首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
通过水热法在长有ZnO籽晶层的柔性聚酰亚胺(PI)衬底上生长了整齐的ZnO纳米棒,ZnO纳米棒的晶体结构和表面形貌通过X射线衍射(XRD)、扫描电子显微镜(SEM)等进行表征.通过静电吸附方式,将葡萄糖氧化酶(GOx)固定在其表面.分别对GOx及修饰前后的ZnO纳米棒进行了紫外-可见光谱表征,发现修饰后存在ZnO的吸收峰和GOx的特征吸收峰,表明GOx固定在ZnO表面.通过对修饰样品进行傅里叶变换红外(FTIR)光谱测试发现了与GOx相关的吸收峰,这进一步表明GOx仍保持生物活性.最后在循环伏安曲线的测试中,这种在柔性衬底上制备的生物酶电极表现出非常灵敏的电流响应,为制备柔性葡萄糖生物传感器奠定了实验基础.  相似文献   

2.
《Electroanalysis》2006,18(23):2375-2380
Reagentless glucose‐detecting biosensors were constructed by incorporating a series of phenothiazine derivatives as mediators onto chitosan (CHIT) matrix via different covalent bonds, wherein glucose oxidase (GOx) was employed as the enzyme. Electrochemical studies show significant decrease in the electrocatalytic current during cyclic voltammetric and amperometric measurements, resulting from complexes formation between GOx and phenothiazine molecules. This behavior was further verified by spectroscopic studies. The decrease in the peak intensity at 258 nm is due to the gradual complexes formation over time, consistent to the decrease in the current signal in electrochemical investigations. Correlation with the molecular structures of phenothiazine derivatives reveals a strong relationship between the hydrophobicity of the mediators and the stability of the biosensor electrodes.  相似文献   

3.
Glucose oxidase (GOx) was immobilized in the organic-inorganic Langmuir-Bldogett (LB) films consisting of octadecyltrimethylammonium (ODTA) and nanosized Prussian blue (PB) clusters. The amperometric glucose biosensors based on the LB films were fabricated and tested. It was found that the sensors exhibited a clear response current under an applied voltage of 0.0 V (vs Ag/AgCl). The linearity of current density versus glucose concentration was confirmed below 15 mmol/L concentration. This is the first observation of biosensor function of the hybrid organic-inorganic LB films. The successful preparation of glucose sensors operating at the very low potential indicates that the adsorbed PB clusters in the LB films act as an electrocatalyst for the electrochemical reduction of hydrogen peroxide, which is the final product of the enzymatic reaction sequence. The observed low potential applicability is estimated to inhibit the responses of interferants such as ascorbic acid, uric acid, and acetominophen. It was also found that an electrostatic interaction between positively charged ODTA+ and the adsorbed species of both GOx and PB provided a stabilized adsorption state in the LB films. Such stable immobilization contributes to the steady amperometric response current observed in the present ODTA/PB/GOx LB films.  相似文献   

4.
Luque GL  Rodríguez MC  Rivas GA 《Talanta》2005,66(2):467-471
The performance of amperometric glucose biosensors based on the dispersion of glucose oxidase (GOx) and copper oxide within a classical carbon (graphite) paste composite is reported in this work. Copper oxide promotes an excellent electrocatalytic activity towards the oxidation and reduction of hydrogen peroxide, allowing a large decrease in the oxidation and reduction overpotentials, as well as an important enhancement of the corresponding currents. Therefore, it is possible to perform the glucose biosensing at low potentials where there is no interference even in large excess of ascorbic acid, uric acid or acetaminophen. The influence of the copper oxide and glucose oxidase content in the paste on the analytical performance of the bioelectrode is discussed. The resulting biosensor shows a fast response, a linear relationship between current and glucose concentration up to 1.35 × 10−2 M (2.43 g L−1) and a detection limit of 2.0 × 10−5 M. The effect of the presence of the enzyme in the composite material on the dispersion of the copper oxide particles is also discussed.  相似文献   

5.
This work reports the advantages of carbon paste electrodes modified with electrogenerated magnetite nanoparticles. The nanoparticles present catalytic activity towards hydrogen peroxide reduction. The incorporation of glucose oxidase (GOx) and magnetite in a carbon paste matrix have made possible the development of an efficient glucose biosensor. The effect of the amount of GOx and magnetite present in the composite on the response of the biosensor was critically evaluated. The biosensors demonstrated to be highly selective, with negligible interference of ascorbic acid and uric acid. The proposed biosensor was challenged with human blood serum demonstrating an excellent correlation with the spectrophotometric method.  相似文献   

6.
In recent years, graphene has been widely used as a high performance two-dimensional material in the development of biosensors and biofuel cells for facilitating direct electron transfer (DET) of glucose oxidase (GOx). However, almost all of these reports perform experiments in the presence of oxygen (a natural mediator of oxidase) and whether the GOx with DET property retained their catalytic activity in the absence of mediators has not been studied in detail so far. In this paper, we investigated the DET property and enzyme activity of GOx on graphene surface without and with mediators. Experimental results showed that the biosensor had no response to glucose in mediator-free solutions, even though the DET of GOx was observed, indicating that the GOx with DET property lacked enzymatically catalytic activity. However, in the presence of mediators, the biosensor showed sensitive response to glucose, illustrating that the mediated enzymatic oxidation of glucose occurred, which can be attributed to the catalytically active GOx without DET capability. These results suggest that DET property and enzyme catalytic activity cannot occur on the same GOx simultaneously. Therefore, keeping enzyme activity and DET of GOx at the same time is still a major challenge for biosensor and biofuel cell researches.  相似文献   

7.
The fabrication of amperometric biosensors based on whole cell Gluconobacter oxydans DSMZ 2343 (G. oxydans) and glucose oxidase (GOx) was performed for the detection of glucose. Glassy carbon electrodes (GCE) were coated with a 10-(4H-dithiyeno [3,2-b:2’,3’-d]pyroll-4-il)decan-1-amine (DTP-alkyl-NH2) polymer using an electropolymerization method and the formed interface was used to connect the bacteria and the enzyme to the electrode. The transfer of electrons from enzyme to electrode was successfully demonstrated by the biocatalytic activity and unique morphology of the conducting polymer. Characterization of the biosensors was assessed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM) analyses. The detection limits of the enzyme and microbial based biosensors for glucose were 0.022 and 0.081?mM, respectively. The broad linear dynamic ranges of the GOx and G. oxydans biosensors were observed to be 0.045–50.0 and 0.19–50.0?mM, respectively. The analytical performances of biosensors were compared according to the following figures of merit: detection limits, limits of quantification, pH and current response time. In addition, to demonstrate the applicability of the biosensors, real-time measurements and recovery studies were evaluated.  相似文献   

8.
One of the major problems in amperometric biosensors based on detection of H2O2 produced by enzymatic reaction between oxidase enzymes and substrate is the interference of redox active compounds such as ascorbic acid (AA), dopamine (DA) and uric acid (UA). To minimize these interferences, sodium bismuthate was used for the first time as an insoluble pre‐oxidant in the flow injection (FI) amperometric glucose biosensor at a Glucose oxidase (GOx) immobilized Pt/Pd bimetallic modified pre‐anodized pencil graphite electrode (p.PGE). In this context, these interfering compounds were injected into a flow injection analysis (FIA) system using an injector which was filled with NaBiO3. Thus, these interferents were converted into their redox inactive oxidized forms before reaching the electrode in the flow cell. While glucose was not influenced by the pre‐oxidant in the injector, the huge oxidation peak currents of the interferents decreased significantly in the biosensor. FI amperometric current time curves showed that the AA, DA and UA were minimized by 96 %, 86 %, and 98 % respectively, in the presence of an equivalent concentration of interferences in a 1.0 mM glucose solution. The proposed FI amperometric glucose biosensor exhibits a wide linear range (0.01–10 mM, R2=0.9994) with a detection limit of 2.4×10?3 mM. Glucose levels in the artificial serum and two real samples were successfully determined using the fabricated FI amperometric biosensor.  相似文献   

9.
Xia Chu  Daxue Duan  Guoli Shen  Ruqin Yu 《Talanta》2007,71(5):2040-2047
A new amperometric biosensor for glucose was developed based on adsorption of glucose oxidase (GOx) at the gold and platinum nanoparticles-modified carbon nanotube (CNT) electrode. CNTs were covalently immobilized on gold electrode via carbodiimide chemistry by forming amide linkages between carboxylic acid groups on the CNTs and amine residues of cysteamine self-assembled monolayer (SAM). The fabricated GOx/Aunano/Ptnano/CNT electrode was covered with a thin layer of Nafion to avoid the loss of GOx in determination and to improve the anti-interferent ability. The immobilization of CNTs on the gold electrode was characterized by quartz crystal microbalance technique. The morphologies of the CNT/gold and Ptnano/CNT/gold electrodes have been investigated by scanning electron microscopy (SEM), and the electrochemical performance of the gold, CNT/gold, Ptnano/gold and Ptnano/CNT/gold electrodes has also been studied by amperometric method. In addition, effects of electrodeposition time of Pt nanoparticles, pH value, applied potential and electroactive interferents on the amperometric response of the sensor were discussed.

The enzyme electrode exhibited excellent electrocatalytic activity and rapid response for glucose in the absence of a mediator. The linear range was from 0.5 to 17.5 mM with correction coefficient of 0.996. The biosensor had good reproducibility and stability for the determination of glucose.  相似文献   


10.
In this work, three types of electrodes suitable for amperometric glucose biosensors were designed. One type of electrode was based on bio‐selective layer of polypyrrole/(glucose oxidase)/(Prussian Blue) (Ppy/GOx/PB) and it was used as a control electrode regarding to which electrochemical properties of two other types of electrodes were compared. During the formation of Prussian blue layers graphite electrodes were additionally modified by Ni‐hexacyanoferrate (NiHCF) and by Co‐hexacyanoferrate (CoHCF) in order to design Ppy/GOx/PB‐NiHCF and Ppy/GOx/PB‐CoHCF electrodes, respectively. Some physicochemical characteristics of all three types of electrodes were evaluated and compared. The Ppy/GOx/PB‐NiHCF electrode showed wider linear range of the calibration curve than Ppy/GOx/PB and Ppy/GOx/PB‐CoHCF electrodes. The effect of temperature on analytical performance of the Ppy/GOx/PB‐NiHCF based biosensor has been evaluated and activation energy of enzyme catalysed reaction has been calculated within the temperature range of 15 °C to 30 °C.  相似文献   

11.
采用石英晶体微天平(QCM)技术, 监测了裸金(Au)电极、电沉积纳米金的金电极(Aued/Au)、多壁碳纳米管(MWCNTs)修饰的金电极(MWCNTs/Au)以及MWCNTs 修饰后再电沉积纳米金的金电极(Aued/MWCNTs/Au)上葡萄糖氧化酶(GOx)的吸附过程, 测算了吸附固定的GOx质量. 通过阳极恒电位检测吸附酶与葡萄糖发生酶反应所产生的过氧化氢, 考察了这些酶电极的安培响应, 并测算了各吸附态GOx的质量比生物活性(MSBAi).也通过循环伏安法研究酶的直接电化学, 测算了各吸附态GOx的电活性百分数(EAPi). 实验结果表明, 酶吸附量和酶电极的安培响应满足MWCNTs/Au > Aued/MWCNTs/Au > Aued/Au > Au 的顺序; MSBAi满足Au > Aued/MWCNTs/Au > Aued/Au > MWCNTs/Au的顺序; 而EAPi则满足MWCNTs/Au > Aued/MWCNTs/Au > Aued /Au > Au的顺序. 根据酶和纳米材料的亲疏水作用以及酶的吸附量对实验结果进行了合理解释, 也定量验证了电极上吸附酶分子的总生物活性与酶电极的安培响应呈正相关关系, 所得数据和结论有助于纳米材料固定酶及其安培酶电极的研究.  相似文献   

12.
Different carbonaceous materials, such as single‐walled carbon nanotubes (SWCNTs) and glassy carbon submitted to an electrochemical activation at +1.80 V (vs. SCE) for 900 s, have been used with the aim of comparing their performances in the development of enzyme electrodes. Commercial SWCNTs have been pretreated with 2.2 M HNO3 for 20 h prior to use. The utility of activated GC as promising material for amperometric oxidase‐based biosensors has been confirmed. With glucose oxidase (GOx) as a model enzyme, glucose was efficiently detected up to 1 mM without the use of a mediator. Both electrodes operated in stirred solutions of 0.1 M phosphate buffer (pH 5.5), containing dissolved oxygen, at a potential of ?0.40 V vs. SCE. Although the performances of the two carbonaceous materials were comparable, the biosensors based on activated GC were characterized by a practically unchanged response 40 days after the fabrication, a better signal to noise ratio, and a little worse sensitivity. In addition, the preparation procedure of such biosensors was more simple, rapid and reproducible.  相似文献   

13.
《Analytical letters》2012,45(12):2373-2389
ABSTRACT

The performance of a first generation glucose amperometric biosensor based on the entrapment of glucose oxidase (GOx) within a net of copper electrodeposited onto activated glassy carbon electrode, is described. The copper electrodeposited offers an efficient electrocatalytic activity towards the reduction of enzymatically-liberated hydrogen peroxide, allowing for a fast and sensitive glucose quantification. The influence of the electrodeposition conditions (pH, potential, time, copper salt and enzyme concentrations) on the response of the bioelectrode was evaluated from the amperometric signals of hydrogen peroxide and glucose. The combination of copper electrodeposition with a nation membrane allows an excellent selectivity towards easily oxidizable compounds such as uric and ascorbic acids at an operating potential of -0.050 V. The response is linear up to 2.0 × 10?2 M glucose, the detection limit being 1.2 × 10?3 M.  相似文献   

14.
将NaAuCl4、葡萄糖氧化酶(GOx)和葡萄糖混合,借一步酶促反应制得吸附GOx的金纳米颗粒(AuNPs),再通过滴干修饰法研制了Nafion/GOx-AuNPs修饰的玻碳(GC)电极,并考察了该酶电极上GOx的直接电化学和生物传感性能. 这种酶法合成的GOx-AuNPs复合物有良好的酶直接电化学活性,也保持了GOx的生物活性,似可归因于酶法合成的纳米金更接近酶氧化还原活性中心的缘故. 该酶电极在-0.4 V(vs. SCE)电位下,其稳态电流下降与葡萄糖浓度(0.5 4 mmol·L-1)成正比,检测下限0.2 mol·L-1.  相似文献   

15.
Vanesa Sanz 《Talanta》2009,78(3):846-965
A new approach for glucose determination in blood based on the spectroscopic properties of blood hemoglobin (Hb) is presented. The biosensor consists of a glucose oxidase (GOx) entrapped polyacrylamide (PAA) film placed in a flow cell. Blood is simply diluted with bidistilled water (150:1, v:v) and injected into the carrier solution. When reaching the PAA film, the blood glucose reacts with the GOx and the resulting H2O2 reacts with the blood Hb. This produces an absorbance change in this compound. The GOx-PAA film can be used at least 100 times. Lateral reactions of H2O2 with other blood constituents are easily blocked (by azide addition). The linear response range can be fitted between 20 and 1200 mg dL−1 glucose (R.S.D. 4%, 77 mg dL−1). In addition to the use of untreated blood, two important analytical aspects of the method are: (1) the analyte concentration can be obtained by an absolute calibration method; and (2) the signal is not dependent on the oxygen concentration.A mathematical model relating the Hb absorbance variation during the reaction with the glucose concentration has been developed to provide theoretical support and to predict its application to other compounds after changing the GOx by another enzyme. The method has been applied to direct glucose determination in 10 blood samples, and a correlation coefficient higher than 0.98 was obtained after comparing the results with those determined by an automatic analyzer. As well as sharing some of the advantages of disposable amperometric biosensors, the most significant feature of this approach is its reversibility.  相似文献   

16.
A strong oxidant membrane is introduced to amperometric biosensors in order to solve the problem associated with interference from readily oxidizable species. The proposed biosensors are in planar format, and are composed of four components, i.e. a base amperometric transducer, an enzyme layer, a protecting membrane, and an oxidant membrane. In this sensor format, interfering species are removed by an oxidation reaction during their diffusion through the oxidant membrane. The oxidant membrane is introduced by dispensing a mixture of an oxidant and a polymer matrix as dissolved in an organic solvent, and thus, could be easily adapted to mass fabrication of miniature biosensors. In this work, several different reagents are examined as oxidants: BaO2, CeO2, MnO2 and PbO2. Of these, PbO2 is shown to yield biosensors with the best performance, in terms of reducing interfering signals. Two different matrix systems are devised for use in formulating oxidant membranes: hydrophilic polyurethane (HPU) and cellulose acetate incorporating poly(ethylene glycol) (CA/PEG). While the CA/PEG-type sensor displays better sensitivity and faster response behavior, the HPU-type is shown to exhibit more pronounced interference-removing ability. The analytical utility of the proposed oxidant membrane is demonstrated by fabricating amperometric glucose and creatinine sensors as the model biosensor systems, and by investigating their response characteristics.  相似文献   

17.
Mailley P 《Talanta》2001,55(5):1005-1013
The electrocatalytic detection of products issued from enzymatic reactions occuring at biosensor interfaces can be improved owing to metal microparticle dispersions. This contribution describes the faesability of this concept for the modification poly(pyrrolylalkylammonium) films containing an enzyme through the inclusion of platinum. A model enzyme, glucose oxidase (GOx) was employed to demonstrate the reliability of this approach through the design of an amperometric glucose biosensors. The obtained composite assemblies were characterised regarding their sensing capabilities toward glucose. Platinum particles incorporation was operated within the biofilms to obtain a suitable sensitivity of the biosensor to glucose at a lower operational oxidation potential (eg 0.5 V/SCE) than the oxidation potential generally observed for hydrogen peroxide detection onto carbon electrodes. The incorporation procedure of platinum aggregates has been optimised to design biosensors exhibiting a sensitivity of about 8 mA. M(-1) cm(-2).  相似文献   

18.
Conductive cellulose-multiwalled carbon nanotube (MWCNT) matrix with a porous structure and good biocompatibility has been prepared using a room temperature ionic liquid (1-ethyl-3-methylimidazolium acetate) as solvent. Glucose oxidase (GOx) was encapsulated in this matrix and thereby immobilized on a glassy carbon surface. The direct electron transfer and electrocatalysis of the encapsulated GOx has been investigated using cyclic voltammetry and chronoamperometry. The GOx exhibited a pair of stable, well defined and nearly symmetric reversible redox peaks. The experimental results also demonstrate that the immobilized GOx retains its biocatalytic activity toward the oxidation of glucose and therefore can be employed in a glucose biosensor. The results show that the bioelectrode modified by the cellulose-MWCNT matrix has potential for use in biosensors and other bioelectronics devices.  相似文献   

19.
The use of biotinylated alginate as an immobilization matrix of enzymes on the surface of the amperometric transducer is described herein. The model used is that of the well-established glucose detection. Several types of immobilization protocols were tested. In the exception of one protocol, biotin labeled glucose oxidase was shown to first require conjugation with avidin, before its immobilization onto a biotin-alginate gel matrix. The response of the biosensors to incremental additions of glucose, was measured by potentiostating the modified electrodes at 0.6 V/SCE. The permeability of the modified electrodes was thereafter measured by using rotating disk electrode (RDE) voltammetry with ferrocenemonocarboxylic acid as the electroactive probe.  相似文献   

20.
Gold nanoparticles have demonstrated to be a very useful material for the construction of stable and sensitive glucose oxidase (GOx) amperometric biosensors. However, as for other enzyme electrodes, the lack of specificity for glucose limits their practical applications. Coupling biosensor responses with chemometric tools can be used to solve complex analytical signals from mixtures of species with similar properties. In this work, an amperometric biosensor based on a colloidal gold—cysteamine—gold disk electrode with the enzyme GOx and a redox mediator, tetrathiafulvalene (TTF), co‐immobilised atop the modified electrode, was used for the simultaneous determination of glucose and its common interferences, ascorbic acid and uric acid, in mixtures. Analytical data obtained from cyclic voltammograms generated with the biosensor were processed using an artificial neural network (ANN), and the separate quantification of the analytes over a range of 0.1–1 mM each was performed without any pretreatment. In all cases, the correlation coefficients obtained were higher than 0.99 and the mean prediction error was less than 1.7%. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号