuramic acid in infant formula. Reconstituted samples were hydrolysed in dilute sulfuric acid and deproteinized with acetonitrile. The extract was analysed directly without further clean-up by hydrophilic interaction chromatography. The substances were detected in negative ion mode and matrix matched standards were used for calibration. The relative intra-laboratory reproducibility standard deviation was better than 6% for both substances. An R2 of 0.985 was obtained by comparison with a classical colorimetric assay based on reaction with resorcinol. The developed method is expected to be applied for accurate routine analysis of infant formulas.  相似文献   

9.
During the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting," held on June 29, 2011, an Expert Review Panel (ERP) reviewed the method for the "Determination of Vitamins A (Retinol) and E (alpha-Tocopherol) in Foods by Liquid Chromatography: Collaborative Study," published by Jonathan W. DeVries and Karlene R. Silvera in J. AOAC Int. in 2002. After evaluation of the original validation data, an ERP agreed in June 2011 that the method meets standard method performance requirements (SMPRs) for vitamin A, as articulated by the Stakeholder Panel on Infant Formula and Adult Nutritionals. The ERP granted the method First Action status, applicable to determining vitamin A in ready-to-eat infant and adult nutritional formula. In an effort to achieve Final Action status, it was recommended that additional information be generated for different types of infant and adult nutritional formula matrixes at varied concentration levels as indicated in the vitamin A (retinol) SMPR. Existing AOAC LC methods are suited for specific vitamin A analytical applications. The original method differs from existing methods in that it can be used to assay samples in all nine sectors of the food matrix. One sector of the food matrix was powdered infant formula and gave support for the First Action approval for vitamin A in infant and adult nutritional formula. In this method, standards and test samples are saponified in basic ethanol-water solution, neutralized, and diluted, converting fats to fatty acids and retinol esters to retinol. Retinol is quantitated by an LC method, using UV detection at 313 or 328 nm for retinol. Vitamin concentration is calculated by comparison of the peak heights or peak areas of retinol in test samples with those of standards.  相似文献   

10.
Official Method 2011.21 is for the quantitation of the following nucleotides: adenosine 5'-monophosphate (AMP), guanosine 5'-monophosphate (GMP), uridine 5'-monophosphate (UMP), cytidine 5'-monophosphate (CMP), and inosine 5'-monophosphate (IMP) in infant formula and adult/pediatric nutritional formula. It uses hydrophilic interaction liquid chromatography with tandem mass spectrometry (HILIC-MS/MS). Preparation of the internal standards was conducted using centrifugal ultrafiltration and the standards are AMP- (13)C10, (15)N5; GMP-(13)C10, (15)N5; UMP-(13)C9, (15)N2; and15 CMP- (13)C9, (15)N3. Data were collected by using multiple reaction monitoring of the product ions of protonated molecules of the five nucleotides generated by positive-electrospray ionization. The HILIC conditions were conducted with ammonium formate (30 mmol/L) in water (pH 2.5, adjusted with formic acid) and methanol. The LOD and LOQ of the standard solution were 0.005-0.01 and 0.01-0.03 microg/mL, respectively. Recovery data were collected for intraday and interday testing and ranged from 98.1 to 108.9% with an RSD of 0.7-5.4%. The analytical range of the method is between 0.04 to 5 microg/mL for standard solution.  相似文献   

11.
A sensitive method was developed using ultra-high-performance liquid chromatography (UHPLC)/MS/MS with positive electrospray ionization for determining aflatoxin M1 (AFM1) in milk and milk powder. A 50 mL quantity of low-fat liquid milk containing 100 ng/L AFM1, was prepared using immunoaffinity columns with a mean recovery rate of 79% (n = 3). UHPLC columns (BEH C18, BEH HILIC, and HSS T3) greatly reduced the chromatographic time and lowered the instrumental detection limits (IDLs) 16 to 58 times compared to an HPLC column (Betabasic C18). The HSS T3 column was chosen because it provided a low IDL (0.11 pg) and the lowest ion suppression of signal intensity (63.4%) among the tested columns. Matrix-fortified calibration curves were used for quantification and showed good linearity (r > 0.997) at 0.05-500 ng/mL. The LOD was 0.18 ng/kg for milk and 2.08 nglkg for milk powder, based on the signal intensity of the confirmatory product ion (m/z 259.1), which was less abundant than the quantitative product ion (m/z 273.1). Certified reference materials of milk powder at three levels (<0.05, 0.111 +/- 0.018, and 0.44 +/- 0.06 microg/kg) were measured within a day and between days; the results were all close to the certified levels with low variations (RSDs < 15%), showing good precision and accuracy.  相似文献   

12.
At the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting," on June 29, 2011, an Expert Review Panel agreed that the method "Determination of Vitamin B12 in Infant Formulas and Adult Nutritionals by Liquid Chromatography/UV Detection with Immunoaffinity Extraction" be adopted AOAC Official First Action status. The method is applicable for the determination of vitamin B12, which includes added cyanocobalamin and natural forms, making it applicable to both fortified and nonfortified products. Vitamin B12 is extracted from the sample in sodium acetate buffer in the presence of sodium cyanide (100 degrees C, 30 min). After purification and concentration with an immunoaffinity column, vitamin B12 is determined by LC with UV detection (361 nm). A single-laboratory validation study was conducted on a range of products, including milk- and soy-based infant formulas, cereals, cocoa beverages, health care products, and polyvitamin premixes. The method demonstrated linear response over a large range of concentrations, recovery rates of 100.8 +/- 7.5% (average +/- SD), repeatability RSD (RSDr) of 2.1%, and intermediate reproducibility (RSD(iR)) of 4.3%. LOD and LOQ values were 0.10 and 0.30 microg/100 g, respectively, and correlation with the reference microbiological assay was good (R2 = 0.9442). The results of the study were published in J. AOAC Int. 91, 786-793 (2008). The performance characteristics of the method met the standard method performance requirements set forth by the Stakeholder Panel on Infant Formula and Adult Nutritionals; thus, the method was determined to be appropriate for First Action status.  相似文献   

13.
14.
A sensitive method using liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was developed and validated to quantify and confirm 13 pesticides, including aldicarb sulfoxide, aldicarb sulfone, oxamyl, methomyl, formetanate, 3-hydroxycarbofuran, carbendazim, thiabendazole, aldicarb, propoxur, carbofuran, carbaryl, and methiocarb, in soy-based infant formula. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring of 2 fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantitation and confirmation. Different approaches to constructing calibration curves were compared and discussed to address issues of the extraction efficiency or recovery, and matrix effects. Matrix-matched standard calibration curves with the use of isoprocarb as an internal standard were finally used to achieve the best accuracy of the method. Under most circumstances, recoveries of 13 pesticides, spiked at 5.0, 25.0, and 45.0 microg/kg, were close to 100%. The method detection limits (signal-to-noise ratio > or =3:1; microg/kg) of 13 pesticides were 0.2 for thiabendazole and methiocarb, 0.6 for aldicarb, and 0.1 for the others.  相似文献   

15.
16.
Vitamin A, a fat-soluble vitamin, is essential for health and plays an important part in vision, bone growth, reproduction, regulating the immune system, cell function, and skin health. Due to the advances in technology and the expansion of its uses, LC technologies are being studied for effectiveness in detecting and quantifying vitamin A in an effort to help determine the amount of vitamin A in various types of samples. For this reason, an Expert Review Panel agreed on June 29, 2011, at the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting," to approve "Determination of Vitamin A in Infant Formula and Adult Nutritionals by UPLC-UV" as AOAC Official Method 2011.07. To move from First to Final Action status, it was recommended that additional information be generated for all types of infant formulas and adult nutritional formula matrixes at varied concentration levels, as indicated in the standard method performance requirements. International units or retinol equivalents typically represent the concentration of vitamin A in food and supplements. However, for the purpose of this method, the concentration represented is presented in microg/100 g.  相似文献   

17.
18.
During the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting" held on June 29, 2011, an Expert Review Panel (ERP) reviewed the method "Determination of Vitamin B12 in Infant Formula and Adult Nutritionals by HPLC." Under the new pathway to Official Methods, the ERP adopted the method as Official First Action. The method is applicable to the determination of vitamin B12 in infant formula and adult nutritionals. Data showed an average overall intermediate precision of 6.64% RSD, an estimated quantitation limit of 0.8 microg/kg, and a detection limit of 0.2 microg/kg in prepared samples. The standard range of the method is 2 to 200 microg/L, which corresponds to an analytical range of 0.8 to 500 microg/kg.  相似文献   

19.
Interlaboratory validation studies have been performed on 2 methods for the determination of chlormequat (CLQ) and mepiquat (MPQ). Both methods used identical extraction procedures and stable isotope internal standardization but differed in the use of liquid chromatography/mass spectrometry (LC/MS) or LC/tandem mass spectrometry (LC/MS/MS) for the determination, the amount of internal standard used, and the expected limit of detection. After addition of deuterated internal standards, CLQ and MPQ were extracted with methanol-water and determined by LC//MS or LC/MS/MS with positive electrospray ionization. Eight European laboratories participated in the LC/MS method study, analyzing mushroom, pear, wheat flour, and fruit puree with residues of CLQ in the range 0.040-1.19 mg/kg and of MPQ in the range 0.041-0.39 mg/kg. For CLQ, the Horwitz ratio (HoRat) values for individual test materials/levels were in the range 0.85-1.13 with a mean of 1.00, showing good method performance. For MPQ, the Ho values for mushroom, pear (both levels), and wheat flour were in the range 0.83-0.94, again indicating good method performance. For the determination of MPQ in infant food (fruit puree) at 0.041 mg/kg, the Ho was 1.7 when a value of 0 reported by one participant was excluded. In the LC/MS/MS study, in which 11 laboratories participated, a separate sample set was analyzed with residues of CLQ in the range 0.007-1.03 mg/kg and of MPQ in the range 0.008-0.72 mg/kg. Ho values for CLQ were in the range 0.27-1.36 and for MPQ in the range 0.51-2.10, all corresponding to acceptable method performance.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号