共查询到20条相似文献,搜索用时 15 毫秒
1.
Reverse flow injection spectrophotometric determination of iron(III) using chlortetracycline reagent
Ruengsitagoon W 《Talanta》2008,74(5):1236-1241
A simple reversed flow injection colourimetric procedure for determining iron(III) was proposed. It is based on the reaction between iron(III) with chlortetracycline, resulting in an intense yellow complex with a suitable absorption at 435 nm. A 200 μl chlortetracycline reagent solution was injected into the phosphate buffer stream (flow rate 2.0 ml min−1) which was then merged with iron(III) standard or sample in dilute nitric acid stream (flow rate 1.5 ml min−1). Optimum conditions for determining iron(III) were investigated by univariate method. Under the optimum conditions, a linear calibration graph was obtained over the range 0.5–20.0 μg ml−1. The detection limit (3σ) and the quantification limit (10σ) were 0.10 and 0.82 μg ml−1, respectively. The relatives standard deviation of the proposed method calculated from 12 replicate injections of 2.0 and 10.0 μg ml−1 iron(III) were 0.43 and 0.59%, respectively. The sample throughput was 60 h−1. The proposed method has been satisfactorily applied to the determination of iron(III) in natural waters. 相似文献
2.
A new flow injection procedure for an assay of Fe(III) by using salicylate obtained from antipyretic powder, which is a cheap and easily available reagent, is proposed. A red complex was continuously monitored by a laboratory-made green LED colorimeter. A linear calibration was obtained in the range of 1–20 mg Fe l−1 with a detection limit of 0.5 mg Fe l−1 and R.S.D.s of 1.4–5.4% (n=3, for 1–20 mg Fe l−1). The new procedure was applied to assay iron contents in pharmaceutical preparations. The results were in good agreement with those of the USP standard method. 相似文献
3.
Green analytical methods employing flow analysis with simple natural reagent extracts have been exploited. Various formats of flow based analysis systems including a single line FIA, a simple lab on chip with webcam camera detector, and a newly developed simple lab on chip system with reflective absorption detection and the simple extracts from some available local plants including butterfly pea flower, orchid flower, and beet root were investigated and shown to be useful as alternative self indicator reagents for acidity assay. Various tea drinks were explored to be used for chromogenic reagents in iron determination. The benefit of a flow based system, which allows standards and samples to go through the analysis process in exactly the same conditions, makes it possible to employ simple natural extracts with minimal or no pretreatment or purification. The combinations of non-synthetic natural reagents with minimal processed extracts and the low volume requirement flow based systems create some unique green chemical analyses. 相似文献
4.
Iron interference in the spectrophotometric catalytic determination of molybdenum based on the iodide-hydrogen peroxide reaction can be corrected by using sulphosalicylic acid as masking and color-forming reagent. The catalytic influence of iron ions is circumvented to the extent of about 90% and correction of any remaining iron ions is possible by monitoring the colored iron(III)-salicylate complex at 490 nm. In this way, iron is also determined. With the proposed system, molybdenum can be determined in plant and food digests within the 0–100 μg Mo 1−1 range in the presence of up to 25 mg Fe 1−1, at a sampling rate of about 50 determinations h−1. The relative standard deviation of 10 consecutive measurements was estimated as < 2%. Results for samples were comparable with those obtained by graphite furnace atomic absorption spectrometry. In addition, recoveries within the range 94–100% were calculated. 相似文献
5.
In the last decade, significant advances in flow analysis have been reported, namely the extensive use of computer-controlled devices to enhance the autonomy and performance of analysers. In the present work, computer-controlled multi-syringe flow injection systems are proposed to perform the spectrophotometric determination of available iron and boron in soil extracts. The methodologies were based on the formation of ferroin complex (determination of iron) and azomethine-H reaction (determination of boron). Both determinations were performed in manifolds with similar configurations by changing the reagents present in the different syringes. In the determination of iron, elimination of Schlieren effect in the detection system was achieved through the binary sampling approach, where a three-way valve was actuated to intercalate small slugs of sample and reagent, promoting better mixing conditions for solutions with different values of refractive index. In the determination of boron, in-line sample blank measurement was attained by omitting the introduction of reagent through software control, without manifold reconfiguration. Linear calibration curves were established between 0.50 and 10.0 mg Fe l−1 and between 0.20 and 4.0 mg B l−1. No systematic difference was found when soil extracts were analysed by the proposed methodologies and compared to the respective reference procedures. 相似文献
6.
A flow injection analysis (FIA)-background correction method comprising two solid-phase reactors and spectrophotometry for determination of ascorbic acid (AsA) is proposed. A polyethylene mini-column filled with solid iodine (30% m/m suspended on silica gel beads), reactor 1, and other column filled only with silica gel, reactor 2, which are then incorporated in a flow system so that solid iodine reagent in reactor 1 is affected as the sample passes through the column. The sample blank is produced by the oxidation of the AsA by iodine to form dehydroascorbic acid, insensitive to ultraviolet at 267 nm. AsA in samples is determined after injected in reactor 2; the difference in two analytical signal observed is related to amount of AsA. The linear range of the system is up to 50 μg ml−1 with a detection limit of 0.08 μg ml−1, R.S.D. of better than 1.0% and sampling frequency of 110 sample h−1. The method is successfully applied to the determination of AsA in pharmaceuticals and foods. 相似文献
7.
Flow injection (FI) and sequential injection (SI) systems with anodic stripping voltammetric detection have been exploited for simultaneous determination of some metals. A pre-plated mercury film on a glassy carbon disc electrode was used as a working electrode in both systems. The same film can be repeatedly applied for at least 50 analysis cycles, thus reducing the mercury consumption and waste. A single line FI voltammetric system using an acetate buffer as a carrier and an electrolyte solution was employed. An injected standard/sample zone was mixed with the buffer in a mixing coil before entering a flow cell. Metal ions were deposited on the working electrode by applying a potential of −1.1 V vs Ag/AgCl reference electrode. The stripping was performed by anodically scanning potential of working electrode to +0.25 V, resulting a voltammogram. Effects of acetate buffer concentration, flow rate and sample volume were investigated. Under the selected condition, detection limits of 1 μg l−1 for Cd(II), 18 μg l−1 for Cu(II), 2 μg l−1 for Pb(II) and 17 μg l−1 for Zn(II) with precisions of 2–5% (n=11) were obtained. The SI voltammetric system was similar to the FI system and using an acetate buffer as a carrier solution. The SI system was operated by a PC via in-house written software and employing an autotitrator as a syringe pump. Standard/sample was aspirated and the zone was then sent to a flow cell for measurement. Detection limits for Cd(II), Cu(II), Pb(II) and Zn(II) were 6, 3, 10 and 470 μg l−1, respectively. Applications to water samples were demonstrated. A homemade UV-digester was used for removing organic matters in the wastewater samples prior to analysis by the proposed voltammetric systems. 相似文献
8.
近年来,由于含铁水处理剂的广泛应用,水体中铁含量逐渐增高.含铁量高的水在管道内易生长铁细菌,增加水的浑浊度,使水产生特殊的色、嗅、味,易污染衣物、器皿,影响某些工业产品的质量.因此,研究准确快速测定水中铁的分析方法具有重要意义. 相似文献
9.
A flow injection spectrophotometric method has been developed for the determination of dissolved and total amounts of iron in tap and natural water samples. The method for the determination of iron employs a sample acidification step in order to decompose iron hydroxide and iron-complexes into free iron, Fe(III) and Fe(II). The amounts of free iron were detected using a catalytic action of Fe(III) and Fe(II) on the oxidation of N,N-dimethyl-p-phenylenediamine in the presence of hydrogen peroxide. Increase in absorbance of oxidized product was detected spectrophotometrically at 514 nm. The proposed method allows 0.02 and 0.06 μg l−1 of LOD and LOQ, respectively, with relative standard deviation (RSD) below 2%. The accuracy and the precision of the method were evaluated by the analysis of the standard reference material, river water. The developed method was successfully applied to real water samples. 相似文献
10.
A flow injection analysis (FIA) catalytic spectrophotometric method for the determination of dissolved iron in seawater was further developed to yield a more sensitive assay with a low detection limit. The method employs an initial sample acidification step followed by an iron pre-concentration step involving an in-line 8-hydroxy-quinoline (8-HQ) metal-chelating resin column. The copper capacity and elution efficiency, as well as the iron FIA performance of three trace-metal clean resins were compared, resulting in the selection of a clean silica gel support for the 8-HQ ligand. The concentrated sample is eluted from the resin with an acidic carrier and mixed with reagents, initiating an iron-catalyzed, color-forming reaction. Increasing the reaction temperature from 18 to 30 °C doubled the sensitivity; reaction temperature control was necessary to obtain good reproducibility in the field. Reagent blanks were as low as 0.05 nM and a detection limit of 0.016 nM was obtained from three times the S.D. of a 0.06 nM seawater sample repeated six times. A 0.06 nM detection limit was calculated from shipboard experiments where total dissolved iron was determined for 10 different samples from the same station. The instrumental sensitivity and precision evolved to the point where the blank associated with the technique is the major factor influencing its detection limit. 相似文献
11.
Ampan P Lapanantnoppakhun S Sooksamiti P Jakmunee J Kradtap Hartwell S Jayasvati S Christian GD Grudpan K 《Talanta》2002,58(6):1327-1334
Three flow injection (FI) systems were investigated for the determination of trace iron in beer: an FI-in-valve column-flame atomic absorption spectrophotometry (FI-FAAS) system, a spectrophotometric FI system with a column placed at the detection point, and an FI-spectrophotometric system with bead injection (FI-BI). Cationic exchange resin Dowex 50W X8 and iminodiacetate chelating resin, Chelex-100, were employed for the FI-spectrophotometric and FI-FAAS systems, respectively. The FI-in-valve column, packed with the resin, enhances the FAAS performance. The spectrophotometric FI system with a column (packed with Chelex-100) placed at the detection point (in a cell holder of a spectrophotometer) is based on the formation of iron (II)–1,10-phenanthroline complex sorbed onto the resin. No eluent has been found to be suitable. The FI-BI for renewable microcolumn has been proven to be an alternative. The FI-FAAS and FI-BI procedures provide online sample preseparation and preconcentration for the determination of iron in beer. Both are simple, rapid, and economical. The procedures also involve sample preparation (decarbonation and suppression of tannin interference by adding ascorbic acid) and standard addition. The results obtained by FI-FAAS and FI-BI agree with those of AOAC spectrophotometric method. 相似文献
12.
Ceric ammonium nitrate has been used for qualitative analysis of ethanol. It forms an intensely colored unstable complex with alcohol. In this work, a simple flow injection (FI) colorimetric method was developed for the determination of ethanol, based on the reaction of ethanol with ceric ion in acidic medium to produce a red colored product having maximum absorption at 415 nm. Absorbance of this complex could be precisely measured in the FI system. A standard or sample solution was injected into a deionized water donor stream and flowed to a gas diffusion unit, where the ethanol diffused through a gas permeable membrane made of plumbing PTFE tape into an acceptor stream to react with ceric ammonium nitrate in nitric acid. Color intensity of the reddish product was monitored by a laboratory made LED based colorimeter and the signal was recorded on a computer as a peak. Peak height obtained was linearly proportional to the concentration of ethanol originally presented in the injected solution in the range of 0.1-10.0% (v/v) (r2 = 0.9993), with detection limit of 0.03% (v/v). With the use of gas diffusion membrane, most of the interferences could be eliminated. The proposed method was successfully applied for determination of ethanol in some alcoholic beverages, validating by gas chromatographic method. 相似文献
13.
J J Berzas Nevado A Espinosa Mansilla I M Plata F Salinas 《Journal of Chemical Sciences》1987,99(4):223-229
The synthesis, properties and analytical possibilities of 2-oximinodimedone monoguanylhydrazone as spectrophotometric reagent
have been examined. A new method for the determination of iron has been developed in a concentration range varying from 0·2–5·0
ppm of iron; the molar absorptivity is 1·1×104 litres mol−1 cm−1 at 600 nm and the relative error is ±0·3%. The method has been applied satisfactorily to the determination of iron in different
inorganic samples. 相似文献
14.
A reversed flow injection colorimetric procedure for determining iron(III) at the μg level was proposed. It is based on the reaction between iron(III) with norfloxacin (NRF) in 0.07 mol l−1 ammonium sulfate solution, resulting in an intense yellow complex with a suitable absorption at 435 nm. Optimum conditions for determining iron(III) were investigated by univariate method. The method involved injection of a 150 μl of 0.04% w/v colorimetric reagent solution into a merged streams of sample and/or standard solution containing iron(III) and 0.07 mol l−1 ammonium sulfate in sulfuric acid (pH 3.5) solution which was then passed through a single bead string reactor. Subsequently the absorbance as peak height was monitored at 435 nm. Beer's law obeyed over the range of 0.2–1.4 μg ml−1 iron(III). The method has been applied to the determination of total iron in water samples digested with HNO3–H2O2 (1:9 v/v). Detection limit (3σ) was 0.01 μg ml−1 the sample through of 86 h−1 and the coefficient of variation of 1.77% (n=12) for 1 μg ml−1 Fe(III) were achieved with the recovery of the spiked Fe(III) of 92.6–99.8%. 相似文献
15.
A sequential injection lab-on-valve (SI-LOV) system was used to develop a new methodology for the determination of iron in wine samples exploiting the bead injection (BI) concept for solid phase extraction and spectrophotometric measurement. Nitrilotriacetic Acid (NTA) Superflow resin was used to build the bead column of the flow through sensor. The iron (III) ions were retained by the bead column and react with SCN− producing an intense red colour. The change in absorbance was monitored spectrophotometrically on the optosensor at 480 nm. It was possible to achieve a linear range of 0.09-5.0 mg L−1 of iron, with low sample and reagent consumption; 500 μL of sample, 15 μmol of SCN−, and 9 μmol of H2O2, per assay. The proposed method was successfully applied to the determination of iron in wine, with no previous treatment other than dilution, and to other food samples. 相似文献
16.
17.
18.
Cobalt(II) phthalocyanine [Co(II)Pc] is used as both an ionophore and chromogen for batch and flow injection potentiometric and spectrophotometric determination of anionic surfactants (SDS), respectively. The potentiometric technique involves preparation of a polymeric membrane sensor by dispersing [Co(II)Pc] in a plasticized PVC membrane. Under batch mode of operation, the sensor displays a near-Nernstian slope of −56.5 mV decade−1, wide response linear range of 7.8 × 10−4 to 8.0 × 10−7 mol L−1, lower detection limit of 2.5 × 10−7 mol L−1 and exhibits high selectivity for anionic surfactants in the presence of many common ions. Under hydrodynamic mode of operation (FIA), the slope of the calibration plot, limit of detection, and working linear range are −51.1 mV decade−1, 5.6 × 10−7 and 1.0 × 10−3 to 1.0 × 10−6 mol L−1, respectively. The spectrophotometric method is based on the use of [Co(II)Pc] solution in dimethylsulfoxide (DMSO) as a chromogenic reagent. The maximum absorption of the reagent at 658 nm linearly decreases with the increase of anionic surfactant over the concentration range 2-30 μg mL−1. The lower limit of detection is 1 μg mL−1 and high concentrations of many interfering ions are tolerated. Flow injection spectrophotometric measurements are carried out by injection of the surfactant test solution in a stream of the reagent in DMSO. The sample throughput, working range and lower detection limit are 25-30 samples h−1, 4-60 and 2 μg mL−1, respectively. The potentiometric and spectrophotometric techniques are applied to the batch and flow injection measurements of anionic surfactants in some commercial detergent products. The results agree fairly well with data obtained using the standard methylene blue spectrophotometric method. 相似文献
19.
在NaOH-NaHCO3介质中,铁氰化钾氧化西咪替丁产生快速化学发光反应,0.5 s后发光达到最大,2 s后迅速衰减至零。本文结合流动注射技术,建立了一种化学发光测定西咪替丁的新方法。针对这一快速发光反应,设计了与之相应的管路系统和最短的反应管道来捕捉最大化学发光信号,发光强度与西咪替丁质量浓度在5×10-7~1×10-4g/mL范围内呈线性关系,检出限为1.1×10-7g/mL。对5×10-6g/mL西咪替丁进行11次平行测定,相对标准偏差为1.8%。本法已用于西咪替丁片剂的测定。 相似文献
20.
An automatic reagentless photometric procedure for the determination of ethanol in red wine is described. The procedure was
based on a falling drop system that was implemented by employing a flow injection analysis manifold. The detection system
comprised an infrared LED and a phototransistor. The experimental arrangement was designed to ensure that the wine drop grew
between these devices, thus causing a decrease in the intensity of the radiation beam coming from the LED. Since ethanol content
affected the size of the wine drop this feature was exploited to develop an analytical procedure for the photometric determination
of ethanol in red wine without using a chromogenic reagent. In an attempt to prove the usefulness of the proposed procedure,
a set of red wines were analysed. No significant difference between our results and those obtained with a reference method
was observed at the 95% confidence level. Other advantages of our method were a linear response ranging from 0.17 up to 5.14 mol L−1 (1.0 up to 30.0%) ethanol (R=0.999); a limit of detection of 0.05 mol L−1 (0.3%) ethanol; a relative standard deviation of 2.5% (n=10) using typical wine sample containing 2.14 mol L−1 (12.5%) ethanol; and a sampling rate of 50 determinations per hour. 相似文献