首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Abbaspour A  Mirzajani R 《Talanta》2004,64(2):435-441
Simultaneous determination of V(V) and Al(III) was performed by application of neural networks when the calibration matrix was performed using β-correction spectra. Two reactions between V(V) and Al(III) and Alizarin Red S (ARS) as a ligand have been investigated and applied for the simultaneous spectrophotometric determination of these metal ions. The parameters controlling behavior of the system were investigated and optimum conditions selected. Feed-forward neural networks have been trained to quantify considered metal ions in mixtures under optimum conditions. Sigmoidal functions were used in the hidden and output layers. Determinations were made over the concentration range 0.10-7.80 μg ml−1 of V(V) and 0.11-4.20 μg ml−1 of Al(III). Applying this method satisfactorily to simultaneous determination of these metal ions in several synthetic solutions with total relative standard error less than 4.02% validated the proposed method.  相似文献   

2.
Vanessa G.K. Almeida 《Talanta》2007,71(3):1047-1053
This paper reports the development of a reversed flow injection system for the spectrophotometric determination of Sb(III) and total Sb in antileishmanial drugs. The analytical system is based on the selective reaction between Sb(III) and bromopyrogallol red (BPR) with the decrease of the absorbance at 555 nm. Total Sb concentration was determined after reduction of all Sb(V) to Sb(III) with KI and ascorbic acid. The influence of system variables (chemical and flow type) and the possible interference of high amounts of Sb(V) on Sb(III) was studied as well as the suitable conditions for preparation of samples. It was verified that the use of Triton X-100 enhanced the sensitivity of the methodology and that the previous sonication of the samples was fundamental to achieve accurate results. Under optimized conditions the reversed FIA system was able to process 63 samples per hour with a detection limit of 29 ng ml−1 and a R.S.D. of 3.8% (0.25 μg ml−1 level). Real samples of commercial antileishmanial drugs were analyzed, being observed no statistical difference between the results obtained by the developed system and FAAS or manual methodology in relation to total Sb concentration.  相似文献   

3.
B.D. Real  L.A. Sarabia 《Talanta》2007,71(4):1599-1609
Using a central composite design, the signal of the process for the spectrophotometric determination of hexavalent chromium (λ = 543 nm) is maximised and its variability minimised using as complexing agent 1,5-diphenylcarbazide in sufficiently acid medium. To analyse the interference of various analytes (Mo(VI), V(V), Fe(III) and Mn(VII)) on the Cr(VI) as a function of concentration of interferent, a factorial design was prepared at three levels of each (zero, medium and high concentration), which implies performing 81 determinations. However, a D-optimal design with just nine experiments is sufficiently good to estimate the model proposed.The interference of these metals makes it impossible to determine Cr(VI) when they are present in the sample. To avoid prior separation steps, a multivariate regression by partial least squares, PLS, is proposed to calibrate the Cr(VI) in the presence of these analytes varying the concentration of the Cr(VI) between 0.1 and 0.9 μg ml−1 and that of the interferents between 3 and 5 μg ml−1. The average errors obtained were 4.5% and 3.29% fitted and in prediction, respectively, with a standard error in prediction (RMSEP) of 0.016% presenting absence of both constant and proportional bias.The detection limit with the PLS regression in the presence of interferents is 0.1 μg ml−1 with a probability of false positive equal to 5% and less than 5% for false negative. The capability of detection is similar to that obtained with the univariate calibration (absorbance at 543 nm) in absence of interferents.With the PLS regression it is possible to discriminate 0.085 μg ml−1 of Cr(VI) in a sample with 0.5 μg ml−1 of Cr(VI) with probabilities of false compliance and false non-compliance equal to 0.05. For the univariate calibration without interferents, it was established at 0.0971 μg ml−1 of Cr(VI) for the same nominal concentration.In relation to interference of V(V), Fe(III) and Mn(VII), the PLS calibration could be an efficient alternative to the separation step for Cr(VI) spectrophotometric determination using 1,5-diphenylcarbazide.  相似文献   

4.
The H-point standard addition method (HPSAM) was applied to kinetic data for simultaneous determination of Sb(V) and Sb(III) and also selectively determines Sb(V) in the presence of Sb(III). The method is based on the differences between rate of complexation of pyrogallol red with Sb(V) and Sb(III) at pH=2. Sb(V) can be determined in the range of 0.3-2.0 μg ml−1 with satisfactory accuracy and precision in the presence of excess Sb(III). Good selectivity was obtained over the variety of metal ions. The proposed method was used for determination of Sb(V) and Sb(III) in river and spring water samples.  相似文献   

5.
A simple chemiluminometric method using flow injection has been developed for the determination of paracetamol (acetaminophen), based on the chemiluminescence produced by the reduction of tris(2,2′-bipyridyl)ruthenium(III). The latter is obtained by oxidation of tris(2,2′-bipyridyl)ruthenium(II) by potassium permanganate in dilute sulphuric acid in the presence of paracetamol. A standard or sample solution was injected into the ruthenium(II) stream (flow rate 1.5 ml min−1) which was then merged with potassium permanganate in dilute sulphuric acid stream (flow rate 0.5 ml min−1). The chemiluminescence intensity is enhanced by the presence of manganese(II) ions. Under the optimum conditions, a linear calibration graph was obtained over the range of 0.3-50.0 μg ml−1 and the detection limit was 0.2 μg ml−1 (s/n = 3). The relative standard deviation of the proposed method calculated from 20 replicate injections of 5.0 μg ml−1 paracetamol was 1.1%. The sample throughput was 90 h−1. The method was successfully applied to the determination of paracetamol in commercial pharmaceutical formulations.  相似文献   

6.
A new method was developed for the simultaneous speciation of inorganic arsenic and antimony in water by on-line solid-phase extraction coupled with hydride generation-double channel atomic fluorescence spectrometry (HG-DC-AFS). The speciation scheme involved the on-line formation and retention of the ammonium pyrrolidine dithiocarbamate complexes of As(III) and Sb(III) on a single-walled carbon nanotubes packed micro-column, followed by on-line elution and simultaneous detection of As(III) and Sb(III) by HG-DC-AFS; the total As and total Sb were determined by the same protocol after As(V) and Sb(V) were reduced by thiourea, with As(V) and Sb(V) concentrations obtained by subtraction. Various experimental parameters affecting the on-line solid-phase extraction and determination of the analytes species have been investigated in detail. With 180 s preconcentration time, the enrichment factors were found to be 25.4 for As(III) and 24.6 for Sb(III), with the limits of detection (LODs) of 3.8 ng L− 1 for As(III) and 2.1 ng L− 1 for Sb(III). The precisions (RSD) for five replicate measurements of 0.5 μg L−1 of As(III) and 0.2 μg L−1 of Sb(III) were 4.2 and 4.8%, respectively. The developed method was validated by the analysis of standard reference materials (NIST SRM 1640a), and was applied to the speciation of inorganic As and Sb in natural water samples.  相似文献   

7.
Study on simultaneous speciation of arsenic and antimony by HPLC-ICP-MS   总被引:1,自引:0,他引:1  
A method was developed for the simultaneous speciation of arsenic and antimony with HPLC-ICP-MS using C30 reversed phase column. Eight kinds of arsenic compounds (As(III), As(V), monomethylarsonic acid (MMAA), dimethylarsinic acid (DMAA), arsenobetaine (AB), arsenocholine (AsC), trimethylarsine oxide (TMAO) and tetramethylarsonium (TeMA)), Sb(III) and Sb(V) were simultaneously separated by the special mobile phase containing ammonium tartrate. Especially for the species of organic As, a C30 column was better than a C18 column in the effect of separation. Limits of detection (LOD) for these elements were 0.2 ng ml−1 for the species of each As, and 0.5 ng ml−1 for the species of each Sb, when a 10 μl of sample was injected, respectively. The proposed method was applied to a hot spring water and a fish sample.  相似文献   

8.
A novel disk electrochemical hydride generator has been developed for the determination of As and Sb. Compared with the traditional thin-layer cell, the disk cell combined the advantages of quick assembly and easy operation. This electrochemical system for hydride generation in neutral buffer solutions has been studied for analytical usefulness in coupling with atomic fluorescence spectrometry. It was found that the use of neutral phosphate buffer solution could markedly increase the fluorescence intensity of As(III) and Sb(III) and reduce the impact of cathode erosion on the stability of signal intensity. At the same time, the fluorescence intensity of As(V) and Sb(V) were almost suppressed totally. The detection limits (3σ) of 0.031 μg L−1 As(III) and 0.026 μg L−1 Sb(III) in aqueous solutions were obtained, respectively. The precisions (n = 11) for 20 μg L−1 As(III) and Sb(III) were 2.0% and 2.7%, respectively. The method was successfully applied for determination of different oxidation states of As and Sb in environmental samples.  相似文献   

9.
In the present paper, we develop a methodology for antimony speciation in occupationally exposed human urine samples by high-performance liquid chromatography with hydride generation atomic fluorescence spectrometry (HPLC-HG-AFS). The methodology was applied to the determination of Sb(V), Sb(III) and (CH3)3SbCl2 (TMSb(V)). Retention time of Sb(V), Sb(III) and TMSb(V) species were 0.88, 2.00 and 3.61 and the detection limits were 0.18, 0.19 and 0.12 μg L− 1, for 100 μL loop injection respectively which is considered useful for elevated/occupationally exposed urine samples. Studies on the stability of antimony species in urine samples on the function of the elapsed time of preservation (4 °C) and storage (− 70 °C) were performed. Results revealed that antimony species are highly unstable at − 70 °C, probably due to co-precipitation reaction. In this kind of matrix transformation during preservation time may occur, such as oxidation of Sb(III) to Sb(V) and transformation into species that do not elute from the column. EDTA shows that it is able to stabilize Sb(III) for more than one week of preservation time at 4 °C avoiding co-precipitation during storage at − 70 °C. Finally the methodology was applied to occupationally exposed human urine samples. 25% of specimens present antimony levels (Sb(V)) of more than 5 μg L− 1.  相似文献   

10.
The possibility of applying antimony-film modified glassy carbon electrode in sequential-injection analysis (SIA) was investigated with the objective of determining Pb(II) and Cd(II) by anodic stripping voltammetry (ASV). The conditions of antimony-film deposition concerning composition of the plating/carrier solutions, concentrations of Sb(III) and hydrochloric acid, effects of different supporting electrolyte salts, and plating potential were optimized. It was found that the antimony-film deposition on glassy carbon substrate in a sample solution consisting of 750 μg L−1 Sb(III), 0.5 mol L−1 HCl at −1.5 V (vs. Ag/AgCl/3 mol L−1 KCl) yielded a modified electrode suitable for the determination of Pb(II) and Cd(II) at the μg L−1 level. The reproducibility of the analytical signals was characterized by a relative standard deviation lower than 2.8%, and the calculated values of detection limits were 1.2 μg L−1 for Pb(II) and 1.4 μg L−1 for Cd(II). The presence of KSCN in the sample solution offers the possibility of detecting ions with more negative oxidation potentials like Zn(II), Mn(II) or Cr(III). The developed SIA-ASV procedure was compared with the commonly used batch method, and its applicability was tested on a spiked tap water sample.  相似文献   

11.
A simple and sensitive method has been developed for the direct determination of toxic species of antimony in mushroom samples by hydride generation atomic fluorescence spectrometry (HG AFS). The determination of Sb(III) and Sb(V) was based on the efficiency of hydride generation employing NaBH4, with and without a previous KI reduction, using proportional equations corresponding to the two different measurement conditions. The extraction efficiency of total antimony and the stability of Sb(III) and Sb(V) in different extraction media (nitric, sulfuric, hydrochloric, acetic acid, methanol and ethanol) were evaluated. Results demonstrated that, based on the extraction yield and the stability of extracts, 0.5 mol L− 1 H2SO4 proved to be the best extracting solution for the speciation analysis of antimony in mushroom samples. The limits of detection of the developed methodology were 0.6 and 1.1 ng g− 1 for Sb(III) and Sb(V), respectively. The relative standard derivation was 3.8% (14.7 ng g− 1) for Sb(V) and 5.1% (4.6 ng g− 1) for Sb(III). The recovery values obtained for Sb(III) and Sb(V) varied from 94 to 106% and from 98 to 105%, respectively. The method has been applied to determine Sb(III), Sb(V) and total Sb in five different mushroom samples; the Sb(III) content varied from 4.6 to 11.4 ng g− 1 and Sb(V) from 14.7 to 21.2 ng g− 1. The accuracy of the method was confirmed by the analysis of a certified reference material of tomato leaves.  相似文献   

12.
In this work, a non-chromatographic procedure for the on-line determination of ultratraces of V(V) and V(IV) is presented. The method involves a solid phase extraction-flow injection system coupled to electrothermal atomic absorption spectrometry (SPE-FI-ETAAS). The system holds two microcolumns (MC) set in parallel and filled with lab-made mesoporous silica functionalized with 3-aminopropyltriethoxy silane (APS) and mesoporous silica MCM-41, respectively. The pre-concentration of V(V) is performed by sorption onto the first MC (C1) filled with APS at pH 3, whilst that of V(IV) is performed by sorption onto the second column (C2) filled with mesoporous silica MCM-41 at pH 5. Aqueous samples containing both analytes are loaded and, after pre-concentration (pre-concentration factor PCF = 10, sorption flow rate = 1 mL min−1, sorption time = 10 min), they are eluted in separate vessels with hydroxylammonium chloride (HC) 0.1 mol L−1 in HCl 0.5 mol L−1 (elution volume = 1 mL, elution flow rate = 0.5 mL min−1). Afterwards, both analytes are determined through ETAAS with graphite furnace. Under optimized conditions, the main analytical figures of merit for V(V) and V(IV) are, respectively: detection limits (3 s): 0.5 and 0.6 μg L−1, linear range: 2-100 μg L−1 (both analytes), sensitivity: 0.015 and 0.013 μg−1 L and sample throughput: 6 h−1 (both analytes). Recoveries of both species were assayed in different water samples. Validation was performed through certified reference materials for ultratraces of total vanadium in river water.  相似文献   

13.
Ezel Boyac?  Talal Shahwan 《Talanta》2010,80(3):1452-1525
A natural biosorbent containing amine functional groups, chitosan, and a novel sorbent, chitosan-immobilized sodium silicate, were prepared and utilized for the selective sorption of As(V) from waters prior to its determination by atomic spectrometric techniques, namely, hydride generation atomic absorption spectrometry (HGAAS) and inductively coupled plasma mass spectrometry (ICP-MS). Chitosan was synthesized from chitin and sodium silicate was used as the immobilization matrix due to its straightforward synthesis. Through sequential sorption studies, it was shown that chitosan-immobilized sodium silicate has exhibited a better chemical stability than the chitosan itself which demonstrates the advantage of immobilization method. Both chitosan and chitosan-immobilized sodium silicate were shown to selectively adsorb As(V), arsenate, from waters at pH 3.0 at which neither chitin nor sodium silicate displayed any sorption towards As(V). The sorption of arsenate by chitosan is supposed to have electrostatic nature since pH of 3.0 is both the point at which the amino groups in chitosan are protonated and also the predominant form of As(V) is H2AsO4. A pre-oxidation step is required if both As(III) and As(V) are to be determined. Desorption from the sorbents was realized with 1.0% (w/v) l-cysteine prepared in a pH 3.0 solution adjusted with HCl. Among the possible interfering species tested, only Te(IV) and Sb(III) were shown to cause a decrease in the sorption capacity especially at high interferant concentrations. High concentrations of Sb(III) also resulted in gas phase interference during hydride generation.The validity of the method was checked both via spike recovery experiments and also through the analysis of a standard reference material. Spike recovery tests were carried out with four different types of water; namely, ultra-pure, bottled drinking, tap, and sea water; and percent recovery values were found to be 114 (±4), 112 (±2), 43 (±4), and 0 (±1), respectively. It was concluded that the proposed methodology can be applied efficiently to low-to-medium ionic strength solutions, such as most drinking waters. The accuracy of the method was additionally investigated through the analysis of a standard reference material and a good correlation was found between the determined (26.6 ± 2.4 μg L−1) and the certified (26.67 μg L−1) value.  相似文献   

14.
Continuous flow chemical hydride generation coupled directly to a 40 W, atmospheric pressure, 2.45 GHz microwave microstrip Ar plasma operated inside a capillary channel in a sapphire wafer has been optimized for the emission spectrometric determination of As and Sb. The effect of the NaBH4 concentration, the concentration of HCl, HNO3 and H2SO4 used for sample acidification, the Ar flow rate, the reagent flow rates, the liquid volume in the separator as well as the presence of interfering metals such as Fe, Cu, Ni, Co, Zn, Cd, Mn, Pb and Cr, was investigated in detail. A considerable influence of Fe(III) (enhancement of up to 50 %) for As(V) and of Fe(III), Cu(II) and Cr(III) (suppression of up to 75%) as well as of Cd(II) and Mn(II) (suppression by up to 25%) for Sb(III) was found to occur, which did not change by more than a factor of 2 in the concentration range of 2–20 μg ml− 1. The microstrip plasma tolerated the introduction of 4.2 ml min− 1 of H2 in the Ar working gas, which corresponded to an H2/Ar ratio of 28%. Under these conditions, the excitation temperature as measured with Ar atom lines and the electron number density as determined from the Stark broadening of the Hβ line was of the order of 5500 K and 1.50 · 1014 cm− 3, respectively. Detection limits (3σ) of 18 ng ml− 1 for As and 31 ng ml− 1 for Sb were found and the calibration curves were linear over 2 orders of magnitude. With the procedure developed As and Sb could be determined at the 45 and 6.4 μg ml− 1 level in a galvanic bath solution containing 2.5% of NiSO4. Additionally, As was determined in a coal fly ash reference material (NIST SRM 1633a) with a certified concentration of As of 145 ± 15 μg g− 1 and a value of 144 ± 4 μg g− 1 was found.  相似文献   

15.
Liquid-liquid extraction preconcentration technique which allows the achievement of extremely high ratio between the aqueous and organic phase was specified as semi-microextraction. A modified highly effective liquid phase semi-microextraction (LSME) procedure was developed for preconcentration and determination of ultra trace levels of inorganic antimony species in environmental waters using electrothermal atomic absorption spectrometry (ETAAS) for quantification. Antimony(III) species were selectively extracted as dithiocarbamate complexes from 100 mL aqueous phase into 250 μL xylene at pH range of 5-8. Total Sb was determined using the same extraction system over a sample acidity range of pH 0-1.2 without the need for pre-reduction of Sb(V) to Sb(III). The concentration of Sb(V) was obtained as the difference between that of total antimony and Sb(III). With an 8 min extraction an enrichment factor of 400 was achieved. The limit of detection (3 s) was 2 ng L−1 Sb. The method was not affected by the presence of up to 0.01% humic acid, 0.025 mol L−1 EDTA, 0.01 mol L−1 tartaric acid and 0.001 mol L−1 F. Recoveries of spiked Sb(III) and Sb(V) in river, tap, and sea water samples ranged from 93 to 108%. The results for total antimony concentration in the river water reference material SLRS-5 were in good agreement with the information value. The procedure was applied to the determination and quantification of dissolved antimony species in natural waters.  相似文献   

16.
Fan J  Wang A  Feng S  Wang J 《Talanta》2005,66(1):236-243
A new sequential injection spectrophotometric method was proposed for the determination of metoclopramide and tetracaine hydrochloride. The method was based on the detection of an unstable red intermediate compound resulting from the reaction of metoclopramide or tetracaine hydrochloride with potassium dichromate, in the presence of sodium oxalate, in sulfuric acid solution. The related reaction mechanisms of this new method have been studied. The experimental conditions were optimized for the stopped-flow and continuous-flow sequential injection models. For continuous flow, the linear range for determination of metoclopramide, the detection limit and the sampling frequency were 13-130 μg ml−1, 9.4 μg ml−1 and 40 samples per hour, respectively. For stopped flow, they were 3-42 μg ml−1, 1.0 μg ml−1 and 18 h−1, respectively. Adopting the continuous-flow model for tetracaine hydrochloride, the linear range was 25-300 μg ml−1, and the detection limit was 18.0 μg ml−1 with sampling frequency of 40 h−1. This method has been used to determine metoclopramide and tetracaine hydrochloride in pharmaceutical preparations, and the results are compared with those determined by the pharmacopoeia method. Statistical analysis reveals that there was no evidence of significant difference between the methods.  相似文献   

17.
Atomic fluorescence spectrometry was used as an element-specific detector in hybridation with liquid chromatography (LC) and hydride generation for the speciation of Sb(III), Sb(V) and trimethylantimony dichloride (TMSbCl2). The three species were poorly resolved in a single chromatogram but good results were obtained by anion-exchange chromatography, using a mobile phase with 20 mM EDTA and 8 mM hydrogenphthalate to separate Sb(III) and Sb(V) and 1 mM carbonate at pH 10 to separate Sb(V) and TMSbCl2. Calibration graphs were linear between 2 and 100 μg l−1. Detection limits were 0.9, 0.5 and 0.7 μg l−1 for Sb(III), Sb(V) and TMSbCl2, respectively. The method was applied to the speciation of antimony in environmental samples.  相似文献   

18.
Quiroz W  Olivares D  Bravo M  Feldmann J  Raab A 《Talanta》2011,84(2):593-598
HG-AFS is highly sensitive and low cost detection system and its use for antimony chemical speciation coupled to HPLC is gaining popularity. However speciation analysis in soils is strongly hampered because the most efficient extractant reported in the literature (oxalic acid) strongly inhibits the generation of SbH3 by Sb(V), the major species in this kind of matrix, severely affecting its detection limits. The purpose of this research is to reduce the detection limit of Sb(V), by using a post column on-line reduction system with l-cysteine reagent (HPLC/pre-reduction/HG-AFS). The system was optimized by experimental design, optimum conditions found were 2% (w/v) and 10 °C temperature coil. Detection limits of Sb(V) and Sb(III) in oxalic acid (0.25 mol L−1) were improved from 0.3 and 0.1 μg L−1 to 0.07 and 0.07 μg L−1, respectively. The methodology developed was applied to Chilean soils, where Sb(V) was the predominant species.  相似文献   

19.
A new method was developed for simultaneous determination of trace arsenic and antimony in Chinese herbal medicines by hydride generation-double channel atomic fluorescence spectrometry with a Soxhlet extraction system and an n-octanol-water extraction system, respectively. The effects of analytical conditions on the fluorescence intensity were investigated and optimized. A water-dissolving and methanol-water-dissolving capability were compared. The contents of different species in five Chinese herbal medicines and their decoctions were analyzed. The concentration ratios of n-octanol-soluble As or Sb to water-soluble As or Sb were related to the kinds of medicine and the acidity of the decoction. Soxhlet extraction was found to be an effective method for plants pretreatment for determination of arsenic and antimony species in Chinese herbs; the interferences of coexisting ions were evaluated. The proposed method has the advantages of simple operation, high sensitivity and high speed, with 3σ detection limits of 0.094 μg g−1 for As(III), 0.056 μg g−1 for total As, 0.063 μg g−1 for Sb(III) and 0.019 μg g−1 for total Sb in a 1.0 g of the sample.  相似文献   

20.
Jitmanee K  Oshima M  Motomizu S 《Talanta》2005,66(3):529-533
A novel and simple flow-based method was developed for the simultaneous determination of As(III) and As(V) in freshwater samples. Two miniature columns with a solid phase anion exchange resin, placed on two 6-way valves were utilized for the solid-phase collection/concentration of arsenic(III) and arsenic(V), respectively. As(III) could be retained on the column after its oxidation to As(V) species with an oxidizing agent. The collected analytes were then sequentially eluted by 2 M nitric acid and introduced into ICP-AES. Potassium permanganate was examined as potential oxidizing agent for conversion of As(III) to As(V). The standard deviation of the analytical signals (peak height) for the replicate analysis (n = 5) of 0.5 μg l−1 solution were 3 and 5% for As(III) and As(V), respectively. The limit of detection (3σ) for both As(III) and As(V) were 0.1 μg l−1. The proposed system produced satisfactory results on the application to the direct analysis of inorganic arsenic species in freshwater samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号