首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents two easy and selective methods for determining the active principles nafronyl (NFL) and naproxen (NAP), using a flow-through fluorescence optosensor based on the on-line immobilization on a nonionic-exchanger (Silica Gel, Davisil™ and Amberlite XAD 7, respectively) solid support. The determination was performed in 5×10−3 M HAc/NaAc buffer solution at pH 5 for NFL and 15×10−3 M glycine/HCl buffer solution at pH 2.5 for NAP at a working temperature of 20 °C. The fluorescence intensities were measured at λex/em=294/336 nm and λex/em=332/354 nm for NFL and NAP, respectively. The response time for these optosensors were practically instant, obtaining a linear concentration range between 0 and 700.0 ng ml−1 with a detection limit of 20.8 ng ml−1, an analytical sensitivity of 10.1 ng ml−1 and a standard deviation of 1.27% at a 500 ng ml−1 concentration level for NFL and a linear concentration range between 0 and 200.0 ng ml−1 with the detection limit of 13.3 ng ml−1, an analytical sensitivity of 6.0 ng ml−1 and a standard deviation of 3.52% at a 100 ng ml−1 concentration level for NAP. The proposed methods were satisfactorily applied to real samples (three commercial formulations and urine samples). The effects of the possible interferences were evaluated in all cases.  相似文献   

2.
A simple and highly selective flow injection (FI) on-line preconcentration and separation flame atomic absorption spectrometric (FAAS) method was developed for the determinations of trace amounts of silver, gold and palladium. The selective preconcentration of the noble metals was achieved in a wide range of sample acidity (0.1-6 M HNO3 or HCl) on a microcolumn packed with amidinothioureido-silica gel (ATuSG). The analytes retained on the column were effectively eluted with 5.0% thiourea solution. The analytical procedure was optimized for sample acidity, elution, interferences, flow rate of sampling and eluting, and concentration of sample. Common co-existing cations and anions did not interfere with the preconcentration and determination of the three metals. At a sample loading flow rate of 4.5 ml min−1 with 60 s preconcentration, detection limits (3σ) of 1.1 ng ml−1 Ag, 13 ng ml−1 Au and 17 ng ml−1 Pd were obtained. The precisions (R.S.D., n=11) were 1.2% for Ag, 1.2% for Au and 1.7% for Pd, respectively. The detection limits can be further improved by increasing sample volume. The analytical results obtained by the proposed method for a number of standard reference materials were in good agreement with the certified values.  相似文献   

3.
In pH 6.0-11.2 Britton-Robinson buffer solution, binding of heparin with crystal violet (CV) can result in a significant enhancement of resonance Rayleigh scattering (RRS) and resonance non-linear scattering, such as frequency doubling scattering (FDS) and second-order scattering (SOS). Their maximum scattering wavelengths, λex/λem, appear at 492 nm/492 nm for RRS, 984 nm/492 nm for FDS and 492 nm/984 nm for SOS, respectively. The optimum conditions of the reaction, the influencing factors and the relationship between the three scattering intensities and the concentration of heparin have been investigated. New methods for the determination of trace amounts of heparin based on the RRS, FDS and SOS methods have been developed. The methods exhibit high sensitivities, the detection limit for heparin is 2.9 ng ml−1 for the RRS method, 3.5 ng ml−1 for the FDS method and 3.3 ng ml−1 for the SOS method. The methods have good selectivity and were applied to the determination of heparin in heparin sodium injection samples with satisfactory results.  相似文献   

4.
A highly sensitive catalytic quenching spectrofluorimetric method was described for the determination of V(V) based on its catalytic effect on the oxidation of 1,8-diaminonaphthalene by potassium bromate with Tiron as an activator in weakly acidic medium and the reaction mechanism was investigated. The reaction was followed spectrofluorimetrically by measuring the fluorescence intensity of 1,8-diaminonathphlene (DAN) (λex=356 nm, λem=439 nm) at a fixed time of 5 min from initiation of the reaction. Under the optimum conditions, vanadium(V) can be determined in the range 0.05-50.0 ng ml−1 with a S.D.=0.024 for 15 times measurements. The detection limit of the method was down to 0.0088 ng ml−1 and the catalytic reaction activation energy was found to be 43.92 kJ mol−1. The proposed method was tested for the determination of vanadium(V) in rice and natural water samples.  相似文献   

5.
Luminescent silicon dioxide nano-particles with size of 20 nm, which containing dibromofluorescein (D) were synthesized by sol-gel method (symbolized by D-SiO2).The particles can emit intense and stable room temperature phosphorescence signal on polyamide membrane when Pb(Ac)2 was used as a heavy atom perturber. The λexmax/λemmax was 457/622 nm. Our research indicated that the specific immune reaction between goat-anti-human IgG antibody labeled with D-SiO2 and human IgG could be carried out on polyamide membrane quantitatively, and the phosphorescence intensity of the particle was enhanced after the immunoreactions. Thus a new method of solid substrate room temperature phosphorescence immunoassay (SS-RTP-IA) for the determination of human IgG was established basing on antibody labeled with the D-SiO2 nanoparticles. The linear range of this method was 0.0624-20.0 pg human IgG spot−1 (corresponding concentration: 0.156-50.0 ng ml−1, the sample volume: 0.40 μl spot−1) with a limit of detection (LD) as 0.018 pg spot−1, and the regression equation of working curve was ΔIp = 7.201 mIgG (pg spot−1) + 82.57. Samples containing 0.156 and 50.0 ng ml−1 of IgG were measured repeatedly for 11 times and R.S.D.s were 4.1 and 3.4%, respectively. Results showed that this method had the merits as sensitive, accurate and precise.  相似文献   

6.
Yoon KH  Lee SY  Jang M  Ko SH  Kim W  Park JS  Park I  Kim HJ 《Talanta》2005,66(4):831-836
A simple, fast and sensitive high-performance liquid chromatography (HPLC)-electrospray ionization (ESI) tandem mass spectrometric method (LC-MS/MS) has been developed for determination of propiverine and propiverine N-oxide metabolite in human plasma using oxybutynin as internal standard. Instead of extracting propiverine from plasma using organic solvents, which should be separated from the aqueous phase and evaporated before injecting the sample into the chromatograph, plasma sample containing propiverine and N-oxide was directly injected after precipitating proteins with acetonitrile. Numerous compounds in the plasma did not interfere with the highly specific multiple reaction monitoring in tandem mass spectrometric detection following C8 reversed-phase chromatographic separation under conditions that eluted propiverine, N-oxide and oxybutynin within 2 min (0.1% formic acid in water/acetonitrile, 25:75, v/v). The LC-MS/MS method and an alternative LC-MS method, using methyl-t-butyl ether extraction and selected ion monitoring, were validated over 1-250 ng ml−1 of propiverine and 2 to 500 ng ml−1 of N-oxide, and successfully applied in a pharmacokinetic study. The lower limit of quantitation was 1 ng ml−1 for propiverine and 2 ng ml−1 for N-oxide in both methods.  相似文献   

7.
A simple, sensitive, low-cost and rapid, flow injection system for the on-line preconcentration of lead by sorption on a microcolumn packed with silica gel funtionalized with methylthiosalicylate (TS-gel) was developped. The metal is directly retained on the sorbent column and subsequently then eluted from it by EDTA. Five variables (sample flow rate, eluent flow rate, eluent concentration, pH and buffer concentration) were considered as factors in the optimization process. Interactions between analytical factors and their optimal levels were investigated using two level factorial and Box-Behnken designs. The optimum conditions established were applied to the determination of lead by flow injection inductively coupled plasma atomic emission spectrometry (FI-ICP-AES). The proposed method has a linear calibration range from 10 to at least 500 ng ml−1 of lead. At a sample frequency of 24 h−1 and a 120 s preconcentration time, the enrichment factor was 41, the detection limit was 15.3 ng ml−1 (S/N=3) and the precision, expressed as relative standard deviation, was 0.9% (at 100 ng ml−1). Validation of the developed method was carried out against electrothermal atomic absorption spectrometry analysis without statistically significant differences between the proposed method and the atomic absorption method.  相似文献   

8.
Biswas S  Chowdhury B  Ray BC 《Talanta》2004,64(2):308-312
A highly sensitive and virtually specific method has been developed for the trace and ultra trace 5 ng ml−1-1 μg ml−1 fluorimetric analysis of nitrite. The method is based on the quenching action of nitrite on the native fluorescence of murexide (ammonium purpurate) [λex=349.0 nm, λem=444.5 nm] in the acid range of 0.045-0.315 (M) H2SO4. The method is very precise and accurate (S.D.=±0.4877 and R.S.D.=0.4878% for the determination of 0.1 μg ml−1 of nitrite in 11 replicates). Relatively large excesses of over 35 cations and anions do not interfere. The proposed technique has been successfully applied for the determination of nitrite and nitrate in ground water, surface water and sea water, nitrite in soil and nitrate in forensic samples. The method has also been extended for the analysis of NOx in air.  相似文献   

9.
Jiang H  Hu B  Jiang Z  Qin Y 《Talanta》2006,70(1):7-13
A new method using a microcolumn packed with YPA4 chelating resin as solid-phase extractor has been developed for the separation and preconcentration of trace Hg prior to its measurement by GFAAS with Pd as a permanent modifier. Various parameters such as the amount of the modifier, pH, sample flow rate, the concentration and volume of eluent have been studied in order to find the best conditions for the determination of mercury. The detection limit of the method (3σ) for Hg based on an enrichment factor of 100 was 0.2 ng ml−1. A characteristic mass of 114 pg was obtained for mercury using Pd as a permanent modifier. The relative standard deviation was 2.8% at the 10 ng ml−1 level (n = 5). The method has been applied to the determination of trace mercury in environmental water samples and the recoveries for the spiked samples are in the range of 91-105%.  相似文献   

10.
This paper describes a highly sensitive, selective catalytic-kinetic-spectrophotometric method for the determination of copper(II) concentration as low as 6 ng ml−1. The method is based on the catalytic effect of copper(II) on the oxidation of citric acid by alkaline hexacyanoferrate(III). The reaction was followed by measuring the decrease in absorbance of hexacyanoferrate(III) at 420 nm (λmax of [Fe(CN)6]3−,  = 1020 dm3 mol−1 cm−1). The dependence of rate of the indicator reaction on the reaction variables has been studied and discussed to propose a suitable mechanism to get a relation between the reaction rate and [Cu2+]. A fixed time procedure has been used to obtain a linear calibration curve between the initial rate and lower [Cu2+] or log[Cu2+] in the range 1 × 10−7 to 4 × 10−4 mol l−1 (6.35-25,400 ng ml−1). The detection limit has been calculated to be 4 ng ml−1. The maximum average error is 3.5%. The effect of the presence of various cations, commonly associated with copper(II) and some anions has also been investigated and discussed. The proposed method is sensitive, accurate, rapid and inexpensive compared to other techniques available for determination of copper(II) in such a large range of concentration. The new method has been successfully applied for the determination of copper(II) in various samples.  相似文献   

11.
Based on direct hapten coated format a competitive indirect enzyme-linked immunosorbent assay (ciELISA) for bisphenol A (BPA) was developed. Polystyrene surface was modified by 3-Aminopropyltriethoxysilane (APTES) to produce amino groups after H2SO4/HNO3-pre-treatment. 4,4-bis (4-hydroxyphenyl) valeric acid (BVA) which is analogue of BPA, was successfully immobilized on the surface of microtiter plates by N,N′-dicyclohexylcarbodiimide (DCC) method. The essential steps of the assay were optimized, especially blocking procedure which is key step to prevent unspecific binding of antibody. The results indicated that compared with hapten-protein coated format (IC50 = 176.67 ng ml−1, LOD = 15.90 ng ml−1), the direct hapten coated format (IC50 = 23.50 ng ml−1, LOD = 0.27 ng ml−1) could improve assay sensitivity and the detection ranges were 2.30 ng∼157.60 ng ml−1 with good signal reproducibility (P value > 0.05) after careful optimization of assay conditions. Tap water samples and seawater samples were spiked with a known amount of BPA and measured by ciELISA. The average recoveries were between 70 and 142%. As far as we are aware this is the most sensitive ELISA for BPA yet reported.  相似文献   

12.
Fenitrooxon [O,O-dimethyl-O-(4-nitro-m-tolyl)phosphate] is the major metabolite of the organophosphorus insecticide fenitrothion, and 3-methyl-4-nitrophenol is its major degradation product. In the present study, we describe the development of an indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of these compounds in water samples based on a group-specific polyclonal antiserum generated with a “bifunctional hapten”, which has two functions: the conventional function of producing an antibody against an antigen and a unique function of promoting the production of the antibodies in rabbit. For application to water samples, the influence of several factors such as organic solvent, pH, and detergent was studied. Under optimized conditions, the quantitative working range of the fenitrooxon ELISA was 0.71-27 ng ml−1 with a limit of detection (LOD) of 0.32 ng ml−1, and the fenitrooxon concentration giving 50% reduction of the maximum signal (IC50) was 4.2 ng ml−1. The quantitative working range of the 3-methyl-4-nitrophenol ELISA was 0.67-27 ng ml−1 with a LOD of 0.38 ng ml−1 and an IC50 of 3.7 ng ml−1. No significant matrix effect originating from the water sample (river water, tap water, purified water, and bottled water) was shown by addition of Tween 20 to the assay buffer. Water samples spiked with each of these compounds at 1, 5, 10, and 20 ng ml−1 were directly analyzed without extraction and clean-up by the proposed ELISA. The mean recovery was 100.9%, and the mean coefficient of variation (CV) was 7.7% for the fenitrooxon ELISA and for the 3-methyl-4-nitrophenol ELISA, the mean recovery was 97.6%, and the mean CV was 7.2%. The proposed ELISA allows precise and accurate determination of these compounds in water at such low levels.  相似文献   

13.
A sensitive and simple solid-phase preconcentration procedure for enrichment of cadmium prior to analysis by flame atomic absorption spectrometry (FAAS) is described. The method is based on the adsorption of cadmium as CdI42− on naphthalene-methyltrioctylammonium chloride adsorbent, elution by nitric acid and subsequent determination by FAAS. The effect of pH, iodide concentration, sample flow rate, volume of the sample and diverse ions on the recovery of the analyte was investigated and optimum conditions were established. A preconcentration factor of 40 was achieved using the optimum conditions. The calibration graph was linear in the range 1-100 ng ml−1 cadmium in the initial solution. The detection limit based on the 3Sb criterion was 0.6 ng ml−1 and the relative standard deviations (RSD) were 3.9 and 1.05% for 5 and 40 ng ml−1, respectively (n=8). The method was successfully applied to the determination of cadmium added to river, tap and Persian Gulf water samples.  相似文献   

14.
Dai XX  Li YF  He W  Long YF  Huang CZ 《Talanta》2006,70(3):578-583
A dual-wavelength resonance lighting scattering (DW-RLS) ratiometry is developed to detect anion biopolymer based on their bindings with cation surfactant. Using the interaction of Hyamine 1622 (HM) with fish sperm DNA (fsDNA) as an example, a dual-wavelength resonance light scattering (DW-RLS) ratiometric method of DNA was constructed. In Britton-Robinson buffer controlled medium, fish sperm DNA (fsDNA) could interact with Hyamine 1622 (HM), displaying significantly enhanced RLS signals. By measuring the RLS signals characterized at 300.0 nm (I300.0) and the RLS intensity ratio (I276.0/I294.0), respectively, fsDNA over a wide dynamic range of content could be detected. Typically, when HM concentration is kept at 6.0 × 10−5 mol l−1, using I300.0 could detect fsDNA over the range of 50-2000 ng ml−1 with the limit of 3.0 ng ml−1, while using I276.0/I294.0 could detect fsDNA over the range of 0.5-2500 ng ml−1 with the limit of 0.05 ng ml−1. Thus the latter so-called DW-RLS ratiometry is obviously superior to the former one. Based on the measurements of I300.0 and I276.0/I294.0 data, a Scatchard plot concerning the interaction between HM and fsDNA could be constructed and thus the binding number (n) and binding constant (K) could be available with the values of 13.5 and 1.35 × 105 mol−1 l, and 11.9 and 1.65 × 105 mol−1 l, respectively.  相似文献   

15.
Sun Y  Tang Y  Yao H  Zheng X 《Talanta》2004,64(1):156-159
A sensitive flow injection chemiluminescence (FL-CL) method for the determination of cephalosporin antibiotics, was developed. The method was based on that cephalosporin antibiotics could enhance the CL reaction of glyoxal and KMnO4 in sulfuric acid. Method development included the optimization of reagent concentrations and flow-rate. Under the optimized conditions, three cephalosporin antibiotics: cefalexin, cefadroxil, and cefazolin sodium, were determined. The detection limits of the method are 10 ng ml−1 cefalexin, 2 ng ml−1 cefadroxil, and 2 ng ml−1 cefazolin sodium. The method was successfully applied to the determination of three cephalosporin antibiotics in pharmaceutical preparations.  相似文献   

16.
A high-performance liquid chromatographic method has been developed for the determination in human plasma of the specific serotonin reuptake inhibitor (SSRI) antidepressant paroxetine and its three main metabolites (M1, M2, M3). Fluorescence detection was used, exciting at λ = 294 nm and monitoring emission at λ = 330 nm for paroxetine (λexc = 280 nm, λem = 330 nm for M1 and M2; λexc = 268 nm, λem = 290 nm for M3). Separation was obtained on a reversed-phase C18 column using a mobile phase composed of 66.7% aqueous phosphate at pH 2.5 and 33.3% acetonitrile. Imipramine (λexc = 252 nm, λem = 390 nm) was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with C8 cartridges (50 mg, 1 mL). The calibration curves were linear over a working range of 2.5-100 ng mL−1 for paroxetine and of 5-100 ng mL−1 for all metabolites. The limit of detection (LOD) was 1.2 ng mL−1 for PRX and 2.0 ng mL−1 for the metabolites. The method was applied with success to plasma samples from depressed patients undergoing treatment with paroxetine. Hence, the method seems to be suitable for the therapeutic drug monitoring of paroxetine and its main metabolites in depressed patients’ plasma.  相似文献   

17.
A novel flow-injection spectrophotometry has been developed for the determination of molybdenum(VI) at nanograms per milliliter levels. The method is based on the catalytic effect of molybdenum(VI) on the bromate oxidative coupling of p-hydrazinobenzenesulfonic acid with N-(1-naphthyl)ethylenediamine to form an azo dye (λmax = 530 nm). Chromotropic acid (4,5-dihydroxy-2,7-naphthalenedisulfonic acid) acted as an effective activator for the molybdenum(VI)-catalyzed reaction and increased the sensitivity of the method. The reaction was monitored by measuring the change in absorbance of the dye produced. The proposed method allowed the determination of molybdenum(VI) in the range 1.0-20 ng mL−1 with sample throughput of 15 h−1. The limit of detection was 0.5 ng mL−1 and a relative standard deviation for 10 ng mL−1 molybdenum(VI) (n = 10) was 2.5%. The interfering ions were eliminated by using the combination of a masking agent and on-line minicolumn packed with cation exchanger. The present method was successfully applied to the determination of molybdenum(VI) in plant foodstuffs.  相似文献   

18.
A sensitive and selective preconcentration method has been developed for mercury using naphthalene-methyltrioctylammonium chloride (Aliquat 336s) as an adsorbent. Mercury as HgI42− was retained by the adsorbent in the column at a flow rate of 1 ml min−1. The column was washed by a solution of sodium tetraphenylborate and sodium iodide to elute the adsorbed mercury. The eluents were collected in a 10 ml volumetric flask and diluted to the mark with water, transferred to a voltammetric cell and anodic stripping-differential pulse voltammetry was performed. Preconcentration factors of 40 and 80 could be achieved when using a 10 and 5 ml voltammetric cell, respectively. The calibration graph was linear in the range of 1.2-8.7 ng ml−1 Hg(II) in the initial solution with r=0.9998 (n=6) and the 3 s detection limit was 0.13 ng ml−1 when using a 10 ml cell. The relative standard deviation for eight replicate measurements of 1.2, 5.0 and 8.7 ng ml−1 of Hg(II) in the initial solution was 0.51, 0.71 and 0.80%, respectively. The proposed method was successfully applied to determination of mercury in natural waters, wastewater and synthetic samples.  相似文献   

19.
A flow injection amperometric immunoassay system based on the use of screen-printed carbon electrode for the detection of mouse IgG was developed. An immunoelectrode strip, on which an immunosorbent layer and screen-printed carbon electrode were integrated, and a proposed flow cell have been fabricated. The characterization of the flow immunoassay system and parameters affecting the performance of the immunoassay system were studied and optimized. Amperometric detection at 0.0 V (versus Ag/AgCl) resulted in a linear detection range of 30-700 ng ml−1, with a detection limit of 3 ng ml−1. The signal variation among electrode strips prepared from variant batch did not exceed 8.5% (n=7) by measuring 0.5 μg ml−1 antigen standard solution.  相似文献   

20.
《Analytica chimica acta》2002,459(2):235-243
For the first time, a solid sensing zone implemented with unsegmented flow analysis is described for the simultaneous determination of two pesticides, thiabendazole and warfarin. The system works as a simple and rapid spectrofluorimetric biparameter sensor. The sensor is based on the retention of the analytes on the sensing solid zone (octadecyl silane C18 gel) placed in the detection zone itself into a quartz flow-cell. A temporary sequentiation in the arrival of the analytes to the sensing zone is achieved by on line separation using a pre-column of the same gel placed just before the flow cell. Thiabendazole is determined the first (using methanol 30% (v/v) as carrier/elution solution) because it passes through the pre-column while warfarin is strongly retained in it. Then, warfarin is conveniently eluted from the pre-column (using methanol 50% (v/v) as carrier/elution solution) the intrinsic fluorescence peak height measured at an excitation wavelength of 309 nm and an emission wavelength of 368 nm is used as analytical signal. Using a low sample volume (40 μl), the analytical signal showed a very good linearity in the range 10-800 ng ml−1 and 2-40 μg ml−1 with detection limits of 2.35 ng ml−1 and 0.54 μg ml−1 for thiabendazole and warfarin, respectively. The sensor was satisfactorily applied to the determination of these two analytes in pesticides and pharmaceutical preparations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号