首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Various analytical methods used in the analysis of type B trichothecenes (deoxynivalenol, nivalenol, 3- and 15-acetyldeoxynivalenol) in cereals were compared and optimised in this work. These methods use either GC-electron-capture detection (ECD) of trimethylsilyl, trifluoroacetyl and heptafluorobutyryl derivatives or HPLC with UV or photodiode array detection of analytes. A new HPLC procedure using fluorescence detection prior derivatisation with coumarin-3-carbonyl chloride has been also tested. Five extraction solvents and two solid-phase extraction cartridges (silica, Florisil) plus a especial clean-up column (MycoSep 225) were compared in order to obtain the best recovery of the mycotoxins with minimal presence of coextractives in the chromatograms. The chosen extraction solvent was a mixture of acetonitrile-water (84:16, v/v). The MycoSep 225 column was chosen as the best alternative for clean-up of grain samples. For GC-ECD analysis, derivatisation of analytes with heptafluorobutyric anhydride prior the final determination was chosen as the most suitable procedure. HPLC-photodiode array (at 221 nm) analysis was more suitable for determination of type B trichothecenes than HPLC of the fluorescent coumarin-3-carbonyl derivatives. Recoveries obtained in spiked corn, rice and wheat are reported. The utility of the proposed methodology was assayed in cereal cultures of various Fusarium strains.  相似文献   

2.
A liquid chromatographic (LC) method was developed for determining deoxynivalenol (DON) in whole wheat flour and wheat bran. A 15 g test sample was extracted with acetonitrile-water (84 + 16, v/v) and applied to a Romer MycoSep cleanup column. The eluate was dried and then reconstituted in a 0.1 M phosphate buffer, pH 7.0, and applied to a Vicam DONtest-LC cleanup column. The methanol eluate was chromatographed with a methanol-water (17 + 83, v/v) mobile phase on a C18 column with UV detection at 220 nm. Five replicates at each of 5 fortification levels (0.25, 0.50, 1.0, 2.0, and 4.0 ppm), plus 5 controls, were determined for both whole wheat flour and wheat bran. For flour, the average recoveries were 72.2-91.5% with relative standard deviations (RSDs) of 4.9-18.4%. The intra-assay flour recovery was 82.4% with 9.8% RSD. A 5 replicate sample of naturally incurred wheat had an average of 1.1 ppm DON with 6.7% RSD. For bran, average recoveries of fortified samples were 69.5-99.7% with RSDs of 1.7-18.8%. The intra-assay bran recovery was 81.5% with 8.9% RSD. The limit of detection (about 3x noise) for the method is 0.05 ppm; the correlation coefficient (linearity) was >0.9995. The DON peak was clearly identified and easily integrated in the chromatograms.  相似文献   

3.
Fabiani A  Corzani C  Arfelli G 《Talanta》2010,83(1):281-285
Three different clean-up methods and two analytical techniques were compared to determine Ochratoxin A (OTA) in wines. The first clean-up used a MycoSep column, the second an immunoaffinity column (IAC) and the third consisted in a liquid-liquid extraction (LLE) using dichloromethane in acid conditions. Meanwhile, two different OTA determination techniques were also evaluated: a HPLC analysis using a fluorescence detector and an enzyme-linked immunosorbent assays (ELISA) method.Correlations between clean-up methods and analytical techniques to determine OTA in wine were made evaluating linearity, accuracy and precision.Both the two first clean-up methods (solid-phase extraction, SPE) showed a good linear fit (r2 = about 0.9999), followed by LLE. The use of immunoaffinity columns showed the best recoveries, even if also the SPE with MycoSep showed good recoveries while the LLE recoveries were the worst ones. The HPLC analysis showed good precision and accuracy, while ELISA method, even with a sufficient linearity, generally underestimated OTA content in wines.  相似文献   

4.
Three different clean-up methods for the analysis of deoxynivalenol in cereals and cereal-based foods are described and compared. DON was extracted with water or acetonitrile/water (84/16, v/v) and the extracts were cleaned-up by passing either through two different immunoaffinity columns (DONtest, Vicam; DONPrep, Rhone) or a charcoal/alumina column (MycoSep, Romer Labs). Determinative analysis was performed by high performance liquid chromatography (HPLC) with diode array detection (DAD) and fluorescenic detection (FLD) after post-column derivatisation. Different parameters were optimised and possible reasons for diverse results are discussed. The final method was validated and adopted to different matrices. Best results were obtained using immunoaffinity columns for clean-up in combination with HPLC-FLD detection of the DON-derivative.  相似文献   

5.
Solid-phase extraction of soy isoflavones   总被引:3,自引:0,他引:3  
An automated method using solid-phase extraction (SPE) for the concentration and clean-up of soy isoflavone extracts is proposed in this work. Using a standardized sample (0.1 g of a freeze dried soybean extract/25 mL of water); eight SPE cartridges with a wide range of sorbents (C18, divinylbenzene and modified divinylbenzene) from different suppliers were evaluated and compared. A large variation on SPE cartridges performance was observed, especially regarding retention and breakthrough volume of isoflavones during sample load and washing steps. The most effective cartridges were the divinylbenzene based cartridges, especially Strata X (from Phenomenex) and HLB oasis (from Waters). Using Strata X cartridges, several extraction parameters, such as sample loading flow (5-15 mL min(-1)), extracting solvent volume (2-6 mL of methanol), pH of the extracting solvent and the necessity of drying the sorbent before elution, were evaluated to provide a fast, specific, quantitative and reproducible SPE method. The optimized method consists of conditioning the cartridge with 10 mL of methanol and 10 mL of water (10 mL min(-1)), loading 25 mL of the standardized extract onto the cartridges (5 mL min(-1)), washing the cartridge with 10 mL of water (10 mL min(-1)) and finally eluting with 4 mL of methanol (10 mL min(-1)). Mean isoflavones recovery was 99.37% and mean intra- and inter-day reproducibility was higher than 98%. The developed sample clean-up/concentration (6.25:1) method takes less than 10 min and can be used in the analysis of isoflavones from soy extracts.  相似文献   

6.
A method for the simultaneous LC-fluorescence detection (FLD) determination of eight trichothecenes A and B by pre-column derivatization with coumarin-3-carbonyl chloride, a highly fluorescent fluorophore, has been developed. The reaction conditions (temperature, reaction time, reactant ratios) were optimized to give a reproducible quantitative conversion. All derivatives were characterized by LC-MS. The chromatographic parameters were optimized (column, eluent) to give a very good separation of three type A (diacetoxyscirpenol, T-2 toxin, HT-2 toxin) and five type B trichothecenes [deoxynivalenol (DON), nivalenol, fusarenon-X, 3-acetyldeoxynivalenol, 15-acetyldeoxynivalenol]. The best conditions were obtained on a narrow-bore C18 column with a water-methanol gradient. The detection limits (S/N = 3:1) in grain samples, with an injected volume of 5 microl, were 0.2-1 ng/g for all trichothecenes. These values are more than one order of magnitude lower than those of other LC-FLD and LC-MS methods and are similar to those obtained by GC-MS. The calibration curves were linear between 100 and 2500 ng/g. The method was successfully applied to the analysis of a certified wheat reference material, after solvent extraction and clean-up on a Mycosep column, obtaining a good recovery (89% for DON) and a high accuracy (z-score value: 0.67).  相似文献   

7.
Two detection methods are described for the determination of dexamethasone in feed, which may be used as screening and confirmatory methods. The procedures were developed after studying different extraction and clean-up procedures: feed extraction was optimized using methylene chloride and hexane followed by a tandem solid-phase clean-up step with silica and C18 cartridges. The confirmatory method presented is based on normal-phase high-performance liquid chromatography on a Diol 5 microns column, with hexane-propan-2-ol (90:10 v/v) as mobile phase, followed by diode array detection and confirmation. All parameters are discussed, especially the extraction and clean-up steps. Recovery studies after application of the proposed method to different kinds of feed samples spiked with dexamethasone at levels between 120 and 1600 ng g-1 yielded a mean value of 55.4% with an overall standard deviation of 15.6%. The proposed procedure allows the determination of dexamethasone in feed at levels lower than 50 ng g-1.  相似文献   

8.
A sensitive and robust liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous determination of aflatoxins (B(1), B(2), G(1), G(2)), ochratoxin A, deoxynivalenol, zearalenone, T-2 and HT-2 toxins in cereal-based foods. Samples were extracted with a mixture of acetonitrile/water (84:16, v/v) and cleaned up through a polymeric solid-phase extraction column. Detection and quantification of the nine mycotoxins were performed by reversed-phase liquid chromatography coupled with electrospray ionization triple quadrupole mass spectrometry (LC/ESI-MS/MS), using fully (13)C-isotope-labelled mycotoxins as internal standards. The method was validated in-house for five different cereal processed products, namely barley, oat and durum wheat flours, rye- and wheat-based crisp bread. Recoveries and repeatability of the whole analytical procedure were evaluated at contamination levels encompassing the EU maximum permitted levels for each tested mycotoxin. Recoveries ranged from 89 to 108% for deoxynivalenol, from 73 to 114% for aflatoxins, from 85 to 114% for T-2 and HT-2 toxins, from 64 to 97% for zearalenone, from 74 to 102% for ochratoxin A. Relative standard deviations were less than 16% for all tested mycotoxins and matrices. Limits of detection (signal-to-noise ratio 3:1) ranged from 0.1 to 59.2 μg/kg. The trueness of the results obtained by the proposed method was demonstrated by analysis of reference materials for aflatoxins, deoxynivalenol, zearalenone. The use of inexpensive clean-up cartridges and the increasing availability of less expensive LC/MS/MS instrumentation strengthen the potential of the proposed method for its effective application for reliable routine analysis to assess compliance of tested cereal products with current regulation.  相似文献   

9.
The feasibility of different clean-up procedures was studied for the determination of polycyclic aromatic hydrocarbons (PAHs) in biota samples such as oysters, mussels and fish liver. In this sense, once the samples were extracted--essentially with acetone and in a microwave system--and before they could be analysed by gas chromatography-mass spectrometry (GC-MS), three different approaches were studied for the clean-up step: solid phase extraction (SPE), microwave-assisted saponification (MAS) and gel permeation chromatography (GPC). The main aim of this work was to maximise the recoveries of PAHs and to minimise the presence of interfering compounds in the last extract. In the case of SPE, Florisil cartridges of 1, 2 and 5 g, and silica cartridges of 5 g were studied. In that case, and with oysters and mussels, microwave-assisted extraction and 5 g Florisil cartridges provided good results. In addition, the concentrations obtained for Standard Reference Material (SRM) NIST 2977 (mussel tissue) were in good agreement with the certified values. In the case of microwave-assisted saponification, the extracts were not as clean as those obtained with 5 g Florisil and this fact lead to overestimate the concentration of the heaviest PAHs. Finally, the cleanest extracts were obtained by GPC. The method was successfully applied to mussels, oysters and hake liver, and the results obtained for NIST 2977 (mussel tissue) were within the confidence interval of the certified reference material for most of the certified analytes.  相似文献   

10.
A sensitive and reliable liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method has been developed to determine, in a single run, eight trichothecenes, three fumonisins, zearalenone and alpha-zearalenol, in corn meal samples. LC and MS conditions were varied to find the best compromise in terms of sensitivity and separation. An acceptable compromise was obtained using a C18 column thermostatted at 45 degrees C and a mobile phase gradient of methanol/water with 10 mmol/L formate buffer (pH 3.8). A multiple reaction monitoring program, in which fumonisins and trichothecenes (except nivalenol and deoxynivalenol) are acquired in positive ESI as [M+H]+ or [M+NH4]+, and all other compounds in negative ESI, was developed to match appropriate retention time windows. Sample preparation used a simple homogenization of the corn meal sample with acetonitrile/water (75:25, v/v) followed by extraction on a C18 cartridge and clean-up on a cartridge containing graphitized carbon black. Method detection limits were in the range 2-14 ng/g, with the exception of nivalenol (27 ng/g), deoxynivalenol (40 ng/g) and 15-acetyldeoxynivalenol (30 ng/g). Good accuracy (recoveries 81-104%) and precision (RSD 4-11%) were obtained by performing calibration using a spiked analyte-free extract.  相似文献   

11.
A new, simple and selective method for the analysis of 5-hydroxymethylfurfural (HMF) in foods by gas chromatography coupled to mass spectrometry (GC-MS) is proposed. Several derivatising procedures based on the formation of an HMF silylated derivative using different reagents were studied. Among the derivatising reagents examined, N,O-bis-trimethylsilyltrifluoroacetamide (BSTFA) provided the best derivatisation yield. Sample clean-up was also optimised, using either liquid-liquid extraction with dichloromethane or solid-phase extraction (SPE) with several commercially available cartridges, and the best results were obtained using ENV+ cartridges. Quality parameters such as day-to-day and run-to-run precision (RSD<10%), linearity (between 25 and 700 ng g(-1)) and detection limit (6 ng g(-1)) were established. This method was successfully applied to the analysis of HMF content in several Spanish food samples from a local market, such as jam, honey, orange juice and bakery products.  相似文献   

12.
Doong RA  Lee CY 《The Analyst》1999,124(9):1287-1289
Fourteen organochlorine pesticide residues in fatty foods were determined using a simple and rapid procedure based on solid-phase extraction (SPE) clean-up cartridges with octadecyl (C18)-bonded porous silica, a tandem C18 and Florisil column, Alumina-N and Florisil. A Florisil cartridge eluted with 12 ml petroleum ether-ethyl ether (95 + 5) was the most efficient clean-up procedure capable of eliminating the matrix interference and satisfying the agreed acceptable recovery for the large numbers of organochlorine pesticides in nine kinds of foods having different fat contents. Average recoveries of organochlorine pesticides in shellfish, fish and meats ranged from 77 to 105%, 84 to 98% and 85 to 107%, respectively. In addition, analysis of a certified Standard Reference Material (SRM 1945) verified the satisfactory performance of Florisil clean-up cartridge. This SPE method not only yielded comparable results for nonfatty foods, but also provided a reliable separation and quantification of organochlorine pesticides for analyzing a large number of foods with a wide range of fat content.  相似文献   

13.
A commercially available Argonaut VacMaster-96 plate-to-plate solid-phase extraction (SPE) station equipped with 24 FluoroFlash cartridges is employed for parallel purification of fluorous reaction mixtures. Each cartridge charged with 3 g of fluorous silica gel has the capability to produce up to 100 mg of purified small molecules. The 24-well receiving plate has a standard footprint that can be directly concentrated in a Genevac vacuum centrifuge. Important issues such as sample loading, product cross-contamination, cartridge reuse, and reproducibility are investigated. The SPE system has been demonstrated in the purification of three small libraries that were produced involving amine scavenging reactions with fluorous isatoic anhydride, amide coupling reactions with 2-chloro-4,6-bis[(perfluorohexyl)propyloxy]-1,3,5-triazine (fluorous CDMT), and amide coupling reactions with a newly developed fluorous Mukaiyama condensation reagent.  相似文献   

14.
Three extraction methodologies (Soxhlet, ultrasonic and pressurized liquid extraction) and several clean-up procedures (Florisil, silica and alumina in cartridges or glass column format) were tested and compared to extract 16 US Environmental Protection Agency (EPA) polycyclic aromatic hydrocarbons (PAHs) from Pinus pinea L. needles. Quantification was done by gas chromatography with mass spectrometry, by internal standard method using five deuterated PAH surrogate standards. Among the several extraction and clean-up procedures tested, ultrasonic extraction followed by alumina cartridge clean-up was the preferred method, yielding recoveries between 72 and 100% and limits of detection between 0.22 and 0.71 ng/g dry weight. The performance of the method was tested to determine PAHs in naturally contaminated samples.  相似文献   

15.
A new approach is presented for the determination of avoparcin in tissue. Complete recovery from spiked swine kidney was achieved with hot water modified with 30% ethanol (v/v). The samples were extracted at 75 degrees C and 50 atm by accelerated solvent extraction. In situ sample clean-up was achieved by using matrix solid-phase dispersion utilizing the acrylic polymer XAD-7 HP, and by adding triethylammonium phosphate (TEAP) to the extraction solvent. The aqueous extracts were concentrated by solid-phase extraction (SPE) on the hydrophilic interaction chromatography (HILIC) material polyhydroxyethyl aspartamide. Complete analyte retention was possible during SPE when the kidney extracts were modified with 70% ethanol. A 200 A, 5 microm HILIC column with UV225 detection was used for the separation of avoparcin. The retention time was less than 15 min with 47% aqueous component in acetonitrile and 15 mM TEAP as eluent. The average recovery of avoparcin from kidney samples was 108%.  相似文献   

16.
《Analytical letters》2012,45(16):2496-2504
A liquid chromatography method was developed for the determination of neomycin in swine tissues. Sample clean-up was especially focused on in this research. After neomycin was extracted from tissue with 10% trichloroacetic acid (w/v) solution, several clean-up procedures using MCX, CBA, WCX, and C18 solid-phase extraction (SPE) columns were compared for the purification effects and recoveries. The best result was obtained using MCX SPE column. The purified extract was derivatized with 9-fluorenylmethyl chloroformate and then separated on a C18 column and detected by a fluorescence detector. The spiked recoveries at 0.2–10 mg/kg ranged from 80.8–95.3% with coefficient of variations less than 12.1%.  相似文献   

17.
固相萃取-气相色谱法测定茶叶中残留的92种农药   总被引:13,自引:5,他引:8  
建立了茶叶中92种农药多残留的气相色谱分析方法。茶叶样品用乙腈一次性提取后,有机磷类农药经Envi-Carb固相小柱净化,用10 mL乙腈-甲苯(体积比为3∶1)洗脱剂淋洗,气相色谱-火焰光度检测器(GC-FPD)检测;有机氯类和拟除虫菊酯类农药经串联Envi-Carb和NH2固相小柱净化,用5 mL乙腈-甲苯(体积比为3∶1)洗脱剂淋洗,GC-电子捕获检测器(ECD)检测。采用外标法定量。添加回收试验的结果表明:92种农药的平均回收率为80.3%~117.1%,相对标准偏差为1.5%~9.8%。方法的检出限为0.0025~0.10 mg/kg。该方法的灵敏度、准确度和精密度均符合农药残留测定的技术要求。  相似文献   

18.
A solid-phase extraction (SPE) method for sample clean-up followed by a reversed-phase high-performance liquid chromatography (HPLC) procedure for the assay of five antidepressant drugs (trazodone, doxepin, desipramine, maprotiline and imipramine) is reported. The drugs were recovered from plasma buffered at a suitable pH using C18 Bond-Elut cartridges and mixtures of methanol-aqueous buffer as washing and elution solvents. The recoveries of the drugs using other sorbent materials (C8, C2, cyclohexyl, cyanopropyl and phenyl Bond Elut and copolymer HLB waters cartridges) were also examined. The selectivity of SPE was examined by using spiked plasma samples and the CH cartridge gave rise to the cleanest extracts. Cyclohexyl cartridges were conditioned successively with 2 ml of methanol and 1 ml of acetic acid-sodium acetate buffer (0.1 M, pH 4.0). Plasma sample was buffered at pH 4.0 and then applied to the sorbent. The washing step was performed subsequently with 1.5 ml of acetate buffer (0.1 M, pH 4.0), 100 microl of acetonitrile and 1 ml of methanol-acetate buffer (30:70, v/v). Finally, the analytes were eluted with 0.5 ml of methanol-acetate buffer (70:30, v/v). The extract was evaporated to dryness, reconstituted in mobile phase, and chromatographed on a reversed-phase C18 column with ultraviolet detection at 215 nm. The recoveries of trazodone, doxepin, desipramine, maprotiline and imipramine from spiked plasma samples using the CH cartridge were 58 2, 84 3, 83 3, 83 3 and 82 2%, respectively. The within-day and between-day repeatabilities were lower than 6% and 9%, respectively. The linearity of calibrations for the five antidepressants was between 0.005 and 2 microg/ml. The limits of detection were 1 ng/ml for trazodone, doxepin and desipramine and 2 ng/ml for maprotiline and imipramine.  相似文献   

19.
Ochratoxin A (OTA) is a mycotoxin produced by some species of Aspergillus and Penicillium verrucosum. It has been found in foods and feed all over the world. There is a great concern about OTA because it is nephrotoxic and probably, carcinogenic to humans. Most of analytical methods developed for OTA in wine, beer and other products are based on LC with fluorescence detection (LC-FLD). In the present work, various procedures for extraction and/or clean-up for determination of OTA in musts, wine and beer by LC-FLD were compared: (1) dilution with polyethylen glycol 8000 and NaHCO3 solution and clean-up an on immunoaffinity column (IAC); (2) extraction with chloroform and IAC clean-up; solid-phase extraction (SPE) on (3) reversed-phase (RP) C18; (4) RP phenylsilane and (5) Oasis HLB cartridges. SPE on phenylsilane and Oasis HLB have not been reported for OTA analysis in beverages. The same LC-FLD conditions and concentration ratio were used. The former procedure was simple, rapid and provided flat baselines, free from most impurity peaks, high OTA recoveries and quite repeatable results. RP C18 using methanol-acetic acid (99.5:0.5) as elution solvent provided good recoveries and precision, thus becoming a cheaper but interesting alternative at 0.1-1 ng/ml spiking levels. Oasis HLB cartridges were usually better than phenylsilane. Possible binding of OTA to proteins or other components was tested by acid treatment before extraction but no significant differences with controls appeared.  相似文献   

20.
杨秋红  杨移斌  胥宁  刘永涛  董靖  艾晓辉 《色谱》2017,35(8):881-885
建立了气相色谱-脉冲火焰光度法(GC-PFPD)测定水产品中二硫氰基甲烷(MBT)残留的分析方法。用二氯甲烷-正己烷溶液(1∶1,v/v)在超声条件下提取水产品中的MBT,然后用中性氧化铝固相萃取小柱对提取物进行净化和富集,通过HP-5MS石英毛细管柱(30 m×0.32 mm×0.25μm)分离,最后采用配有脉冲火焰光度检测器的气相色谱仪进行测定,外标法定量。MBT在1.0~20.0 mg/L范围内线性关系良好,相关系数为0.997 1;检出限为0.1 mg/kg;加标回收率为65.6%~97.6%,精密度为6.32%~12.8%(n=7)。该法能很好地满足水产品中药物残留检测的需求。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号