首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A new sensor was developed for simultaneous detection of cadmium (Cd2+), copper (Cu2+), and lead (Pb2+), based on the voltammetric response at a carbon paste electrode modified with carbamoylphosphonic acid (acetamide phosphonic acid) self-assembled monolayer (SAM) on mesoporous silica (Ac-Phos SAMMS). The adsorptive stripping voltammetry (AdSV) technique involves preconcentration of the metal ions onto Ac-Phos SAMMS under an open circuit, then electrolysis of the preconcentrated species, followed by a square wave potential sweep towards positive values. Factors affecting the preconcentration process were investigated. The voltammetric responses increased linearly with the preconcentration time from 1 to 30 min or with metal ion concentrations ranging from 10 to 200 ppb. The responses also evolved in the same fashion as adsorption isotherm in the pH range of 2-6. The metal detection limits were 10 ppb after 2 min preconcentration and improved to 0.5 ppb after 20 min preconcentration.  相似文献   

2.
Heavy metals in drinking water have become a severe threat to human health. Detection of heavy metals has been achieved by electrochemical sensors that are modified with complex nanocomposites; however, reproducibility of these sensors is still a big challenge when applied in commercial settings. Here, a simple, very robust, and sensitive electrochemical sensor based on a screen-printed carbon electrode modified with butterfly-shaped silver nanostructure (AgNS/SPCE) has been developed for the concurrent determination of cadmium (II), lead (II), copper (II), and mercury (II) in water samples. The electrochemical behavior of the modified electrodes was investigated using cyclic voltammetry and differential pulse anodic stripping voltammetry. The AgNS/SPCE showed distinct peak potentials and a significant increase in the peak currents for all heavy metals, attributed to the high electrical conductivity and electrocatalytic activity of the synthesized butterfly-shaped AgNS. Moreover, the excellent stability and sensitivity towards simultaneous quantification of heavy metals have been obtained with detection limits of 0.4 ppb, 2.5 ppb, 7.3 ppb, and 0.7 ppb for Cd (II), Pb (II), Cu (II), and Hg (II), respectively. Besides, the constructed sensor was successfully applied to simultaneously quantify target heavy metals in spiked water samples. Owing to excellent sensitivity, high robustness, affordability, and fast response, the presented electrochemical sensor could be incorporated into a portable and miniaturized potentiostat device, making it a promising method for on-site water analysis.  相似文献   

3.
Microanalyzer for biomonitoring lead (Pb) in blood and urine   总被引:1,自引:0,他引:1  
Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. State-of-the-art ICP–MS instruments can only analyze metals in laboratories, resulting in lengthy turnaround times, and they are expensive. In response to the growing need for a metal analyzer capable of on-site, real-time monitoring of trace toxic metals in individuals, we developed a portable microanalyzer based on flow-injection/stripping voltammetry (ASV), and validated the system using rat blood and urine spiked with known amounts of Pb. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with suitable sample pretreatment and by establishing turbulent flow of blood and urine containing Pb onto the electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. No matrix effect was observed for the voltammetric Pb signals, even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration ranges relevant to Pb exposure levels in humans (0–20 ppb in 10% blood samples, 0–50 ppb in 50% urine samples). The device showed excellent sensitivity and reproducibility; Pb detection limits were 0.44 ppb and 0.46 ppb, and % R.S.D. was 4.9 and 2.4 in 50% urine and 10% blood samples, respectively. It gave similar Pb concentrations in blood and urine to those measured by ICP–MS. It offered high throughput (3 min per sample) and economical use of samples (60 μL per measurement) as well as low reagent consumption (1 μg of Hg per measurement), thus minimizing environmental concerns associated with mercury use. Since it is miniaturized, the microanalyzer is portable and field-deployable. Thus, it shows much promise as the next-generation analyzer for the biomonitoring of toxic metals.  相似文献   

4.
Urine is universally recognized as one of the best non-invasive matrices for biomonitoring exposure to a broad range of xenobiotics, including toxic metals. Detection of metal ions in urine has been problematic due to the protein competition and electrode fouling. For direct, simple, and field-deployable monitoring of urinary Pb, electrochemical sensors employing superparamagnetic iron oxide (Fe3O4) nanoparticles with a surface functionalization of dimercaptosuccinic acid (DMSA) has been developed. The metal detection involves rapid collection of dispersed metal-bound nanoparticles from a sample solution at a magnetic or electromagnetic electrode, followed by the stripping voltammetry of the metal in acidic medium. The sensors were evaluated as a function of solution pH, the binding affinity of Pb to DMSA-Fe3O4, the ratio of nanoparticles per sample volume, preconcentration time, and Pb concentrations. The effect of binding competitions between the DMSA-Fe3O4 and urine constituents for Pb on the sensor responses was studied. After 90 s of preconcentration in samples containing 25 vol.% of rat urine and 0.1 g L(-1) of DMSA-Fe3O4, the sensor could detect background level of Pb (0.5 ppb) and yielded linear responses from 0 to 50 ppb of Pb, excellent reproducibility (%RSD of 5.3 for seven measurements of 30 ppb Pb), and Pb concentrations comparable to those measured by ICP-MS. The sensor could also simultaneously detect background levels (<1 ppb) of Cd, Pb, Cu, and Ag in river and seawater.  相似文献   

5.
Yantasee W  Timchalk C  Weitz KK  Moore DA  Lin Y 《Talanta》2005,67(3):617-624
There is a need to develop reliable portable analytical systems for on-site and real-time biomonitoring of lead (Pb) from both occupational and environmental exposures. Saliva is an appealing matrix since it is easily obtainable, and therefore a potential substitute for blood due to existing reasonably good correlation between Pb levels in blood and saliva. The microanalytical system is based on flow-injection/stripping voltammetry with a wall-jet (flow-onto) microelectrochemical cell. Samples that contain as little as 1% saliva can cause electrode fouling, resulting in significantly reduced responsiveness and irreproducible quantitations. In addition, incomplete Pb release from salivary protein can also yield a lower Pb response than expected. This paper evaluates the extent of in vitro Pb-protein binding and the optimal pretreatment for releasing Pb from the saliva samples. Even in 50% by volume of rat saliva, the electrode fouling was not observed, due to the appropriate sample pretreatment and the constant flow of the sample and acidic carrier that prevented passivation by the protein. The system offered a linear response over a low Pb range of 1-10 ppb, low detection limit of 1 ppb, excellent reproducibility, and reliability. It also yielded the same Pb concentrations in unknown samples as did the ICP-MS. These encouraging results suggest that the microanalytical system represents an important analytical advancement for real-time non-invasive biomonitoring of Pb.  相似文献   

6.
Jorge Yánez Heras 《Talanta》2007,71(4):1684-1689
The sequential electrochemical polymerization of aniline and N-(3-propane sulfonic acid)aniline (PSA) is proposed to construct a sensor able to detect ascorbate at physiological conditions. Compared to poly(aniline) modified electrode, a device with improved conducting and electrochemical properties at neutral pH is obtained. The electrochemical copolymerization of the same starting materials is also carried out. For a PSA:aniline ratio of 10:90, a polymer with a similar electrochemical behavior to the one grown in the sequential mode is observed.The detection of ascorbate was tested for both configurations at pH 7.2, the modified electrode is able to determine ascorbate at 0 mV versus Ag/AgCl; an optimized sensor constructed by sequential polymerization can easily detect ascorbate concentrations with a detection limit of 2.2 μM. Uric acid and dopamine does not interfere in the ascorbate determination.  相似文献   

7.
Ying Du 《Talanta》2009,79(2):243-1411
We report a simple and novel method of stirring-only-driven accumulation and electrochemical determination of arsenite (As(III)) with both of the oxidation and reduction peaks associated with As(0)/As(III) using a gold nanofilm electrode in neutral solution. Under stirring, a large amount of As(III) was deposited on the modified electrode and the electrochemical response was greatly amplified. The accumulated As(III) on the electrode showed well-defined redox couple in 0.1 M blank phosphate buffer solution (pH 7.0), which could be used for the measurement of As(III). Under optimal conditions, As(III) could be detected in the range from 0.20 to 375 ppb with a detection limit of 0.04 ppb. In particular, with the use of the reduction peak of As(III) the modified electrode exhibits excellent performance for As(III) determination even in the presence of abundant Cu(II). The regeneration of the electrodes is facile with good reproducibility. The electrochemical system was applied to analyze As(III) in lake water, As(III) spiked tap water and drinking water.  相似文献   

8.
This work describes the synthesis of an organo-inorganic hybrid material and its application as low-cost electrode material for the electrochemical detection of trace levels of lead in contaminated water. The organo-inorganic hybrid material was obtained by the grafting of 1-(2-hydroxyethylpiperazine) (HEP) in the interlayer space of a natural kaolinite (K). The obtained organokaolinite (K-HEP) was characterized by XRD, FTIR and TGA-DTG techniques. XRD results in particular showed that the structure of the pristine kaolinite was not affected during the synthesis of K-HEP. It was also noticed from 13C NMR data that the structure of HEP was preserved during the synthesis process. Taking into account the affinity of the amine group on HEP molecule for lead ions, K-HEP was used to modify the surface of glassy carbon electrode (GCE) (GCE/K-HEP) in order to build a sensor for lead detection. The peak current of Pb(II) recorded on GCE/K-HEP was more intense compared to the signal recorded on bare GCE, and on natural kaolinite film modified GCE. Several parameters that can affect the stripping response were systematically investigated to optimize the sensitivity of the organokaolinite film modified electrode. Under optimized conditions, a calibration curve was obtained in the concentration range from 8.29 to 116.03 ppb; with a detection limit of 0.25 ppb (S/N=3). After the study of some interfering species on the electrochemical response of Pb(II), the developed sensor was successfully applied to the quantification of the same pollutant in tap water and spring water samples.  相似文献   

9.
An amperometric sensor capable of detecting ozone in the low ppb range was developed. The most suitable electrochemical cell was based on a gold-Nafion electrode with 0.5 M H2SO4 as internal electrolyte solution. It is demonstrated, that by careful selection of the experimental conditions such as electrode materials, electrolyte solution and applied potential the determination of low concentrations of ozone in air is possible with detection limits of 0.6 ppb. Cross-sensitivities to the major inorganic gaseous species found in the atmosphere, are also presented, and the use of a chemical filter to circumvent the interference by nitrogen dioxide is described.  相似文献   

10.
J. Treviño  A. Calle  M. Mellado 《Talanta》2009,78(3):1011-1016
A surface plasmon resonance immunoassay has been developed to determine human growth hormone (hGH) directly and without pre-treatment in human serum samples. A binding inhibition immunoassay was employed. Antibody concentration, assay buffer and regeneration solution have been optimized in order to reach the best performance and the lower non-specific binding of the matrix components to the sensor surface. The lowest detection limit was 6 ng/mL, with a working range covering the physiological range. Reproducibility of the assay was excellent with both intra-assay and inter-assay relative standard deviations <5%, while a variation of 2.19% was obtained employing different sensor chips. Reutilization of the sensor surface allows its continuous use over 50 measurements with a signal drop <20%. The SPR immunoassay results were validated using enzyme-linked immunosorbent assay (ELISA) showing an excellent correlation (R2 = 0.985). A portable and fully automated system (Sensia SL) was employed in this work. This is the first SPR biosensor assay capable of detecting relevant concentrations of a clinical analyte in serum. This study shows the potentials of this device as a diagnostic tool for the detection of multiple clinical analytes.  相似文献   

11.
An electrochemical sensor based on the electrocatalytic activity of functionalized graphene for sensitive detection of paracetamol is presented. The electrochemical behaviors of paracetamol on graphene-modified glassy carbon electrodes (GCEs) were investigated by cyclic voltammetry and square-wave voltammetry. The results showed that the graphene-modified electrode exhibited excellent electrocatalytic activity to paracetamol. A quasi-reversible redox process of paracetamol at the modified electrode was obtained, and the over-potential of paracetamol decreased significantly compared with that at the bare GCE. Such electrocatalytic behavior of graphene is attributed to its unique physical and chemical properties, e.g., subtle electronic characteristics, attractive π-π interaction, and strong adsorptive capability. This electrochemical sensor shows an excellent performance for detecting paracetamol with a detection limit of 3.2 × 10−8 M, a reproducibility of 5.2% relative standard deviation, and a satisfied recovery from 96.4% to 103.3%. The sensor shows great promise for simple, sensitive, and quantitative detection and screening of paracetamol.  相似文献   

12.
The development and fabrication of a simple, portable, and sensitive detection tool to precisely monitor nitrite level is of growing importance in electrochemistry research, given the strong interest in the protection of drinking water quality, treatment of wastewater, food production, and control of remediation processes. This work describes the fabrication of a simple, cost-effective, pen-type electrochemical sensor based on bimetallic gold and tungsten nanoparticles electrochemically decorated on graphene-chitosan modified pencil graphite electrode (PGE) for the trace detection of nitrite in real samples. The prepared nanocomposite was characterized using XRD, SEM, and EDS. The electrochemical behavior of the sensor was evaluated by cyclic voltammetry (CV) and impedance electrochemical spectroscopy (EIS). Results revealed that the proposed sensor displayed excellent electrocatalytic activity towards electro-oxidation of nitrite with an irreversible redox reaction. The AuNPs-WNPs@Gr-Chi/PGE sensor exhibited excellent analytical performance with a wide linear range from 10 to 250 μM towards nitrite. The LOD and LOQ were calculated to be 0.12 μM and 0.44 μM, respectively. The designed electrochemical sensor was successfully applied for the detection of nitrite in water, milk, and natural fruit juice samples.  相似文献   

13.
A liquid chromatographic method was developed using pulsed amperometric detection at a gold working electrode to measure residue levels of ethylenethiourea (ETU) in crops and groundwater. Use of the sequential pulsing program eliminates electrode fouling while preserving the sensitive and selective detection of ETU. Minimum detection limits in crops were 5-10 ppb (1.25-2.5 ng on-column) and 5 ppb (0.5 ng) in groundwater. The commercial availability of the pulsed electrochemical detector and its gold working electrode that remains functional with a minimum of conditioning is an improvement in method simplicity.  相似文献   

14.
Recent progress in flexible and lightweight electrochemical sensor systems requires the development of paper-like electrode materials. Here, we report a facile and green synthesis of a new type of MnO2 nanowires–graphene nanohybrid paper by one-step electrochemical method. This strategy demonstrates a collection of unique features including the effective electrochemical reduction of graphene oxide (GO) paper and the high loading of MnO2 nanowires on electrochemical reduced GO (ERGO) paper. When used as flexible electrode for nonenzymatic detection of hydrogen peroxide (H2O2), MnO2–ERGO paper exhibits high electrocatalytic activity toward the redox of H2O2 as well as excellent stability, selectivity and reproducibility. The amperometric responses are linearly proportional to H2O2 concentration in the range 0.1–45.4 mM, with a detection limit of 10 μM (S/N = 3) and detection sensitivity of 59.0 μA cm−2 mM−1. These outstanding sensing performances enable the practical application of MnO2–ERGO paper electrode for the real-time tracking H2O2 secretion by live cells macrophages. Therefore, the proposed graphene-based nanohybrid paper electrode with intrinsic flexibility, tailorable shapes and adjustable properties can contribute to the full realization of high-performance flexible electrode material used in point-of-care testing devices and portable instruments for in-vivo clinical diagnostics and on-site environmental monitoring.  相似文献   

15.
16.
Rajesh N. Hegde 《Talanta》2009,79(2):361-368
A simple and rapid electrochemical method was developed for the determination of trace-level trazodone, based on the excellent properties of multi-walled carbon nanotubes (MWCNTs). The MWCNT-modified glassy carbon electrode was constructed and the electrochemical behavior of trazodone was investigated in detail. The cyclic voltammetric results indicate that MWCNT-modified glassy carbon electrode can remarkably enhance electrocatalytic activity towards the oxidation of trazodone in neutral solutions. It leads to a considerable improvement of the anodic peak current for trazodone, and allows the development of a highly sensitive voltammetric sensor for the determination of trazodone. Trazodone could effectively accumulate at this electrode and produce two anodic peaks at about 0.73 V and 1.00 V. The electrocatalytic behavior was further exploited as a sensitive detection scheme for the trazodone determination by differential-pulse voltammetry. Under optimized conditions, the concentration range and detection limit are 0.2-10 μM and 24 nM, respectively for trazodone. The proposed method was successfully applied to trazodone determination in pharmaceutical samples. The analytical performance of this sensor has been evaluated for detection of analyte in urine as a real sample.  相似文献   

17.
This work describes the development of an electrochemical sensor for simultaneous detection of Zn(II), Cd(II), and Pb(II) using a graphene–polyaniline (G/PANI) nanocomposite electrode prepared by reverse-phase polymerization in the presence of polyvinylpyrrolidone (PVP). Two substrate materials (plastic film and filter paper) and two nanocomposite deposition methods (drop-casting and electrospraying) were investigated. Square-wave anodic stripping voltammetry currents were higher for plastic vs. paper substrates. Performance of the G/PANI nanocomposites was characterized by scanning electron microscopy (SEM) and cyclic voltammetry. The G/PANI-modified electrode exhibited high electrochemical conductivity, producing a three-fold increase in anodic peak current (vs. the unmodified electrode). The G/PANI-modified electrode also showed evidence of increased surface area under SEM. Square-wave anodic stripping voltammetry was used to measure Zn(II), Cd(II), and Pb(II) in the presence of Bi(III). A linear working range of 1–300 μg L−1 was established between anodic current and metal ion concentration with detection limits (S/N = 3) of 1.0 μg L−1 for Zn(II), and 0.1 μg L−1 for both Cd(II) and Pb(II). The G/PANI-modified electrode allowed selective determination of the target metals in the presence of common metal interferences including Mn(II), Cu(II), Fe(III), Fe(II), Co(III), and Ni(II). Repeat assays on the same device demonstrated good reproducibility (%RSD < 11) over 10 serial runs. Finally, this system was utilized for determining Zn(II), Cd(II), and Pb(II) in human serum using the standard addition method.  相似文献   

18.
Vastarella W  Nicastri R 《Talanta》2005,66(3):627-633
In this work quantum-sized CdS nanocrystals were synthesized using a quaternary water-in-oil microemulsion and immobilized onto gold working electrode by self-assembled monolayers techniques. Formaldehyde dehydrogenase was covalently immobilized onto a protecting membrane, which was stratified on part of the semiconductor nanoparticles modified electrode. The covalent enzyme immobilization has been required to improve the stability of the catalytic oxidation of formaldehyde, which occurs after light stimulation of the semiconductor through the electron/hole recombination. A study about the best electrochemical oxidation potentials under different flow conditions was performed. Preliminary sensor stability and interferences tests were also carried out, for a sensitive and selective detection of formaldehyde. A detection limit of 41 ppb of formaldehyde was calculated and an operational stability of 6 h was achieved under flow conditions by means of this novel amperometric biosensor based on FDH-semiconductor hybrid systems, not requiring NAD+/NADH as charge transfer in the enzymatic reaction.  相似文献   

19.
A porous reticulated vitreous carbon (RVC) electrode and a disk electrode coupled in tandem in an electrochemical flow cell has been used for electrolytic removal of interferents before amperometric glucose detection. The electrolytic efficiency at the upstream RVC electrode is 100% at a flow rate of 0.1 mL min−1 or lower. Potential interferents such as acetaminophen, ascorbic acid, and uric acid can be completely eliminated by electrolysis at the RVC electrode. A mixed monolayer comprising glucose oxidase (GOD) and ferrocenyl-1-undecanethiol preformed at the downstream gold disk electrode was used as a mediator-based amperometric glucose sensor. The dependence of the amperometric current on the glucose concentration exhibits good linearity across over three orders of magnitude. The glucose measurements were also found to be reproducible (RSD < 3.5%) and accurate. Unlike the chemiluminescence method, this device obviates the use of carcinogenic substrates and the glucose sensor performance is independent of the oxygen present in sample. On the basis that the RVC electrode requires minimal cleanup and the GOD-modified electrode remains stable for a week, the electrochemical flow cell should be amenable for automated on-line removal of redox interferents for other types of enzyme-based biosensors.  相似文献   

20.
Nanocrystalline graphite-like pyrolytic carbon film (PCF) electrode fabricated by a non-catalytic chemical vapor deposition (CVD) process was used for the simultaneous electrochemical sensing of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The electrode was studied with respect to changes in electrocatalytic activity caused by a simple and fast electrochemical pretreatment. The anodized electrode exhibited excellent performance compared to many chemically modified electrodes in terms of detection limit, linear dynamic range, and sensitivity. Differential pulse voltammetry (DPV) was used for the simultaneous determination of ternary mixtures of DA, AA, and UA. Under optimum conditions, the detection limits were 2.9 μM for AA, 0.04 μM for DA, and 0.03 μM for UA with sensitivities of 0.078, 5.345, and 6.192 A M−1, respectively. The peak separation was 219 mV between AA and DA and 150 mV between DA and UA. No electrode fouling was observed and good reproducibility was obtained in all the experiments. The sensor was successfully applied for the assay of DA in an injectable drug and UA in human urine by using standard addition method.  相似文献   