首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
Xiao-Qing Zhao 《Talanta》2009,80(1):242-385
A rapid and sensitive flow injection fluorometry has been developed for the determination of formaldehyde based on the microwave on-line accelerating its Hantzsch reaction with cyclohexane-1,3-dione. Under the optimized conditions, the fluorescent intensity is proportional to formaldehyde content in the range from 0.05 ng/mL to 2.000 μg/mL. The detection limit (S/N = 3) is 0.02 ng/mL and the analytical frequency is 28 injections per hour. The relative standard deviations are 2.2% and 3.1% for eleven injections of 0.100 and 0.001 μg/mL of formaldehyde, respectively. With the assistance of microwave irradiation, a best sensitive fluorometry was established for the determination of formaldehyde at a high analytical frequency. This method was successfully applied to food analysis without requiring any sample pretreatment, and the determination results were correlated well with those obtained by the standard method with a sample pretreatment of steam distillation.  相似文献   

2.
We developed a rapid identification and quantification method for the toxicological analysis of methamphetamine and amphetamine in human hair by gas chromatography/mass spectrometry coupled with a novel combination of micropulverized extraction, aqueous acetylation and microextraction by packed sorbent (MEPS) named MiAMi–GC/MS. A washed hair sample (1–5 mg) was micropulverized for 5 min in a 2 mL plastic tube with 250 μL of water. An anion-exchange sorbent was added to adsorb anionic interferences. After removing the residue with a membrane-filter unit, sodium carbonate and acetic anhydride was admixed in turn. Acetylation was completed in approximately 20 min at room temperature. The acetylated analytes in the reaction liquid were concentrated to an octadecylsilica sorbent packed in the needle of a syringe by a CombiPAL autosampler. Elution was carried out with 50 μL of methanol, and the entire eluate injected into a gas chromatograph using a programmable temperature vaporizing (PTV) technique. The time required for sample preparation and GC/MS analysis was approximately 1 h from a washed hair sample, and an evaporation process was not required. Ranges for quantification were 0.20–50 (ng/mg) each for methamphetamine and amphetamine using 1 mg of hair. Accuracy and relative standard deviation (RSD) were evaluated intraday and interday at three concentrations, and the results were within the limit of a guidance issued by U.S. Food and Drug Administration. For identification, full-scan mass spectra of methamphetamine and amphetamine were obtained using 5 mg of fortified hair samples at 0.2 ng/mg. The extraction device of MEPS was durable for at least 300 extractions, whereas the liner of the gas chromatograph should be replaced after 20–30 times use. The carry over was estimated to be about 1–2%. This sample-preparation method coupled with GC/MS is fast and labor-saving in comparison with conventional methods.  相似文献   

3.
CdSe quantum dots as luminescent probes for spironolactone determination   总被引:1,自引:0,他引:1  
Liang J  Huang S  Zeng D  He Z  Ji X  Ai X  Yang H 《Talanta》2006,69(1):126-130
Based on the quenching of the fluorescence of CdSe quantum dots (QDs) by spironolactone, a simple, rapid and specific method for spironolactone determination was proposed. In the optimum conditions, spironolactone concentration versus quantum dot fluorescence gave a linear response with an excellent 0.997 correlation coefficient, between 2.5 and 700 mg/mL (6.0-1680 μmol/L) and the limit of detection (S/N = 3) was 0.2 μg/mL (0.48 μmol/L). The contents of spironolactone in pharmaceutical tablets were determined by the proposed method and the results agreed with the claimed values. The possible mechanism for the reaction was also discussed.  相似文献   

4.
A multiresidue method is described for simultaneous estimation of 83 pesticides and 12 dioxin-like polychlorinated biphenyls (PCBs) in red and white wines. The samples (20 mL wine, acidified with 20 mL 1% HCl) were extracted with 10 mL ethyl acetate (+20 g sodium sulphate) and cleaned by dispersive solid-phase extraction (DSPE) with anhydrous calcium chloride and Florisil successively. The final extract (5 mL) was solvent exchanged to 1 mL of cyclohexane:ethyl acetate (9:1), further cleaned by DSPE with 25 mg primary secondary amine sorbent and analyzed by gas chromatography–time-of-flight mass spectrometry (GC–TOF-MS) within 31 min run time. The limits of quantification of most analytes were ≤10–20 μg/L. Acidification of wine prior to extraction prevented hydrolysis of organophosphorous pesticides as well as dicofol, whereas treatment with CaCl2 minimized the fatty acid co-extractives significantly. Solvent exchange to cyclohexane:ethyl acetate (9:1) further minimized the co-extractives. Recoveries at 5, 10 and 20 ng/mL were >80% for most analytes except cyprodinil, buprofezin and iprodione. The expanded uncertainties at 10 ng/mL were <20% for most analytes. Intra-laboratory precision in terms of Horwitz ratio of all the analytes was below 0.5, suggesting ruggedness of the method. Effectively, the method detection limit for most analytes was as low as up to 1 ng/mL in both red and white wine, except for cyfluthrin and cypermethrin.  相似文献   

5.
The isolation of the retinal isomers from all-trans-retinal was performed by flash countercurrent chromatography. In each separation, isomerization reaction solution of 200 mg all-trans-retinal could be loaded on a 1200 mL of high-speed countercurrent chromatographic column with 5 mm bore, eluted by a mobile phase flow rate of 25 mL/min, resulting in 63 mg of 11-cis-retinal, 24 mg of 13-cis-retinal and 26 mg of 9-cis-retinal with purities more than 95%. n-Hexane–acetonitrile (3:1) was used as the solvent system which possesses the advantages of simplicity, re-use of the solvent and multiple injections. This method could be used to prepare 13-cis-retinal, 11-cis-retinal and 9-cis-retinal for the photoisomerization investigation, such as the effect of 11-cis-retinal in the visual system.  相似文献   

6.
A rapid and sensitive method has been developed for the simultaneous detection of cyromazine and melamine in chicken eggs using the quick, easy, cheap, effective, rugged and safe (QuEChERS) method coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS). The optimal extraction solvent for the liquid–liquid extraction was 5 mL of acetonitrile with a 0.1 M hydrochloric acid aqueous solution (99.5:0.5, v/v). The extract was cleaned with 0.5 g of anhydrous magnesium sulfate and 10 mg of graphitized carbon black. The analysis of cyromazine and melamine was accomplished by combining the use of an anion exchange LC column with tandem mass spectrometry in the positive electrospray ionization mode with selected reaction monitoring mode (SRM). The detection limits were 1.6 ng g−1 for cyromazine and 8 ng g−1 for melamine, and the quantitation limits were 5.5 ng g−1 for cyromazine and 25 ng g−1 for melamine. The recoveries of cyromazine and melamine in the spiked egg samples were 83.2% and 104.6%, respectively, with an relative standard deviation (RSD) of less than 18.1%. The intra-day and inter-day precisions, represented by the RSD, ranged from 1.5% to 8.8% and 6.8% to 14.3%, respectively. The proposed method was tested by analyzing chicken eggs from the markets and from the veterinary medicine laboratory. The concentrations of cyromazine and melamine detected in these samples were in the range of 20–94 ng g−1. The results demonstrated that the QuEChERS method combined with LC–MS/MS is a simple, rapid and inexpensive method for the analysis of cyromazine and melamine in eggs.  相似文献   

7.
The feasibility of microwave-accelerated derivatization for capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was evaluated. The derivatization reaction was performed in a domestic microwave oven. Histidine (His), 1-methylhistidine (1-MH) and 3-methylhistidine (3-MH) were selected as test analytes and fluorescein isothiocyanate (FITC) was chosen as a fluorescent derivatizing reagent. Parameters that may affect the derivatization reaction and/or subsequent CE separation were systematically investigated. Under optimized conditions, the microwave-accelerated derivatization reaction was successfully completed within 150 s, compared to 4-24 h in a conventional water-bath derivatization process. This will remarkably reduce the overall analysis time and increase sample throughput of CE-LIF. The detection limits of this method were found to be 0.023 ng/mL for His, 0.023 ng/mL for 1-MH, and 0.034 ng/mL for 3-MH, respectively, comparable to those obtained using traditional derivatization protocols. The proposed method was characterized in terms of precision, linearity, accuracy and successfully applied for rapid and sensitive determination of these analytes in human urine.  相似文献   

8.
A simplified, easily performed persulfate digestion method has been developed to process a large number of water samples for routine determination of total dissolved phosphorus. A neutral potassium persulfate solution (5%, w/v, pH ∼6.5) is added to the samples (at 10 mg potassium persulfate per mL of sample), which are then digested at 90 °C in an oven for 16 h. This method does not require pH adjustment after digestion because neither an acid nor a base is added to the samples prior to digestion. The full color of phosphoantimonylmolybdenum blue from the digested samples develops within 8 min. Compared with the autoclave method, digestion at sub-boiling temperatures in an oven is safer, and a large number of samples can be heated overnight requiring no constant monitoring. The apparent molar absorptivity (?) of nine organic phosphorus compounds and two condensed inorganic phosphates ranged from 1.17 × 104 to 1.82 × 104 L mol−1 cm−1 in both distilled water and artificial seawater matrixes. The average recovery of these phosphorus compounds was 94 ± 11% for the DIW matrix and 90 ± 12% for the ASW matrix. No significant difference in molar absorptivity was observed between the undigested and digested phosphate, especially in the seawater matrix. It is, therefore, suggested that a phosphate solution be directly employed without digestion as the calibration standard for routine determination of total dissolved phosphorus. This method was used to study the spatial distribution of total dissolved phosphorus in the surface waters of Florida Bay.  相似文献   

9.
A new simple, sensitive and selective liquid chromatography coupled with mass spectrometry (LC/MS) method for quantification of captopril after precolumn derivatization with p-bromo-phenacyl-bromide in human plasma was validated. Plasma samples were analysed on a monolithic column (Cromolith Performance-RP 18e, 100 mm × 4.6 mm I.D., 3 μm) under isocratic conditions using a mobile phase of a 40:60 (v/v) mixture of acetonitrile and 0.1% (v/v) formic acid in water. The flow rate was 1 mL/min at the column temperature of 30 °C. In these chromatographic conditions, the retention time was 4.4 min for captopril derivative. The detection of the analyte was in MRM mode using an ion trap mass spectrometer with electrospray positive ionisation. The monitored ions were 216, 253, 255, 268, 270 m/z derived from 415 m/z for derivatized captopril. The sample preparation was very simple and consisted in plasma protein precipitation from 0.2 mL plasma using 0.3 mL methanol after the derivatization reaction was completed. Calibration curves were generated over the range of 10-3000 ng/mL with values for coefficient of correlation greater than 0.993 and by using a weighted (1/y2) quadratic regression. The values for precision (CV %) and accuracy (relative error %) at quantification limit were less than 9.9% and 3.9%, for within- and between-run, respectively. The mean recovery of the analyte was 99%. Derivatized samples demonstrated good short-term, long-term, post-preparative and freeze-thaw stability. This is the first reported LC-MS/MS method for analysis of captopril in human plasma that uses protein precipitation as sample processing procedure. The method is very simple and allows obtaining a very good recovery of the analyte. The validated LC-MS/MS method has been applied to a pharmacokinetic study of 50 mg captopril tablets on healthy volunteers.  相似文献   

10.
Ruecha N  Siangproh W  Chailapakul O 《Talanta》2011,84(5):1323-1328
In this work, the rapid detection of cholesterol using poly(dimethylsiloxane) microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, was developed. Direct amperometric detection for poly(dimethylsiloxane) (PDMS) microchip capillary electrophoresis was successfully applied to quantify cholesterol levels. Factors influencing the performance of the method (such as the concentration and pH value of buffer electrolyte, concentration of cholesterol oxidase enzyme (ChOx), effect of solvent on the cholesterol solubility, and interferences) were carefully investigated and optimized. The migration time of hydrogen peroxide, product of the reaction, was less than 100 s when using 40 mM phosphate buffer at pH 7.0 as the running buffer, a concentration of 0.68 U/mL of the ChOx, a separation voltage of +1.6 kV, an injection time of 20 s, and a detection potential of +0.5 V. PDMS microchip capillary electrophoresis showed linearity between 38.7 μg/dL (1 μM) and 270.6 mg/dL (7 mM) for the cholesterol standard; the detection limit was determined as 38.7 ng/dL (1 nM). To demonstrate the potential of this assay, the proposed method was applied to quantify cholesterol in bovine serum. The percentages of recoveries were assessed over the range of 98.9-101.8%. The sample throughput was found to be 60 samples per hour. Therefore, PDMS microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, is very rapid, accurate and sensitive method for the determination of cholesterol levels.  相似文献   

11.
A new extraction procedure based on an off-line extraction column was proposed for extracting of available phosphorus from soils. The column was fabricated from a plastic syringe fitted at the bottom with a cotton wool and a piece of filter paper to support a soil sample. An aliquot (50 mL) of extracting solution (0.05 M HCl + 0.0125 M H2SO4) was used to extract the sample under gravity flow and the eluate was collected in a polyethylene bottle. The extract was then analyzed for phosphorus contents by a simple flow injection amperometric system, employing a set of three-way solenoid valves as an injection valve. The method is based on the electrochemical reduction of 12-molybdophosphate which is produced on-line by the reaction of orthophosphate with acidic molybdate and the electrical current produced was directly proportional to the concentration of phosphate in range of 0.1-10.0 mg L−1 PO4-P, with a detection limit of 0.02 mg L−1. Relative standard for 11 replicate injections of 5 mg L−1 PO4-P was 0.5%. A sample through put of 35 h−1 was achieved, with consumption of 14 mg KCl, 10 mg ammonium molybdate and 0.05 mL H2SO4 per analysis. The detection system does not suffer from the interferences that are encountered in the photometric method such as colored substances, colloids, metal ions, silicate and refractive index effect (Schlieren effect). The results obtained by the column extraction procedure were well correlated with those obtained by the steady-state extraction procedure, but showed slightly higher extraction efficiency.  相似文献   

12.
Multidimensional analysis of instant coffee and barley beverage samples using size exclusion chromatography (SEC) combined with a dynamic surface tension detector (DSTD) and a UV-vis absorbance detector (UV) is reported. A unique finding of this study was the action of the tetrabutylammonium (TBA) cation as a modifying agent (with bromide as the counter anion) that substantially increased the surface pressure signal and sensitivity of many of the proteins in the chromatographically separated samples. The tetrabutylammonium bromide (TBAB) enhancement of the surface pressure signal was further investigated by studying the response of 12 commercial standard proteins (α-lactalbumin, β-lactoglobulin, human serum albumin (HSA), albumin from chicken egg white (OVA), bovine serum albumin (BSA), hemoglobin, α-chymotrypsinogen A, cytochrome C, myoglobin, RNase A, carbonic anhydrase, and lysozyme) in buffer performed using flow injection analysis (FIA) coupled with the DSTD with and without various concentrations of TBAB. The FIA-DSTD data show that 1 mM TBAB enhances sensitivity of HSA detection, by lowering the limit of detection (LOD) from 2 mg/mL to 0.1 mg/mL. Similarly, the LOD for BSA was reduced from 1 mg/mL to 0.2 mg/mL. These FIA-DSTD experiments allowed the detection conditions to be optimized for further SEC-UV/DSTD experiments. Thus, the SEC-UV/DSTD system has been optimized and successfully applied to the selective analysis of surface-active protein fractions in a commercial instant coffee sample and in a soluble barley sample. The complementary selectivity of using the DSTD relative to an absorbance detector is also demonstrated.  相似文献   

13.
Based on the enhancement of chemiluminescence (CL) of luminol-hydrogen peroxide-gold nanoparticles system by fluoroquinolones (FQs), a novel and rapid CL method is reported for the determination of FQs derivatives. Under the optimum conditions, the CL intensity is proportional to the concentration of FQs derivative in solution. The corresponding linear regression equations are established over the range of 0.08-1.28 μg/mL for norfloxacin, 0.013-1.32 μg/mL for ciprofloxacin, 0.014-1.4 μg/mL for lomefloxacin, 0.029-1.46 μg/mL for fleroxacin, 0.02-1.0 μg/mL for ofloxacin and 0.01-1.44 μg/mL for levofloxacin, respectively. The limits of detection (S/N = 3) are 3.2, 9.5, 7.0, 9.0, 8.0, and 8.0 ng/mL with the relative standard deviation (n = 11) 4.3, 1.5, 1.9, 1.3, 1.6 and 2.1% for norfloxacin, ciprofloxacin, lomefloxacin, fleroxacin, ofloxacin and levofloxacin, respectively. This proposed method has been applied to detect FQs derivatives in human urine successfully.  相似文献   

14.
Zhang X  Liu F  Yan R  Xue P  Li Y  Chen L  Song C  Liu C  Jin B  Zhang Z  Yang K 《Talanta》2011,85(2):1070-1074
Staphylococcal enterotoxin B (SEB) is a potent gastrointestinal toxin and is heat resistant. SEB is also a potential bioterrorism agent. The ability to measure accurately very low amounts of staphylococcal enterotoxin B in food and other samples is very important. A highly sensitive and stable sandwich fluorescence immunoassay based on a pair of monoclonal antibodies against SEB which were produced by us was developed. Classical sandwich immunoassay was adopted and the glass slides were used as the base of the immunologic reaction. The functionalized fluorescent core-shell silica nanoparticles were used as labels. The fluorescence issued from the labels was detected by a laser-induced fluorescence millimeter sensor array detection platform. The fluorescence intensity has a linear relationship with the amount of SEB in the range of 50 pg/mL-5 ng/mL, and the detection limit of SEB was 20 pg/mL (the absolute detection limit was 0.02 pg). The relative standard deviation (RSD) for 5 parallel measurements of SEB (1 ng/mL) was 9.2%.  相似文献   

15.
The routine method of paper chromatography includes five steps: spotting, separating, drying, spraying/immersing and color development. In this paper, a pre-staining paper chromatography which only consisted of spotting, separating and color development was developed for quantitative analysis of γ-aminobutyric acid. Compared to the routine paper chromatography, the improved method is clean, rapid, inexpensive and reproducible. The effects of ninhydrin concentration, color temperature, color time and Cu2+ concentration on the color yield in the ninhydrin reaction were optimized. And then the pre-staining paper chromatography coupled with vis spectrophotometry was applied to γ-aminobutyric acid quantification. The results indicated that the limit of detection was 0.05 mg mL−1 and the linear range was from 0.5 to 20.0 mg mL−1. Furthermore, an excellent correlation coefficient was observed with an R2 = 0.998. The method is accurate (RSD < 2.64%), and has good recoveries (102.7–103.9%). The validation of the modified technique was verified by a HPLC method.  相似文献   

16.
Yinhuan Li  Weifen Niu 《Talanta》2007,71(3):1124-1129
A flow injection chemiluminescence method was described for the determination of four phenothiazine drugs, namely, chlorpromazine hydrochloride, perphenazine hydrochloride, fluphenazine hydrochloride and thioridazine hydrochloride. Strong Chemiluminescence (CL) signal was produced when above-mentioned drug was injected into the mixed stream of luminol with KMnO4. The linear ranges of the method were 0.0020-1.0 μg/mL chlorpromazine hydrochloride, 0.0040-3.0 μg/mL perphenazine hydrochloride, 0.0020-5.0 μg/mL fluphenazine hydrochloride and 0.0050-1.0 μg/mL thioridazine hydrochloride. The detection limits were 0.4 ng/mL chlorpromazine hydrochloride, 0.7 ng/mL perphenazine hydrochloride, 2 ng/mL fluphenazine hydrochloride and 0.7 ng/mL thioridazine hydrochloride. The proposed method was applied to the determination of chlorpromazine hydrochloride in injections and in mental patient's urine samples and the satisfactory results were achieved. The possible CL reaction mechanism was also discussed briefly.  相似文献   

17.
Hui-Xin Liu  Ying Hu  Yong Liu  Ling Yang 《Talanta》2009,79(5):1433-1336
A simple and sensitive method for determination of the O-demethylation activity of rat, dog, minipig, and human liver micrsomes toward paeonol using ultra-performance liquid chromatography with mass detection (UPLC-MS) has been developed. The method uses chemically synthesized O-demethylated metabolite of paeonol (2,4-dihydroxyacetophenone, DHA) as a standard for method validation. Validation was done with respect to specificity, linearity, detection limit, recovery, stability, precision and accuracy. The chromatographic separation was achieved on a UPLC BEH C18 column (50 mm × 2.1 mm i.d., 1.7 μm), with phase of acetonitrile-water (ratio 30:70). Selective ion reaction (SIR) monitor was specific for paeonol, DHA and I.S. The method was specific since there were no interference peaks from the reaction matrix. The calibration curve for DHA was linear from 0.5-100 μM with r2 = 0.9999. The newly developed method has good precision and accuracy. The method was successfully used to determine the kinetics of DHA activities toward paeonol in liver microsomes from different species. Dog liver microsomes (DLMs) were the most active in paeonol O-demethylation (709.7 pmol/min/mg protein) followed by rat liver microsomes (RLMs) (579.6 pmol/min/mg protein), HLMs (569.3 pmol/min/mg protein), and then minipig liver microsomes (PLMs) (417.3 pmol/min/mg protein). The developed method was appropriated for rapid screening paeonol O-demethylation activity in liver microsomes from different species.  相似文献   

18.
A simple and sensitive automated method for determination of aflatoxins (B1, B2, G1, and G2) in nuts, cereals, dried fruits, and spices was developed consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–mass spectrometry (LC–MS). Aflatoxins were separated within 8 min by high-performance liquid chromatography using a Zorbax Eclipse XDB-C8 column with methanol/acetonitrile (60/40, v/v): 5 mM ammonium formate (45:55) as the mobile phase. Electrospray ionization conditions in the positive ion mode were optimized for MS detection of aflatoxins. The pseudo-molecular ions [M+H]+ were used to detect aflatoxins in selected ion monitoring (SIM) mode. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample using a Supel-Q PLOT capillary column as an extraction device. The extracted aflatoxins were readily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME LC–MS with SIM method, good linearity of the calibration curve (r > 0.9994) was obtained in the concentration range of 0.05–2.0 ng/mL using aflatoxin M1 as an internal standard, and the detection limits (S/N = 3) of aflatoxins were 2.1–2.8 pg/mL. The in-tube SPME method showed >23-fold higher sensitivity than the direct injection method (10 μL injection volume). The within-day and between-day precision (relative standard deviations) at the concentration of 1 ng/mL aflatoxin mixture were below 3.3% and 7.7% (n = 5), respectively. This method was applied successfully to analysis of food samples without interference peaks. The recoveries of aflatoxins spiked into nuts and cereals were >80%, and the relative standard deviations were <11.2%. Aflatoxins were detected at <10 ng/g in several commercial food samples.  相似文献   

19.
Silicon is an essential trace element and is found in vegetables, fruits, cereals, water, pasta and rice (Oryza sativa). In this work, the silica content of different types of rice grains were measured. Here, we used the heteropoly blue photometric method with a double beam UV-vis spectrophotometer to determine the amount of silicon in rice samples (n = 7) that were collected in the north of Iran. The samples were digested with wet-ashing method by microwave-assisted heating and then treated with ammonium molybdate to produce a yellow color compound in acidic solution (ca. pH 1.2) and then reduced to give a heteropoly compound with a blue color. Analyses were performed using standard addition method and absorbance values were measured with double beam UV-vis spectrophotometer at λmax = 815 nm. Results indicated that the silica content was 307-451 mg/kg for the samples. X-ray diffraction patterns and infra-red spectra were obtained from rice samples without any sample treatment.  相似文献   

20.
An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination of trantinterol enantiomers in rat plasma. Diphenhydramine was employed as the internal standard. The plasma samples were prepared using liquid-liquid extraction with n-hexane-dichloromethane-isopropanol (20:10:1, v/v/v) as the extractant. Trantinterol enantiomers after pre-column derivatization using diacetyl-l-tartaric anhydride (DATAAN) were separated on a C18 column using a gradient solvent programme. The mobile phase was composed of 3 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI). Linear calibration curve for each enantiomer was obtained in the concentration range of 1-80 ng/mL, with limit of quantification (LOQ) of 1 ng/mL. The intra- and inter- precision (R.S.D.) values were below 9.6% and accuracy (R.E.) was from −2.4 to 6.2% at all quality control (QC) levels. The developed method was applied to the enantioselective pharmacokinetic study of trantinterol in rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号